首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A series of tests on dodecagonal section double skin concrete-filled steel columns (DCS) were carried out in this study. Column specimens having different lengths ranged from 1000 mm to 3500 mm were tested. The behavior and strengths of dodecagonal section double skin concrete-filled steel columns were investigated. In addition, local bucking of inner and outer steel tubes were also investigated. Material properties of the concrete and steel used in the test specimens were measured. The test strengths are compared with the design strengths calculated using the proposed methods based on current AISC Specification and Eurocode for the design of composite structural members. The suitability of design method proposed by other researcher for circular section double skin concrete-filled steel columns for dodecagonal section specimens was also evaluated.  相似文献   

2.
Glass fibre-reinforced polymer (GFRP) tubes are compared to steel spiral reinforcement in circular concrete members with longitudinal reinforcement and prestressing, using six beam tests. Two 324 mm diameter and 4.2 m long prestressed specimens were tested in bending. Four 219 mm diameter reinforced specimens were also tested, including two 2.43 m long beams tested in bending and two 0.6 m long beams tested in shear. In each set, one specimen was essentially a concrete-filled GFRP tube, while the other control specimen included steel spiral reinforcement of comparable hoop stiffness to that of GFRP tube. The strength of control specimens was governed by crushing and spalling of concrete cover. Unlike spiral reinforcement, GFRP tubes confined larger concrete areas and also contributed as longitudinal reinforcement, leading to increases in flexural and shear strengths, up to 113% and 69%, respectively.  相似文献   

3.
The experimental studies on the behaviour of recycled aggregate concrete-filled steel tube (RACFST) stub columns after exposed to high temperatures are reported in this paper. Forty specimens, including 32 RACFST stub columns and 8 normal concrete-filled steel tube (CFST) stub columns as reference, were tested, and the failure pattern, load versus strain relation and ultimate strength of the specimens were presented and analysed. Five types of concrete were produced: one reference concrete with natural aggregates, two concrete mixes with recycled coarse aggregate (RCA) replacement ratios of 50% and 100%, and two concrete mixes with recycled fine aggregate (RFA) replacement ratios of 50% and 100%. The specimens were exposed to 300 °C, 600 °C and 800 °C for 3 h. The test results showed that, due to the existence of the recycled aggregates, the post-fire performance of RACFST stub columns was lower than the corresponding normal CFST specimens under the same maximum temperature suffered, and the RACFST specimens with RCA had a better behaviour than those with RFA under the same recycled aggregate replacement ratio.  相似文献   

4.
The objective of this research is to investigate the seismic performance of the composite joint consisting of square concrete filled thin-walled steel tubular (CFTST) column and steel beam with end plate and blind bolts. The cold-formed square tube in each CFTST column connection was fabricated by seam welding together four pieces of lipped angle with nominal wall thickness 1.5 mm or 3 mm. Four exterior joint specimens were tested under axially compressive load on the top of the columns and cyclic loads on the beam tip. The experimental parameters in the study were the thickness of the steel tube and the type of end plate. The seismic response of the blind bolted moment joints to CFTST columns was analyzed and evaluated in terms of the hysteretic behavior, failure modes, stiffness and strength degradation, ductility, and energy dissipation capacities of the joints. To improve the tension behavior of the blind bolted moment connections to the thin tube wall, the anchorage action of reinforcing rebar welded to the bolts with concrete-filled steel tubes was also investigated to consider the effect of cyclic loading. The experimental and analytical results indicated that when the end plate thickness is not less than 3 mm, the flush or extended end plate joints to CFTST columns exhibited large hysteretic loops and excellent seismic performance, such as ductility and energy dissipation capacity. The proposed innovative blind bolted joint was verified as a reliable and effective solution applied in mid- and low-rise buildings through properly design and detailing.  相似文献   

5.
This paper presents results of testing 16 specimens, 12 of which as columns under different eccentricities and four as beams under four point loading regime. All 16 specimens were circular in cross section and were made of reinforced concrete. Four specimens served as reference specimens and were just made of reinforced concrete. The next four specimens were wrapped with carbon fibre reinforced polymers (CFRP). The next four specimens had steel fibres added to the concrete. The final four specimens were reinforced with steel fibres and wrapped with CFRP. From each group of specimens, one specimen was tested as a column under a concentric load, the second specimen was tested as a column under 25 mm eccentricity, the third specimen was tested as a column under 50 mm eccentricity, and the final specimen was tested as a beam under four point loading regime. The experimental programme proved that the introduction of fibres as well as wrapping the specimens with FRP improve the properties of concrete, especially its ductility.  相似文献   

6.
This paper presents an experimental investigation of concrete-filled cold-formed high strength stainless steel tube columns. The high strength stainless steel tubes had a yield stress and tensile strength up to 536 and 961 MPa, respectively. The behaviour of the columns was investigated using different concrete cylinder strengths varied from 40 to 80 MPa. A series of tests was performed to investigate the effects of the shape of the stainless steel tube, plate thickness and concrete strength on the behaviour and strength of concrete-filled high strength stainless steel tube columns. The high strength stainless steel tubes were cold-rolled into square and rectangular hollow sections. The depth-to-plate thickness ratio of the tube sections varied from 25.7 for compact sections to 55.8 for relatively slender sections. The columns had different lengths so the length-to-depth ratio generally remained at a constant value of 3. The concrete-filled high strength stainless steel tube specimens were subjected to uniform axial compression. The column strengths, load-axial strain relationships and failure modes of the columns were presented. The test strengths were compared with the design strengths calculated using the American specifications and Australian/New Zealand standards that consider the effect of local buckling using an effective width concept in the calculation of the stainless steel tube column strengths. Based on the test results, design recommendations were proposed for concrete-filled high strength stainless steel tube columns.  相似文献   

7.
High strength steels with the nominal yield strength more than 460 MPa have begun to be applied in the construction of many steel structures, but there are short of sound researches on the major axis buckling behavior of such steel welded I-section columns, especially for the ultra-high strength steels having the nominal yield strength more than 690 MPa. In this paper, the experimental research is described on the overall buckling behavior about the major axis of ultra-high strength steel compression I-section columns with end restraints. In this research 8 columns made from 2 kinds of ultra-high strength structural steels S690 and S960, with nominal yield strengths of 690 MPa and 960 MPa, respectively, were tested. Based on the test results, the finite element analysis (FEA) model was validated to analyze this behavior of ultra-high strength steel columns, and the buckling strength of pin-ended columns fabricated from such steels were calculated by the verified FEA model, which were compared with the design buckling strengths according to the Eurocode 3, the American specification for structural steel buildings ANSI/AISC 360–05, and the Chinese codes for steel structures design GB50017-2003 respectively. It shows that the major axis nondimensional buckling strengths of the ultra-high strength steel compression columns, whose buckling curve is type b according to Eurocode 3 and GB50017-2003, are much higher than that calculated according to the column curve b, even higher than the curve a0 in Eurocode 3 and the curve a in GB50017-2003 on average, and they are also higher than the design values according to ANSI/AISC 360–05. It is therefore indicated that the buckling strength about the major axis of the ultra-high strength steel I-section columns is improved a lot compared with the ordinary strength steel columns on a non-dimensional basis, and the column curve a0 and curve a can be adopted to design this behavior in Eurocode 3 and GB50017-2003, respectively. Besides, there is no obvious difference between the major axis nondimensional buckling strengths of the pin-ended I-section columns fabricated from these two kinds of ultra-high strength steels: S690 and S960. These research works will provide the test basis to complete the buckling design method and theory of the ultra-high strength steel columns, and also be helpful for the application of ultra-high strength steel structures.  相似文献   

8.
The concrete filled steel tubular (CFST) members become very popular in the construction industry and, at the same time, aging of structures and member deterioration are often reported. The actions like implementation of new materials and strengthening techniques become essential to combat this problem. This research work aimed to investigate the structural improvements of CFST sections with normal strength concrete externally bonded with fibre reinforced polymer (FRP) composites. For this study, compact mild steel tubes were used with the main variable being FRP characteristics. Carbon fibre reinforced polymer (CFRP) fabrics were used as horizontal strips (lateral ties) with several other parameters such as the number of layers, width and spacing of strips. Among thirty specimens, twenty seven were externally bonded with 50 mm width of CFRP strips with a spacing of 20 mm, 30 mm and 40 mm and the remaining three specimens were unbonded. Experiments were undertaken until column failure to fully understand the influence of FRP characteristics on the compressive behaviour of square CFST sections including their failure modes, axial stress–strain behaviour, and load carrying capapcity. From the test results, it was found that the external bonding of CFRP strips provides external confinement pressure effectively and delays the local buckling of steel tube and also improves the load carrying capacity further. Finally, an analytical model was proposed herein for predicting the axial load carrying capacity of strengthened CFST sections under compression.  相似文献   

9.
This paper describes 24 tests conducted on slender circular tubular columns filled with normal, high, and ultra-high strength concrete for plain, bar reinforced and steel fiber reinforced columns. These were reinforced and subjected to both concentric and eccentric axial load. It is a continuation of a previous research paper (Portoles et al., 2011 [1]), which presented test results on eccentrically loaded plain concrete columns. The test parameters are nominal strength of concrete (30, 90 and 130 MPa), eccentricity e (0, 20 and 50 mm) and type of reinforcement. A comparison with the corresponding empty tubular columns is performed, as the aim of the paper is to analyze the influence of each type of infill and establish the best option for practical application. For the limited cases analyzed the results show that the addition of high or ultra-high strength infill is more useful for concentric loaded cases than for eccentric loaded ones, where it seems that the best design option is the utilization of bar reinforced concrete filling rather than steel fiber to reinforce CFST columns. The experimental ultimate load of each test was compared with the design loads from Eurocode 4, accurate for the eccentrically loaded tests.  相似文献   

10.
Over the last several decades, various approaches to strengthening steel structures through the use of Carbon fibre reinforced polymer (CFRP) composites have been investigated; however, most of the studies have been focused on the steel tubes. This paper presents the feasibility analysis on the application of CFRP composite strips to strengthen the CFST column member under axial loading. CFRP strips having a width of 50 mm were used to confine the columns. The experimental parameters were the spacing between the CFRP strips (20 and 30 mm) and number of CFRP layers (one, two and three layers). All columns were tested under axial compression until failure. The experimental results revealed that bonding of CFRP composites effectively delayed the local buckling of the columns and also reduced the axial deformation by providing a confinement/restraining effect against the elastic deformation at both spacings. The confinement effect provided by CFRP composites was increased with the increase in the number of layers; however, the enhancement in buckling stress was not proportional. The load carrying capacity of the column increased with the application of CFRP strips, by up to 30% compared to the of un-strengthened column. From the test results it is suggested that the application of CFRP strips at a spacing of 20 mm or 30 mm is suitable for strengthening of a CFST circular column member; however, the application of strips at intervals of 30 mm recommended as an economical approach to strengthening compared to the 20 mm spacing. Finally, an analytical equation was proposed to predict the load carrying capacity of the CFRP strengthened CFST column, and the average difference between the calculated and experimental value was only ±5%.  相似文献   

11.
This paper presents an experimental investigation on behaviour and design of built-up cold-formed steel section battened columns. The built-up columns were pin-ended and consisted of two cold-formed steel channels placed back-to-back at varied spacing of intersection. The two channels were connected using batten plates, with varying longitudinal spacing. The cold-formed steel channel sections were manufactured by brake-pressing flat strips having a plate thickness of 2 mm. The built-up cold-formed steel section battened columns had different slenderness and geometries but had the same nominal length of 2200 mm. The column strengths, load–axial shortening, load–lateral displacement and load–axial strain relationships were measured in the tests. In addition, the failure modes and deformed shapes at failure were observed in the tests and reported in this paper. Overall, the built-up column tests provided valuable experimental data regarding the column behaviour that compensated the lack of information on this form of construction as well as used to develop nonlinear 3-D finite element models. The column strengths measured experimentally were compared against design strengths calculated using the North American Specification, Australian/New Zealand Standard and European Code for cold-formed steel columns. Generally, it is shown that the specifications were unconservative for the built-up cold-formed steel section battened columns failing mainly by local buckling, while the specifications were conservative for the built-up columns failing mainly by elastic flexural buckling.  相似文献   

12.
The paper presents results of an investigation conducted to study the impact resistance of steel fibre reinforced concrete containing fibres of mixed aspect ratio. An experimental investigation was planned in which 108 plain concrete and SFRC beam specimens of size 100 × 100 × 500 mm were tested under impact loading. The specimen incorporated three different volume fractions i.e. 1.0%, 1.5% and 2.0% of corrugated steel fibres. Each volume fraction incorporated mixed steel fibres of size 0.6 × 2.0 × 25 mm and 0.6 × 2.0 × 50 mm in different proportions. The drop weight type impact tests were conducted on the test specimens and the number of blows of the hammer required to induce first visible crack and ultimate failure of the specimen were recorded. The results are presented in terms of number of blows required as well as impact energy at first crack and ultimate failure. It has been observed that concrete containing 100% long fibres at 2.0% volume fraction gave the best performance under impact loading.  相似文献   

13.
In this study, a new type of hybrid confining device, a perforated steel tube that is externally protected by a thin fiber reinforced polymer skin is proposed and experimentally investigated. Hybrid composite beams were fabricated by filling fresh concrete into the hybrid composite tube. Fifteen scaled-down square beams, which had varying numbers of perforated steel faces or ‘steel grids’ and a dimension of length 55.9 cm, height 10.1 cm, and width 10.1 cm, were prepared. Four-point bending tests were conducted on all the specimens. In addition to the load–displacement curves obtained from the tests, strain gages were installed to monitor the local strain distributions. Test results show that the grid tube encased specimens lead to higher specific strength and ductility than the solid steel tube encased counterparts. Compared to other configurations, the specific strength and ductility are the highest when all the four faces are made of steel grids.  相似文献   

14.
Corrosion of steel bars embedded in concrete having compressive strengths of 20, 30 and 46 MPa was investigated. Reinforced concrete specimens were immersed in a 3% NaCl solution by weight for 1, 7 and 15 days. In order to accelerate the chemical reactions, an external current of 0.4 A was applied using portable power supply. Corrosion rate was measured by retrieving electrochemical information of polarization technique. Pull-out tests of reinforced concrete specimens were then conducted to assess the corroded steel/concrete bond characteristics.Experimental results showed that corrosion rate of steel bars and bond strength between corroded steel/concrete were dependent on concrete strength and accelerated corrosion period. As concrete strength increased from 20 to 46 MPa, corrosion rate of embedded steel decreased. First day of corrosion acceleration caused a slight increase in steel/concrete bond strength, whereas sever corrosion after 7 and 15 days of corrosion acceleration significantly reduced steel/concrete bond strength. Visual and metallographic observation of steel bars removed from concrete samples after testing revealed that the severity of corrosion reactions and reduction of steel bar diameter increased as the corrosion acceleration period increased. Presence of localized corrosion pits as well as severe corrosion grooves of steel bars was confirmed after 7 and 15 days of corrosion acceleration, respectively.  相似文献   

15.
Nonlinear analysis of concrete-filled steel SHS and RHS columns   总被引:1,自引:0,他引:1  
Ehab Ellobody  Ben Young   《Thin》2006,44(8):919-930
This paper presents an accurate nonlinear finite element model for the behaviour and design of axially loaded concrete-filled square hollow section (SHS) and rectangular hollow section (RHS) steel tube columns. The nonlinear material models for confined concrete and steel tubes were carefully modeled in the finite element analysis. The column strengths and load-axial shortening curves were evaluated. The results obtained from the finite element analysis were verified against experimental results. An extensive parametric study was conducted to investigate the effects of different concrete strengths and cross-section geometries on the strength and behaviour of concrete-filled SHS and RHS steel tube columns. The study was conducted over a wide range of concrete cube strengths ranged from 30 to 110 MPa. The overall depth of the steel tube-to-plate thickness ratio ranged from 10 to 40 covering compact SHS and RHS steel tube sections. The column strengths predicted from the finite element analysis were compared with the design strengths calculated using the American, Australian and European specifications. Based on the results obtained from the parametric study, it is found that the design strengths calculated using the American Specifications and Australian Standards are conservative, while the design strengths calculated using the European Code are accurate, except for the concrete-filled RHS compact steel tube columns having the overall depth of the steel tube-to-plate thickness ratio of 40.  相似文献   

16.
This paper presents the results of the first phase of a study on the effect of the confinement provided by transverse carbon fiber reinforced polymer (CFRP) sheets on the fatigue bond strength of steel reinforcing bars in concrete beams. Reinforced concrete bond-beams 150 × 250 × 2000 mm were tested. The variables examined were the area of the CFRP sheets (none or one U-wrap CFRP sheet), the reinforcing bar diameter (20 or 25 mm) and the load range applied to the specimens. The results showed that increasing the bar diameter increased the fatigue bond strength for the unwrapped beams. The CFRP sheets increased the bond strength of the bond-beams with 20 mm bars. However, for the beams with 25 mm steel bars the failure mode changed from a bond splitting failure for the unwrapped beams to a diagonal shear failure for the CFRP wrapped beams, and there was little increase in fatigue strength. Finally, the bond failure mechanism for repeated loading is described.  相似文献   

17.
C20 and C30 classes of concrete are produced each with addition of Dramix RC-80/0.60-BN type of steel fibers (SFs) at dosages of 0, 30, 60 kg/m3, and their compressive strengths, split tensile strength, moduli of elasticity and toughnesses are measured. Nine reinforced concrete (RC) beams of 300 × 300 × 2000 mm outer dimensions, designed as tension failure and all having the same steel reinforcement, having SFs at dosages of 0, 30, 60 kg/m3 with C20 class concrete, and nine other RC beams of the same peculiarities with C30 class concrete again designed as tension failure and all having the same reinforcement are produced and tested under simple bending. The load versus mid-span deflection relationships of all these RC and steel-fiber-added RC (SFARC) beams under simple bending are recorded. First, the mechanical properties of C20 and C30 classes of concrete with no SFs and with SFs at dosages of 30 and 60 kg/m3 are determined in a comparative way. The flexural behaviours and toughnesses of RC and SFARC beams for C20 and C30 classes of concrete are also determined in a comparative way. The experimentally determined (mid-section load)–(SFs dosage) and (toughness)–(SFs dosage) relationships are given to reveal the quantitative effects of concrete class and SFs dosage on these crucial properties.  相似文献   

18.
Experimental studies on the behaviour of concrete filled double-skin steel tube (CFDST) subjected to local bearing forces are presented in this paper. Sixteen specimens were prepared and tested with the included angle between bearing member (BM) and compression member of 45° and 90°, whilst both the inner and outer steel tubes of the CFDST specimens are square hollow sections (SHS). The main parameters in the tests were: 1) outside width ratio between BM and compression member: from 0.4 to 0.6; 2) hollow ratio of CFDST: from 0 to 0.6; 3) wall thickness of outer steel tube: 3.05 mm and 3.95 mm; and 4) cross-section of BM: solid and hollow. The failure pattern, load versus deformation curve, bearing capacity and corresponding deformation at bearing capacity of the tested specimens are presented and analyzed. The experimental results show that, while subjected to local bearing forces, CFDST specimens have a high bearing capacity and a good deformation-resistant ability. The calculated bearing capacities of CFDST under local bearing forces using the proposed formulae in the paper are evaluated by comparison with the experimental results.  相似文献   

19.
This paper presents results of tests conducted on thin welded rectangular steel stubs filled with concrete that gravel was substituted by 10 mm crushed crystallized slag stone. The studied section was made of two cold steel plates with U shape and welded with electric arc to form a steel box section. The cross-section dimensions were: 100×70×2 mm3. the main studied parameters were the stub height (200, 300, 400, 500 mm), the effect of the in filled concrete, the continued weld and the eccentric force. The tests were carried out 28 days after the date of casting. A total of 20 stubs were tested in a 50 tf machine up to failure, 4 stubs subjected to axial load compression and 16 stubs subjected to eccentric load compression along the minor and major rigidity axis. The aim of the study is to provide some evidences that the use of crushed slag could be integrated in the manufacturing of non-conventional concrete. All failure loads were predicted by using the Euro code 4 and the design method proposed by Z. Vrcelj and B. Uy. From test results, it was confirmed that the length of stubs and the eccentric load had a drastic effect on the load carrying capacity. The failure mode of composite stubs was a local buckling mode with all steel sides deformed outwards. The Euro code 4 loads predictions were generally in good agreement compared with experimental loads and on safe side. The loads results of design method proposed by Vrcelj and B. Uy were generally on safe side compared with experimental load except the columns subject to eccentric load with 400 mm and 500 mm height.  相似文献   

20.
In this study, the alterations at the reinforcement steels embedded in corroded and not corroded reinforcement mortar specimens after high temperatures were investigated. These reinforced mortar specimens with 3 cm and 5 cm covers were first exposed to 20, 100, 200, 300, 500 and 800 °C temperatures. Subsequently, to determine the mechanical properties tensile tests were applied on the steels taken out of these mortar specimens. With the tensile tests performed stress–strain curves of the steel bars exposed to several temperatures were obtained. Besides, yield and ultimate strengths of the steel bars were also determined. It is obtained that, high temperatures affected the mechanical properties of reinforcement steel considerably negatively. Results of the study have shown that the larger the covers are the better the steel bars are protected against high temperatures.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号