首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
PM2.5 chemical composition in Hong Kong: urban and regional variations   总被引:1,自引:0,他引:1  
Chemically speciated PM2.5 measurements were made at roadside, urban, and rural background sites in Hong Kong for 1 year during 2000/2001 to determine the spatial and temporal variations of PM2.5 mass and chemical composition in this highly populated region. Annual average PM2.5 concentrations at the urban and rural sites were 34.1 and 23.7 microg m(-3), respectively, approximately 50-100% higher than the United States' annual average National Ambient Air Quality Standard (NAAQS) of 15 microg m(-3). Daily PM2.5 concentrations exceeded the U.S. 24-h NAAQS of 65 microg m(-3) on 19 days, reaching 131+/-8 microg m(-3) at the roadside site on 02/28/2001. Carbonaceous aerosol is the largest contributor to PM2.5 mass (explaining 52-75% of PM2.5 mass at the two urban sites and 32% at the background site), followed by ammonium sulfate (ranging from 23% to 37% at the two urban sites and 51% at the background site). Ammonium sulfate and crustal concentrations showed more uniform spatial distributions, while the largest urban-rural contrasts found in carbonaceous aerosol (likely due to emissions from on-road gasoline and diesel vehicles). Marine influences accounted for 7% of the mass at the background site (more than twice as much as at the two urban sites). Ternary diagrams are utilized to illustrate the different spatial patterns.  相似文献   

2.
The carbon composition of fine particles (PM(2.5)) from traffic exhausts may play a role in adverse health effects. The objective of this study was to assess the concentrations of elemental and organic carbon in PM(2.5) in traffic exhausts from different types of vehicles in the booths of Taiwanese toll station workers and estimate the relations between traffic density and carbon concentrations. Tollbooth indoor monitoring samples were collected for 10 days to assess the 8 h integrated PM(2.5) concentration. Particle samples were analyzed for the content of total carbon, and elemental, and organic carbon. The mean carbon concentrations in the bus and truck lanes were [total: 167.7 microg/m(3) (SD 79.8 microg/m(3)); elemental: 131.7 (66.2); organic: 36.0 (25.8)], substantially higher compared with the car lanes with cash payment [39.2 (29.5); 20.2 (19.5); 19.2 (14.6)] and the car lanes with ticket payment [34.1 (26.1); 15.8 (17.6); 18.5 (12.2)]. The increase in elemental carbon concentration per vehicle in the bus and truck lane was 14 and 9 times greater than that of car lanes of ticket payment and car lanes of cash payment. The mass fraction of carbonaceous species in PM(2.5) accounted for 54% in bus and truck lanes, whereas the corresponding figure was 30-31% for car lanes. Elemental carbon is an important component of diesel exhaust. Workers in toll stations are exposed to high levels of both elemental and organic carbon.  相似文献   

3.
In this study a set of 340 PM10 and PM2.5 samples collected throughout 16 months at rural, an urban kerbside and an industrial background site (affected by the emissions from the ceramic manufacture and other activities) were interpreted. On the regional scale, the main PM10 sources were mineral dust (mainly Al2O3, Fe, Ti, Sr, CaCO3, Mg, Mn and K), emissions derived from power generation (SO4=, V, Zn and Ni), vehicle exhausts (organic and elemental carbon, NO3- and trace elements) and marine aerosol (Na, Cl and Mg). The latter was not identified in PM2.5. At the industrial site, additional PM10 sources were identified (tile covering in the ceramic production, petrochemical emissions and bio-mass burning from a large orange tree cultivation area). The contribution of each PM source to PM10 and PM2.5 levels experiences significant variations depending on the type of PM episode (Local-urban mainly in autumn-winter, regional mainly in summer, African or Atlantic episode), which are discussed in this study. The results show that it would be very difficult to meet the EU limit values for PM10 established for 2010. The annual mean PM levels are 22.0 microg PM10/m3 at the rural and 49.5 microg PM10/m3 and 33.9 microg PM2.5/m3 at the urban site. The natural contribution in this region, estimated at 6 microg/m3 of natural mineral dust (resulting from the African events and natural resuspension) and 2 microg/m3 of marine aerosol, accounts for 40% of the 2010 EU annual limit value (20 microg PM10/m3). Mineral dust concentrations at the urban and industrial sites are higher than those at the rural site because of the urban road dust and the ceramic-production contributions, respectively. At the urban site, the vehicle exhaust contribution (17 microg/m3) alone is very close to the 2010 EU PM10 limit value. At the rural site, the African dust is the main contributor to PM10 levels during the highest daily mean PM10 events (100th-97th percentile range). At the urban site, the vehicle exhaust product is the main contributor to PM10 and PM2.5 levels during the highest daily mean PM events (100th-85th percentile range). Mineral dust concentrations during African dust events accounts for 20-30 microg/m3 in PM10 and 10-15 microg/m3 in PM2.5. During non-African dust events, mineral dust derived from anthropogenic activities (e.g. urban road dust) is also a significant contributor to PM10, but not to PM2.5.  相似文献   

4.
Cao JJ  Lee SC  Chow JC  Cheng Y  Ho KF  Fung K  Liu SX  Watson JG 《Indoor air》2005,15(3):197-204
Six residences were selected (two roadside, two urban, and two rural) to evaluate the indoor-outdoor characteristics of PM(2.5) (aerodynamic diameter <2.5 microm) carbonaceous species in Hong Kong during March and April 2004. Twenty-minute-averaged indoor and outdoor PM(2.5) concentrations were recorded by DustTrak samplers simultaneously at each site for 3 days to examine diurnal variability of PM(2.5) mass concentrations and their indoor-to-outdoor (I/O) ratios. Daily (24-h average) indoor/outdoor PM(2.5) samples were collected on pre-fired quartz-fiber filters with battery-powered portable mini-volume samplers and analyzed for organic and elemental carbon (OC, EC) by thermal/optical reflectance (TOR) following the Interagency Monitoring of Protected Visual Environments (IMPROVE) protocol. The average indoor and outdoor concentrations of 24 h PM(2.5) were 56.7 and 43.8 microg/m(3), respectively. The short-term PM(2.5) profiles indicated that the penetration of outdoor particles was an important contributor to indoor PM(2.5), and a household survey indicated that daily activities were also sources of episodic peaks in indoor PM(2.5). The average indoor OC and EC concentrations of 17.1 and 2.8 microg/m(3), respectively, accounted for an average of 29.5 and 5.2%, respectively, of indoor PM(2.5) mass. The average indoor OC/EC ratios were 5.8, 9.1, and 5.0 in roadside, urban, and rural areas, respectively; while average outdoor OC/EC ratios were 4.0, 4.3, and 4.0, respectively. The average I/O ratios of 24 h PM(2.5), OC, and EC were 1.4, 1.8, and 1.2, respectively. High indoor-outdoor correlations (r(2)) were found for PM(2.5) EC (0.96) and mass (0.81), and low correlations were found for OC (0.55), indicative of different organic carbon sources indoors. A simple model implied that about two-thirds of carbonaceous particles in indoor air are originated from outdoor sources. PRACTICAL IMPLICATIONS: Indoor particulate pollution has received more attentions in Asia. This study presents a case study regarding the fine particulate matter and its carbonaceous compositions at six residential homes in Hong Kong. The characteristics and relationship of atmospheric organic and elemental carbon were discussed indoors and outdoors. The distribution of eight carbon fractions was first reported in indoor samples to interpret potential sources of indoor carbonaceous particles. The data set can provide significant scientific basis for indoor air quality and epidemiology study in Hong Kong and China.  相似文献   

5.
Sub-Saharan Africa has the highest rate of urban population growth in the world, with a large number of urban residents living in low-income "slum" neighborhoods. We conducted a study for an initial assessment of the levels and spatial and/or temporal patterns of multiple pollutants in the ambient air in two low-income neighborhoods in Accra, Ghana. Over a 3-week period we measured (i) 24-hour integrated PM(10) and PM(2.5) mass at four roof-top fixed sites, also used for particle speciation; (ii) continuous PM(10) and PM(2.5) at one fixed site; and (iii) 96-hour integrated concentration of sulfur dioxide (SO(2)) and nitrogen dioxide (NO(2)) at 30 fixed sites. We also conducted seven consecutive days of mobile monitoring of PM(10) and PM(2.5) mass and submicron particle count. PM(10) ranged from 57.9 to 93.6 microg/m(3) at the four sites, with a weighted average of 71.8 microg/m(3) and PM(2.5) from 22.3 to 40.2 microg/m(3), with an average of 27.4 microg/m(3). PM(2.5)/PM(10) ratio at the four fixed sites ranged from 0.33 to 0.43. Elemental carbon (EC) was 10-11% of PM(2.5) mass at all four measurement sites; organic matter (OM) formed slightly less than 50% of PM(2.5) mass. Cl, K, and S had the largest elemental contributions to PM(2.5) mass, and Cl, Si, Ca, Fe, and Al to coarse particles. SO(2) and NO(2) concentrations were almost universally lower than the US-EPA National Ambient Air Quality Standards (NAAQS), with virtually no variation across sites. There is evidence for the contributions from biomass and traffic sources, and from geological and marine non-combustion sources to particle pollution. The implications of the results for future urban air pollution monitoring and measurement in developing countries are discussed.  相似文献   

6.
The chemical characteristics of ambient particulate matters in urban and rural areas of Hong Kong were determined in this study. A monitoring program starting from November 2000 to February 2001 (winter) and June 2001 to August 2001 (summer) for PM10 and PM2.5 was performed at three monitoring stations in Hong Kong. Twenty-four-hour PM10 and PM2.5 samples were collected once every 6 days at two urban sites, PolyU and KT, and every 12 days at a background site, HT, with Hi-Vol samplers. High concentrations of OC, EC (except in PolyU), water-soluble ions and elements were observed in winter among the three sampling sites for PM10 and PM2.5 fractions. Seasonal variations were significant in background HT. Dilution effect due to the increase in mixing depth and precipitation in summer reduced the concentrations of particulate matters. Long-range transport could contribute to the higher concentrations of particulate matter in the winter. Chemical mass closure calculations were performed for PM10 and PM2.5 observed. Mass closure improved when separate factors (1.4 and 1.9 respectively) were used to convert water-soluble organic carbon (WSOC) and water-insoluble organic carbon (WINSOC) into corresponding organic masses. The urban sites showed high percentages of water-soluble ions in winter and high percentages of carbonaceous species in summer. Better results were obtained for the chemical mass closure analysis in winter than in summer. High temperature and solar radiation in summer increased the rate of the complex photochemical reaction in the atmosphere. Therefore the chemical mass closure analysis would underestimate the volatized species and secondary aerosols during summer.  相似文献   

7.
In this study, the hourly variations of the mass concentrations of PM10, SO2, NO(x) and O3 at three sampling sites were observed in Beijing during dust storm occurrence period in April 2000. The PM2.5 samples were simultaneously collected. By comparing the hourly variations of the pollutant concentrations before, during and after dust storm event and haze pollution episode, the variation characteristics of the mass concentrations of PM10, SO2, NO(x) and O3 during dust storm events were presented. The results show that the mass concentration of PM10 reached 1500 microg m(-3) during dust storm events on April 6 and 25, 2000, which was 5-10 times that of the non-dust weather conditions, and this period of high mass concentration of PM10 lasted for about 14 h, and then the concentration level prior to the dust event was recovered in 6-h time period. Due to the strong wind, the concentrations of SO2, NO(x), NO2 and O3 during dust storm period were maintained at low levels, which was significantly different from those on non-dust storm and haze pollution conditions. A lot of coarse particles as well as a very large amount of fine particles were contained in the atmospheric particulates during dust storm period, and the concentration level of PM2.5 was comparable to that during haze pollution episode. During the dust storm period, the PM2.5 concentration was approximately 230 microg m(-3), accounting for 30% of the total PM10 mass concentration, was four times that of non-dust weather conditions, and the crustal elements constituted about 66.4% of the chemical composition of PM2.5 while sulfate and nitrate contributed much less, which was quite different from the chemical composition of PM2.5 primarily constituted by sulfate, nitrate and organics on haze pollution day.  相似文献   

8.
An analysis of atmospheric gases and particles during periods of land and sea breezes in a coastal city in southwest Mexico indicates limited removal of total particle mass by deposition during periods when the air resides over the ocean. The average PM(2.5) mass concentrations for land and sea breeze samples were 25+/-1.0 and 26+/-1.0 microg m(-3), respectively. The average sum of the ion concentrations (NH(4)(+), SO(4)(2-), NO(3)(-), Na(+), Cl(-)) were 10 and 11.8 microg m(-3) for the samples taken during land and sea breeze periods. The average total carbon concentrations were 6.0 and 5.3 microg m(-3) for land and sea breeze periods. The mass of sulfate in particles of ocean origin, 3.3+/-2.8 microg m(-3), is marginally higher than those originating from the land, 2.0+/-0.8 microg m(-3), presumably as a result of the conversion of SO(2) recirculated from the city. The fraction of sulfate, nitrate and ammonium ions in rainwater samples is almost a factor of two higher than the fraction measured on filtered air samples. The rainwater also contains significant concentrations of elemental and organic carbon. This study, although extending over a period of only 15 days, with limited chemical samples, suggests that recirculation of anthropogenic particles from coastal cities should be taken into consideration when diagnosing and predicting air quality in such regions.  相似文献   

9.
This study compared commuters' exposures to particulate matter (PM) while using motorcycles, cars, buses, and the mass rapid transit (MRT) on the same routes in Taipei, Taiwan. Motorcycle commuters who had the shortest travel time (28.4+/-4.2 min) were exposed to the highest concentrations of PM(10) (112.8+/-38.3 microg/m(3)), PM(2.5) (67.5+/-31.3 microg/m(3)), and PM(1.0) (48.4+/-24.7 microg/m(3)) among four commuting modes. By contrast, car commuters were exposed to the lowest PM concentrations and had the second shortest travel time among them. Motorcycle commuters' high trip-averaged PM concentrations and bus commuters' long commuting time (43.1+/-5.1 min) resulted in their high whole-trip PM exposures. Size fractions of PM were relatively consistent across PM exposures of the four commuting modes with fine particles (PM(2.5)) contributing to 53-60% of PM(10) and submicron particle (PM(1)) contributing to 39-43% of PM(10). Motorcycles idled at traffic lights and bus doors opened at stops increased commuters' PM exposures. Fixed-site monitoring data explained well the variation of whole-trip PM(10) exposure of car (r(2)=0.63) and MRT (r(2)=0.52) commuters, and of whole-trip PM(2.5) exposure of car (r(2)=0.76), MRT (r(2)=0.73) and motorcycle (r(2)=0.64) commuters in regression analyses. The coefficients (slopes) of regression between fixed-site monitoring data and PM(2.5) exposures were less than 1 for car and MRT commuters but greater than 1 for motorcycle commuters. In conclusion, proximity to traffic emissions contributes to a person's high PM exposure during his or her daily commute. This proximity occurs when people use motorcycles on roads and when bus/MRT commuters walk or wait along commuting routes. Fixed-site air monitoring data can under-estimate motorcycle commuters' PM(2.5) exposures but over-estimate car and MRT commuters' PM(2.5) exposures.  相似文献   

10.
Twenty-three hour measurements of PM(2.5) particulate matter have been carried out during the period between the 1st April and the 13th November 2003 in a suburban area of Athens. The monitoring site was located in the National Research Center "DEMOKRITOS", on the foot of Hemittos Mountain and about 12 km away from the center of Athens. The site covers an area of 600 acres in a forest of pine trees close enough to the newly constructed Hemittos Mountain peripheral highway. PM(2.5) samples were collected on 47 mm filters, with the use of low volume gravimetric samplers while a meteorological station recorded meteorological data 6 m above the ground, nearby the sampling instrumentation. The daily average PM(2.5) concentration reached 21.1 microg m(-3) and all measurements were below U.S. Environmental Pollution Agency daily limit (65 microg m(-3)). A regression analysis was used to investigate the relationship among PM(2.5) concentrations and meteorological parameters. Additionally, PM(2.5) mass concentrations were correlated with other inorganic gaseous pollutants (O(3), NO, NO(2), SO(2)) while weekly and seasonal PM(2.5) variations were also investigated.  相似文献   

11.
Aerosol samples for PM2.5 (particulate matter with aerodynamic diameters less than 2.5 microns), PM2.5-10 (particulate matter with aerodynamic diameters between 2.5 and 10 microns) and TSP were collected from June to September 1998 at THU (suburban) and HKIT (rural) sites in central Taiwan. The ratios of PM2.5/PM10 averaged 0.70 for the daytime and 0.63 for the nighttime at THU, respectively. At HKIT, the PM2.5/PM10 ratios averaged 0.56 for the daytime and 0.72 in the nighttime, respectively. These results indicated that the PM2.5 concentrations contribute the majority of the PM10 concentration and PM10 concentrations contribute the majority of the TSP at both sites. The averaged PM2.5 concentrations at THU are higher than those measured at HKIT during the daytime period. However, the average PM2.5-10 concentrations in THU are lower than those measured at HKIT during nighttime. The samples collected were also analyzed by atomic absorption spectrophotometry for the elemental analysis of Ca, Fe, Pb, Zn, Cu, Mn and Cr. Meanwhile ion chromatography was used to analyze for the water-soluble ions: sulphate, nitrate and chloride in the Universal samples. The concentrations of heavy metals in PM10 during daytime were all higher than nighttime at THU. However, the averaged concentrations of metal elements in PM10 during day and night period were distributed irregularly at HKIT. The results indicated that for metal elements collected at HKIT have different emission sources. The concentrations of metal elements during daytime in PM10 at THU were generally higher than HKIT. The phenomena owing to the averaged PM2.5 particle concentrations at THU (suburban) were higher than those measured at HKIT (rural) and PM2.5 occupied the major portions of PM10 for both sites during the day period. For anion species, there are no significant differences between day and night period in PM10 concentrations at both suburban and rural sites.  相似文献   

12.
This study conducted an atmospheric aerosol sampling to measure the PM10 (particles < 10 microns in aerodynamic diameter) and PM2.5 (particles < 2.5 microns in aerodynamic diameter) mass concentrations from October 1996 to June 1997 in northern (Taipei), central (Taichung) and southern (Kaohsiung), the three largest cities of Taiwan. Seventy-eight samples were obtained to measure the mass concentrations of PM10 and PM2.5 from nine sampling sites. According to those results, the PM10 mass concentrations in Taipei, Taichung and Kaohsiung were 42.19, 60.99 and 77.10 micrograms/m3, respectively. The corresponding PM2.5 mass concentrations were 23.09, 39.97 and 48.47 micrograms/m3, respectively. The PM2.5 fraction accounted for 61-67% of the PM10 mass in central and southern Taiwan, but was lower (54-59%) in northern Taiwan. Some samples in which the PM2.5 fraction was overwhelmingly dominant could reach as high as 80-95% of the PM10 mass. In addition, the PM2.5, PM10 levels and PM2.5/PM10-2.5 (particles with aerodynamic diameters ranging from 2.5 to 10 microns) ratios in metropolitan Taiwan significantly fluctuated from site-to-site and over time. Moreover, ambient daily PM2.5 and PM10-2.5 mass concentrations did not correlate well with each other at most of the sampling sites, indicated that they originated from different kinds of sources and emitted variedly over time.  相似文献   

13.
Results obtained during a winter field campaign for the fine fractions of particulate matter are presented. A high pollution episode together with an analysis of the main factors, which influence accumulation of pollutants is described. The measurement campaigns were carried out simultaneously at two sites in Northern Italy, Milan and Erba, during the winter of 2000. The daily variability in the mass concentration values and PM2.5/PM10 ratios appeared to be strongly dependent upon meteorological and atmospheric stability conditions and, in particular, wind regimes. During the intensive field campaign a high-pollution episode occurred that led to TSP and fine fraction concentrations well above the attention and alarm thresholds, reaching values of up to 200-250 microg m(-3). The elemental concentrations were determined by ED-XRF analysis. The elemental composition of the particulate matter indicated that crustal matter oxides (soil dust) were the main component in particles with aerodynamic diameter d(ae) > 10 microm. They were an important part also in particles with 2.5 < d(ae) < 10 microm, but strongly decreased in particles with d(ae) < 2.5 microm. In the finer fraction sulphates nitrogen and carbon compounds played a major role. The temporal patterns of mass and elemental concentrations, as well as the main components of PM were very similar at the two sites. The high-pollution episode was recorded at many locations in the Po plain, highlighting the role of meteorology and thermodynamic atmospheric conditions on pollution build-up on a large area.  相似文献   

14.
A new method using several different chemical scenarios is developed to predict chemical composition of fine (PM2.5) and total (PM10) aerosol. This method improves the accuracy of predicted PM concentrations. The Mesoscale Model version 5 (MM5) and a 3-dimensional Eulerian chemical model (CAMx4.2) are used to predict PM2.5 and PM10 concentrations using gridded input emissions (from the "Total" group) over a 48-72 h time period for Christchurch (New Zealand) for winter 2005. The aerosol concentrations are obtained for four different chemical compositions (chemical scenarios) of the input aerosol emissions. PM2.5 chemical compositions are based on previous Christchurch winter studies and from observations in other countries with similar winter pollution problems, and used in CAMx4.2 to model seven winter 2005 heavy pollution episodes. The error between observed and modelled PM2.5 concentrations is based on predictions of fine aerosol that are derived from linear regression with PM10. It is used to find the minimum difference between modelled and observed PM2.5 for an observation site located in the Christchurch residential area. Combination of the chemical scenarios with analysis of the minimum error is used to create a new complex chemical scenario. The new complex scenario is used to re-calculate all pollution episodes to obtain new values of PM with minimum error compared with observed aerosol concentrations. Mean Absolute Error of the calculated PM2.5 (for all pollution episodes) decreased from 21-24 microg m(-3) to 14-16 microg m(-3) compared with observations. The chemical composition of the modelled PM2.5 is also discussed.  相似文献   

15.
In Baguio City, Philippines, a mountainous city of 252,386 people where 61% of motor vehicles use diesel fuel, ambient particulate matter <2.5 microm (PM(2.5)) and <10 microm (PM(10)) in aerodynamic diameter and carbon monoxide (CO) were measured at 30 street-level locations for 15 min apiece during the early morning (4:50-6:30 am), morning rush hour (6:30-9:10 am) and afternoon rush hour (3:40-5:40 pm) in December 2004. Environmental observations (e.g. traffic-related variables, building/roadway designs, wind speed and direction, etc.) at each location were noted during each monitoring event. Multiple regression models were formulated to determine which pollution sources and environmental factors significantly affect ground-level PM(2.5), PM(10) and CO concentrations. The models showed statistically significant relationships between traffic and early morning particulate air pollution [(PM(2.5)p=0.021) and PM(10) (p=0.048)], traffic and morning rush hour CO (p=0.048), traffic and afternoon rush hour CO (p=0.034) and wind and early morning CO (p=0.044). The mean early morning, street-level PM(2.5) (110+/-8 microg/m3; mean+/-1 standard error) was not significantly different (p-value>0.05) from either rush hour PM(2.5) concentration (morning=98+/-7 microg/m3; afternoon=107+/-5 microg/m3) due to nocturnal inversions in spite of a 100% increase in automotive density during rush hours. Early morning street-level CO (3.0+/-1.7 ppm) differed from morning rush hour (4.1+/-2.3 ppm) (p=0.039) and afternoon rush hour (4.5+/-2.2 ppm) (p=0.007). Additionally, PM(2.5), PM(10), CO, nitrogen dioxide (NO2) and select volatile organic compounds were continuously measured at a downtown, third-story monitoring station along a busy roadway for 11 days. Twenty-four-hour average ambient concentrations were: PM(2.5)=72.9+/-21 microg/m3; CO=2.61+/-0.6 ppm; NO2=27.7+/-1.6 ppb; benzene=8.4+/-1.4 microg/m3; ethylbenzene=4.6+/-2.0 microg/m3; p-xylene=4.4+/-1.9 microg/m3; m-xylene=10.2+/-4.4 microg/m3; o-xylene=7.5+/-3.2 microg/m3. The multiple regression models suggest that traffic and wind in Baguio City, Philippines significantly affect street-level pollution concentrations. Ambient PM(2.5) levels measured are above USEPA daily (65 microg/m3) and Filipino/USEPA annual standards (15 microg/m3) with concentrations of a magnitude rarely seen in most countries except in areas where local topography plays a significant role in air pollution entrapment. The elevated pollution concentrations present and the diesel-rich nature of motor vehicle emissions are important pertaining to human exposure and health information and as such warrant public health concern.  相似文献   

16.
To understand the influence of aerosol particles and meteorological conditions on visual range in Jinan, the capital of Shandong Province, China, PM(2.5) and PM(10) samples were collected from November 2004 to September 2005. The mass concentrations of PM(2.5) and PM(10), concentrations of water-soluble ions in PM(2.5) and concentrations of black carbon (BC) in the atmosphere were analyzed. The decrease of visual range in Jinan results from the combined influence of PM(2.5), PM(10) and meteorological conditions. For the period studied, the average light extinction coefficient, b(ext), which was estimated from an equation developed by the IMPROVE network was 292 Mm(-1). Ammonium sulfate was the major contributor to visual range impairment, accounting for 41%, while ammonium nitrate, particulate organic matter (POM) and BC made comparable contributions accounting for 20%, 22% and 18%, respectively. This highlights the significance of secondary particles ((NH(4))(2)SO(4), NH(4)NO(3), POM) in visual range impairment in Jinan. The data from this study are also compared with the long-term variations of visual range in Jinan from 1961 to 2005.  相似文献   

17.
The objective of this paper is to devise a way to facilitate the use of fixed air monitors data in order to assess population exposure. A weighting scheme that uses the data from different monitoring sites and takes into account the time-activity patterns of the study population is proposed. PM2.5 personal monitoring data were obtained within the European EXPOLIS study, in Grenoble, France (40 adult non-smoking volunteers, winter 1997). Volunteers carried PM2.5 personal monitors during 48 h and filled in time-activity diaries. Workplaces and places of residence were classified into two categories using a Geographic Information System (GIS): some volunteers' life environments are seen as best represented by PM10 ambient air monitors located in urban background sites; others by monitors situated close to high traffic density sites (proximity sites). Measurements from the Grenoble fixed monitoring network using a TEOM PM10 sampler were available across the same period for these two types of sites (PM10block and PM10prox). These data were used to compute a translator parameter deltai that forces the measured PM2.5 personal exposures (PM2.5persoi) to equate the average PM10 urban ambient air concentrations ([PM10back + PM10prox]/2) measured the same days. Average deltai was 4.2 microg/m3 (CI95%[-3.4; 11.9]), with true average PM2.5 personal exposure being 36.2 microg/m3 (28.2; 44.1). PM10 ambient levels at the proximity site and at the background site were respectively PM10prox = 43.8 microg/m3 (37.1; 50.6) and PM10back = 37.0 microg/m3 (31.8; 42.3). In order to assess the consistency of this approach, six scenarios of 'proximity' and 'background' environments were accommodated, according to traffic intensity and road distance. Deltai was estimated for the entire EXPOLIS population and for subgroups, using terciles based on the percentage of time spent in proximity by each subject. Other similar studies need to be conducted in different urban settings, and with other pollutants, in order to assess the generalizability of this simple approach to estimate population exposures from air quality surveillance data.  相似文献   

18.
PM10 and PM2.5 samples were collected near major roads and at the background locations in Macao using a TEOM1400a+ACCU system. The chemical analysis of these particles indicated the presence of 36 elements, water-soluble ions and carbonaceous species. The greatest contributors to total PM10 and PM2.5 mass were OC, sulfate, nitrate, ammonium, EC, Na, Cl and crustal elements including Si, Ca, Al, Fe, K and Mg. Organic material is the largest single fraction of airborne particulate matter in Macao. It contributes 32.8-41.5% and 38.2-48.4% of PM10 and PM2.5 at the roadsides, and as high as 29.7% and 33.4-39.4% of PM10 and PM2.5 at background locations, respectively. EC contributes 3.7-7.8% and 8.0-12.9% of PM10 and PM2.5, and crustal material is 10.2-15.4% and 7.6-12.2% of PM10 and PM2.5 near major roads, respectively. The share of EC at background locations is much lower than that at the roadsides, however, the contribution of crustal material is the same in both locations. At the roadsides, secondary aerosols, including sulfate, nitrate and ammonium, account for 16.6-29.0% and 15.8-38.0% of the total PM10 and PM2.5, respectively, as compared to 29.1-36.2% and 23.2-33.8% of total PM10 and PM2.5, respectively, at background locations. In PM2.5, Na and Cl contribute 1-3%, while the average amount of these two elements increase to 1-15% of the total PM10 in Macao.  相似文献   

19.
An exposure study of children (aged 10-12 years) living in Santiago, Chile, was conducted. Personal, indoor and outdoor fine and inhalable particulate matter (< 2.5 .m in diameter, PM2.5 and < 10 microm in diameter, PM10, respectively), and nitrogen dioxide (NO2) were measured during pilot (N = 8) and main (N = 20) studies, which were conducted during the winters of 1998 and 1999, respectively. For the main study, personal, indoor and outdoor 24-h samples were collected for five consecutive days. Similar mean personal, indoor and outdoor PM2.5 concentrations (69.5, 68.5 and 68.1 microg/m3, respectively) were found. However, for coarse particles (calculated as the difference between measured PM10 and PM2.5, PM2.5-10), indoor and outdoor levels (35.4 and 47.4 microg/m3) were lower than their corresponding personal exposures (76.3 microg/m3). Indoor and outdoor NO2 concentrations were comparable (35.8 and 36.9 ppb) and higher than personal exposures (25.9 ppb). Very low ambient indoor and personal O3 levels were found, which were mostly below the method's limit of detection (LOD). Outdoor particles contributed significantly to indoor concentrations, with effective penetration efficiencies of 0.61 and 0.30 for PM2.5 and PM2.5-10, respectively. Personal exposures were strongly associated with indoor and outdoor concentrations for PM2.5, but weakly associated for PM2.5-10. For NO2, weak associations were obtained for indoor-outdoor and personal-outdoor relationships. This is probably a result of the presence of gas cooking stoves in all the homes. Median I/O, P/I and P/O ratios for PM2.5 were close to unity, and for NO2 they ranged between 0.64 and 0.95. These ratios were probably due to high ambient PM2.5 and NO2 levels in Santiago, which diminished the relative contribution of indoor sources and subjects' activities to indoor and personal PM2.5 and NO2 levels.  相似文献   

20.
The total suspended particle (TSP), PM2.5-10 (aerodynamic diameter less than 10 microns) and PM2.5 concentration (aerodynamic diameter less than 2.5 microns) concentrations were sampled by PS-1 and Universal sampler on the roof (25 m) of the Medical and Engineering Building in the campus of Hungkuang Institute of Technology (HKIT) which is located at a height of 500 m on Da Du Mountain. The results indicated that average TSP, PM2.5-10 and PM2.5 concentrations are 0.42, 0.34 and 0.019 mg/m3 in the day time, respectively and are 0.32, 0.26 and 0.017 mg/m3 in the night time, respectively. The ratios of PM2.5-10/TSP were from 76% to 85% and from 50% to 91% for day and night period, respectively. It indicated that the major composition in the total suspended particles was PM2.5-10 in the rural site. The relationship between TSP and PM2.5-10 is TSP = 1.16PM2.5-10 + 0.027 and TSP = 1.01 PM2.5-10 + 0.058 in the day and night time, respectively. The correlation coefficient (R2) is 0.98 and 0.97 for day and night period, respectively. The relationship between PM2.5-10 and PM2.5 is PM2.5 = 0.0005PM2.5-10 + 0.019 and PM2.5 = 0.037PM2.5-10 + 0.0076 in the day and night period, respectively. The correlation coefficient (R2) is 3E-5 and 0.67 for day and night period, respectively. The relationships between TSP, PM2.5-10, PM2.5 particle concentrations and wind speed (R2) in the day time are 0.71, 0.64, 0.43, respectively and are 0.83, 0.79, 0.57, respectively in the night time. The proposed reasons are that there are more activities caused by people (students) and natural living animals which absorbed some of the particles during the day time. Thus, the correlation coefficients for the night time are better than those of day time. The particle size distributions are both bimodel in the day and night time. The major peaks in the day time appear in the particle diameter between 0.031-0.056 micron and 3.16-5.62 microns in the day period and appear between 0.017-0.031 micron and 1.78-3.16 microns in the night period. The results indicate that the particle size distribution in the day time tends to be of larger particle size mode than the night time.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号