首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Ultraviolet photodissociation (UVPD) of chromophore-modified peptides enhances the capabilities for de novo sequencing in a quadrupole ion trap mass spectrometer. Attachment of UV chromophores allows efficient photoactivation of not only the precursor ions but also any fragments that retain the chromophore functionality. For doubly protonated peptides, UVPD leads to a vast reduction in MS/MS complexity. The array of b and y ions typically seen upon collisionally activated dissociation is reduced to a single series of either y or b ions by UVPD depending on the location of the chromophore (i.e., N- or C-terminus). The sulfonation reagent Alexa Fluor 350 (AF350) provided the best overall results for the singly and doubly charged peptides by UVPD. The nonsulfonated analogue of AF350, 7-amino-4-methylcoumarin-3-acetic acid, also led to simplified spectra for doubly charged, but not singly charged, peptides by UVPD. Dinitrophenyl-peptides also yielded simplified spectra by UVPD albeit with a small amount of internal fragments accompanying the series of diagnostic y ions. The success of this MS/MS simplification process stems from extensive secondary fragmentation of any chromophore-containing fragments upon exposure to subsequent laser pulses. Energy-variable UVPD reveals that the abundances of non-chromophore-containing y fragment ions increase linearly with laser pulse energy, suggesting secondary dissociation of these species is insignificant. The abundances of chromophore-containing a/b fragment ions follow a quadratic trend due to the extensive secondary fragmentation at higher laser energies or multiple pulses.  相似文献   

2.
Electron-transfer dissociation (ETD) delivers the unique attributes of electron capture dissociation to mass spectrometers that utilize radio frequency trapping-type devices (e.g., quadrupole ion traps). The method has generated significant interest because of its compatibility with chromatography and its ability to: (1) preserve traditionally labile post-translational modifications (PTMs) and (2) randomly cleave the backbone bonds of highly charged peptide and protein precursor ions. ETD, however, has shown limited applicability to doubly protonated peptide precursors, [M + 2H]2+, the charge and type of peptide most frequently encountered in "bottom-up" proteomics. Here we describe a supplemental collisional activation (CAD) method that targets the nondissociated (intact) electron-transfer (ET) product species ([M + 2H]+*) to improve ETD efficiency for doubly protonated peptides (ETcaD). A systematic study of supplementary activation conditions revealed that low-energy CAD of the ET product population leads to the near-exclusive generation of c- and z-type fragment ions with relatively high efficiency (77 +/- 8%). Compared to those formed directly via ETD, the fragment ions were found to comprise increased relative amounts of the odd-electron c-type ions (c+*) and the even-electron z-type ions (z+). A large-scale analysis of 755 doubly charged tryptic peptides was conducted to compare the method (ETcaD) to ion trap CAD and ETD. ETcaD produced a median sequence coverage of 89%-a significant improvement over ETD (63%) and ion trap CAD (77%).  相似文献   

3.
Ion-ion reactions between a variety of peptide cations (doubly and triply charged) and SO2 anions have been studied in a 3-D quadrupole ion trap, resulting in proton and electron transfer. Electron transfer dissociation (ETD) gives many c- and z-type fragments, resulting in extensive sequence coverage in the case of triply protonated peptides with SO2*-. For triply charged neurotensin, in which a direct comparison can be made between 3-D and linear ion trap results, abundances of ETD fragments relative to one another appear to be similar. Reactions of doubly protonated peptides with SO2*- give much less structural information from ETD than triply protonated peptides. Collision-induced dissociation (CID) of singly charged ions formed in reactions with SO2*- shows a combination of proton and electron transfer products. CID of the singly charged species gives more structural information than ETD of the doubly protonated peptide, but not as much information as ETD of the triply protonated peptide.  相似文献   

4.
Miniaturized ultra high field asymmetric waveform ion mobility spectrometry (ultra-FAIMS) combined with mass spectrometry (MS) has been applied to the analysis of standard and tryptic peptides, derived from α-1-acid glycoprotein, using electrospray and nanoelectrospray ion sources. Singly and multiply charged peptide ions were separated in the gas phase using ultra-FAIMS and detected by ion trap and time-of-flight MS. The small compensation voltage (CV) window for the transmission of singly charged ions demonstrates the ability of ultra-FAIMS-MS to generate pseudo-peptide mass fingerprints that may be used to simplify spectra and identify proteins by database searching. Multiply charged ions required a higher CV for transmission, and ions with different amino acid sequences may be separated on the basis of their differential ion mobility. A partial separation of conformers was also observed for the doubly charged ion of bradykinin. Selection on the basis of charge state and differential mobility prior to tandem mass spectrometry facilitates peptide and protein identification by allowing precursor ions to be identified with greater selectivity, thus reducing spectral complexity and enhancing MS detection.  相似文献   

5.
First examples of highly charged ions in mass spectrometry (MS) produced from the solid state without using solvent during either sample preparation or mass measurement are reported. Matrix material, matrix/analyte homogenization time and frequency, atmospheric pressure (AP) to vacuum inlet temperature, and mass analyzer ion trap conditions are factors that influence the abundance of the highly charged ions created by laserspray ionization (LSI). LSI, like matrix-assisted laser desorption/ionization (MALDI), uses laser ablation of a matrix/analyte mixture from a surface to produce ions. Preparing the matrix/analyte sample without the use of solvent provides the ability to perform total solvent-free analysis (TSA) consisting of solvent-free ionization and solvent-free gas-phase separation using ion mobility spectrometry (IMS) MS. Peptides and small proteins such as non-β-amyloid components of Alzheimer's disease and bovine insulin are examples in which LSI and TSA were combined to produce multiply charged ions, similar to electrospray ionization, but without the use of solvent. Advantages using solvent-free LSI and IMS-MS include simplicity, rapid data acquisition, reduction of sample complexity, and the potential for an enhanced effective dynamic range. This is achieved by more inclusive ionization and improved separation of mixture components as a result of multiple charging.  相似文献   

6.
The effect of ion space-charge on mass accuracy in Fourier transform ion cyclotron resonance mass spectrometry is examined. Matrix-assisted laser desorption/ionization is used to form a population of high-molecular-weight polymer ions with a wide mass distribution. The density of the ions in the analyzer cell is varied using ion remeasurement and suspended trapping techniques to allow the effect of ion space charge to be examined independently of other experimental influences. Observed cyclotron frequency exhibits a linear correlation with ion population. Mass errors of 100 ppm or more in externally calibrated mass spectra result when ion number is not taken into account. By matching the total ion intensities of calibrant and analyte mass spectra, the protonated ion of insulin B-chain, 3494.6513 Da, is measured with an accuracy of 0.07 ppm (average of 10 measurements, σ = 2.3 ppm, average absolute error 1.6 ppm) using a polymer sample as an external calibrant. Alternatively, the correction for space charge can be made by using a calibration equation that accounts for the total ion intensity of the mass spectrum. A calibration procedure is proposed and is tested with the measurement of the mass of insulin B-chain. A mass accuracy of 2.0 ppm (average of 20 measurements, σ = 4.2 ppm, average absolute error 3.5 ppm) is achieved. Space-charge-induced mass errors are more significant for samples with many components, such as a polymer, than for single-component samples such as purified peptides or proteins.  相似文献   

7.
Infrared atmospheric pressure matrix-assisted laser desorption/ionization on an ion trap mass spectrometer is used to study sialylated oligosaccharides desorbed from the liquid phase. Glycerol doped with various cations provides the opportunity to produce cation-adducted intact molecular ions of sugars. Distinct combinations of cations allow for sialic acid stabilization, as well as differential cleavage, resulting in more complete fragmentation coverage of the oligosaccharide. Alkali and transition metal cations are utilized to create three distinct molecular ion species, involving the adduction of a singly charged cation, two singly charged cations, or a doubly charged cation. From these different molecular ion types, complementary sequence, branching, and linkage information for sialylated oligosaccharides can be deduced.  相似文献   

8.
R Wang  L Chen  R J Cotter 《Analytical chemistry》1990,62(15):1700-1705
Plasma desorption mass spectra were obtained for a series of peptides, grouped in four mass ranges having approximately 9, 20, 30, and 40 amino acid residues. Within each group, the individual peptides differed in hydrophobicity, charge state, and retention time, as measured on a reversed-phase HPLC column. Comparison of the molecular ion intensities in the positive ion mass spectra of peptides from each group showed a strong dependence upon hydrophobicity and no correlation with charge state. Plasma desorption mass spectra of mixtures of all the peptides within each mass range generally resulted in the desorption of a single residue and suppression of the ion signal from other components. In most cases, this could be correlated with hydrophobicity, as calculated from the Bull and Breese index; however, a better correlation existed when the results were compared with reversed-phase retention times. In general the spectra of mixtures were not influenced by charge state (except in the absence of hydrophobic peptides), as the same component in each peptide mixture produced the most abundant ions in both positive and negative ion spectra.  相似文献   

9.
An instrument for the study of gas-phase ion/ion reactions in which three independent sources of ions, namely, two electrospray ionization sources and one atmospheric sampling glow discharge ionization source, are interfaced to a quadrupole ion trap mass analyzer is described. This instrument expands the scope of gas-phase ion/ion reaction studies by allowing for manipulation of the charge states of multiply charged reactant and product ions. Examples are provided involving the formation of protein-protein complexes in the gas phase. Complexes with charge states that cannot be formed from reactant ion charge states present in the normal electrospray charge state distributions can be formed in the new apparatus. Strategies that rely on both reactant ion charge state manipulation and product ion charge state manipulation are demonstrated. In addition, simplification of product ion spectra generated from dissociation of complexes formed via ion/ion reactions can be effected by using the discharge source to reduce the charge state of the product ions to primarily 1+.  相似文献   

10.
Laserspray ionization (LSI) is a new approach to producing multiply charged ions from solids on surfaces by laser ablation of matrixes commonly used in matrix-assisted laser desorption/ionization (MALDI). We show that the only necessity of the laser for producing multiply charged ions is to deliver particles or droplets of the matrix/analyte mixture to an ionization zone which is simply a heated inlet to the vacuum of the mass spectrometer. Several other methods for delivering sample are demonstrated to produce nearly equivalent results. One example shows the use of an air gun replacing the laser and producing mass spectra of proteins by shooting pellets into a metal plate which has matrix/analyte applied to the opposite side and near the ion entrance inlet to the mass spectrometer. Multiply charged ions of proteins are produced in the absence of any electric field or laser and with only the need of a heated ion entrance capillary or skimmer. The commonality of the matrix with MALDI and the mild conditions necessary for formation of ions brings into question the mechanism of formation of multiply charged ions and the importance of matrix structure in this process.  相似文献   

11.
One of the major factors governing the "top-down" sequence analysis of intact multiply protonated proteins by tandem mass spectrometry is the effect of the precursor ion charge state on the formation of product ions. To more fully understand this effect, electrospray ionization coupled to a quadrupole ion trap mass spectrometer, collision-induced dissociation, and gas-phase ion/ion reactions have been employed to examine the fragmentation of the [M + 12H]12+ to [M + H]+ ions of bovine ubiquitin. At low charge states (+1 to +6), loss of NH3 or H2O from the protonated precursor and directed cleavage at aspartic acid residues was observed. At intermediate charge states, (+7, +8, and +9), extensive nonspecific fragmentation of the protein backbone was observed, with 50% sequence coverage obtained from the [M + 8H]8+ ion alone. At high charge states, (+10, +11, +12), the single dominant channel that was observed was the preferential fragmentation of a single proline residue. These data can be readily explained in terms of the current model for intramolecular proton mobilization, that is, the "mobile proton model", the mechanisms for amide bond dissociation developed for protonated peptides, as well as the structures of the multiply charged ions of ubiquitin in the gas phase, examined by ion mobility and hydrogen/deuterium exchange measurements.  相似文献   

12.
Zhang Z 《Analytical chemistry》2005,77(19):6364-6373
A kinetic model, based on the "mobile proton" model of peptide fragmentation, has been reported previously for quantitative prediction of low-energy collision-induced dissociation (CID) spectra of singly or doubly charged peptides. For peptides with three or more charges, however, the simulation process is complex and time-consuming. This paper describes a simplified model for quantitative prediction of CID spectra of peptide ions with three or more charges. Improvements on other aspects of the model were also made to accommodate large peptides. The performance of the simplified model was evaluated by generating predictions for many known highly charged peptides that were not included in the training data set. It was shown that the model is able to predict peptide CID spectra with reasonable accuracy in fragment ion intensities for highly charged peptide ions up to 5000 u in mass.  相似文献   

13.
Random noise applied to the end caps of a quadrupole ion trap is shown to be an effective means for the collisional activation of trapped ions independent of mass/charge ratio and number of ions. This technique is compared and contrasted with conventional single-frequency collisional activation for the molecular ion of N,N-dimethylaniline, protonated cocaine, the molecular anion of 2,4,6-trinitrotoluene, and doubly pronated neuromedin U-8. Collisional activation with noise tends to produce more extensive fragmentation than the conventional approach due to the fact that product ions are also kinetically excited in the noise experiment. The efficiency of the noise experiment in producing detectable product ions relative to the conventional approach ranges from being equivalent to being a factor of 3 less efficient. Furthermore, discrimination against low mass/charge product ions is apparent in the data from multiply charged biomolecules. Nevertheless, collisional activation with random noise provides a very simple means for overcoming problems associated with the dependence of single-frequency collisional activation on mass/charge ratio and the number of ions in the ion trap.  相似文献   

14.
The coupling of matrix-assisted laser desorption/ionization (MALDI) to Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) provides an exceptionally capable platform for peptide analysis, but an important limitation of this approach is the difficulty in obtaining informative tandem mass spectra (MS/MS) of singly protonated peptides. This difficulty is especially pronounced with peptide ions containing basic amino acid residues (for example, tryptic peptides). While such ions can be fragmented in some instrument configurations, most FTICR instruments have comparatively little facility for high-energy fragmentation. Here, a novel MS/MS approach implemented with MALDI-FTICR-MS and specifically intended for enhanced fragmentation of singly protonated peptides is described. The method involves infrared irradiation in concert with the simultaneous application of sustained off-resonance irradiation collision-induced dissociation (SORI-CID). This form of MS/MS, described as a combination of infrared and collisional activation (CIRCA), is shown to provide a greater capacity for dissociation of singly charged model peptide ions as compared to infrared multiphoton dissociation (IRMPD) or SORI-CID alone. Overall, the CIRCA approach is demonstrated to be a feasible technique for accessing useful fragmentation pathways of singly charged peptides, including those harboring basic amino acid residues--a crucial feature in the context of proteomics.  相似文献   

15.
A matrix-assisted laser desorption/ionization (MALDI) ion trap mass spectrometer of new design is described. The instrument is based on a commercial Finnegan LCQ ion trap mass spectrometer to which we have added a MALDI ion source that incorporates a sample stage constructed from a compact disk and a new ion transmission interface. The ion interface contains a quadrupole ion guide installed between the skimmer and the octapoles of the original instrument configuration, allowing for operation in both MALDI and electrospray ionization modes. The instrument has femtomole sensitivity for peptides and is capable of collecting a large number of MALDI MS and MALDI MS/MS spectra within a short period of time. The MALDI source produces reproducible signals for 10(4)-10(5) laser pulses, enabling us to collect MS/MS spectra from all the discernible singly charged ions detected in a MS peptide map. We describe the different modes of the instrument operation and algorithms for data processing as applied to challenging protein identification problems.  相似文献   

16.
The first examples of highly charged ions observed under intermediate pressure (IP) vacuum conditions are reported using laser ablation of matrix/analyte mixtures. The method and results are similar to those obtained at atmospheric pressure (AP) using laserspray ionization (LSI) and/or matrix assisted inlet ionization (MAII). Electrospray ionization (ESI), LSI, and MAII are methods operating at AP and have been shown, with or without the use of a voltage or a laser, to produce highly charged ions with very similar ion abundance and charge states. A commercial matrix-assisted laser desorption/ionization ion mobility spectrometry (IMS) mass spectrometry (MS) instrument (SYNAPT G2) was used for the IP developments. The necessary conditions for producing highly charged ions of peptides and small proteins at IP appear to be a pressure drop region and the use of suitable matrixes and laser fluence. Ionization to produce these highly charged ions under the low pressure conditions of IP does not require specific heating or a special inlet ion transfer region. However, under the current setup, ubiquitin is the highest molecular weight protein observed. These findings are in accord with the need to provide thermal energy in the pressure drop region, similar to LSI and MAII, to improve sensitivity and extend the types of compounds that produce highly charged ions. The practical utility of IP-LSI in combination with IMS-MS is demonstrated for the analysis of model mixtures composed of a lipid, peptides, and a protein. Further, endogenous multiply charged peptides are observed directly from delipified mouse brain tissue with drift time distributions that are nearly identical in appearance to those obtained from a synthesized neuropeptide standard analyzed by either LSI- or ESI-IMS-MS at AP. Efficient solvent-free gas-phase separation enabled by the IMS dimension separates the multiply charged peptides from lipids that remained on the delipified tissue. Lipid and peptide families are exceptionally well separated because of the ability of IP-LSI to produce multiple charging.  相似文献   

17.
Charge reduction electrospray mass spectrometry   总被引:3,自引:0,他引:3  
A new mass spectrometric technique, charge reduction electrospray mass spectrometry (CREMS), allowing the analysis of complex mixtures of biological molecules is described. The charge state of ions produced by electrospray ionization may be reduced in a controlled manner to yield predominantly singly charged ions through reactions with bipolar (i.e., both positively and negatively charged) ions generated using a 210Po alpha particle source. The electrospray-generated multiply charged ions undergo charge reduction in a "neutralization chamber" positioned before the entrance nozzle to the mass spectrometer. The ions are detected using a commercial orthogonal electrospray time-of-flight mass spectrometer, although the neutralization chamber can be adapted to virtually any mass analyzer. The CREMS results obtained exhibit a signal intensity drop-off with increasing oligonucleotide size similar to that observed with matrix-assisted laser desorption/ionization mass spectrometry. Proton-transfer reactions were found to be responsible for reducing charge on proteins and oligonucleotides in both positive and negative ion mode.  相似文献   

18.
A commercial quadrupole/time-of-flight (QqTOF) tandem mass spectrometer has been adapted for ion/ion reaction studies. To enable mutual storage of oppositely charged ions in a linear ion trap, the oscillating quadrupole field of the second quadrupole of the system (Q2) serves to store ions in the radial dimension while auxiliary radio frequency is superposed on the end lenses of Q2 during the reaction period to create barriers in the axial dimension. A pulsed dual electrospray (ESI) source is directly coupled to the instrument interface for the purpose of proton transfer reactions. Singly and doubly charged protein ions as high in mass as 66 kDa are readily formed and observed after proton-transfer reactions. For the modified instrument, the mass resolving power is approximately 8000 for a wide m/z range, and the mass accuracy is approximately 20 ppm for external calibration and approximately 5 ppm for internal calibration after ion/ion reactions. Parallel ion parking is demonstrated with a six-component protein mixture, which shows the potential application of reducing spectral complexity and concentrating certain charge states. The current system has high flexibility with respect to defining MS(n) experiments involving collision-induced dissociation (CID) and ion/ion reactions. Protein precursor and CID product masses can be determined with good accuracy, providing an attractive platform for top-down proteomics. Electron transfer dissociation ion/ion reactions are implemented by using a pulsed nano-ESI/atmospheric pressure chemical ionization dual source for ionization. The reaction between protonated peptide ions and radical anions of 1,3-dinitrobenzene formed exclusively c- and z-type fragment ions.  相似文献   

19.
Enhanced gas-phase cleavage of peptides adjacent to histidine was investigated. The peptides examined were angiotensins III (RVYIHPF) and IV (VYIHPF) as well as synthetic peptide analogues with altered key residues ((R)VYI-X-Z-F; X = F or H and Z = A, P, or Sar) or a fixed charge M3P(+)CH(2)C(O)-VYIHPF. While all singly protonated peptide ions containing both histidine and arginine fragment nonselectively, the doubly protonated peptide ions with arginine and histidine, and the singly protonated peptides containing histidine but not arginine, cleave in a selective manner. In particular, dominant complementary b+/y+ product ions resulting from cleavage between the HP amide bond are observed. For the fixed-charge derivative, selective cleavage occurs only if a proton is added to produce a doubly charged precursor. The results are consistent with involvement of a protonated histidine in the selective cleavage. The ratio of b+/y+ is determined by the identity of the residue C-terminal to histidine and by the ability of protonated histidine to transfer a proton to the C-terminal leaving fragment. This was probed further by systematically changing the residue C-terminal to histidine and by alkylating histidine. The results indicate that while b+/y+ complementary ion pairs dominate in doubly protonated RVYIHPF, b5(2+) and b6(2+) product ions dominate the spectra of doubly protonated RVYIHAF. Also, dominant b5(2+) product ions are observed when the histidine side chain is alkylated (H) in doubly protonated RVYIHPF. Based on all of the results, a selective fragmentation mechanism for enhanced cleavage at histidine involving an atypical b ion structure is proposed.  相似文献   

20.
Electrospray ionization produces multiply charged molecular ions for biomolecules with molecular weights in excess of 100,000. This allows mass spectrometers with limited mass-to-charge range to extend their molecular weight range by a factor equal to the number of charges. The maximum number of observed charges for peptides and smaller proteins correlates well with the number of basic amino acid residues (Arg, Lys, His), except for disulfide-containing molecules, such as lysozyme and bovine albumin. However, reduction of disulfide linkages with 1,4-dithiothreitol (Cleland's reagent) may allow the protein to be in an extended conformation and make "buried" basic residues available for protonation to yield higher charged molecular ions by the electrospray ionization process. For larger proteins reduction of disulfide bridges greatly increases the maximum charge state, but charging of basic amino acid residues remains less efficient than for smaller proteins.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号