Mi YH  Norbäck D  Tao J  Mi YL  Ferm M 《Indoor air》2006,16(6):454-464
We investigated 10 naturally ventilated schools in Shanghai, in winter. Pupils (13-14 years) in 30 classes received a questionnaire, 1414 participated (99%). Classroom temperatures were 13-21 degrees C (mean 17 degrees C), relative air humidity was 36-82% (mean 56%). The air exchange rate was 2.9-29.4 ac/h (mean 9.1), because of window opening. Mean CO2 exceeded 1000 ppm in 45% of the classrooms. NO2 levels were 33-85 microg/m3 indoors, and 45-80 microg/m3 outdoors. Ozone were 1-9 microg/m3 indoors and 17-28 microg/m3 outdoors. In total, 8.9% had doctors' diagnosed asthma, 3.1% wheeze, 23.0% daytime breathlessness, 2.4% current asthma, and 2.3% asthma medication. Multiple logistic regression was applied. Observed indoor molds was associated with asthma attacks [odds ratio (OR) = 2.40: P < 0.05]. Indoor temperature was associated with daytime breathlessness (OR = 1.26 for 1 C; P < 0.001), and indoor CO2 with current asthma (OR = 1.18 for 100 ppm; P < 0.01) and asthma medication (OR = 1.15 for 100 ppm; P < 0.05). Indoor NO2 was associated with current asthma (OR = 1.51 for 10 microg/m3; P < 0.01) and asthma medication (OR = 1.45 for 10 microg/m3; P < 0.01). Outdoor NO2 was associated with current asthma (OR = 1.44 for 10 microg/m3; P < 0.05). Indoor and outdoor ozone was negatively associated with daytime breathlessness. In conclusion, asthma symptoms among pupils in Shanghai can be influenced by lack of ventilation and outdoor air pollution from traffic. Practical Implications Most urban schools in Asia are naturally ventilated buildings, often situated in areas with heavy ambient air pollution from industry or traffic. The classes are large, and window opening is the only way to remove indoor pollutants, but this results in increased exposure to outdoor air pollution. There is a clear need to improve the indoor environment in these schools. Building dampness and indoor mold growth should be avoided, and the concept of mechanical ventilation should be introduced. City planning aiming to situate new schools away from roads with heavy traffic should be considered.  相似文献   

2.
Microorganisms are known to produce a range of volatile organic compounds, so-called microbial VOC (MVOC). Chamber studies where humans were exposed to MVOC addressed the acute effects of objective and/or subjective signs of mucosal irritation. However, the effect of MVOC on inhabitants due to household exposure is still unclear. The purpose of this epidemiological study was to measure indoor MVOC levels in single family homes and to evaluate the relationship between exposure to them and sick building syndrome (SBS). All inhabitants of the dwellings were given a self-administered questionnaire with standardized questions to assess their symptoms. Air samples were collected and the concentrations of eight selected compounds in indoor air were analyzed by gas chromatography/mass spectrometry — selective ion monitoring mode (GC/MS-SIM). The most frequently detected MVOC was 1-pentanol at a detection rate of 78.6% and geometric mean of 0.60 μg/m3. Among 620 participants, 120 (19.4%) reported one or more mucous symptoms; irritation of the eyes, nose, airway, or coughing every week (weekly symptoms), and 30 (4.8%) reported that the symptoms were home-related (home-related symptoms). Weekly symptoms were not associated with any of MVOC, whereas significant associations between home-related mucous symptoms and 1-octen-3-ol (per log10-unit: odds ratio (OR) 5.6, 95% confidence interval (CI): 2.1 to 14.8) and 2-pentanol (per log10-unit: OR 2.3, 95% CI: 1.0 to 4.9) were obtained after adjustment for gender, age, and smoking. Associations between home-related symptoms and 1-octen-3-ol remained after mutual adjustment. However, concentrations of the selected compounds in indoors were lower than the estimated safety level in animal studies. Thus, the statistically significant association between 1-octen-3-ol may be due to a direct effect of the compounds or the associations may be being associated with other offending compounds. Additional studies are needed to evaluate these possibilities.  相似文献   

3.
The aim was to study asthma and allergy in relation to diet and the school environment. Pupils (5-14 years) in eight schools received a questionnaire, 1014 participated (68%). Settled dust was collected on ALK-filters and analyzed for allergens from cat (Fel d 1), dog (Can f 1), horse (Equ cx), house dust mites (Der p 1, Der f 1), and cockroach (Bla g 1) by ELISA. In total, 6.8% reported cat allergy, 4.8% dog allergy, 7.7% doctor's diagnosed asthma and 5.9% current asthma, and 7.8% reported wheeze. Current asthma was less common among those consuming more fresh milk (P < 0.05) and fish (P < 0.01). Poly-unsaturated fatty acids was associated with more wheeze (P < 0.05), olive oil was associated with less doctors' diagnosed asthma (P < 0.05). Totally, 74% of the classrooms had mean CO(2) <1000 ppm. The median concentration per gram dust was 860 ng/g Fel d 1, 750 ng/g Can f 1 and 954 U/g Equ cx. Horse allergen was associated with more wheeze (P < 0.05), daytime breathlessness (P < 0.05), current asthma (P < 0.05) and atopic sensitization (P < 0.05). Dog allergen was associated with wheeze (P < 0.05) and daytime breathlessness (P < 0.05). The associations between allergens and respiratory symptoms were more pronounced among those consuming margarine, not consuming butter, and with a low intake of milk. In conclusion, cat, dog and horse allergens in schools could be a risk factor for asthma and atopic sensitization, and dietary factors may interact with the allergen exposure. PRACTICAL IMPLICATIONS: Previous school studies performed by us in mid-Sweden, showed that most classrooms did not fulfill the ventilation standards. In this study, most of the classrooms fulfilled the ventilation standard, but despite that had widespread allergen contamination. Most previous studies have focused on cat allergen, but our study has shown that also dog and horse allergens can be risk factors for asthma and allergy in schools. As allergens are transported from other environments, mainly the home environment, the main prevention should be to minimize transfer of allergens. This could be achieved by reducing contacts with furry pets and horses, or using different clothes at home and at school (e.g. school uniforms). Increased cleaning in the schools may reduce allergen levels, but the efficiency of this measure must be evaluated in further intervention studies. Finally, our study supports the view that dietary habits among pupils should not be neglected and interaction between dietary factors and indoor allergen exposure needs to be further investigated.  相似文献   

4.
Zhao ZH  Elfman L  Wang ZH  Zhang Z  Norbäck D 《Indoor air》2006,16(6):404-413
We compared the school environment, asthma and allergy in 10 schools in Taiyuan, China, with eight schools in Uppsala, Sweden. In total 2193 pupils (mean age 13 years) participated. Chinese pupils had more respiratory symptoms, particularly daytime breathlessness after exercise (29.8% vs. 7.1%; P < 0.001), while cat allergy (1.2% vs. 6.6%; P < 0.001) and dog allergy (1.3% vs. 4.0%; P < 0.01) was less common. Cumulative incidence of asthma (1.8% vs. 9.5%; P < 0.001) and doctor's diagnosed asthma (1.2% vs. 9.0%; P < 0.001) were less common in China, indicating an under-diagnosis of asthma. Chinese classrooms were colder (mean 14.7 vs. 21.4 degrees C), more humid (mean 42% vs. 31% RH) and had higher CO2-levels (mean 2211 vs. 761 ppm). Levels of cat (Fel d1), dog (Can f1) allergens were low in settled dust from China (< 200 ng/g dust), but high in airborne dust on Petri-dishes (GM 16.8 ng/m2/day for Fel d1 and 17.7 for Can f1). The Swedish settled dust contained cat, dog and horse allergens in high levels (median 1300 ng/g, 1650 ng/g, 1250 U/g dust, respectively). In conclusion, there were large differences in the school environment, and in respiratory symptom and allergy. Allergen measurements in settled dust only may largely underestimate the classroom exposure. Practical Implications There is a need to improve the school environment, both in China and Sweden. The Swedish schools contained high levels of cat, dog and horse allergens and more amounts of open shelves and textiles that can accumulate dust and allergens. The air measurements indicated that Chinese schools may contain significant amounts of cat and dog allergen, and analysis of settled dust only may not reflect the true allergen exposure. Since the Chinese schools had no mechanical ventilation, they could not fulfill the ventilation standard in winter, and hence there is a need for improving the ventilation. The great discrepancy between respiratory symptoms and reports on asthma, and the high prevalence of attacks of breathlessness without wheeze, may have implication for future questionnaire studies on asthma in China.  相似文献   

5.
A two stage intervention study was carried out to establish the degree to which a newly developed, electrostatic air cleaning (EAC) system can improve indoor air quality (IAQ) by reducing the number of airborne fine particles. The IAQ and how employees in a city centre office (49 m2) perceived it, was monitored from May until November 1998. The number of fine particles, PM3 (0.3-3.0 microm); number of coarse particles, PM7 (3.0-7.0 microm); number of small positive and negative air ions; relative humidity and temperature were recorded in and out of doors. To assess the employees' perception of any changes in their work environment, a questionnaire was completed. Number of particles, relative humidity and temperature were also recorded in a nearby office, equipped with an identical air processor, where no interventions were made. The results from the first intervention (Stage 1), comparing number of airborne particles outdoors to indoors, gave a 19% reduction for PM3 and a 67% reduction for PM7 (P < 0.001). The reduction in PM3 was inconsistent and not statistically significant (P = 0.3). The reduction in PM7 from outdoors and the removal of PM7 created indoors was achieved by optimizing the existing air moving equipment. The results from the second intervention (Stage 2--with EAC units installed) comparing indoor to outdoor values, gave a further reduction in PM3 of 21% (P < 0.001) and a further 3% reduction for PM7 (P > 0.05). Therefore, at the end of Stage 2, the total reductions in particles from outdoors to indoors were 40% for PM3 and 70% for PM7 (P < 0.001). The Stage 2 results strongly suggest that electrostatic forces, created by the EAC unit(s) improved the removal of PM3, with no further significant improvement in the reduction of PM7. The questionnaire indicated an improvement in the IAQ, as perceived by the employees. The results suggest that the EAC system is effective in reducing PM3 and thereby improving IAQ in an urban office.  相似文献   

6.
Literature has suggested association between damp environments, microbial exposure, and higher prevalence of respiratory symptoms and diseases. The study began by evaluating the airborne fungal concentrations at urban and suburban areas of a typical metropolitan city in southern Taiwan for the estimation of related health risks. A group of representative homes, based on the housing characteristics questionnaires completed earlier, were selected from two parts of the city; urban and suburban. Burkard sampler (BURKARD, Rickmansworth, England) was used to collect airborne fungi onto agar plates with malt-extract. After incubation and identification, concentrations of airborne fungi were calculated as CFU/m3. The geometric mean (GM) concentration for indoors was 8946 (4372-18,306) CFU/m3 in winter and 4381 (1605-11,956) in summer. For outdoors, it was 11,464 (5767-22,788) CFU/m3 in winter and 4689 (1895-11,603) in summer. In summer, the total fungal concentration, both indoors and outdoors of suburban homes, were significantly higher than those of urban homes. The dominant fungi contributing to such a difference were indoor Cladosporium spp. and outdoor Penicillium spp. (P < 0.01). The indoor/outdoor ratio (I/O) was similar in two areas except for Penicillium spp. in winter and Aspergillus spp. in summer; both higher in the suburban area. Significantly higher levels of airborne fungi were observed in this region than those seen in northern Taiwan or other parts of the world. Future investigations are needed to further examine the effects of these exposures on the related health problems.  相似文献   

7.
This study evaluated the interrelations between indoor and outdoor bioaerosols in a bedroom under a living condition. Two wideband integrated bioaerosol sensors were utilized to measure indoor and outdoor particulate matter (PM) and fluorescent biological airborne particles (FBAPs), which were within a size range of 0.5-20 μm. Throughout this one-month case study, the median proportion of FBAPs in PM by number was 19% (5%; the interquartile range, hereafter) and 17% (3%) for indoors and outdoors, respectively, and those by mass were 78% (12%) and 55% (9%). According to the size-resolved data, FBAPs dominated above 2 and 3.5 μm indoors and outdoors, respectively. Comparing indoor upon outdoor ratios among occupancy and window conditions, the indoor FBAPs larger than 3.16 μm were dominated by indoor sources, while non-FBAPs were mainly from outdoors. The occupant dominated the indoor source of both FBAPs and non-FBAPs. Under awake and asleep, count- and mass-based mean emission rates were 45.9 and 18.7 × 106 #/h and 5.02 and 2.83 mg/h, respectively. Based on indoor activities and local outdoor air quality in Singapore, this study recommended opening the window when awake and closing it during sleep to lower indoor bioaerosol exposure.  相似文献   

8.
Poor indoor air quality has been linked to the exacerbation of asthma symptoms in children. Because people spend most of their time indoors, improving indoor air quality may provide some relief to asthma sufferers. A study was conducted to assess whether operating an air cleaning/ventilating unit (HEPAiRx®) in a child's bedroom can improve his/her respiratory health. Thirty children diagnosed with asthma were randomly split into two groups. For the first six weeks, group A had the air cleaning/ventilating unit (HEPAiRx®) running in the bedrooms of the participants and group B did not; for the second six weeks, both groups had the cleaners running in the bedrooms; and, for the final six weeks, group A turned the cleaners off and group B kept theirs running. Indoor air quality parameters, including temperature, relative humidity, particulate matter (PM 0.5–10 μm), carbon monoxide, carbon dioxide and total volatile organic compound (TVOC) concentrations, were monitored in each bedroom using an AirAdvice indoor air quality multi-meter. As a measure of pulmonary inflammation, exhaled breath condensate (EBC) was collected every sixth day and analyzed for nitrate and pH. Peak expiratory flow (PEF) was also measured. PM and TVOC concentrations decreased with operation of the HEPAiRx an average of 72% and 59%, respectively. The EBC nitrate concentrations decreased significantly and the EBC pH and PEF values increased significantly with operation of the unit (p < 0.001 when comparing on/off sample means). These results indicate that air cleaning in combination with ventilation can effectively reduce symptoms for asthma sufferers.  相似文献   

9.
Abstract A total of 140 homes in the Po River Delta area of North Italy (near Venice) were monitored during summer and winter to measure the concentration of nitrogen dioxide (NO2), and respirable suspended particulate matter (RSP, ≤ 2.5 μm). In this paper, the findings on home characteristics, daily activity pattern of occupants, and residential indoor air quality are described. Our study confirms that people spend the greater part of their daily lives indoors (84%), especially at home (64%). The concentration of monitored pollutants was greater in winter than in summer. The highest levels of NO2 were found in the kitchens. Significantly higher indoor NO2 levels were found in the houses with gas-furnace heating and/or with gas water heater located inside the home. RSP was significantly higher in homes where tobacco smoking took place, and was significantly related to the number of cigarettes smoked. A significant relationship between NO2 indoor concentrations and RSP values in both seasons was found.  相似文献   

10.
The aim was to study possible relationships between personality traits as measured by the Karolinska Scales of Personality (KSP), a self-report personality inventory based on psychobiological theory, and medical symptoms, in subjects with previous work history in suspected sick buildings. The study comprised 195 participants from 19 consecutive cases of suspected sick buildings, initially collected in 1988-92. In 1998-89, the KSP inventory and a symptoms questionnaire were administered in a postal follow-up study. There were 16 questions on symptoms, including symptoms from the eyes, nose, throat, skin, and headache, tiredness, and a symptom score (SC), ranging from 0 to 16, was calculated. The questionnaire also requested information on personal factors, including age, gender, smoking habits, allergy and diagnosed asthma. The KSP ratings in the study group did not differ from the mean personality scale norm scores, calculated from an external reference group. Females had higher scores for somatic anxiety (P < 0.01), muscular tension (P < 0.001), psychic anxiety (P < 0.01), psychasthenia (P < 0.05), indirect aggression (P < 0.05), and guilt (P < 0.05), while males scored higher on detachment (P < 0.001). Subjects with higher SC were found to display higher degree of somatic anxiety (P < 0.001), muscular tension (P < 0.001), psychic anxiety (P < 0.001), psychasthenia (P < 0.001), inhibition of aggression (P < 0.05), detachment (P < 0.05), suspicion (P < 0.01), indirect aggression (P < 0.01), and verbal aggression (P < 0.05). In addition, ocular, respiratory, dermal, and systemic symptoms (headache and tiredness) were significantly related to anxiety- and aggressivity-related scales. There were associations between personality scales and change of symptom score (SC) during the 9-year period. The associations between KSP personality traits and symptoms were more pronounced in females. In conclusion, there are gender differences in personality and SBS symptoms. Personality may play a role in the occurrence of symptoms studied in indoor environmental epidemiology. Our results support a view that measurement of personality could be of value in future studies and vulnerability to environmental stress. PRACTICAL IMPLICATIONS: Personality and personal vulnerability should be considered in both indoor environmental epidemiology and practical handling of building with suspected indoor problem, especially when the technical investigations fail to identify any obvious technical malfunction. Moreover, personality aspects should be considered among subjects with possible vulnerable personality exposed to environmental stress, and personality diagnosis can be a complementary tool useful when assessing 'sick building patients' in the medical services. We found no evidence of severe personality pathology in among those working in workplaces with environmental problems so called 'sick buildings'.  相似文献   

11.
Effect of inhaled formaldehyde on learning and memory of mice   总被引:1,自引:0,他引:1  
Lu Z  Li CM  Qiao Y  Yan Y  Yang X 《Indoor air》2008,18(2):77-83
In this study, we investigated the effect of inhaled formaldehyde on learning and memory capacity. After exposure to 0 (control), 1 and 3 mg/m(3) of gaseous formaldehyde respectively, the behavior of mice in a Morris water maze, the expression of NR1, NR2B mRNA and oxidative damage levels in mice brain were analyzed. The water maze performance, the activities of dismutase superoxide (SOD) and levels of glutathione (GSH) decreased significantly in 3 mg/m(3) group (P < 0.01, compared with control group); while malondialdehyde (MDA) contents and expression of NR1 and NR2B genes increased significantly after exposure to 3 mg/m(3) of gaseous formaldehyde (P < 0.05, <0.01, <0.01, compared with control group). These findings indicate that inhaled formaldehyde negatively affects learning and memory at 3 mg/m(3) of gaseous formaldehyde but not at lower levels. Oxidative stress-induced neuron damages in the brain may be the possible mechanism for these effects. PRACTICAL IMPLICATIONS: This study indicates that inhaled formaldehyde starts to negatively affect learning and memory at a middle concentration of formaldehyde without interference of other indoor air pollutants. Oxidative damage, and the alteration of NMDA receptor expression, which were induced by formaldehyde inhalation, may be the possible mechanism for gaseous formaldehyde-induced neurotoxicity.  相似文献   

12.
Most of human exposure to atmospheric pollutants occurs indoors, and the components of outdoor aerosols may have been changed in the way before reaching indoor spaces. Here we conducted real-time online measurements of mass concentrations and chemical composition of black carbon and the non-refractory species in PM2.5 in an occupied office for approximately one month. The open-close windows and controlled dampness experiments were also performed. Our results show that indoor aerosol species primarily originate from outdoors with indoor/outdoor ratio of these species typically less than unity except for certain organic aerosol (OA) factors. All aerosol species went through filtration upon transport indoors. Ammonium nitrate and fossil fuel OA underwent evaporation or particle-to-gas partitioning, while less oxidized secondary OA (SOA) underwent secondary formation and cooking OA might have indoor sources. With higher particulate matter (PM) mass concentration outdoors than in the office, elevated natural ventilation increased PM exposure indoors and this increased exposure was prolonged when outdoor PM was scavenged. We found that increasing humidity in the office led to higher indoor PM mass concentration particularly more oxidized SOA. Overall, our results highlight that indoor exposure of occupants is substantially different from outdoor in terms of mass concentrations and chemical species.  相似文献   

13.
The concentration of ultrafine particles (0.01 to greater than 1 microm) was measured in some rural and urban areas of Sweden and Denmark. The instruments used are handheld real-time condensation particle counters, models CPC 3007 and P-Trak 8525, both manufactured by TSI. Field measurements in Sweden were conducted in a few residential and office buildings, while in Denmark the measurement sites comprised two office buildings, one of them located in a rural area. The concentration of UFPs was measured simultaneously indoors and outdoors with condensation particle counters. The results revealed that the outdoor-generated particle levels were major contributors to the indoor particle number concentration in the studied buildings when no strong internal source was present. The results showed that in office buildings, the UFP concentrations indoors were typically lower and correlated fairly well to the number concentration outdoors. The determined indoor-outdoor ratios varied between 0.5 and 0.8. The indoor levels of UFPs in offices where smoking is allowed was sometimes recorded higher than outdoor levels, as in one of the Danish offices. In residential buildings, the indoor number concentration was strongly influenced by several indoor activities, e.g., cooking and candle burning. In the presence of significant indoor sources, the indoor/outdoor (IO) ratio exceeded unity. The magnitude of UFP concentrations was greater in the large city of Copenhagen compared to the medium-size city of Gothenburg and lowest at more rural sites.  相似文献   

14.
This work aims to characterize levels and phase distribution of polycyclic aromatic hydrocarbons (PAHs) in indoor air of preschool environment and to assess the impact of outdoor PAH emissions to indoor environment. Gaseous and particulate (PM1 and PM2.5) PAHs (16 USEPA priority pollutants, plus dibenzo[a,l]pyrene, and benzo[j]fluoranthene) were concurrently sampled indoors and outdoors in one urban preschool located in north of Portugal for 35 days. The total concentration of 18 PAHs (ΣPAHs) in indoor air ranged from 19.5 to 82.0 ng/m3; gaseous compounds (range of 14.1–66.1 ng/m3) accounted for 85% ΣPAHs. Particulate PAHs (range 0.7–15.9 ng/m3) were predominantly associated with PM1 (76% particulate ΣPAHs) with 5‐ring PAHs being the most abundant. Mean indoor/outdoor ratios (I/O) of individual PAHs indicated that outdoor emissions significantly contributed to PAH indoors; emissions from motor vehicles and fuel burning were the major sources.  相似文献   

15.
16.
The market for water-based paints (WBP) is growing, and these paints are favoured due to their low emission of volatile organic compounds (VOC). Because of the risk for microbial growth, biocides are usually added to WBP. Our study aimed to measure exposure to VOCs potentially of microbial origin (MVOC), during indoor application of typical Scandinavian WBP. Low concentrations of three MVOCs, 3-methyl-furan, 1-octen-3-ol, and 2-octen-1-ol, were detected during 5 out of 20 painting operations (25%). Mean exposures to MVOC and TVOC were 0.15 and 5000 μg/m3, respectively. No relation between MVOC and TVOC was observed. The highest exposure to MVOC was measured from an ecological paint, claimed to be low in VOCs and chemical additives. The results suggest that microbial growth in WBP may occur, and that measurements of MVOCs could be used as a means of quality control for WBP. The use of biocides in paint should be guided by the principle of a balance between the risk of contact allergies or other possible health hazards from the biocides, and the risk of microbial growth. If microbial growth occurs in paint, it may cause both unpleasant odor and potential health hazards for house painters and dwellers.  相似文献   

17.
Indoor air quality (IAQ) has been a matter of public concern these days whereas air pollution is normally monitored outdoors as part of obligations under the National air quality strategies. Much little is known about levels of air pollution indoors. Simultaneous measurements of indoor and outdoor carbon monoxide (CO) and oxides of nitrogen (NO and NO2) concentrations were conducted at three different environments, i.e. rural, urban and roadside in Agra, India, using YES - 205 multigas monitor during the winter season, i.e. October 2002-February 2003. A statistical correlation analysis of indoor concentration levels with outdoor concentrations was carried out. CO was maximum at roadside locations with indoor concentrations 2072.5 +/- 372 p.p.b. and outdoor concentrations 1220 +/- 281 p.p.b. (R2 = 0.005). Oxides of nitrogen were found maximum at urban site; NO concentration was 385 +/- 211 and 637 +/- 269 p.p.b. for indoors and outdoors respectively (R2 = 0.90792), where as NO2 concentration was 255 +/- 146 p.p.b. for indoors and 460 +/- 225 p.p.b. for outdoors (R2 = 0939464). Although indoor concentration at all the houses of the three sites have a positive correlation with outdoor concentration, CO variation indoors was very less due to outdoor sources. An activity schedule of inside and outside these homes were also prepared to see its influence and concentrations of pollutants. As standards for indoor air were not available for the Indian conditions these were compared with the known standards of other countries, where as outdoor concentrations were compared with the standards given by the Central Pollution Control board, which shows that indoor concentrations of both NO(x) and CO lie below permissible limits but outdoor concentrations of NO(x) cross the standard limits. PRACTICAL IMPLICATIONS: 'India currently bears the largest number of indoor air pollution (IAP) related health problems in world. An estimated 500,000 women & children die in India each year due to IAP-related cause--this is 25% of estimated IAP-related deaths worldwide. This study will be useful for policy makers, health related officials, academicians and Scientists who have interest in countries of developing world'.  相似文献   

18.
Outdoor particulate matter (PM(10)) is associated with detrimental health effects. However, individual PM(10) exposure occurs mostly indoors. We therefore compared the toxic effects of classroom, outdoor, and residential PM(10). Indoor and outdoor PM(10) was collected from six schools in Munich during teaching hours and in six homes. Particles were analyzed by scanning electron microscopy and X-ray spectroscopy (EDX). Toxicity was evaluated in human primary keratinocytes, lung epithelial cells and after metabolic activation by several human cytochromes P450. We found that PM(10) concentrations during teaching hours were 5.6-times higher than outdoors (117 ± 48 μg/m(3) vs. 21 ± 15 μg/m(3), P < 0.001). Compared to outdoors, indoor PM contained more silicate (36% of particle number), organic (29%, probably originating from human skin), and Ca-carbonate particles (12%, probably originating from paper). Outdoor PM contained more Ca-sulfate particles (38%). Indoor PM at 6 μg/cm(2) (10 μg/ml) caused toxicity in keratinocytes and in cells expressing CYP2B6 and CYP3A4. Toxicity by CYP2B6 was abolished with the reactive oxygen species scavenger N-acetylcysteine. We concluded that outdoor PM(10) and indoor PM(10) from homes were devoid of toxicity. Indoor PM(10) was elevated, chemically different and toxicologically more active than outdoor PM(10). Whether the effects translate into a significant health risk needs to be determined. Until then, we suggest better ventilation as a sensible option. PRACTICAL IMPLICATIONS: Indoor air PM(10) on an equal weight base is toxicologically more active than outdoor PM(10). In addition, indoor PM(10) concentrations are about six times higher than outdoor air. Thus, ventilation of classrooms with outdoor air will improve air quality and is likely to provide a health benefit. It is also easier than cleaning PM(10) from indoor air, which has proven to be tedious.  相似文献   

19.
Abstract Staphylococcus aureus was used as an indicator to study the origin and spread of microbial aerosol in and around chicken houses. Air samples indoor, upwind (10 and 50 m), and downwind (10, 50, 100, 200, and 400 m) of four chicken houses were collected using Andersen‐6 stages sampler. The concentrations of S. aureus were determined for every sample site. Isolation of S. aureus from chicken feces was performed according to the standard method. The genetic relationship among the isolates was determined by profiles of PCR‐amplified repetitive extragenic palindromic (REP‐PCR) elements. The results showed that the concentrations of S. aureus indoor of four chicken houses were higher than those upwind and downwind sites (P < 0.05 or P < 0.01), but there were no significant concentration differences among downwind sites (P > 0.05). The fingerprints and the phylogenetic tree indicated that a part of the S. aureus (55.6%, 10/18) isolates from indoor air had the same REP‐PCR fingerprints as feces isolates. Consequently, most isolates (57.1%, 20/35) from downwind 10, 50, 100, 200, even 400 m had the same REP‐PCR fingerprints as those from indoor or feces. These data indicated that some isolates from downwind and indoor originated from the chicken feces. However, those isolates from upwind had low similarity (similarity index 0.6–0.87) to those from indoor or feces. Therefore, the isolates upwind were not from the chicken feces or indoor. These results suggest that microbes in chicken feces can be aerosolized and spread indoor and outdoor, especially to downwind of the chicken houses. It should have an important epidemiological and public health significance.

Practical Implications

Thus, the use of S. aureus as an indicator to study the origin and spread of airborne pathogens from chicken houses is potentially useful for enhancing public health and understanding the airborne epidemiology of this pathogen. Meanwhile it can provide evidence for studying the spreading model of airborne pathogens.
  相似文献   

20.
We examined the associations between biomarkers of allergy and inflammation, indoor environment in dwellings, and incidence and remission of symptoms included in the sick building syndrome (SBS) and changes in the home environment of 452 adults who were followed from 1992 to 2002 within the Uppsala part of the European Community Respiratory Health Survey (ECRHS). The 10-year incidence (onset) of general, mucosal, and dermal symptoms was 8.5%, 12.7%, and 6.8%, respectively. Dampness or indoor molds at baseline was a predictor of incidence of general (relative risk [RR] = 1.98), mucosal (RR = 2.28), and dermal symptoms (RR = 1.91). Women had higher incidence of general (RR = 1.74) and mucosal symptoms (RR = 1.71). Indoor painting increased the incidence of general symptoms (RR = 1.62). Bronchial responsiveness (BR), eosinophil counts in blood, total IgE and eosinophilic cationic protein (ECP) in serum at baseline were predictors of incidence of SBS. At follow-up, BR, total IgE, and C-reactive protein (CRP ) were associated with increased incidence of SBS. Moreover, subjects with doctor-diagnosed asthma at baseline had a higher incidence of general (RR = 1.65) and mucosal symptoms (RR = 1.97). In conclusion, female gender, dampness or indoor molds, indoor painting, and biomarkers of allergy and inflammation were associated with a higher incidence of SBS symptoms, in particular mucosal symptoms. PRACTICAL IMPLICATIONS: The focus in Sweden on indoor environment issues over the last few decades has resulted in improvements in dwellings, and reduced tobacco smoking, which could be beneficial for public health. Reducing dampness and molds in the dwelling place is another important way of reducing occurrence of SBS symptoms in the general adult population. The association between the incidence of SBS symptoms and clinical biomarkers of allergy and inflammation suggests a common etiology between inflammatory diseases, including asthma, rhinitis, and SBS. Lastly, good agreement between self-reported and clinically diagnosed atopy indicates that questionnaire data on atopy can be used in epidemiological studies.  相似文献   