首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Dobutamine stress echocardiography (DSE) and exercise thallium-201 single-photon emission computed tomography (SPECT) were compared for the accuracy in detecting coronary artery disease (CAD) in 51 consecutive patients. Twenty-six (group 1) of the 51 patients achieved adequate exercise end points, and 25 (group 2) did not. There were 38 patients with angiographically documented CAD. The overall sensitivity of DSE and thallium-201 SPECT in detecting CAD was 92 and 76% (p = NS), and the specificity was 77 and 77% (p = NS), respectively. The sensitivity of DSE is the same as that of SPECT in group 1 (90 vs. 90%; p = NS) and higher than that of SPECT in group 2 (94 vs. 61%; p < 0.05). In patients with CAD without a history of acute myocardial infarction or pathological Q wave on resting electrocardiogram, the sensitivity of DSE is the same as that of SPECT in group 1 (82 vs. 82%; p = NS) and also higher than that of SPECT in group 2 (90 vs. 40%; p = 0.03). The sensitivity in detecting individual coronary artery lesions with DSE and thallium-201 SPECT was not affected by the exercise level. The agreement between DSE and thallium SPECT in detecting patients with CAD was 88% in group 1 (kappa = 0.69; p < 0.001) and 76% in group 2 (kappa = 0.45; p = 0.01). The agreement in detecting vascular territories with ischemia was 68% in group 1 (kappa = 0.30; p < 0.01) and 75% in group 2 (kappa = 0.33; p < 0.001). The agreement in detecting vascular territories with a scar was 87% in group 1 (kappa = 0.55; p < 0.001) and 85% in group 2 (kappa = 0.44; p < 0.001). In conclusion, the sensitivity and specificity of DSE in detecting CAD are similar to that of thallium-201 SPECT with an exercise level > or =85% of the maximal predicted heart rate. However, in patients who cannot exercise adequately, DSE is more accurate than thallium SPECT. The agreement between DSE and thallium SPECT in detecting patients with CAD and identifying ischemia of individual vascular territories is also affected by the exercise level.  相似文献   

2.
The detection of coronary artery disease (CAD) by noninvasive methods has been hindered in women by the high rate of false-positive results. To determine the feasibility and accuracy of transesophageal dobutamine stress echocardiography for identification of CAD in women, we studied 84 patients (age 51 +/- 11 years) who underwent symptom-limited exercise treadmill testing, exercise thallium-201 scintigraphy, and coronary angiography for evaluation of anginal chest pain. Of the 84 patients, 62 had normal coronary arteries or nonsignificant coronary lesions, and 22 had significant stenosis of > or = 1 major coronary artery. During treadmill exercise, repolarization changes were observed in 16 of 21 patients with CAD and in 19 of 60 patients with normal coronary arteries. With thallium scintigraphy, a reversible defect was observed in 19 of 22 patients with CAD and in 12 of 60 patients with normal coronary arteries. Regional wall motion abnormalities during dobutamine infusion developed in 18 of 22 patients with CAD and in none of the 62 patients with normal coronary arteries. All 3 tests had similar sensitivity for detection of CAD (76% for exercise treadmill test, 86% for thallium scintigraphy, and 82% for transesophageal dobutamine stress echocardiography). However, transesophageal dobutamine stress echocardiography had significantly higher specificity than the other 2 tests (100% vs 68% for exercise treadmill test and 80% for thallium scintigraphy; p = 0.0001). Thus, transesophageal dobutamine stress echocardiography is accurate for evaluation of CAD among women presenting with chest pain; its use should be considered when more conventional tests are equivocal or technically suboptimal.  相似文献   

3.
OBJECTIVES: To compare the accuracy of dobutamine stress echocardiography (DSE) and simultaneous 99mTc sestamibi (MIBI) single-photon emission CT (SPECT) imaging for the diagnosis of coronary artery stenosis in women. PATIENTS: Seventy women with limited exercise capacity referred for evaluation of myocardial ischemia. METHODS: DSE (up to 40 microg/kg/min) was performed in conjunction with stress MIBI SPECT. Resting MIBI images were acquired 24 h after the stress test. Ischemia was defined as new or worsened wall motion abnormalities confirmed by DSE and as reversible perfusion defects confirmed by MIBI. Significant coronary artery disease was defined as > or = 50% luminal diameter stenosis. RESULTS: DSE was positive for ischemia in 35 of 45 patients with coronary artery stenosis and in 2 of 25 patients without coronary artery stenosis (sensitivity = 78% CI, 68 to 88; specificity = 92% CI, 85 to 99; and accuracy = 83% CI, 74 to 92). A positive MIBI study for ischemia occurred in 29 patients with coronary artery stenosis and in 7 patients without coronary artery stenosis (sensitivity = 64% CI, 53 to 76; specificity = 72% CI, 61 to 83; and accuracy = 67% CI, 56 to 78 [p < 0.05 vs DSE]). In the 59 vascular regions with coronary artery stenosis, the regional sensitivity of DSE was higher than MIBI (69% CI, 62 to 77 vs 51% CI, 42 to 59, p < 0.05), whereas specificity in the 81 vascular regions without significant stenosis was similar (89% CI, 84 to 94 vs 88% CI, 82 to 93, respectively). CONCLUSION: DSE is a useful noninvasive method for the diagnosis of coronary artery stenosis in women and provides a higher overall and regional diagnostic accuracy than dobutamine MIBI SPECT in this particular population.  相似文献   

4.
BACKGROUND: There is a high prevalence of coronary artery disease (CAD) in patients with diabetes mellitus. Detection of inducible ischaemia using treadmill exercise testing may be limited by the relatively poor inherent predictive accuracy of the test. The purpose of this study was to determine the value of dobutamine stress echocardiography (DSE) for the detection of CAD in patients with diabetes mellitus. METHODS: Patients with diabetes mellitus referred for cardiac assessment were considered eligible for study. DSE was performed in a standard fashion. Significant CAD was defined as a > 50% luminal diameter stenosis on coronary angiography. RESULTS: A total of 52 patients (mean age 59 years) with diabetes mellitus were studied prospectively using DSE. Risk factors for CAD included hypertension in 19, family history in 21, hypercholesterolaemia in 14, history of smoking in 38. The sensitivity, specificity, positive and negative predictive values of DSE for detection of CAD were 82, 54, 84 and 50% respectively. CONCLUSION: The specificity of DSE for CAD in patients with diabetes mellitus is low. Whether this reflects an underdetection of small vessel disease by contrast coronary angiography or whether it relates to test performance is unclear.  相似文献   

5.
Rest-redistribution 201Tl imaging is currently being used for myocardial viability detection, but the ideal parameters for territory classification have not yet been defined. The aim of this study was to define the optimal criteria for detecting viable myocardium and predicting postrevascularization recovery with rest-redistribution 201Tl SPECT. METHODS: In 29 patients with left ventricular dysfunction, tracer activity within asynergic segments was quantified on rest and redistribution 201Tl SPECT. Viability was defined by the presence of functional recovery, which was detected by comparing wall motion in baseline and follow-up echocardiography. Discriminant function analysis and receiver operating characteristic (ROC) curve analysis were used to evaluate the relationship between 201Tl data and viability. RESULTS: Of 214 dysfunctioning segments (135 a-/dyskinetic), viability was demonstrated in 115 (75 a-/dyskinetic). Both rest and redistribution 201Tl activity in these segments were significantly higher than they were in the nonviable segments (p < 0.0001). Significant (> 10%) reversibility was observed in 39% of the viable and in 36% of the nonviable segments (p = 0.81). Discriminant analysis identified redistribution activity, followed by rest activity, as the most effective predictors of functional recovery. Similar areas were found under the ROC curve for rest (0.68 +/- 0.037) and for redistribution activity (0.70 +/- 0.036) (p = 0.13). ROC curve analysis identified the optimal cutoff for redistribution activity at < 60%, with 147 of 214 (69%) segments correctly classified (sensitivity = 78% and specificity = 58%). In the subset of a-/dyskinetic segments, redistribution activity presented a significantly larger ROC curve area (0.81 +/- 0.038 compared to 0.77 +/- 0.042, p < 0.05), and 103 of 135 (76%) segments were correctly classified (sensitivity = 81% and specificity = 70%). CONCLUSION: Redistribution activity is the most important parameter to be considered in rest-redistribution 201Tl to differentiate viable from nonviable segments; rest activity is also valuable, whereas the meaning of reversibility appears limited. Cutoff values about 60% appear to give the most reasonable balance between sensitivity and specificity.  相似文献   

6.
To examine thallium-201 single-photon emission computed tomography (SPECT) with a treadmill exercise test can predict the long-term prognosis of patients with coronary artery disease, 95 patients (71 men, 24 women) who underwent a treadmill exercise test with thallium-201 SPECT from April to December 1986 were followed for 6 years. Three short-axis slices at the apical, mid- and basal-level were selected, and each slice was divided into eight segments. Each segment count was assigned a score according to the count range in the slice (score 0, count range 76-100%; 1, 51-75%; 2, 26-50%; 3, 1-25%; 4, 0%) by evaluating the mean value of the slice. The total T1 defect score of each segment in 3 slices was summed (sigma T1 defect score). The 'early sigma T1 defect score' was the sigma T1 defect score 5 min after treadmill exercise, and the 'late sigma T1 defect score' was sigma T1 defect score measured 4 h after treadmill exercise. Cardiac events occurred in 27 of the 95 patients: cardiac death 3; myocardial infarction 1; percutaneous transluminal angioplasty 16; coronary artery bypass graft 5; congestive heart failure 3. Univariate analysis showed that previous myocardial infarction (p < 0.01), exercise work load (p < 0.05), early sigma T1 defect score (p < 0.01) and late sigma T1 defect score (p < 0.01) were independent predictors of the prognosis. These results suggest that thallium-201 SPECT with the treadmill exercise test could be applicable and useful to predict long term prognosis.  相似文献   

7.
The results of rest and exercise ECG, 201Tl myocardial perfusion imaging and equilibrium radionuclide angiography were analyzed in 71 consecutive patients referred for diagnosis or evaluation of coronary artery disease (CAD). In 45 patients the diagnosis was established either by catheterization or typical history. In this group the overall sensitivity for rest/exercise ECG was 66%, for 201Tl scans 74%, for both combined 79% and for the ejection fraction response to exercise determined by radionuclide angiography 97%. If only the exercise response was considered, the corresponding sensitivity values were 58% (ECG), 50% (201Tl scans), 71% (ECG + 201Tl) and 97% (radionuclide angiography). The specificity for coronary artery disease was determined to be 71% for ECG, 86% for 201Tl scans and 42% for radionuclide angiography. All patients with false-positive results by radionuclide angiography had cardiomyopathies, thus this test has a high specificity for left ventricular dysfunction rather than for CAD alone. Criteria developed from the analysis of the test results in the 45 patients with definite diagnoses were then applied to the evaluation of 26 additional patients with atypical chest pain. A diagnosis could be made in all but 5 of them and radionuclide angiography was again the single most reliable test. Based on this study a new approach for the noninvasive evaluation of patients with suspected coronary artery disease is proposed.  相似文献   

8.
ECG-gated dual-isotope acquisition protocol involving rest imaging with 201Tl and stress 99mTc-tetrofosmin (TF) SPECT was designed for the simultaneous assessment of rest/stress myocardial perfusion and rest ventricular systolic function. This study assessed the feasibility and diagnostic accuracy of this protocol. Forty-five patients underwent the dual-isotope SPECT protocol. Twenty minutes after resting injection of 111 MBq of 201Tl, 370 MBq of 99mTc-TF was administered at a peak exercise. The dual-isotope gated SPECT acquisition was performed 1 hour later. Then, the regional count increase rate (%WT) of 99mTc-TF from end-diastole end-systole was calculated using an automated method which was developed for quantification of regional wall thickening based on circumferential profile analysis in our laboratory. Myocardial perfusion and contractility analysis was carried out using 8 segments of left ventricle with comparison of coronary angiographical findings. The sensitivity and specificity for the detection of diseased coronary vessels (> = or 75% stenosis) were 76% and 94%, respectively. Infarcted regions showing reversible defect had significantly greater %WT as compared with those with fixed defects (63 seg; 12.7 +/- 6.1% vs. 36 seg; 8.9 +/- 7.2%, p < 0.01). In conclusion, this dual-isotope protocol has some advantages; i.e., shortening an examination time, having the exact registration of stress/rest perfusion, and simultaneous evaluation of resting regional wall thickening.  相似文献   

9.
To evaluate myocardial perfusion in patients with saphenous vein graft (SVG) or internal thoracic artery graft (ITA-G), we studied 38 patients (14: SVG, 10 males and 4 females, mean age 66 +/- 9 y-o; 24: ITA-G, 18 males and 6 females, mean age 64 +/- 7 y-o) by digital subtraction angiography (DSA) of ITA-G or SVG, and thallium-201 myocardial perfusion scintigraphy on exercise or dipyridamole stress. The grafting sites were left anterior descending artery (LAD) in all patients. Normal controls (n = 22) were defined by normal coronary angiogram and no evidence of myocardial ischemia. The graft flow and flow reserve on dipyridamole were measured by Rutishauser's formula. The basal blood flow of native normal ITA, SVG and ITA-G were respectively 72 +/- 24 ml/min, 51 +/- 23 ml/min, and 36 +/- 20 ml/min. The basal ITA-G flow was significantly lower than SVG-flow (p < 0.05). The flow reserves of SVG and ITA-G were respectively 2.32 +/- 0.65 and 1.78 +/- 0.59 (p < 0.02). The incidence of moderate hypoperfusion of thallium-201 SPECT was 14.3% in SVG and 12.5% in ITA-G on exercise stress, and 35% in SVG and 50% in ITA-G on dipyridamole stress. The incidence of reversible myocardial ischemia on dipyridamole stress was significant. The graft flow in patients with normal and abnormal thallium-201 SPECT were respectively 61 +/- 21 ml/min and 33 +/- 15 ml/min in SVG (p < 0.01), 46 +/- 19 ml/min and 27 +/- 16 ml/min in ITA-G (p < 0.02). The graft flow reserve were respectively 2.69 +/- 0.38 and 1.65 +/- 0.49 in SVG (p < 0.001), 2.25 +/- 0.40 and 1.31 +/- 0.28 in ITA-G (p < 0.001). We concluded that the basal blood flow and flow reserve of ITA-G were significantly lower than those of SVG. The myocardial ischemia was occasionally documented by the thallium-201 myocardial SPECT on dipyridamole stress in patients with patent ITA-G.  相似文献   

10.
This study was designed to evaluate the feasibility of assessing myocardial viability using glucose loading followed by 201Tl SPECT. METHODS: First, the effect of insulin on the kinetics of 201Tl uptake was evaluated in isolated perfused rat hearts. Second, glucose-loading 201Tl myocardial SPECT was performed in 13 nondiabetic patients with histories of anterior myocardial infarction. Thirty minutes before acquiring rest 201Tl SPECT, 20 g of glucose were intravenously injected into the fasting subjects. Thallium perfusion defects were compared to those of conventional rest-redistribution SPECT images obtained within a 2-wk interval. SPECT images were divided into 21 segments, and a defect score in 17 segments was calculated as a sum of the semiquantitative defect scores (0 = normal; 1 = mildly decreased uptake; 2 = severely decreased uptake; 3 = absence of uptake). RESULTS: Thallium-201 uptake in isolated hearts showed a significant increase of 26% after insulin loading. Eleven (24%) of 45 segments showing perfusion defects on the conventional rest SPECT images demonstrated 201Tl uptake on glucose-loading SPECT imaging. Defect scores decreased significantly on the glucose-loading SPECT images (9.9 +/- 2.2 in early images; mean +/- s.e.) compared with the conventional rest-redistribution SPECT images (12.6 +/- 6.9 in delayed images, p < 0.05). CONCLUSION: Glucose-loading SPECT represents a superior method for assessing myocardial viability using 201Tl.  相似文献   

11.
BACKGROUND: Critical analysis of treadmill exercise testing (TMET) for the detection of coronary artery disease has revealed many shortcomings. Excellent diagnostic accuracy has been reported for dobutamine stress echocardiography (DSE). METHODS: A prospective comparison of DSE and TMET for the detection of coronary artery disease in routine clinical practice was performed using contrast cineangiography (significant stenosis > or = 50%) as a gold standard. RESULTS: A total of 116 patients (82 men, 34 women) were studied. Significant stenosis was detected by coronary angiography in 92 patients (79%). Single vessel disease occurred in 28, double-vessel disease in 32, and multivessel disease in 32 patients. Although sensitivity of DSE was better than that of TMET (82 versus 40%), specificity was worse (63 versus 79%). Positive predictive values for both DSE and TMET were good at 89 and 87%, respectively, whereas negative predictive values were poor for both (47% for DSE, 26% for TMET). CONCLUSIONS: Overall, DSE performs better than TMET in terms of sensitivity and positive and negative predictive value. Its lower specificity than that of TMET may lead to more patients being referred for diagnostic coronary angiography. The poor negative predictive value of DSE and TMET means that one should not be falsely reassured by normal results.  相似文献   

12.
To evaluate the diagnostic value of the postexercise systolic blood pressure (SBP) response for detecting and evaluating the presence of coronary artery disease (CAD), treadmill testing was conducted in 130 subjects with normal blood pressure and 51 patients with hypertension, each of whom underwent selective coronary angiography. A total of 48 subjects with normal blood pressure and 27 patients with hypertension had no significant narrowing of the coronary artery (control subjects), whereas 82 subjects with normal blood pressure and 24 patients with hypertension had significant narrowing (patients with CAD). The postexercise SBP response was defined on the basis of the SBP ratio (i.e., the SBP at 3 minutes of recovery divided by that at peak exercise). An SBP ratio that exceeded 0.90 (cutoff point for discriminating control subjects from patients with CAD) was considered to be an abnormal SBP response. In the subjects with normal blood pressure, the abnormal SBP response identified CAD as accurately as did ST-segment depression. In the patients with hypertension, the diagnostic accuracy was increased significantly by combining the abnormal SBP response and ST-segment depression (p < 0.01). The SBP ratio increased with the number of diseased coronary arteries. Ten of the 14 patients with a narrowing of the left main coronary artery had an SBP ratio higher than 1.00. The postexercise SBP response may be useful for detecting CAD in patients with and without hypertension and for evaluating the severity of CAD.  相似文献   

13.
OBJECTIVES: This study evaluated the diagnostic value of dipyridamole plus low level treadmill exercise (dipyridamole stress) thallium-201 single-photon emission computed tomography (SPECT) in patients taking antianginal drugs. BACKGROUND: Dipyridamole stress is the major substitute for maximal exercise in patients referred for myocardial perfusion imaging. Although antianginal drugs are commonly suspended before exercise, dipyridamole stress is usually performed without discontinuing these drugs. METHODS: Twenty-six patients underwent two dipyridamole perfusion studies: the first without (SPECT-1) and the second with (SPECT-2) antianginal treatment. Twenty-one patients (81%) received calcium antagonists, 19 (73%) received nitrates, and 8 (31%) received beta-blockers. Eighteen of the patients underwent coronary angiography. Data are presented as the mean value +/- SD. RESULTS: Visual scoring yielded significantly larger and more severe reversible perfusion defects for SPECT-1 than for SPECT-2. Quantitative analysis showed larger perfusion defects on stress images of SPECT-1 in the left anterior descending coronary artery (LAD) (25 +/- 21% vs. 17 +/- 15%, p = 0.003), left circumflex coronary artery (LCx) (56 +/- 35% vs. 48 +/- 36%, p = 0.03) and right coronary artery (RCA) (36 +/- 27% vs. 25 +/- 24%, p = 0.008) territories. Individual vessel sensitivities in the LAD, LCx and RCA territories were 93%, 79% and 100% for SPECT-1 and 64%, 50% and 70% for SPECT-2, respectively. These differences were highly significant for the LAD (p = 0.004) and LCx (p = 0.00004) territories. The overall individual vessel sensitivity of SPECT-1 was significantly higher than that of SPECT-2 (92% vs. 62%, p = 0.000003). Specificity was not significantly different in SPECT-1 compared with SPECT-2 (80% and 93%, p = 0.33). CONCLUSIONS: Continued use of antianginal drugs before dipyridamole plus low level treadmill exercise thallium-201 SPECT may reduce the extent and severity of myocardial perfusion defects, resulting in underestimation of coronary artery disease.  相似文献   

14.
Quantitatively estimating functional reserve of blood supply to the legs in patients with peripheral arterial occlusive disease (PAOD) remains a clinical issue. This study was designed to investigate the regional blood supply to the legs in PAOD patients during exercise by use of thallium 201 (201Tl) whole-body imaging in comparison with transcutaneous PO2 (tcPO2) measurement. Thirty-three patients with PAOD and 10 subjects without PAOD (control) performed an incremental cycle ergometry (CE), while tcPO2 was continuously registered on the involved calf. In the last minute of exercise, 2 mCi of 201Tl was injected intravenously and the 201Tl whole-body images were taken immediately (stress) and four hours (redistribution) following stress with a dual-head camera system. Regional blood supply (RBS) (%) was calculated from the geometric mean counts of the region of interest divided by the total counts of the whole body. The performance of PAOD patients was reduced in doing CE, and tcPO2 fell distinctly in PAOD patients (from 51 to 19 mmHg) whereas it increased in controls (from 57 to 67 mmHg). The RBS in PAOD patients was obviously reduced in comparison with that of controls. While in controls the RBS of the calf (3.1%) at stress did not differ from that at redistribution (3.4%), in PAOD patients the redistribution RBS (2.8%) increased as compared with that of stress (1.5%). There was a hyperbolic relationship between stress RBS of the calf and the velocity of tcPO2 fall in PAOD patients during exercise test (velocity of tcPO2 fall = -0.032 + 0.39/RBS, r2 = 0.54, P < 0.05). In conclusion, the RBS determined by 201Tl whole-body imaging is comparable to the tcPO2 measurement in differentiating patients with PAOD from subjects without PAOD during exercise. Regional 201Tl uptake reflects regional blood supply in PAOD patients. There is a hyperbolic relationship between the RBS derived from 201Tl whole-body imaging and tcPO2 in PAOD patients during exercise, implying that in a critical ischemia the lower the RBS is, the more steeply the tcPO2 decreases.  相似文献   

15.
The purpose of the present study is to assess the effect of nicorandil, a coronary vasodilator with a mechanism of potassium channel opening, on the abnormal myocardial 201Tl perfusion evoked by exercise. Eleven patients who had a history of typical angina, positive exercise electrocardiograms, positive 201Tl scintigraphy, nearly normal coronary arteriograms, and negative coronary vasospasm underwent exercise 201Tl scintigraphies under no medication (baseline test) and administration of nicorandil (nicorandil test). 201Tl was injected at a matched workload in both tests. Nicorandil did not alter heart rate, blood pressure, or the rate-pressure product at the end of the exercise, but it significantly improved the extent score from 0.37 +/- 0.22 to 0.20 +/- 0.15 (p < 0.05) and the severity score from 33.9 +/- 32.2 to 13.5 +/- 16.4 (p < 0.05), and also significantly hastened the 201Tl mean washout rate from 30.5 +/- 14.8% to 37.4 +/- 13.1% (p < 0.05). Anginal symptoms disappeared in 3 of 5 cases and ST depression improved in 5 of 7 cases after nicorandil. We conclude that nicorandil augments coronary flow reserve, possibly due to a reduction of vasotone in the small coronary arteries.  相似文献   

16.
The purpose of this study is to determine whether left ventricular dysfunction following coronary artery spasm by 123I-BMIPP myocardial imaging. To reveal the clinical efficacy of 123I-BMIPP SPECT, 20 patients with vasospastic angina were studied using resting, 3-hour delayed image with 123I-BMIPP and exercise, 3-hour delayed image with 201Tl SPECT. 123I-BMIPP uptake was decreased compared to 201Tl (discordant) in 12 patients (60%) and in 49/100 myocardial segments (49%). The extent and severity score in resting image with 123I-BMIPP were significantly larger than that in delayed image with 201Tl (p < 0.01). In 123I-BMIPP SPECT, the severity score in the latest ischemia were significantly larger than that in others. The incidence of a complete agreement of decreased 123I-BMIPP uptake and coronary artery spasm was significantly higher (75%) than that in 201Tl (28%, p < 0.01). Furthermore, compared to 201Tl uptake, decreased 123I-BMIPP uptake much more corresponded to reduced wall motion in 9 of patients with mismatching. The severity of regional wall motion abnormality was significantly correlated with severity score of 123I-BMIPP. Late redistribution in delayed image with 123I-BMIPP was seen in 6 patients. The regional washout rate and the severity of regional wall motion abnormality in 6 patients was significantly lower than that in others (p < 0.05). Thus, metabolic abnormality assessed by 123I-BMIPP is well associated with left ventricular asynergy and spastic region in patients with vasospastic angina. In conclusion, 123I-BMIPP SPECT may sensitively delineate the impaired myocardium following coronary artery spasm, and it is very useful in diagnosing and estimating the severity of vasospastic angina.  相似文献   

17.
Although the accuracy of dobutamine stress echo (DSE) for detecting coronary artery disease (CAD) has been established, its role in determining prognosis is less well defined. The purpose of this study was to evaluate the prognostic significance of DSE in patients with known or suspected CAD. Follow-up was obtained on 291 patients an average of 15 months after clinically indicated DSE. Studies were stratified with respect to resting and inducible wall motion abnormalities into 1 of 4 responses: normal, ischemic, fixed, and mixed. Hard end points of nonfatal myocardial infarction and cardiac death were tabulated for outcome. Statistically significant differences in the incidence of hard cardiac end points were noted for 2 of 4 DSE responses. A normal DSE was associated with a statistically lower likelihood of a hard cardiac event than was a DSE demonstrating resting or inducible abnormalities (p = 0.001). DSE with a mixed response (resting abnormality with additional inducible ischemia) was associated with a higher likelihood of cardiac events by multivariate analysis (p = 0.003). By multiple logistic regression analysis of dobutamine response, age, and cardiac risk factors, only a mixed response on DSE was independently associated with the occurrence of a hard cardiac event in the follow-up period. In addition, left ventricular dysfunction on the resting echocardiogram was associated with a worse prognosis in patients with major noncardiac disease. We conclude that dobutamine response is an independent predictor of cardiac events compared with traditional risk factor analysis and that DSE can identify high- and low-risk subsets of patients with known or suspected CAD.  相似文献   

18.
We present a simultaneous gated SPECT (G-SPECT) dual-isotope technique using 201Tl for perfusion and 99mTc blood-pool labeling for function imaging. METHODS: Seventeen patients (13 with previous myocardial infarction, MI) and a control group of three normal volunteers were investigated. They received, 15 min after a 201Tl stress/redistribution protocol with reinjection, 900-950 MBq 99mTc-HSA for blood-pool labeling. Eight frames per R-R interval were recorded in the G-SPECT mode with three windows: window A with 20% centered at 71 keV for 201Tl, window B with 10% centered at 105 keV for Tc scatter contamination and window C centered at 140 keV with 20% for 99mTc. Nongated, crosstalk-corrected 201Tl SPECT perfusion images were reconstructed according to normalized projection-by-projection subtraction from data from windows A and B. G-SPECT data from window C were reconstructed with the same reconstruction limits to allow topographic correlations of left ventricular perfusion and wall motion abnormalities. Polar maps of perfusion and function were used to divide the myocardium into 20 segments. Perfusion was expressed as the percentage of thallium uptake and function corresponding to diastolic to systolic shortening normalized by end diastolic volume. RESULTS: Segmental comparison of uncontaminated-to-contaminated and corrected 201Tl patient images demonstrated an overall agreement score of 93%, with a kappa statistic of 0.76 +/- 0.06 when normal perfused segments were excluded. Segmental matching of perfusion against function at rest showed no correlation for the 10 patients with preserved ejection fraction of 59% +/- 8% nor for the control group. For the remaining seven patients with an ejection fraction of 34% +/- 10%, there was linear correlation between perfusion and function (r2 = 0.61). CONCLUSIONS: The feasibility of dual TI-Tc G-SPECT was examined at rest and suggests low perfusion hypokinesis that matches linear dependence for CAD patients with low ejection fraction.  相似文献   

19.
OBJECTIVES: We sought to determine the prognostic capabilities of exercise thallium (Tl)-201 tomographic imaging performed relatively early (within 2 years) after coronary artery bypass graft surgery (CABG). BACKGROUND: Exercise testing is commonly performed after CABG, but few data exist demonstrating its prognostic value in this setting. METHODS: Four hundred eleven patients were followed up for a median duration of 5.8 years. Eleven prospectively chosen clinical, exercise and Tl-201 variables were tested for their associations with outcome end points by means of proportional hazards regression models. RESULTS: During follow-up there were 60 deaths from any cause, 53 initial cardiac deaths or nonfatal myocardial infarctions (MIs) and 22 late (>3 months after the Tl-201 study) revascularization procedures. The number of abnormal Tl-201 segments on the postexercise image was the only variable in the multivariate analyses to show a significant association with all three outcome end points: chi-square 7.3, p = 0.007 for overall mortality; chi-square 8.1, p = 0.004 for cardiac death or MI; chi-square 7.8, p = 0.005 for any cardiac event. Other independent predictors of outcome were exercise duration (chi-square 10.7, p = 0.001) and age (chi-square 3.9, p = 0.049) for overall mortality and exercise angina score (chi-square 8.7, p = 0.003) for cardiac death or MI. The 5-year survival rate free of cardiac death or MI was 93% for patients without angina and a normal image or small postexercise perfusion defect versus 71% for patients with angina and a medium or large defect. CONCLUSIONS: Exercise Tl-201 imaging performed within 2 years of CABG can stratify patients into low and high risk subgroups.  相似文献   

20.
BACKGROUND: Exercise testing in women is associated with a high incidence of false-positive ECG changes and should be combined with an imaging study. The QT dispersion (QTD), recorded as the difference between maximum and minimum QT intervals on a 12-lead ECG, is sensitive to myocardial ischemia and may improve the accuracy of exercise testing in women. METHODS AND RESULTS: Exercise ECGs were analyzed in 64 women who had undergone exercise ECG and coronary angiography for clinical indications: 20 patients with normal exercise stress test and nonsignificant (< or = 50% diameter narrowing of a major epicardial coronary artery) coronary artery disease (CAD) on angiography (true-negative; TN group), 20 patients with positive exercise stress tests (> or = 1 mm ST-segment depression or reversible perfusion defects) and significant CAD (true-positive; TP group), and 24 patients with positive exercise stress tests but no significant CAD (false-positive; FP group). The exercise QTD was 45+/-15 ms in TN, 80+/-23 ms in TP (P<.0001 versus TP), and 41+/-14 ms in FP (P=NS versus TN and <.0001 versus TP) groups. A stress QTD of > 60 ms had a sensitivity of 70% and specificity of 95% for the diagnosis of significant CAD compared with 55% (P<.05) and 63% (P<.01), respectively, for > or = 1 mm ST-segment depression during stress. When QTD of > 60 ms was added to ST-segment depression as a condition for positive test, the specificity increased to 100%. CONCLUSIONS: Exercise QTD is an easily measurable ECG variable that significantly increases the accuracy of exercise testing in women.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号