首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Indoor air quality (IAQ) parameters in 73 primary classrooms in Porto were examined for the purpose of assessing levels of volatile organic compounds (VOCs), aldehydes, particulate matter, ventilation rates and bioaerosols within and between schools, and potential sources. Levels of VOCs, aldehydes, PM2.5, PM10, bacteria and fungi, carbon dioxide (CO2), carbon monoxide, temperature and relative humidity were measured indoors and outdoors and a walkthrough survey was performed concurrently. Ventilation rates were derived from CO2 and occupancy data. Concentrations of CO2 exceeding 1000 ppm were often encountered, indicating poor ventilation. Most VOCs had low concentrations (median of individual species <5 μg/m3) and were below the respective WHO guidelines. Concentrations of particulate matter and culturable bacteria were frequently higher than guidelines/reference values. The variability of VOCs, aldehydes, bioaerosol concentrations, and CO2 levels between schools exceeded the variability within schools. These findings indicate that IAQ problems may persist in classrooms where pollutant sources exist and classrooms are poorly ventilated; source control strategies (related to building location, occupant behavior, maintenance/cleaning activities) are deemed to be the most reliable for the prevention of adverse health consequences in children in schools.  相似文献   

2.
We reviewed the literature on Indoor Air Quality (IAQ), ventilation, and building-related health problems in schools and identified commonly reported building-related health symptoms involving schools until 1999. We collected existing data on ventilation rates, carbon dioxide (CO2) concentrations and symptom-relevant indoor air contaminants, and evaluated information on causal relationships between pollutant exposures and health symptoms. Reported ventilation and CO2 data strongly indicate that ventilation is inadequate in many classrooms, possibly leading to health symptoms. Adequate ventilation should be a major focus of design or remediation efforts. Total volatile organic compounds, formaldehyde (HCHO) and microbiological contaminants are reported. Low HCHO concentrations were unlikely to cause acute irritant symptoms (<0.05 ppm), but possibly increased risks for allergen sensitivities, chronic irritation, and cancer. Reported microbiological contaminants included allergens in deposited dust, fungi, and bacteria. Levels of specific allergens were sufficient to cause symptoms in allergic occupants. Measurements of airborne bacteria and airborne and surface fungal spores were reported in schoolrooms. Asthma and 'sick building syndrome' symptoms are commonly reported. The few studies investigating causal relationships between health symptoms and exposures to specific pollutants suggest that such symptoms in schools are related to exposures to volatile organic compounds (VOCs), molds and microbial VOCs, and allergens.  相似文献   

3.
Poor air quality in schools has been associated with adverse health effects. Indoor air quality can be improved by increasing ventilation. The objective of this study was to compare the effectiveness of different interventions to improve ventilation behavior in primary schools. We used indoor CO(2) concentrations as an indicator. In 81 classes of 20 Dutch primary schools, we applied three different interventions: (i) a class-specific ventilation advice; (ii) the advice combined with a CO(2) warning device and (iii) the advice combined with a teaching package. The effectiveness of the interventions was tested directly after intervention and 6 weeks after intervention by measuring the CO(2) concentrations and comparison with a control group (iv). Before intervention, the CO(2) concentration exceeded 1000 ppm for 64% of the school day. The class-specific ventilation advice without further support appeared an ineffective tool to improve ventilation behavior. The advice in combination with a CO(2) warning device or the teaching package proved effective tools and resulted in lower indoor CO(2) concentrations when compared with the control group. Ventilation was significantly improved, but CO(2) concentrations still exceeded 1000 ppm for more than 40% of the school day. Hence, until ventilation facilities are upgraded, the CO(2) warning device and the teaching package are useful low-cost tools. PRACTICAL IMPLICATIONS: To improve ventilation behavior and indoor air quality in schools, CO(2) warning device and teaching package combined with a class-specific ventilation advice, are effective tools, while giving the ventilation advice solely, is not effective. Although ventilation is significantly improved through behavioral change, the ventilation rate is still insufficient to maintain good air quality during the full school day. Therefore, the improvement of the ventilation facilities is recommended. Hence, until ventilation facilities in schools are upgraded, the CO(2) warning device and the teaching package are useful low-cost tools to improve current indoor air quality.  相似文献   

4.
Indoor air quality problems for a typical office space were investigated. Continuous monitoring of concentrations was carried out for CO2, CO, formaldehyde, and total hydrocarbons. It was found that the CO2 concentration was at times above 2000 ppm and that for CO above 14 ppm. In addition, concentration levels of formaldehyde and total hydrocarbon were found to peak at midnight and indicated non-human sources. Partial opening of windows resulted in CO2 concentration levels of 800 ppm or below. Ventilation rate measurements using trace gas decay method found that the air change rates were well below one air change per hour.  相似文献   

5.
Indoor air quality (IAQ) on ships is important for the passengers’ comfort and the crew’s work efficiency, despite ships not being as common as vehicles and airplanes. The builders and operators need to be aware of the importance and present status of IAQ, but sufficient data and information are not available. In this study, we measured the pollutant concentrations on two different kinds of newly launched ships: a passenger ship and a chemical cargo ship. Although higher than in the passenger ship, the concentrations of most volatile organic compounds (VOCs) and formaldehyde in the cargo ship were lower than the recommended standards and acceptable with a few exceptions. The high CO and CO2 concentrations in the kitchen, engine room, and engine control room were generally attributed to combustion sources. Overall, the IAQ of the cargo ship was worse than that of the passenger ship, and the concentrations of some pollutants surpassed the international criteria. For the passenger ship, the variation of IAQ was also investigated after 17 months. The observed data showed some differences in concentration variation according to the types of pollutants. To improve IAQ on ships, more data need to be collected and minimum requirements suggested.  相似文献   

6.
A study was performed to characterize the concentration of dozens of volatile organic compounds (VOCs) at 10 locations within a single large building and track these concentrations over a 2-year period. The study was performed at a shopping center (strip mall) in New Jersey. A total of 130 indoor air samples were collected from 10 retail stores within the shopping center and analyzed for 60 VOCs by US EPA Method TO-15. Indoor concentrations of up to 55,100 microg/m(3) were measured for individual VOCs. The indoor/outdoor ratio (I/O) was as high as 1500 for acetone and exceeded 100 at times for various compounds, indicating that significant indoor air sources were present. A large degree of spatial variability was observed between stores within the building, with concentrations varying by three to four orders of magnitude for some compounds. The spatial variability was dependent on the proximity of the sampling locations to the indoor sources. A large degree of temporal variability also was observed for compounds emitted from indoor sources, but the temporal variability generally did not exceed two standard deviations (sigma). For compounds not emitted from indoor sources at significant rates, both the spatial and temporal variability tended to range within an order of magnitude at each location. PRACTICAL IMPLICATIONS: Many cross-sectional studies have been published where the levels of volatile organic compounds (VOCs) were measured in indoor air at one or two locations for houses or offices. This study provides longitudinal data for a commercial retail building and also addresses spatial variability within the building. The data suggest that spatial and temporal variability are important considerations for compounds emitted from indoor sources. Elevated concentrations were found in retail spaces with no apparent emission sources due to their proximity to other retail spaces with emission sources.  相似文献   

7.
目的:调查高校宿舍室内空气质量(Indoor air quality,IAQ),加强高校管理人员和学生对IAQ的认识,为工程设计人员改善宿舍通风提供依据。方法:利用主观问卷调查与现场测试相结合的方法,从主观和客观两个方面对秦皇岛市某大学的20个学生宿舍、120人进行冬季IAQ调查研究。结果:42.5%的学生对宿舍IAQ表示不满,认为宿舍内空气"很不新鲜"或"不新鲜"的学生高达60.0%,95%的宿舍室内CO_2浓度超过限值1 000 ppm。45.8%的学生认为宿舍内偏冷,70.8%的学生认为宿舍内湿度偏干燥。超过80.0%的学生在宿舍中会偶尔或经常出现注意力不集中的现象,95.0%的学生在宿舍中比在自习室中更容易瞌睡。结论:该校冬季大学生宿舍通风不良,IAQ问题较突出,对学生的注意力和学习状态造成一定影响,应提高建筑设计人员、管理人员和学生对IAQ问题的认识,采取相应措施改善高校宿舍IAQ。  相似文献   

8.
Indoor air quality (IAQ) of a restaurant has increasingly received a lot of public concerns in Hong Kong. Unfortunately, there is limited data about the IAQ of Hong Kong restaurants. In order to characterize the current IAQ of local restaurants, four restaurants in metropolitan Hong Kong including a Korean barbecue style restaurant, a Chinese hot pot restaurant, a Chinese dim sum restaurant and a Western canteen were selected for this study. The results of this study showed that the mean concentrations of CO2 at restaurants with gas stoves for food cooking in dining areas exceeded the range from 40 to 60% indoor CO2 concentrations at restaurants without gas stoves in dining areas. The average levels of PM10 and PM2.5 at the Korean barbecue style restaurant were as high as 1442 and 1167 microg/m3, respectively. At the Korean barbecue and Chinese hot pot restaurants, the levels of PM2.5 accounted for 80-93% of their respective PM10 concentrations. The 1-h average levels of CO observed at Korean barbecue style and hot pot restaurants were 15,100 and 8000 microg/m3, respectively. Relatively high concentrations of CO2, CO, PM10, PM2.5 benzene, toluene, methylene chloride and chloroform were measured in the dining areas of the Korean barbecue style and the Chinese hot pot restaurants. The operations of pan-frying food and boiling food with soup in a hot pot could generate considerable quantities of air pollutants.  相似文献   

9.
This study aimed at surveying lower secondary schools in southern Italy, in a highly polluted area. A community close to an industrial area and three villages in rural areas was investigated. Indoor temperature, relative humidity (RH), gaseous pollutants (CO2 and NO2), selected biological pollutants in indoor dust, and the indoor/outdoor mass concentration and elemental composition of PM2.5 were ascertained. Temperature and RH were within, or close to, the comfort range, while CO2 frequently exceeded the threshold of 1000 ppm, indicating inadequate air exchange rate. In all the classrooms, median NO2 levels were above the WHO threshold value. Dermatophagoides p. allergen concentration was below the sensitizing threshold, while high endotoxin levels were detected in the classrooms, suggesting schools may produce significant risks of endotoxin exposure. Concentration and solubility of PM2.5 elements were used to identify the sources of indoor particles. Indoor concentration of most elements was higher than outdoors. Resuspension was responsible for the indoor increase in soil components. For elements from industrial emission (Cd, Co, Ni, Pb, Sb, Tl, V), the indoor concentration depended on penetration from the outside. For these elements, differences in rural vs industrial concentrations were found, suggesting industrial sources may influence indoor air quality nearby schools.  相似文献   

10.
Dan Norbck 《Indoor air》1995,5(4):237-246
There is a growing concern about indoor air quality (IAQ) in schools. We have studied relations between subjective indoor air quality (SIAQ) and measured IAQ among school personnel (N = 97) in six mid-Swedish primary schools. Information on SIAQ and the psychosocial work environment was measured by a self-administered questionnaire, using analogue rating scales. Indoor exposures were quantified by hygienic measurements. Perception of high room temperature was related to a poor climate of cooperation, fleecy wall materials, and the concentration of volatile organic compounds (VOC), including xylene, limonene, and butanols. Perception of air dry-ness was related to atopy, work stress, poor climate of cooperation, high room temperature, low air humidity, and high VOC concentration, including, limonene, and n-alkanes. Perception of dusty air was related to work stress, the role of schoolteacher, and exposure to 2-ethyl-1-hexanol. No relations were found between SIAQ and CO2, building age, or respirable dust. To achieve a good SIAQ, room temperature should be kept at a maximum of 22°C, and exposure to VOCs and fleecy materials should be minimized. Finally, a sound psychosocial work climate is essential for the perception of a good physical indoor climate.  相似文献   

11.
Mi YH  Norbäck D  Tao J  Mi YL  Ferm M 《Indoor air》2006,16(6):454-464
We investigated 10 naturally ventilated schools in Shanghai, in winter. Pupils (13-14 years) in 30 classes received a questionnaire, 1414 participated (99%). Classroom temperatures were 13-21 degrees C (mean 17 degrees C), relative air humidity was 36-82% (mean 56%). The air exchange rate was 2.9-29.4 ac/h (mean 9.1), because of window opening. Mean CO2 exceeded 1000 ppm in 45% of the classrooms. NO2 levels were 33-85 microg/m3 indoors, and 45-80 microg/m3 outdoors. Ozone were 1-9 microg/m3 indoors and 17-28 microg/m3 outdoors. In total, 8.9% had doctors' diagnosed asthma, 3.1% wheeze, 23.0% daytime breathlessness, 2.4% current asthma, and 2.3% asthma medication. Multiple logistic regression was applied. Observed indoor molds was associated with asthma attacks [odds ratio (OR) = 2.40: P < 0.05]. Indoor temperature was associated with daytime breathlessness (OR = 1.26 for 1 C; P < 0.001), and indoor CO2 with current asthma (OR = 1.18 for 100 ppm; P < 0.01) and asthma medication (OR = 1.15 for 100 ppm; P < 0.05). Indoor NO2 was associated with current asthma (OR = 1.51 for 10 microg/m3; P < 0.01) and asthma medication (OR = 1.45 for 10 microg/m3; P < 0.01). Outdoor NO2 was associated with current asthma (OR = 1.44 for 10 microg/m3; P < 0.05). Indoor and outdoor ozone was negatively associated with daytime breathlessness. In conclusion, asthma symptoms among pupils in Shanghai can be influenced by lack of ventilation and outdoor air pollution from traffic. Practical Implications Most urban schools in Asia are naturally ventilated buildings, often situated in areas with heavy ambient air pollution from industry or traffic. The classes are large, and window opening is the only way to remove indoor pollutants, but this results in increased exposure to outdoor air pollution. There is a clear need to improve the indoor environment in these schools. Building dampness and indoor mold growth should be avoided, and the concept of mechanical ventilation should be introduced. City planning aiming to situate new schools away from roads with heavy traffic should be considered.  相似文献   

12.
长沙市某大学教室内外空气品质调查   总被引:4,自引:0,他引:4  
本文对长沙市某大学校园内三栋教学楼教室内外的空气品质进行了实地测量调查。在室内和室外同时对空气温度(Ta)、相对湿度(RH)、空气流速(V)以及二氧化碳(CO2)、一氧化碳(CO)、二氧化硫(SO2)、二氧化氮(NO2)、可吸入颗粒物(PM10)和甲醛(HCH0)等的浓度参数进行了测量。实地测量时间为2004年3月和4月两个月。测量结果显示CO2和PM10为典型大学教室中污染最为严重的两项指标:CO2的最高和平均浓度分别高达0.3229/0和0.1997%,而中国国家标准为0.100%。造成如此严重污染的主要原因是通风不足以及教室内人员密度过大;教室内PM10的最大和平均浓度分别为0.16mg/m^3和0.13mg/m^3,通过实验分析得出在室内人员密度不是非常大的情况下,室内PM10主要来自室外环境;而人员密度大到一定程度时,室内人员活动与PM10浓度则显示出了一定的正相关性。本文所测的其他污染指标均符合国家标准要求。并且在结论中也提出了一些解决问题的建议。  相似文献   

13.
Architects and engineers are beginning to consider a new dimension of indoor air: the structure and composition of airborne microbial communities. A first step in this emerging field is to understand the forces that shape the diversity of bioaerosols across space and time within the built environment. In an effort to elucidate the relative influences of three likely drivers of indoor bioaerosol diversity – variation in outdoor bioaerosols, ventilation strategy, and occupancy load – we conducted an intensive temporal study of indoor airborne bacterial communities in a high‐traffic university building with a hybrid HVAC (mechanically and naturally ventilated) system. Indoor air communities closely tracked outdoor air communities, but human‐associated bacterial genera were more than twice as abundant in indoor air compared with outdoor air. Ventilation had a demonstrated effect on indoor airborne bacterial community composition; changes in outdoor air communities were detected inside following a time lag associated with differing ventilation strategies relevant to modern building design. Our results indicate that both occupancy patterns and ventilation strategies are important for understanding airborne microbial community dynamics in the built environment.  相似文献   

14.
Research shows that poor indoor air quality (IAQ) in school buildings can cause a reduction in the students’ performance assessed by short-term computer-based tests; whereas good air quality in classrooms can enhance children's concentration and also teachers’ productivity. Investigation of air quality in classrooms helps us to characterise pollutant levels and implement corrective measures. Outdoor pollution, ventilation equipment, furnishings, and human activities affect IAQ. In school classrooms, the occupancy density is high (1.8–2.4 m2/person) compared to offices (10 m2/person). Ventilation systems expend energy and there is a trend to save energy by reducing ventilation rates. We need to establish the minimum acceptable level of fresh air required for the health of the occupants. This paper describes a project, which will aim to investigate the effect of IAQ and ventilation rates on pupils’ performance and health using psychological tests. The aim is to recommend suitable ventilation rates for classrooms and examine the suitability of the air quality guidelines for classrooms. The air quality, ventilation rates and pupils’ performance in classrooms will be evaluated in parallel measurements. In addition, Visual Analogue Scales will be used to assess subjective perception of the classroom environment and SBS symptoms. Pupil performance will be measured with Computerised Assessment Tests (CAT), and Pen and Paper Performance Tasks while physical parameters of the classroom environment will be recorded using an advanced data logging system. A total number of 20 primary schools in the Reading area are expected to participate in the present investigation, and the pupils participating in this study will be within the age group of 9–11 years. On completion of the project, based on the overall data recommendations for suitable ventilation rates for schools will be formulated.  相似文献   

15.
Indoor air quality (IAQ) in classrooms has a significant impact on children's academic performance, health, and well-being; therefore, understanding children's perception of IAQ is vital. This study investigates how children's perception of IAQ is affected by environmental variables and thermal sensation. In total, 29 naturally ventilated classrooms in eight UK primary schools were selected and 805 children were surveyed during non-heating and heating seasons. Results show that air sensation votes (ASVs) are more correlated to CO2 levels than to operative temperatures (Top) during non-heating seasons and more correlated to Top than CO2 levels during heating seasons. The impact of Top on ASVs decreases with an increase in CO2 levels, and the effect of CO2 levels on ASVs decreases with increase in Top. The most favorable ASVs are given when children feel “cool” and have “as it is” preference. By keeping CO2 < 1000 ppm and Top within children's thermal comfort band, ASVs are improved by 43%. The study recommends that standards should consider the impact of both temperature and CO2 levels on perceived IAQ. Perception of IAQ also affects children's overall comfort and tiredness levels; however, this influence is more significant on tiredness level than that on overall comfort level.  相似文献   

16.
Poor conditions leading to substandard indoor air quality (IAQ) in classrooms have been frequently cited in the literature over the past two decades. However, there is limited data linking poor IAQ in the classrooms to student performance. Whereas, it is assumed that poor IAQ results in reduced attendance and learning potential, and subsequent poor student performance, validating this hypothesis presents a challenge in today's school environment. This study explores the association between student performance on standardized aptitude tests that are administered to students on a yearly basis, to classroom carbon dioxide (CO2) concentrations, which provide a surrogate of ventilation being provided to each room. Data on classroom CO2 concentrations (over a 4-5 h time span within a typical school day) were recorded in fifth grade classrooms in 54 elementary schools within a school district in the USA. Results from this preliminary study yield a significant (P < 0.10) association between classroom-level ventilation rate and test results in math. They also indicate that non-linear effects may need to be considered for better representation of the association. A larger sample size is required in order to draw more definitive conclusions. Practical Implications Future studies could focus on (1) gathering more evidence on the possible association between classroom ventilation rates and students' academic performance; (2) the linear/non-linear nature of the association; and (3) whether it is possible to detect 'no observed adverse effect level' for adequate ventilation with respect to academic performance in schools. All of this information could be used to improve guidance and take regulatory actions to ensure adequate ventilation in schools. The high prevalence of low ventilation rates, combined with the growing evidence of the positive impact that sufficient ventilation has on human performance, suggests an opportunity for improving design and management of school facilities.  相似文献   

17.
The aim of this study was to characterize the relationship between Indoor Air Quality (IAQ) and ventilation in French classrooms. Various parameters were measured over one school week, including volatile organic compounds, aldehydes, particulate matter (PM2.5 mass concentration and number concentration), carbon dioxide (CO2), air temperature, and relative humidity in 51 classrooms at 17 schools. The ventilation was characterized by several indicators, such as the air exchange rate, ventilation rate (VR), and air stuffiness index (ICONE), that are linked to indoor CO2 concentration. The influences of the season (heating or non‐heating), type of school (nursery or elementary), and ventilation on the IAQ were studied. Based on the minimum value of 4.2 l/s per person required by the French legislation for mechanically ventilated classrooms, 91% of the classrooms had insufficient ventilation. The VR was significantly higher in mechanically ventilated classrooms compared with naturally ventilated rooms. The correlations between IAQ and ventilation vary according to the location of the primary source of each pollutant (outdoor vs. indoor), and for an indoor source, whether it is associated with occupant activity or continuous emission.  相似文献   

18.
Several studies have found that indoor air quality (IAQ) in schools is often poor and may affect the health of the pupils. Building ventilation is a means to reduce pollutants indoors, but different designs should be evaluated for their effectiveness in different environments. In a field experiment performed at four classrooms in one school building, air was supplied either in the mixing or in the displacement mode, and we collected information on exposures, pupils' perception of IAQ and climate, and health symptoms and performed clinical examinations. The room temperature, relative humidity, concentration of CO?, and cat allergen were measured at the breathing height and were similar during each ventilation mode. The children perceived IAQ were similar in the two ventilation regimes, and there were few differences in symptom reports or clinical parameters. However, the pupils reported more eye symptoms during displacement ventilation. PRACTICAL IMPLICATIONS: Both mixing and displacement ventilation may be appropriate in school classrooms as long as the overall design, ventilation rates, and maintenance of systems are satisfactory.  相似文献   

19.
Thermal conditions and indoor concentrations of aldehydes, volatile organic compounds (VOCs), and NO2 were investigated in 19 occupied temporary houses in 15 temporary housing estates constructed in Minamisoma City, Fukushima, Japan. The data were collected in winter, spring, and summer in January to July 2012. Thermal conditions in temporary log houses in the summer were more comfortable than those in pre‐fabricated houses. In the winter, the indoor temperature was uncomfortably low in all of the houses, particularly the temporary log houses. Indoor air concentrations for most aldehydes and VOCs were much lower than the indoor guidelines, except for those of p‐dichlorobenzene, acetaldehyde, and total VOCs. The indoor p‐dichlorobenzene concentrations exceeded the guideline (240 μg/m3) in 18% of the temporary houses, and the 10?3 cancer risk level (91 μg/m3) was exceeded in winter in 21% due to use of moth repellents by the occupants. Indoor acetaldehyde concentrations exceeded the guideline (48 μg/m3) in about half of the temporary houses, likely originating from the wooden building materials. Indoor NO2 concentrations in the temporary houses were significantly higher in houses where combustion heating appliances were used (0.17 ± 0.11 ppm) than in those where they were not used (0.0094 ± 0.0065 ppm).  相似文献   

20.
To improve indoor air quality and to protect public health, Taiwan has enacted the “Indoor Air Quality Act (IAQ Act)” in 2012. For the general public, the indoor air quality in hair salons is important because it is a popular location that people will often visit for hair treatments. However, only a few exposure assessments regarding air pollutants have previously been performed in hair salons. To assess the air quality of hairdressing environments in Taipei, ten hairdressing salons were included for a walk‐through survey in this study. In addition, the airborne concentrations of formaldehyde, volatile organic compounds (VOCs), CO2, and phthalate esters were also determined in 5 salons. Charcoal, XAD‐2, and OVS‐Tenax tubes were used for the air sampling, while the samples were analyzed with gas chromatography/mass spectrometer. It was found that the products used in hair salons contained various chemicals. In fact, from the walk‐through survey, a total of 387 different ingredients were found on 129 hair product labels. The hair salons were not well ventilated, with CO2 levels of 600 to 3576 ppm. The formaldehyde concentrations determined in this study ranged from 12.40 to 1.04 × 103 μg m?3, and the maximum level was above the permissible exposure limit (PEL) of US Occupational Safety and Health Administration (US OSHA). Additionally, 83% of the samples were with levels higher than the standard regulated by Taiwan's IAQ Act. The concentrations of VOCs and phthalate esters were below the occupational exposure limits (OELs), but higher than what was found in general residential environments. The hair products were considered as the major source of air pollutants because significantly higher concentrations were found around the working areas. The number of perming treatments, the number of workers, and the frequency of using formaldehyde releasing products, were found to be associated with the levels of formaldehyde. This study indicates that efforts are needed to improve the indoor air quality in hairdressing salons in Taipei.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号