首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到12条相似文献,搜索用时 0 毫秒
1.
2.
3.
The revision task on technical specification for application of autoclaved aerated concrete products JGJ/T17 is under way, which was assigned in November 2013.The framework, thoughts and contents of revision on the specification are presented in this paper.  相似文献   

4.
5.
Load‐bearing capacity tables for unreinforced masonry according to DIN EN 1996‐3/NA:2019‐12 Practical design aids are important tools in the day‐to‐day business of structural design. The design of primarily vertically loaded masonry walls in usual building construction can be carried out with the help of so‐called load‐bearing capacity tables. A table value is read off exclusively as a function of the geometric conditions, which – multiplied by the masonry compressive strength – results in the load‐bearing capacity of the wall for cold design and in case of fire. By comparing the acting and resisting force, the verification of structural design can be provided in a simple and yet economical form. The bearing capacity tables based on the simplified calculation methods according to DIN EN 1996‐3/NA:2019‐12 [1], [2] and DIN EN 1996‐1‐2/NA:2013‐06 [3], [4] are presented in this paper. Compared to the previous edition of Part 3 of Eurocode 6, the extended scope of application is taken into account, as well as the normative changes to the construction method with partially supported slabs.  相似文献   

6.
7.
《Mauerwerk》2017,21(5):306-319
Dedicated to University Prof. Dr.‐Ing. Carl‐Alexander Graubner for his 60th birthday The simplified calculation methods for unreinforced masonry structures given in DIN EN 1996‐3/NA are an easily applicable design standard for an efficient and fast verification of the resistance of mainly vertically loaded masonry walls. However, the design rules are not based on mechanical models. Instead, they are empirical approaches for a simplified estimation of the load bearing capacity. For this reason, the range of application of DIN EN 1996‐3/NA is limited by several conditions to ensure a sufficient safety of this design procedure. With regard to extending the conditions for application, extensive comparative calculations were carried out. Thereby, considering clearly defined boundary conditions, the load bearing capacity according to DIN EN 1996‐3/NA was compared to that according to DIN EN 1996‐1‐1/NA. It was the aim of this comparison to identify load bearing reserves of the simplified calculation methods to point out potential for an extension regarding the maximum permissible clear wall height and the slab span. As a result, it can be stated, that an increase of the maximum wall height up to 6.0 m and the maximum slab span of 7.0 m is possible in certain cases.  相似文献   

8.
The semi‐probabilistic safety concept of divided safety factors for action and resistance of DIN EN 1990 [1] in combination with the structural design codes DIN EN 1996‐1‐1 [2] and DIN EN 1996‐1‐1/NA [3] include the requirement that acting normal forces NEd may not exceed the normal force resistances NRd for the structural design of masonry under bending compression. According to [3], fully plastic material behaviour can be assumed and the stress block used as the material law for masonry. Building on this, design aids and their theoretical basis were presented in Part 1 of this scientific paper [4], which are comparable with the ω tables (called the ? table here) and the general design diagram for massive construction. The application of the design aids is described in this second part of this scientific paper through calculation examples and the connection with the calculation approaches of [3] is made clear. The relation to the reduction factor ?m, which covers effects of 2nd order theory, is also obtained. With known values of the load eccentricities according to 1st and 2nd order theory, the design task becomes the analysis of the loadbearing capacity of the masonry section at half wall height. Knowing ?m, the load eccentricity e2 and the additional moment according to 2nd order theory can subsequently be determined, which does not ensue from the calculation equations of [3]. With the general design diagram, the values of compression zone height and the assumed load eccentricities of the acting normal forces, which result from the reset rule for masonry sections with high load eccentricities, can be directly read off, greatly improving the clarity of this procedure.  相似文献   

9.
According to Eurocode 6, unreinforced masonry walls can be designed using different verification methods, whereby the simplified calculation methods are contained in Part 3 of DIN EN 1996 [1]. If the associated application limits and boundary conditions are fulfilled, a large part of the usual problems occurring in masonry construction can be dealt with without great effort. A limiting condition for the application of the simplified calculation methods is a maximum clear wall height of h = 2.75 m or h = 12 ? t. Changes in user requirements for modern buildings with masonry walls nowadays often require greater wall heights, wherefore a verification according to the general rules from DIN EN 1996‐1‐1/NA [2] is necessary. This means a considerably higher effort for the structural engineer. A considerable amount of calculations was done to verify whether the results of the simplified calculation methods are also valid for greater wall heights. The results were transferred into a consistent standardization proposal with regard to extended application limits of DIN EN 1996‐3/NA, which is contained in a new draft Amendment A3 for the National Application Document for Germany.  相似文献   

10.
11.
12.
This article is written against the backdrop of the work of the European standardisation committees on the amendment of EN 1996‐1‐1 [N 4] which will also exert an influence on the design of reinforced masonry in Germany. This paper focusses on the design approaches of DIN EN 1996‐1‐1 for untensioned reinforced masonry beams under shear load in the ultimate limit state (ULS). Proposals are made to discuss their revision. The contents of E DIN 1053‐3 [N 3] and of the final draft of the guideline ”Flat Lintels” [7] are taken into account.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号