首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Radiation protection dosimetry in radiation fields behind the shielding of high-energy accelerators such as CERN is a challenging task and the quantitative understanding of the detector response used for dosimetry is essential. Measurements with ionisation chambers are a standard method to determine absorbed dose (in the detector material). For applications in mixed radiation fields, ionisation chambers are often also calibrated in terms of ambient dose equivalent at conventional reference radiation fields. The response of a given ionisation chamber to the various particle types of a complex high-energy radiation field in terms of ambient dose equivalent depends of course on the materials used for the construction and the chamber gas used. This paper will present results of computational studies simulating the exposure of high-pressure ionisation chambers filled with different types of gases to the radiation field at CERN's CERN-EU high-energy reference field facility. At this facility complex high-energy radiation fields, similar to those produced by cosmic rays at flight altitudes, are produced. The particle fluence and spectra calculated with FLUKA Monte Carlo simulations have been benchmarked in several measurements. The results can be used to optimise the response of ionisation chambers for the measurement of ambient dose equivalent in high-energy mixed radiation fields.  相似文献   

2.
The monitoring of ambient doses at work places around high-energy accelerators is a challenging task due the complexity of the mixed stray radiation fields encountered. At CERN, mainly Centronics IG5 high-pressure ionisation chambers are used to monitor radiation exposure in mixed fields. The monitors are calibrated in the operational quantity ambient dose equivalent H*(10) using standard, source-generated photon- and neutron fields. However, the relationship between ionisation chamber reading and ambient dose equivalent in a mixed high-energy radiation field can only be assessed if the spectral response to every component and the field composition is known. Therefore, comprehensive studies were performed at the CERN-EU high-energy reference field facility where the spectral fluence for each particle type has been assessed with Monte Carlo simulations. Moreover, studies have been performed in an accessible controlled radiation area in the vicinity of a beam loss point of CERN's proton synchrotron. The comparison of measurements and calculations has shown reasonable agreement for most exposure conditions. The results indicate that conventionally calibrated ionisation chambers can give satisfactory response in terms of ambient dose equivalent in stray radiation fields at high-energy accelerators in many cases. These studies are one step towards establishing a method of 'field calibration' of radiation protection instruments in which Monte Carlo simulations will be used to establish a correct correlation between the response of specific detectors to a given high-energy radiation field.  相似文献   

3.
A moderator-type neutron monitor containing pairs of TLD 600/700 elements (Harshaw) modified with the addition of a lead layer (GSI ball) for the measurement of the ambient dose equivalent from neutrons at medium- and high-energy accelerators, is introduced in this work. Measurements were performed with the Gesellschaft für Schwerionenforschung (GSI) ball as well as with conventional polyethylene (PE) spheres at the high-energy accelerator SPS at European Organization for Nuclear Research [CERN (CERF)] and in Cave A of the heavy-ion synchrotron SIS at GSI. The measured dose values are compared with dose values derived from calculated neutron spectra folded with dose conversion coefficients. The estimated reading of the spheres calculated by means of the response functions and the neutron spectra is also included in the comparison. The analysis of the measurements shows that the PE/Pb sphere gives an improved estimate on the ambient dose equivalent of the neutron radiation transmitted through shielding of medium- and high-energy accelerators.  相似文献   

4.
A good knowledge of the radiation field present outside the shielding of high-energy particle accelerators is very important to be able to select the type of detectors (active and/or passive) to be employed for area monitoring and the type of personal dosemeter required for estimating the doses received by individuals. Around high-energy electron and proton accelerators the radiation field is usually dominated by neutrons and photons, with minor contributions from other charged particles. Under certain circumstances, muon radiation in the forward beam direction may also be present. Neutron dosimetry and spectrometry are of primary importance to characterise the radiation field and thus to correctly evaluate personnel exposure. Starting from the beam parameters important for radiation monitoring, the paper first briefly reviews the stray radiation fields encountered around high-energy accelerators and then addresses the relevant techniques employed for their monitoring. Recent developments to increase the response of neutron measuring devices beyond 10-20 MeV are illustrated. Instruments should be correctly calibrated either in reference monoenergetic radiation fields or in a field similar to the field in which they are used (workplace calibration). The importance of the instrument calibration is discussed and available neutron calibration facilities are briefly reviewed.  相似文献   

5.
Plasma waves excited by intense laser beams can be harnessed to produce femtosecond duration bunches of electrons with relativistic energies. The very large electrostatic forces of plasma density wakes trailing behind an intense laser pulse provide field potentials capable of accelerating charged particles to high energies over very short distances, as high as 1GeV in a few millimetres. The short length scale of plasma waves provides a means of developing very compact high-energy accelerators, which could form the basis of compact next-generation light sources with unique properties. Tuneable X-ray radiation and particle pulses with durations of the order of or less than 5fs should be possible and would be useful for probing matter on unprecedented time and spatial scales. If developed to fruition this revolutionary technology could reduce the size and cost of light sources by three orders of magnitude and, therefore, provide powerful new tools to a large scientific community. We will discuss how a laser-driven plasma wakefield accelerator can be used to produce radiation with unique characteristics over a very large spectral range.  相似文献   

6.
Recombination chambers and different recombination methods have been used for dosimetry of mixed radiation fields at high-energy accelerators for over 40 years. This paper gives a short overview of 11 selected recombination methods used for the determination of H*(10) in mixed radiation fields at high-energy accelerators. A new correction factor is proposed, mainly in order to take into account the dependence of the chamber sensitivity on radiation quality. This factor depends only on the measurable index of radiation quality and can be determined for a particular chamber during the calibration in a reference field of neutron radiation. A comparison of the results obtained at high-energy accelerators showed that all the methods gave the same values of H(10), within a specified accuracy of about 20%, so all of them are suitable for monitoring complex mixed radiation fields at workplaces.  相似文献   

7.
Radiation protection around CERN's high-energy accelerators represents a major challenge due to the presence of complex, mixed radiation fields. Behind thick shielding neutrons dominate and their energy ranges from fractions of eV to about 1 GeV. In this work the response of various portable detectors sensitive to neutrons was studied at CERN's High-Energy Reference Field Facility (CERF). The measurements were carried out with conventional rem counters, which usually cover neutron energies up to 20 MeV, the Thermo WENDI-2, which is specified to measure neutrons up to several GeV, and a tissue-equivalent proportional counter. The experimentally determined neutron dose equivalent results were compared with Monte Carlo (MC) simulations. Based on these studies field calibration factors can be determined, which result in a more reliable estimate of H(*)(10) in an unknown, but presumably similar high-energy field around an accelerator than a calibration factor determined in a radiation field of a reference neutron source.  相似文献   

8.
High-density, fast digital devices, like field programmable gate arrays (FPGAs), microcontrollers, and static random access memories (SRAMs), can be produced by nanotechnology. New technologies allow the design of fast and powerful devices; however, the decreasing dimensions create new problems. Even at ground level, cosmic ray particles arriving from outer space can affect digital devices and provoke single-event effects (SEEs) due to the smaller sensitive volume (SV). In general, for decreasing feature size of memory cells the expected critical charge decreases and the expected sensitivity to radiation increases.

High-density SRAM chips were used to design a fast response, highly sensitive neutron detector. We have conducted experiments with SRAMs at the DESY Research Centre in Hamburg, Germany. Memory contents (number of SEU) were recorded as a function of neutron expose time. The chips were exposed to a neutron field from an americium-beryllium neutron source (241AmBe). The second experiment was accomplished in the 450?MeV electron Linac (Linac II) tunnel. Another batch of SRAMs was irradiated with 60Co gamma rays to a dose of about 60?Gy, and no SEU was registered. This shows that gamma radiation has no substantial effect on the production of SEU in the SRAM. The proposed detector could be ideal for the detection of pulsed neutron radiation produced by high-energy electron linear accelerators and synchrotron facilities, which are currently in operation and planned for the near future.  相似文献   

9.
Monitoring of ionising radiation around high-energy particle accelerators is a difficult task due to the complexity of the radiation field, which is made up of neutrons, charged hadrons, muons, photons and electrons, with energy spectra extending over a wide energy range. The dose-equivalent outside a thick shield is mainly owing to neutrons, with some contribution from photons and, to a minor extent, the other particles. Neutron dosimetry and spectrometry are thus of primary importance to correctly evaluate the exposure of personnel. This paper reviews the relevant techniques and instrumentation employed for monitoring radiation fields around high-energy proton accelerators, with particular emphasis on the recent development to increase the response of neutron measuring devices > 20 MeV. Rem-counters, pressurised ionisation chambers, superheated emulsions, tissue-equivalent proportional counters and Bonner sphere spectrometers are discussed.  相似文献   

10.
HiDOSE (Heavy ion DOSimetry Experiment) and nDOSE (neutron DOSimetry Experiment) experiments conducted as a part of BIOKIS (Biokon in Space) payload were designed to measure the dose equivalent due to charged particles and to neutron field, on the entire energy range, during STS-134 mission. Given the complexity of the radiation field in space environment, dose measurements should be considered an asset of any space mission, and for this reason HiDOSE and nDOSE experiments represent an important contribution to the radiation environment assessment during this mission, a short duration flight. The results of these experiments, obtained using Thermo Luminescence Dosimeters (TLDs) to evaluate the charged particles dosimetry and neutron bubbles dosimeters and stack bismuth track dosimeters for neutron dosimetry, indicate that the dose equivalent rate due to space radiation exposure during the STS-134 mission is in accordance with the results obtained from long duration flights.  相似文献   

11.
High-energy linear accelerators (linacs) have several advantages, including low skin doses and high dose rates at deep-seated tumours. But, at energies more than 8 MeV, photonuclear reactions produce neutron contamination around the therapeutic beam, which may induce secondary malignancies. In spite of improvements achieved in medical linac designs, many countries still use conventional (non-intensity-modulated radiotherapy) linacs. Hence, in these conventional machines, fitting the beam over the treatment volume may require using blocks. Therefore, the effect of these devices on neutron production of linacs needs to be studied. The aim of this study was to investigate the effect of field shaping blocks on photoneutron dose in the treatment plane for two high-energy medical linacs. Two medical linacs, a Saturn 43 (25 MeV) and an Elekta SL 75/25 (18 MeV), were studied. Polycarbonate (PC) films were used to measure the fluence of photoneutrons produced by these linacs. After electrochemical etching of the PC films, the neutron dose equivalent was calculated at the isocentre and 50 cm away from the isocentre. It was noted that by increasing the distance from the centre of the X-ray beam towards the periphery, the photoneutron dose equivalent decreases rapidly for both the open and blocked fields. Increasing the energy of the photons causes an increase in the amount of photoneutron dose equivalent. At 25 MeV photon energy, the lead blocks cause a meaningful increase in the dose equivalent of photoneutrons. In this research, a 30% increase was seen in neutron dose contribution to central axis dose at the isocentre of a 25 MeV irregular field shaped by lead blocks. It is concluded that lead blocks must be considered as a source of photoneutron production when treating irregular fields with high-energy photons.  相似文献   

12.
At high-energy particle accelerators, area monitoring needs to be performed in a wide range of neutron energies. In principle, neutrons occur from thermal energies up to the energy of the accelerated ions, which is for the present GSI (Gesellschaft für Schwerionenforschung) accelerator facility approximately 1-2 GeV per nucleon. There are no passive dosemeters available, which are designed for the use at high-energy accelerators. At GSI, a neutron dosemeter was developed, which is suitable for the measurement of high-energy neutron radiation by the insertion of a lead layer around Thermoluminescence (TL) detection elements (pairs of TL 600/700) at the centre of the dosemeter. The design of the sphere was derived from the construction of the extended range rem-counters for the measurement of ambient dose equivalent H(10). In this work, the dosemeter fluence response was measured in the quasi-monoenergetic neutron fields of the accelerator facility of the PTB in Braunschweig and in the thermal neutron field of the GKSS research reactor FRG-1 in Geesthacht. For the accelerator measurements, the reactions (7)Li(p,n)(7)Be, (3)H(p,n)(3)He and (2)H(d,n)(3)He were used to produce neutron fields with energy peaks between 144 keV and 19 MeV. The measured fluence responses are 27% too low for thermal energies and show an agreement with approximately 14% for the accelerator produced neutron fields related to the computed fluence responses (MCNP, FLUKA calculations). The measured as well as the computed fluence responses of the dosemeter are compared with the corresponding conversion coefficients.  相似文献   

13.
High-energy accelerators can produce strong time-structured radiation fields. Such dose shots are generated at linear machines with low duty cycles as well as at circular machines when complete fills are instantaneously lost. The main dose component behind thick shielding is due to high-energy neutrons occurring at that time structure. Dosemeters based on Geiger-Mueller tubes or proportional counters fail here completely. The 12B counter, a novel dosemeter made of a plastic scintillator using carbon activation for event-like exposure, has been introduced. High-energy neutrons activate the carbon nuclei by three inelastic reactions. The decay patterns with half-lives between 20 ms and 20 min can be exploited depending on the time structure of the radiation field. The response of the 12B counter was measured along with some other dosemeters, both active and passive, in the radiation field behind the lateral concrete shielding of a 7.5 GeV proton transfer line.  相似文献   

14.
Radiation sources producing short pulses of photon radiationare widespread. Such sources include electron linear acceleratorsand field emission impulse generators. It is often desirableto measure leakage and skyshine radiation for these sourcesin real time and at environmental levels as low as 0.02 µSvper pulse. This note provides an overview of the design andperformance of a commercial, real-time, pulsed photon dosemeter(PPD) capable of single-pulse dose measurements over the rangefrom 0.02 to 20 µSv. The PPD may also be operated in amultiple-pulse mode that integrates the dose from a train ofpulses over a 3 s period. A pulse repetition rate of up to 300Hz is accommodated.  相似文献   

15.
In this work, simplified recombination methods for routine estimation of dose equivalent in mixed (gamma and neutrons) radiation field outside the irradiation field of linear medical accelerators is considered. The author's earlier reported method of H(10) measurements, involving determination of the recombination index of radiation quality, Q(4) by tissue-equivalent recombination chamber was combined with the new method for determination of the photon to neutron dose ratio D(X)/D(n) from the ratio of ion collection efficiencies measured in the investigated radiation field and in two reference fields of gamma and neutron radiations. The method is suitable when the neutron contribution to the total absorbed dose, D(n)/D, is >3%.  相似文献   

16.
Laser-driven accelerators will be realized as the next generation particle accelerators in the near future. Their development has been accelerated by success of high-energy gain electron acceleration by means of a laser wakefield excited via interaction of intense ultrashort laser pulses with underdense plasmas. On the basis of achievements of laser wakefield acceleration (LWFA) experiments, a design of LWFA for the second-generation study is considered from the point of view of application to high-energy accelerators, such as future linear colliders.  相似文献   

17.
While inhalation dose coefficients are provided for about 800 radionuclides in International Commission on Radiological Protection (ICRP) Publication 68, many radionuclides of practical dosimetric interest for facilities such as high-energy proton accelerators are not specifically addressed, nor are organ-specific dose coefficients tabulated. The ICRP Publication 68 dosimetry concepts are used, along with updated radiological decay data and metabolic data, to calculate committed equivalent dose coefficients [h(T)(50)] and committed effective dose coefficients [e(50)] for radionuclides produced at the Oak Ridge National Laboratory's Spallation Neutron Source.  相似文献   

18.
Particle accelerators and their surroundings are locations of residual radioactivity production that is induced by the interaction of high-energy particles with matter. This paper gives an overview of the principles of activation caused at proton accelerators, which are the main machines operated at Conseil Européen pour la Recherche Nucléaire. It describes the parameters defining radio-nuclide production caused by beam losses. The second part of the paper concentrates on the analytic calculation of activation and the Monte Carlo approach as it is implemented in the FLUKA code. Techniques used to obtain, on the one hand, estimates of radioactivity in Becquerel and, on the other hand, residual dose rates caused by the activated material are discussed. The last part of the paper focuses on experiments that allow for benchmarking FLUKA activation calculations and on simulations used to predict activation in and around high-energy proton machines. In that respect, the paper addresses the residual dose rate that will be induced by proton-proton collisions at an energy of two times 7 TeV in and around the Compact Muon Solenoid (CMS) detector. Besides activation of solid materials, the air activation expected in the CMS cavern caused by this beam operation is also discussed.  相似文献   

19.
One of the many risks of long-duration space flights is the excessive exposure to cosmic radiation, which has great importance particularly during solar flares and higher sun activity. Monitoring of the cosmic radiation on board space vehicles is carried out on the basis of wide international co-operation. Since space radiation consists mainly of charged heavy particles (protons, alpha and heavier particles), the equivalent dose differs significantly from the absorbed dose. A radiation weighting factor (w(R)) is used to convert absorbed dose (Gy) to equivalent dose (Sv). w(R) is a function of the linear energy transfer of the radiation. Recently used equipment is suitable for measuring certain radiation field parameters changing in space and over time, so a combination of different measurements and calculations is required to characterise the radiation field in terms of dose equivalent. The objectives of this project are to develop and manufacture a three-axis silicon detector telescope, called Tritel, and to develop software for data evaluation of the measured energy deposition spectra. The device will be able to determine absorbed dose and dose equivalent of the space radiation.  相似文献   

20.
The neutron contribution to the spacecraft crew exposure could represent an important part of the total dose equivalent value. The determination of this contribution represents a rather complex and difficult task, both through experimental and theoretical estimation. This paper will present an attempt to determine the neutron contribution onboard the International Space Station and Foton capsule using the data measured by means of a Si-diode based energy deposition spectrometer. As such a spectrometer, the MDU-Liulin equipment, developed in one of our laboratories was used. The equipment allows the data accumulated during the passage in or out of the South Atlantic Anomaly (SAA). In this paper, only the data obtained out of the SAA were analysed, assuming that the neutron spectra are similar to those onboard aircraft and/or at the CERF high-energy radiation field. The excess of deposited energy in the region above 1 MeV, when comparing with the aircraft field, was expected to represent the primary high-energy charged particles. Total dosimetry characteristics obtained in this way are in reasonable agreement with other data, neutron contribution representing approximately 40% of the total dose equivalent for the flight duration outside of the SAA.  相似文献   