首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
In this paper a procedure for analytical prediction of joint shear strength of interior beam-column joints, strengthened with externally bonded fiber-reinforced polymer (FRP) sheets, has been presented. The procedure is based on the formulation available in the literature. To implement the available formulation for shear capacity prediction a computer program has been developed. Using this program shear capacity of the joint and joint shear stress variation at various stages of loading have been predicted and compared with experimental observations; presented in Part I of this study. Predictions show good agreement with experimental test results. The formulation is further extended to predict diagonal tensile stresses in the joint. The effectiveness of FRP quantity on joint shear strength and on various strains has been studied on parametric basis. It is observed that even a low quantity of FRP can enhance shear capacity of the joint significantly and its effectiveness can be further increased if debonding is suppressed (e.g., through mechanical anchorages). Effect of column axial load on shear strength of the joint has also been studied. It is observed that axial load increases the confinement of the joint core, which in turn increases the shear capacity of the joint.  相似文献   

2.
Shear failure of exterior beam-column joints is identified as the principal cause of collapse of many moment-resisting frame buildings during recent earthquakes. Effective and economical strengthening techniques to upgrade joint shear resistance and ductility in existing structures are needed. In this paper, efficiency and effectiveness of carbon fiber-reinforced polymer (CFRP) sheets in upgrading the shear strength and ductility of seismically deficient exterior beam-column joints have been studied. Four as-built joints were constructed with nonoptimal design parameters (inadequate joint shear strength with no transverse reinforcement) representing preseismic code design construction practice of joints and encompassing most of existing beam-column connections. Out of these four as-built specimens, two specimens were used as baseline specimens (control specimens) and other two were strengthened with CFRP sheets under two different schemes (strengthened specimens). In the first scheme, CFRP sheets were epoxy bonded to joint, beams, and part of the column regions. In the second scheme, however, sheets were epoxy bonded to joint region only but they were effectively prevented against any possible debonding through mechanical anchorages. All of these four subassemblages were subjected to cyclic lateral load histories so as to provide the equivalent of severe earthquake damage. The damaged control specimens were then repaired by filling their cracks through epoxy and externally bonding them with CFRP sheets under the same above two schemes. These repaired specimens were subjected to the similar cyclic lateral load history and their response histories were obtained. Response histories of control, repaired, and strengthened specimens were then compared. The results were compared through hysteretic loops, load-displacement envelopes, column profiles, joint shear distortion, ductility, and stiffness degradation. The comparison shows that CFRP sheets are very effective in improving shear resistance and deformation capacity of the exterior beam-column joints and delaying their stiffness degradation.  相似文献   

3.
In this paper, the efficiency and effectiveness of carbon-fiber-reinforced polymer (CFRP) sheets for upgrading the shear strength and ductility of a seismically deficient exterior beam-column joint were studied and compared with an American Concrete Institute (ACI)-based design joint specimen. One as-built joint specimen, representing the preseismic code design and construction practice for joints and one ACI-based design joint specimen, satisfying the seismic design requirements of the current code of practice were cast. The as-built specimen was used as baseline (control) specimen. These two specimens (i.e., the as-built control and the ACI-based specimens) were subjected to cyclic lateral load histories to induce damage equivalent to damage expected from a severe earthquake. The damaged control specimen was then repaired by filling its cracks with epoxy and externally bonding CFRP sheets to the joint, the beam, and part of the column regions. This specimen was identified as the repaired specimen. The repaired specimen was subjected to a similar cyclic lateral load history, and its response history was recorded. The response histories of the as-built control, the repaired, and the ACI-based design specimen were then compared. The test results demonstrated that externally bonded CFRP sheets can effectively improve both the shear strength and the deformation capacity of seismically deficient and damaged beam-column joints to a state comparable to the ACI-based design joint.  相似文献   

4.
In this paper, efficiency and effectiveness of carbon fiber reinforced polymers (CFRPs) in upgrading the shear strength and ductility of seismically deficient corner or knee reinforced concrete beam-column joints have been studied. For this purpose, four as-built corner/knee joints were constructed with no transverse reinforcement, representing extreme case of preseismic code design construction practice of joints and encompassing many existing beam-column corner joints. Out of these four as-built specimens, two specimens were used as baseline specimens (control specimens) and other two were strengthened with CFRP sheets under two different schemes (strengthened specimens). In the first scheme, CFRP sheets were epoxy bonded to joint, beams, and part of the column regions. In the second scheme, however, sheets were epoxy bonded to joint region only but they were effectively prevented against any possible debonding through mechanical anchorages. All these four subassemblages were subjected to cyclic lateral load histories to simulate loading due to earthquake and provide the equivalent of severe earthquake damage. The damaged control specimens were then repaired by filling their cracks through epoxy and externally bonding them with CFRP sheets under the same above two schemes. These repaired specimens were subjected to the similar cyclic lateral load history and their response histories were obtained. Response histories of control, repaired, and strengthened specimens were then compared. The results were compared through hysteretic loops, load-displacement envelopes, column profiles, ductility, and stiffness degradation. The comparison shows that CFRP sheets are very effective in improving shear resistance and deformation capacity of the corner beam-column joints and delaying their stiffness degradation. Shear capacities of control, repaired, and strengthened specimens were also predicted using writers’ published formulation. The predicted shear capacities were in a good agreement with the experimental values.  相似文献   

5.
A considerable amount of research has been directed recently toward understanding and promoting the use of externally applied fiber-reinforced polymer (FRP) for the seismic retrofit of reinforced concrete (RC) structures. In this paper, a comprehensive review and synthesis of published experimental studies on the seismic rehabilitation of RC frame beam-column joints with FRP is presented, and the issues that need to be addressed for further research are discussed. In addition, the paper presents a simple design model for predicting the contribution of the FRP to the shear strength of retrofitted joints. The key element in the model is the derivation of an expression for the effective FRP strain, based on the calibration of test data reported in the literature. A total of 54 tests carried out worldwide were considered in the review, and a database of the published studies, encompassing all relevant design parameters, was assembled. The reported test results confirm the structural effectiveness of the FRP strengthening technique for the seismic retrofit of RC joints. However, there are some gaps which need to be addressed. For instance, there is a lack of a rationale explanation of the resistance mechanisms involved in the beam-column joints retrofitted with FRP. Such a rational explanation is a prerequisite for the development of more comprehensive and rigorous design procedure.  相似文献   

6.
The results of a comprehensive experimental program, aimed at providing a fundamental understanding of the behavior of shear-critical exterior reinforced concrete (RC) joints strengthened with fiber reinforced polymers (FRP) under simulated seismic load, are presented in this study. The role of various parameters on the effectiveness of FRP is examined through 2/3-scale testing of 18 exterior RC joints. Conclusions are drawn on the basis of certain load versus imposed displacement response characteristics, comprising the strength (maximum lateral load), the stiffness, and the cumulative energy dissipation capacity. The results demonstrate the important role of mechanical anchorages in limiting premature debonding, and they provide important information on the role of various parameters, including: area fraction of FRP; distribution of FRP between the beam and the column; column axial load; internal joint (steel) reinforcement; initial damage; carbon versus glass fibers; sheets versus strips; and effect of transverse beams.  相似文献   

7.
An experimental research program is described regarding the use of externally applied carbon fiber-reinforced plastic (CFRP) jackets for seismic rehabilitation of reinforced concrete interior beam-column joints, which were designed for gravity loads. The joints had steel reinforcement details that are known to be inadequate by current seismic codes in terms of joint shear capacity due to the absence of transverse steel hoops and bond capacity of beam bottom steel reinforcing bars at the joint. Lap splicing of beam bottom steel reinforcement at the joint using externally applied longitudinal CFRP composite laminates is investigated. Improvement of joint shear capacity using diagonal CFRP composite laminates is another strengthening scheme employed. Concrete crack widths for the as-built specimens and the extent of CFRP delamination for the rehabilitated specimens at various drift ratios are reported. The test results indicate that CFRP jackets are an effective rehabilitation measure for improving the seismic performance of existing beam-column joints with inadequate seismic details in terms of increased joint shear strength and inelastic rotation capacity. In addition, CFRP laminates are effective rehabilitation measures for overcoming problems associated with beam bottom steel bars that have inadequate embedment into the beam-column joints.  相似文献   

8.
To prevent the casualties that can result from the collapse of earthquake-damaged structures, it is important that structures be rehabilitated as soon as possible. This paper proposes a rapid rehabilitation scheme for repairing moderately damaged reinforced concrete (RC) beam-wide column joints. Four nonseismically detailed interior beam-wide column joints were used as control specimens. All four subassemblages were subjected to similar cyclic lateral displacement to provide the equivalent of severe earthquake damage. The damaged control specimens were then repaired by filling their cracks with epoxy and externally bonding them with carbon-fiber-reinforced polymer (CFRP) sheets and glass-fiber-reinforced polymer (GFRP) sheets. These repaired specimens were then retested and their performance compared with that of the control specimens. This paper demonstrates that the repair of damaged RC beam-wide column joints by using FRP can restore the performance of damaged RC joints with relative ease, suggesting that the repair of beam-column joints is a cost-effective alternative to complete demolition and replacement  相似文献   

9.
Behavior of FRP Strengthened Infill Walls under In-Plane Seismic Loading   总被引:1,自引:0,他引:1  
The present paper investigates the suitability and effectiveness of fiber-reinforced polymers (FRP) in strengthening and/or repairing unreinforced masonry infill walls in reinforced concrete frames which are subjected to in-plane seismic/cyclic loading. For this purpose, a detailed experimental program was conducted. Specimen geometry, test setup, instrumentation, and a loading procedure that simulates earthquake loading are presented in a detailed fashion. Results of experimental observations are discussed in the form of load-displacement hysteretic loops and envelopes; column profiles; strain diagrams, and wall shear distortion. The test results, in general, indicate that the use of glass FRP (GFRP) sheets as strengthening materials provides a degree of enhancement to the infill wall, upgrades its deformation capacity, and makes the wall work as one unit. These results thus show great potential for externally bonded GFRP sheets in upgrading and strengthening the infill walls under in-plane seismic loads.  相似文献   

10.
Most research on semirigid jointed frames include only the rotational flexibility of the joint without consideration of the flexibility in the direction of the shear force. This paper investigates the nonlinear frictional behavior of a bolted slotted joint which includes flexibility in the tangential direction. The contact behavior at the end of the slot is also studied. The joint is prestressed with axial tension in the bolt shank. A virtual connection spring element is included at the intersection point between the beam and the column members. The formulation of the hybrid beam-column element including the end springs is presented, and the elemental matrices are also given for easy and direct implementation into finite-element analysis for static and/or dynamic loading.  相似文献   

11.
Analytical models are presented in this study for the analysis of reinforced concrete joints strengthened with composite materials in the form of externally bonded reinforcement comprising unidirectional strips or flexible fabrics. The models provide equations for stresses and strains at various stages of the response (before or after yielding of the beam or column reinforcement) until the ultimate capacity is reached, defined by concrete crushing or fiber-reinforced polymer (FRP) failure due to fracture or debonding. Solutions to these equations are obtained numerically. The models provide useful information on the shear capacity of FRP-strengthened joints in terms of the quantity and configuration of the externally bonded reinforcement and may be used to design FRP patching for inadequately detailed beam-column joints. A number of case studies are examined in this article, indicating that even low quantities of FRP materials may provide significant enhancement of the shear capacity. The effectiveness of external reinforcement increases considerably if debonding is suppressed and depends heavily on the distribution of layers in the beam and column. The latter depends on the relative quantities of steel reinforcement crossing the joint panel and the level of axial load in the column. Analytical shear strength predictions were in good agreement with test results found in the literature, thus adding confidence to the validity of the proposed models.  相似文献   

12.
Most of the experimental studies available in literature on the seismic assessment and retrofit of existing, poorly detailed, reinforced concrete (RC) beam-column joints, typical of pre-1970s construction practice, have concentrated on the two-dimensional (2D) response, using unidirectional cyclic loading testing protocol and constant axial load. Even more limited information is available on the performance of exterior (corner) three-dimensional (3D) RC beam-column joints with substandard detailing subjected to bidirectional loading regime. In this study, the results of a comprehensive experimental program is presented, aiming to show the effects of varying axial and bidirectional loading on the seismic performance of deficient exterior RC beam-column joints before and after retrofit. Ten exterior beam-column joint subassemblies are tested, including four as-built specimens and six retrofitted specimens using externally bonded glass fiber-reinforced polymer (GFRP) sheets. Test results are herein presented and conclusions are drawn on the basis of the observed global and local performance. The significance of the triaxial interaction of varying axial and bidirectional loading effects on the response of retrofitted corner joints is confirmed by the experimental findings. The proposed retrofit solution was shown to be capable of re-establishing an appropriate hierarchy of strength within the subassembly, protecting the panel zone region from shear failure while promoting the formation of a plastic hinge in the beam.  相似文献   

13.
Jacketing is less effective to large square/rectangular RC columns due to the inability of the rectangular-shaped jacket in restraining the dilation of concrete in the middle of a straight side. A new retrofit method is proposed in this work by fiber reinforcing the surface concrete in the middle of a straight side. Fiber reinforcing is achieved by inserting small fiber-reinforced polymer (FRP) bars into the concrete in the plastic hinge zone. The inserted FRP bars act as horizontal reinforcement to increase the ductility of the concrete in a similar way as that in normal fiber-reinforced concrete. When this fiber reinforcing technique is combined with the conventional jacketing, the concrete in all parts of a cross section may be effectively confined. In this work, experimental tests were undertaken to investigate the effectiveness of this new retrofit technique. Six half-scaled columns were tested and the test results demonstrated the effectiveness of the method.  相似文献   

14.
In 2003, an experimental research program was initiated at the American University of Beirut with the objectives of (1) evaluating the effectiveness of external fiber-reinforced polymer (FRP) confinement in improving the bond strength of spliced reinforcement in reinforced-concrete (RC) columns and its implications on the lateral load capacity and ductility of the columns under seismic loading; and (2) establishing rational design criteria for bond strengthening of spliced reinforcement using external FRP jackets. This paper presents a discussion of recent experimental results dealing with rectangular columns and the results of a pilot study conducted on circular columns with particular emphasis on aspects related to the bond strength of the spliced column reinforcement. A nonlinear analysis model is developed for predicting the envelope load–drift response, taking into account the effect of FRP confinement on the stress–strain behavior of concrete in compression. Results predicted by the model showed excellent agreement with the test results. Design expressions of the bond strength of spliced bars in FRP-confined concrete were assessed against the current experimental data, and a criterion for seismic FRP strengthening of bond-critical regions in RC members is proposed.  相似文献   

15.
Recent earthquakes have shown the vulnerability of unreinforced masonry (URM) buildings, which have led to an increasing demand for techniques to upgrade URM buildings. Fiber reinforced polymer (FRP) can provide an upgrading alternative for URM buildings. This paper presents results of dynamic tests investigating the in-plane behavior of URM walls upgraded with FRP (URM-FRP). These tests represent pioneer work in this area (dynamic and in-plane). Five half-scale walls were built, using half-scale brick clay units, and upgraded on one face only. Two moment/shear ratios (1.4 and 0.7), two mortar types (M2.5 and M9), three composite materials (carbon, aramid, and glass), three fiber structures (plates, loose fabric, and grids), and two upgrading configurations (diagonal “X” and full surface shapes) were investigated. The test specimens were subjected to a series of synthetic earthquake motions with increasing intensities on a uniaxial earthquake simulator. The tests validate the effectiveness of the one side upgrading: the upgrading technique improved the lateral resistance of the URM walls by a factor ranging from 1.3 to 2.9; however, the improvement in the lateral drift was less significant. Moreover, no uneven response was observed during the test due to the single side upgrading. Regarding the upgrading configurations, the bidirectional surface type materials (fabrics and grids) applied on the entire surface of the wall (and correctly anchored) can help postpone the three classic failure modes of masonry walls: rocking (“flexural failure”), step cracking, and sliding (“shear failures”). Additionally, in some situations, they will postpone collapse by “keeping the bricks together” under large seismic deformations. On the other hand, the diagonal “X” shape was less successful and premature failure was developed during the test.  相似文献   

16.
The behavior of seven one-half scale masonry specimens before and after retrofitting using fiber-reinforced polymer (FRP) is investigated. Four walls were built using one-half scale hollow clay masonry units and weak mortar to simulate walls built in central Europe in the mid-20th century. Three walls were first tested as unreinforced masonry walls; then, the seismically damaged specimens were retrofitted using FRPs. The fourth wall was directly upgraded after construction using FRP. Each specimen was retrofitted on the entire surface of a single side. All the specimens were tested under constant gravity load and incrementally increasing in-plane loading cycles. The tested specimens had two effective moment/shear ratio, namely, 0.5 and 0.7. The key parameter was the amount of FRP axial rigidity, which is defined as the amount of FRP reinforcement ratio times its E modulus. The single-side retrofitting/upgrading significantly improved the lateral strength, stiffness, and energy dissipation of the test specimens. The increase in the lateral strength was proportional to the amount of FRP axial rigidity. However, using high amount of FRP axial rigidity led to very brittle failure. Finally, simple existing analytical models estimated the ultimate lateral strengths of the test specimens reasonably well.  相似文献   

17.
This study investigated the effectiveness of carbon fiber-reinforced polymer (CFRP) sheets in protecting reinforced concrete (RC) columns from corrosion of steel reinforcement. Thirty small-scale RC columns and four midscale RC columns were used in this study. The small-scale columns were used for a comprehensive parametric study, whereas the midscale columns were used to evaluate design guidelines proposed based on the results of the small-scale column tests. The test columns were conditioned under an accelerated corrosion process and then tested under uniaxial compression up to failure. The test results showed that although CFRP sheet wrapping decreased the corrosion rate, the corrosion of steel reinforcement could continue to occur, eventually showing a decrease in ultimate axial compression capacity. Design guidelines were proposed based on the small-scale RC column tests and evaluated through a comparison with the test results of midscale RC columns. The proposed design guidelines introduced a concept of effective area to account for the corrosion damage, such as internal cracking and cross-sectional loss of steel reinforcement.  相似文献   

18.
The results of an experimental investigation undertaken to evaluate a new technique for strengthening interior slab–column connection in combined flexural and shear modes are presented. The technique consists of using a combination of shear bolts inserted into holes and prestressed against the concrete surface for improving the punching shear capacity, and external [fiber-reinforced polymer (FRP)] reinforcement bonded to the tension face of the slabs in two perpendicular directions for increasing the flexural strength of the slabs. Square slab specimens of 670×670?mm dimensions were tested and the main test variables included the ratio of steel reinforcement (1.0 and 1.5%), span–depth ratio or thickness (55 and 75?mm) of the slabs, area, and configuration of steel bolts, and area of FRP reinforcement. It was found that the use of shear bolts alone improves the punching shear strength and increases the ductility of failure by changing the failure mode from punching to flexural. However, the use of a combination of shear bolts and a moderate amount of FRP reinforcement increased the flexural strength and resulted in a substantial improvement of the punching shear capacity of the slabs. The corresponding increases attained levels between 34 and 77%. A design approach is presented for evaluating the ultimate capacity of the slab–column connections when strengthened using the proposed strengthening technique. Strength results predicted by the proposed approach were in good agreement with the experimental results.  相似文献   

19.
The feasibility and efficiency of a seismic retrofit intervention using externally bonded fiber-reinforced polymer composites on existing reinforced concrete frame systems, designed prior to the introduction of modern standard seismic design code provisions in the mid-1970s, are herein presented, based on analytical and experimental investigations on beam-column joint subassemblies and frame systems. A multilevel retrofit strategy, following hierarchy of strength considerations, is adopted to achieve the desired performance. The expected sequence of events is visualized through capacity-demand curves within M-N performance domains. An analytical procedure able to predict the enhanced nonlinear behavior of the panel zone region, due to the application of CFRP laminates, in terms of shear strength (principal stresses) versus shear deformation, has been developed and is herein proposed as a fundamental step for the definition of a proper retrofit solution. The experimental results from quasi-static tests on beam-column subassemblies, either interior and exterior, and on three-storey three-bay frame systems in their as-built and CFRP retrofitted configurations, provided very satisfactory confirmation of the viability and reliability of the adopted retrofit solution as well as of the proposed analytical procedure to predict the actual sequence of events.  相似文献   

20.
Concrete-filled fiber reinforced polymer (FRP) tubes (CFFT) have in the last decade been used as girders, beam columns, and piles. The focus of research, however, has been exclusively on their monotonic behavior, with little or no attention to the implications of using CFFT in seismic regions. A total of six CFFT specimens were tested as simple span beam columns under constant axial loading and quasi-static reverse lateral loading in four point flexure. Three of the tubes were made using centrifuge (spin) casting with 12.7?mm thickness with the majority of the fibers in the longitudinal direction, whereas the other three were filament wound with 5?mm thickness and ±55° fiber orientation. One specimen for each type of tube had no internal reinforcement, whereas the other two incorporated approximately 1.7 and 2.5% steel reinforcement ratios, respectively. The two types of tubes represented two different failure modes; a brittle compression failure for the thick tubes with the majority of the fibers in the longitudinal direction, and a ductile tension failure for the thin tubes with off-axis fibers. The study showed that CFFT can be designed with ductility behavior comparable to reinforced concrete members. Significant ductility can stem from the fiber architecture and interlaminar shear in the FRP tube. Moderate amounts of internal steel reinforcement in the range of 1–2% may further improve the cyclic behavior of CFFT.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号