首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Multiphoton microscopy in life sciences   总被引:13,自引:1,他引:12  
Near infrared (NIR) multiphoton microscopy is becoming a novel optical tool of choice for fluorescence imaging with high spatial and temporal resolution, diagnostics, photochemistry and nanoprocessing within living cells and tissues. Three‐dimensional fluorescence imaging based on non‐resonant two‐photon or three‐photon fluorophor excitation requires light intensities in the range of MW cm?2 to GW cm?2, which can be derived by diffraction limited focusing of continuous wave and pulsed NIR laser radiation. NIR lasers can be employed as the excitation source for multifluorophor multiphoton excitation and hence multicolour imaging. In combination with fluorescence in situ hybridization (FISH), this novel approach can be used for multi‐gene detection (multiphoton multicolour FISH). Owing to the high NIR penetration depth, non‐invasive optical biopsies can be obtained from patients and ex vivo tissue by morphological and functional fluorescence imaging of endogenous fluorophores such as NAD(P)H, flavin, lipofuscin, porphyrins, collagen and elastin. Recent botanical applications of multiphoton microscopy include depth‐resolved imaging of pigments (chlorophyll) and green fluorescent proteins as well as non‐invasive fluorophore loading into single living plant cells. Non‐destructive fluorescence imaging with multiphoton microscopes is limited to an optical window. Above certain intensities, multiphoton laser microscopy leads to impaired cellular reproduction, formation of giant cells, oxidative stress and apoptosis‐like cell death. Major intracellular targets of photodamage in animal cells are mitochondria as well as the Golgi apparatus. The damage is most likely based on a two‐photon excitation process rather than a one‐photon or three‐photon event. Picosecond and femtosecond laser microscopes therefore provide approximately the same safe relative optical window for two‐photon vital cell studies. In labelled cells, additional phototoxic effects may occur via photodynamic action. This has been demonstrated for aminolevulinic acid‐induced protoporphyrin IX and other porphyrin sensitizers in cells. When the light intensity in NIR microscopes is increased to TW cm?2 levels, highly localized optical breakdown and plasma formation do occur. These femtosecond NIR laser microscopes can also be used as novel ultraprecise nanosurgical tools with cut sizes between 100 nm and 300 nm. Using the versatile nanoscalpel, intracellular dissection of chromosomes within living cells can be performed without perturbing the outer cell membrane. Moreover, cells remain alive. Non‐invasive NIR laser surgery within a living cell or within an organelle is therefore possible.  相似文献   

2.
Microendoscopy has been an essential tool in exploring micro/nano mechanisms in vivo due to high‐quality imaging performance, compact size and flexible movement. The investigations into optical fibres, micro‐scanners and miniature lens have boosted efficiencies of remote light delivery to sample site and signal collection. Given the light interaction with materials in the fluorescence imaging regime, this paper reviews two classes of compact microendoscopy based on a single fibre: linear optical microendoscopy and nonlinear optical microendoscopy. Due to the fact that fluorescence occurs only in the focal volume, nonlinear optical microendoscopy can provide stronger optical sectioning ability than linear optical microendoscopy, and is a good candidate for deep tissue imaging. Moreover, one‐photon excited fluorescence microendoscopy as the linear optical microendoscopy suffers from severe photobleaching owing to the linear dependence of photobleaching rate on excitation laser power. On the contrary, nonlinear optical microendoscopy, including two‐photon excited fluorescence microendoscopy and second harmonic generation microendoscopy, has the capability to minimize or avoid the photobleaching effect at a high excitation power and generate high image contrast. The combination of various nonlinear signals gained by the nonlinear optical microendoscopy provides a comprehensive insight into biophenomena in internal organs. Fibre‐optical microendoscopy overcomes physical limitations of traditional microscopy and opens up a new path to achieve early cancer diagnosis and microsurgery in a minimally invasive and localized manner.  相似文献   

3.
Multiphoton fluorescence excitation microscopy is almost invariably conducted with samples whose refractive index differ from that of the objective immersion medium, conditions that cause spherical aberration. Due to the quadratic nature of multiphoton fluorescence excitation, spherical aberration is expected to profoundly affect the depth dependence of fluorescence excitation. In order to determine the effect of refractive index mismatch in multiphoton fluorescence excitation microscopy, we measured signal attenuation, photobleaching rates and resolution degradation with depth in homogeneous samples with minimal light scattering and absorption over a range of refractive indices. These studies demonstrate that signal levels and resolution both rapidly decline with depth into refractive index mismatched samples. Analyses of photobleaching rates indicate that the preponderance of signal attenuation with depth results from decreased rates of fluorescence excitation, even in a system with a descanned emission collection pathway. Similar results were obtained in analyses of fluorescence microspheres embedded in rat kidney tissue, demonstrating that spherical aberration is an important limiting factor in multiphoton fluorescence excitation microscopy of biological samples.  相似文献   

4.
Multiphoton excitation laser scanning microscopy, relying on the simultaneous absorption of two or more photons by a molecule, is one of the most exciting recent developments in biomedical imaging. Thanks to its superior imaging capability of deeper tissue penetration and efficient light detection, this system becomes more and more an inspiring tool for intravital bulk tissue imaging. Two‐photon excitation microscopy including 2‐photon fluorescence and second harmonic generated signal microscopy is the most common multiphoton microscopic application. In the present review we take diverse ocular tissues as intravital samples to demonstrate the advantages of this approach. Experiments with registration of intracellular 2‐photon fluorescence and extracellular collagen second harmonic generated signal microscopy in native ocular tissues are focused. Data show that the in‐tandem combination of 2‐photon fluorescence and second harmonic generated signal microscopy as two‐modality microscopy allows for in situ co‐localization imaging of various microstructural components in the whole‐mount deep intravital tissues. New applications and recent developments of this high technology in clinical studies such as 2‐photon‐controlled drug release, in vivo drug screening and administration in skin and kidney, as well as its uses in tumourous tissues such as melanoma and glioma, in diseased lung, brain and heart are additionally reviewed. Intrinsic emission two‐modal 2‐photon microscopy/tomography, acting as an efficient and sensitive non‐injurious imaging approach featured by high contrast and subcellular spatial resolution, has been proved to be a promising tool for intravital deep tissue imaging and clinical studies. Given the level of its performance, we believe that the non‐linear optical imaging technique has tremendous potentials to find more applications in biomedical fundamental and clinical research in the near future.  相似文献   

5.
Fluorescent protein-based FRET is a powerful method for visualizing protein-protein interactions and biochemical reactions in living cells. It can be difficult, however, to avoid photobleaching when observing fluorescent cells under the microscope, especially those expressing CFP. We compared the sensitivity of two protein-based FRET pairs to light-induced fluorescence changes in the donor, on FRET determination by fluorescence lifetime imaging microscopy (FLIM). Thanks to the very low excitation light levels of the time- and space-correlated single photon counting (TSCSPC) method, FLIM acquisitions were achieved without donor photobleaching. Here, we show that photobleaching of CFP by a mercury lamp under the microscope induced a decrease in the mean fluorescence lifetime, which interfered with FRET determination between CFP and YFP. Importantly, the range of light-induced variation of the mean fluorescence lifetime of CFP was not proportional to the decrease in the steady state fluorescence intensity and varied from cell to cell. The choice of the CFP/YFP pair therefore requires that the cells be observed and analyzed at very low light levels during the whole FRET experiment. In contrast, the GFP/mCherry pair provided an accurate FRET measurement by FLIM, even if some GFP photobleaching took place. We thus demonstrate that CFP can be an unreliable donor for FRET determination in living cells, due to its photosensitivity properties. We demonstrate that the GFP/mCherry pair is better suited for FRET measurement by FLIM in living cells than the CFP/YFP pair.  相似文献   

6.
A benefit of multiphoton fluorescence microscopy is the inherent optical sectioning that occurs during excitation at the diffraction-limited spot. The scanned collection of fluorescence emission is incoherent; that is, no real image needs to be formed on the detector plane. The nearly isotropic emission of fluorescence excited at the focal spot allows for new detection schemes that efficiently funnel all attainable photons to detector(s). We previously showed [Combs, C.A., et al. (2007) Optimization of multiphoton excitation microscopy by total emission detection using a parabolic light reflector. J. Microsc. 228, 330-337] that parabolic mirrors and condensers could be combined to collect the totality of solid angle around the excitation spot for tissue blocks, leading to ~8-fold signal gain. Using a similar approach, we have developed an in vivo total emission detection (epiTED) instrument modified to make noncontact images from outside of living tissue. Simulations suggest that a ~4-fold enhancement may be possible (much larger with lower NA objectives than the 0.95 NA used here) with this approach, depending on objective characteristics, imaging depth and the characteristics of the sample being imaged. In our initial prototype, 2-fold improvements were demonstrated in the mouse brain and skeletal muscle as well as the rat kidney, using a variety of fluorophores and no compromise of spatial resolution. These results show this epiTED prototype effectively doubles emission signal in vivo; thus, it will maintain the image signal-to-noise ratio at two times the scan rate or enable full scan rate at approximately 30% reduced laser power (to minimize photo-damage).  相似文献   

7.
In vivo and in vitro multiphoton imaging was used to perform high resolution optical sectioning of human hair by nonlinear excitation of endogenous as well as exogenous fluorophores. Multiphoton fluorescence lifetime imaging (FLIM) based on time-resolved single photon counting and near-infrared femtosecond laser pulse excitation was employed to analyze the various fluorescent hair components. Time-resolved multiphoton imaging of intratissue pigments has the potential (i) to identify endogenous keratin and melanin, (ii) to obtain information on intrahair dye accumulation, (iii) to study bleaching effects, and (iv) to monitor the intratissue diffusion of pharmaceutical and cosmetical components along hair shafts.  相似文献   

8.
Phototoxicity and photobleaching are major limitations of fluorescence live-cell microscopy. A straightforward way to limit phototoxicity and photobleaching is reduction of the excitation light dose, but this causes loss of image quality. In confocal fluorescence microscopy, the field of view is illuminated uniformly whereas in controlled light exposure microscopy, illumination is controlled per pixel on the basis of two illumination strategies. The controlled light exposure microscopy foreground strategy discriminates between bright and weak foreground. Bright foreground pixels are illuminated with a reduced light dose resulting in limited excitation of fluorophores and consequently limited phototoxicity and photobleaching. The controlled light exposure microscopy background strategy discriminates between foreground and background. Pixels that are judged to be background are also illuminated with a reduced light dose. The latter illumination strategy may introduce artefacts due to the stochastic character of photon flow. These artefacts are visible as erratic 'darker pixels' in the foreground with a lower pixel value than the neighbouring pixels. This paper describes a special adaptive image processing filter that detects and corrects most of the 'darker pixels'. It opens the possibility to use controlled light exposure microscopy even in high noise (low signal to noise ratio) imaging to further reduce phototoxicity and photobleaching.  相似文献   

9.
Two-photon excitation laser scanning fluorescence microscopy (2p-LSM) was compared with UV-excitation confocal laser scanning fluorescence microscopy (UV-CLSM) in terms of three-dimensional (3-D) calcium imaging of living cells in culture. Indo-1 was used as a calcium indicator. Since the excitation volume is more limited and excitation wavelengths are longer in 2p-LSM than in UV-CLSM, 2p-LSM exhibited several advantages over UV-CLSM: (1) a lower level of background signal by a factor of 6–17, which enhances the contrast by a factor of 6–21; (2) a lower rate of photobleaching by a factor of 2–4; (3) slightly lower phototoxicity. When 3-D images were repeatedly acquired, the calcium concentration determined by UV-CLSM depended strongly on the number of data acquisitions and the nuclear regions falsely exhibited low calcium concentrations, probably due to an interplay of different levels of photobleaching of Indo-1 and autofluorescence, while the calcium concentration evaluated by 2p-LSM was stable and homogeneous throughout the cytoplasm. The spatial resolution of 2p-LSM was worse by 10% in the focal plane and by 30% along the optical axis due to the longer excitation wavelength. This disadvantage can be overcome by the addition of a confocal pinhole (two-photon excitation confocal laser scanning fluorescence microscopy), which made the resolution similar to that in UV-CLSM. These results indicate that 2p-LSM is preferable for repeated 3-D reconstruction of calcium concentration in living cells. In UV-CLSM, 0.18-mW laser power with a 2.φ pinhole (in normalized optical coordinate) gives better signal-to-noise ratio, contrast and resolution than 0.09-mW laser power with a 4.9-φ pinhole. However, since the damage to cells and the rate of photobleaching is substantially greater under the former condition, it is not suitable for repeated acquisition of 3-D images.  相似文献   

10.
A scanning microscope utilizing two-photon excitation in combination with fluorescence lifetime contrast is presented. The microscope makes use of a tunable femtosecond titanium:sapphire laser enabling the two-photon excitation of a broad range of fluorescent molecules, including UV probes. Importantly, the penetration depth of the two-photon exciting (infra)red light is substantially greater than for the corresponding single-photon wavelength while photobleaching is significantly reduced. The time structure of the Ti:Sa laser can be employed in a straightforward way for the realization of fluorescence lifetime imaging. The fluorescence lifetime is sensitive to the local environment of the fluorescent molecule. This behaviour can be used for example to quantify concentrations of ions, such as pH and Ca2+, or pO2 and pCO2. In the set-up presented here the fluorescence lifetime imaging is accomplished by time-gated single photon counting. The performance and optical properties of the microscope are investigated by a number of test measurements on fluorescent test beads. Point-spread functions calculated from measurements on 230-nm beads using an iterative restoration procedure compare well with theoretical expectations. Lifetime imaging experiments on a test target containing two different types of test bead in a fluorescent buffer all with different lifetimes (2.15 ns, 2.56 ns and 3.34 ns) show excellent quantitative agreement with reference values obtained from time correlated single photon counting measurements. Moreover, the standard deviation in the results can be wholly ascribed to the photon statistics. Measurements of acridine orange stained biofilms are presented as an example of the potential of two-photon excitation combined with fluorescence lifetime contrast. Fluorescence lifetime and intensity images were recorded over the whole sample depth of 100 μm. Fluorescence intensity imaging is seriously hampered by the rapid decrease of the fluorescence signal as a function of the depth into the sample. Fluorescence lifetime imaging on the other hand is not affected by the decrease of the fluorescence intensity.  相似文献   

11.
During fluorescent live cell imaging it is critical to keep excitation light dose as low as possible, especially in the presence of photosensitizer drugs, which generate free radicals upon photobleaching. During fluorescent imaging, stress by excitation and free radicals induces serious cell damages that may arrest the cell cycle. This limits the usefulness of the technique for drug discovery, when prolonged live cell imaging is necessary. This paper presents a strategy to provide gentle experimental conditions for dynamic monitoring of the proliferation of human lung epithelial carcinoma cells (A549) in the presence of the photosensitizer Polyvinylpyrrolidone-Hypericin. The distinctive strategy of this paper is based on the stringent environmental control and optimizing the excitation light dose by (i) using a low-power pulsed blue light-emitting diode with short pulse duration of 1.29 ms and (ii) adding a nontoxic fluorescent dye called carboxyfluorescein-diacetate-succinimidyl-ester (CFSE) to improve the fluorescence signals. To demonstrate the usefulness of the strategy, fluorescence signals and proliferation of dual-marked cells, during 5-h fluorescence imaging under pulsed excitation, were compared with those kept under continuous excitation and nonmarked reference cells. The results demonstrated 3% cell division and 2% apoptosis due to pulsed excitation compared to no division and 85% apoptosis under the continuous irradiation. Therefore, our strategy allows live cell imaging to be performed over longer time scales than with conventional continuous excitation.  相似文献   

12.
A theory for multiphoton fluorescence imaging in high aperture scanning optical microscopes employing finite sized detectors is presented. The effect of polarisation of the fluorescent emission on the imaging properties of such microscopes is investigated. The lateral and axial resolutions are calculated for one-, two- and three-photon excitation of p-quaterphenyl for high and low aperture optical systems. Significant improvement in lateral resolution is found to be achieved by employing a confocal pinhole. This improvement increases with the order of the multiphoton process. Simultaneously, it is found that, when the size of the pinhole is reduced to achieve the best possible resolution, the signal-to-noise ratio is not degraded by more than 30%. The degree of optical sectioning achieved is found to improve dramatically with the use of confocal detection. For two- and three-photon excitation axial full width half-maximum improvement of 30% is predicted.  相似文献   

13.
Spatial control of pa-GFP photoactivation in living cells   总被引:2,自引:0,他引:2  
Photoactivatable green fluorescent protein (paGFP) exhibits peculiar photo-physical properties making it an invaluable tool for protein/cell tracking in living cells/organisms. paGFP is normally excited in the violet range (405 nm), with an emission peak centred at 520 nm. Absorption cross-section at 488 nm is low in the not-activated form. However, when irradiated with high-energy fluxes at 405 nm, the protein shows a dramatic change in its absorption spectra becoming efficiently excitable at 488 nm. Confocal microscopes allow to control activation in the focal plane. Unfortunately, irradiation extends to the entire illumination volume, making impracticable to limit the process in the 3D (three-dimensional) space. In order to confine the process, we used two advanced intrinsically 3D confined optical methods, namely: total internal reflection fluorescence (TIRF) and two-photon excitation fluorescence (2PE) microscopy. TIRF allows for spatially selected excitation of fluorescent molecules within a thin region at interfaces, i.e. cellular membranes. Optimization of the TIRF optical set-up allowed us to demonstrate photoactivation of paGFP fused to different membrane localizing proteins. Exploitation of the penetration depth showed that activation is efficiently 3D confined even if limited at the interface. 2PE microscopy overcomes both the extended excitation volume of the confocal case and the TIRF constraint of operating at interfaces, providing optical confinement at any focal plane in the specimen within subfemtoliter volumes. The presented results emphasize how photoactivation by non-linear excitation can provide a tool to increase contrast in widefield and confocal cellular imaging.  相似文献   

14.
Long-term high-resolution multiphoton imaging of nonlabeled human salivary gland stem cell spheroids has been performed with submicron spatial resolution, 10.5-nm spectral resolution, and picosecond temporal resolution. In particular, the two-photon-excited coenzyme NAD(P)H and flavins have been detected by time-correlated single photon counting (TCSPC). Stem cells increased their autofluorescence lifetimes and decreased their total fluorescence intensity during the adipogenic-differentiation process. In addition, the onset of the biosynthesis of lipid vacuoles was monitored over a period of several weeks in stem-cell spheroids. Time-resolved multiphoton autofluorescence imaging microscopes may become a promising tool for marker-free stem-cell characterization and cell sorting.  相似文献   

15.
Stimulated emission depletion (STED) microscopy is a useful tool in investigation for super‐resolution realm. By silencing the peripheral fluorophores of the excited spot, leaving only the very centre zone vigorous for fluorescence, the effective point spread function (PSF) could be immensely squeezed and subcellular structures, such as organelles, become discernable. Nevertheless, because of the low cross‐section of stimulated emission and the short fluorescence lifetime, the depletion power density has to be extremely higher than the excitation power density and molecules are exposed in high risk of photobleaching. The existence of photobleaching greatly limits the research of STED in achieving higher resolution and more delicate imaging quality, as well as long‐term and dynamic observation. Since the first experimental implementation of STED microscopy, researchers have lift out variety of methods and techniques to alleviate the problem. This paper would present some researches via conventional methods which have been explored and utilised relatively thoroughly, such as fast scanning, time‐gating, two‐photon excitation (TPE), triplet relaxation (T‐Rex) and background suppression. Alternatively, several up‐to‐date techniques, especially adaptive illumination, would also be unveiled for discussion in this paper. The contrast and discussion of these modalities would play an important role in ameliorating the research of STED microscopy.  相似文献   

16.
The green fluorescent protein has gained interest in bioanalytical applications due to its visible fluorescence. As the usage of green fluorescent protein increases, more appropriate fluorescence instrumentation is required. Most fluorescence instrumentation uses ultraviolet light as the excitation source for the determination of green fluorescent protein. However, ultraviolet radiation may damage biological molecules and affect the quantitative analysis. In this study, the effects of the ultraviolet radiation period and the mass of green fluorescent protein on the fluorescence determination were characterized using gel imaging. The ultraviolet illumination period affected the green fluorescent protein fluorescence intensity. The fluorescence increased with the ultraviolet illumination time from 30–90 s. However, the fluorescence intensity decreased when the excitation period was longer, probably due to photobleaching. The photobleaching decreased when a higher concentration of enhanced green fluorescent protein was employed. This gel imaging study has provided a better understanding of the optimum conditions for the determination of green fluorescent protein.  相似文献   

17.
Multiphoton microscopy is widely employed in the life sciences using extrinsic fluorescence of low‐ and high‐molecular weight labels with excitation and emission spectra in the visible and near infrared regions. For imaging of intrinsic and extrinsic fluorophores with excitation spectra in the ultraviolet region, multiphoton excitation with one‐ or two‐colour lasers avoids the need for ultraviolet‐transmitting excitation optics and has advantages in terms of optical penetration in the sample and reduced phototoxicity. Excitation and detection of ultraviolet emission around 300 nm and below in a typical inverted confocal microscope is more difficult and requires the use of expensive quartz optics including the objective. In this technical note we describe the adaptation of a commercial confocal microscope (Nikon, Japan E‐C1 or E‐C2) for versatile use with Ti‐sapphire and OPO laser sources and the addition of a second detection channel that enables detection of ultraviolet fluorescence and increases detection sensitivity in a typical fluorescence lifetime imaging microscopy experiment. Results from some experiments with this setup illustrate the resulting capabilities.  相似文献   

18.
Ultrafast lasers have found increasing use in scanning optical microscopy due to their very high peak power in generating multiphoton excitations. A mode-locked Ti:sapphire laser is often employed for such purposes. Together with a synchronously pumped optical parametric oscillator (OPO), the spectral range available can be extended to 1,050-1,300 nm. This broader range available greatly facilitates the excitation of second harmonic generation (SHG) and third harmonic generation (THG) due to better satisfaction of phase matching condition that is achieved with a longer excitation wavelength. Dental sections are then investigated with the contrasts from harmonic generation. In addition, through intra-cavity doubling wavelengths from 525-650 nm are made available for effective two-photon (2-p) excitation with the equivalent photon energy in the UVB range (290-320 nm) and beyond. This new capacity allows UV (auto-) fluorescence excitation and imaging, for example, from some amino acids, such as tyrosine, tryptophan, and glycine.  相似文献   

19.
The method of cumulants has been applied to digital video fluorescence microscopy. The method is used to reconstruct the distribution of fluorescent molecules before the initiation of fluorescence photobleaching, and to characterize heterogeneous photobleaching by imaging one or more of the cumulants of the bleaching decay rate. Using the pipelined pixel processor of the image analysis system for the bulk of the calculations, rather than the general-purpose host-computer CPU, the video kinetics imaging can be performed in near real-time. The method is applied to chick embryo myotubes labelled with fluorescein-conjugated α-bungarotoxin. The pre-bleach fluorescence distribution is derived, and the image of fluorescein fluorescence is separated from glutaraldehyde-induced autofluorescence on the basis of the spatially resolved average photobleaching decay rate.  相似文献   

20.
Because of the spreading of nonlinear microscopies in biology, there is a strong demand for specifically engineered probes in these applications. Herein, we report on the imaging properties in living cells and nude mice brains of recently developed water soluble blue fluorophores that show efficient diffusion through cell membranes and blood-brain barriers. They are characterized by two-photon absorption cross-sections of 100-150 Goeppert-Mayer range in the near IR and fluorescence efficiencies of up to 72% in water. They were found to stain homogeneously the cytoplasm of cultured living cells within minutes. Moreover, their diffusion times and fluorescence characteristics in the cytoplasm suggest a hydrophobic association with intracellular membranes. Their intracellular fluorescent decays were found to be almost mono-exponential, a very favorable feature for fluorescence lifetime imaging. Two photon images of living cells were obtained with a good signal to noise ratio using laser powers in the sub-milliwatt range. This allows continuous imaging without significant photobleaching for tens of minutes. In addition, these fluorophores allowed in vivo three-dimensional two-photon imaging of mice cortex vasculatures and extra vasculature structures, with no sign of toxicity.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号