首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Borehole heat exchangers are the fundamental component of ground coupled heat pumps, which are now widely employed for energy saving in building heating and cooling. The improvement of the thermal efficiency of Coaxial Borehole Heat Exchangers (CBHEs) is pursued in this paper by investigating the effects of thermal short-circuiting and of flow rate, as well as of the constituent materials and of the geometrical configuration of the CBHE cross section. The analysis is performed by means of finite-element simulations, implemented through the software package COMSOL Multiphysics. The real 2-D axisymmetric unsteady heat transfer problem is modelled, for both winter and summer working conditions, by considering CBHEs with a length of 100 m placed either in a high conductivity or in a low conductivity ground. The results point out that the effects of flow rate and of thermal short-circuiting are both important, and that the latter can be reduced considerably by employing a low conductivity material, such as PPR80, for the inner tube. Finally, it is shown that the performance of the CBHE could be improved, with respect to the commonly used geometry, by increasing the diameter of the inner tube while leaving the outer tube unchanged.  相似文献   

2.
Fluid mechanics and heat transfer are studied in a double-tube heat exchanger that uses the combustion gases from natural gas in a porous medium located in a cylindrical tube to warm up air that flows through a cylindrical annular space. The mathematical model is constructed based on the equations of continuity, linear momentum, energy and chemical species. Unsteady fluid mechanics and heat transfer by forced gas convection in the porous media, with combustion in the inner tube, coupled to the forced convection of air in the annular cylindrical space are predicted by use of finite volumes method. Numerical simulations are made for four values of the annular air flow Reynolds number in the range 100 ? Re ? 2000, keeping constant the excess air ψ = 4.88, the porosity ε = 0.4, and the air–fuel mixture inlet speed Uo = 0.43 m/s. The results obtained allow the characterization of the velocity and temperature distributions in the inner tube and in the annular space, and at the same time to describe the displacement of the moving combustion zone and the annular porous media heat exchanger thermal efficiency. It is concluded that the temperature increase is directly related to the outer Reynolds number.  相似文献   

3.
The paper presents numerical investigations of a three fluid heat exchanger (TFHE), which is an improvement on the double pipe heat exchanger, where a helical tube is inserted in the annular space between two straight pipes. The helical tube side fluid, that is, hot water continuously transfers heat to the outer annulus side fluid and innermost tube side fluid. The heat transfer and pressure drop characteristics of the TFHE are assessed for different flow rates and inlet temperatures. With an increment in the volumetric flow rate of the helical tube side fluid and outer annulus side fluid, the overall heat transfer coefficient increases, and the effectiveness decreases for heat transfer from the helical tube side fluid to outer annulus side fluid in both parallel flow and counter flow configurations. It is also observed that with increment in the helical tube side fluid inlet temperature, the overall heat transfer coefficient and effectiveness increases for heat transfer from the helical tube side fluid to outer annulus side fluid in both flow configurations. The parameter, JF factor, has been proposed to evaluate the thermohydraulic behavior of the TFHE, where it is obtained that the behavior of the TFHE is better at a lower helical tube side fluid velocity and higher outer annulus side fluid velocity.  相似文献   

4.
A horizontal double-pipe heat exchanger with an inverted outer equilateral triangular tube is modeled to numerically investigate the low-temperature thermal energy storage capability of an impure phase change material (PCM). The energy source fluid (hot water) flows through the inner tube and transfers heat to the PCM (heat sink) residing in the annular gap. The results show that the inlet temperature of the heat transfer fluid (HTF) has a significant effect on the melting process compared with the mass flow rate (MFR). The configuration, as well the concentricity/eccentricity of the inner tube has a great influence on the energy storage.  相似文献   

5.
Y.B. Tao 《Solar Energy》2010,84(10):1863-1872
A unified two-dimensional numerical model was developed for the coupled heat transfer process in parabolic solar collector tube, which includes nature convection, forced convection, heat conduction and fluid-solid conjugate problem. The effects of Rayleigh number (Ra), tube diameter ratio and thermal conductivity of the tube wall on the heat transfer and fluid flow performance were numerically analyzed. The distributions of flow field, temperature field, local Nu and local temperature gradient were examined. The results show that when Ra is larger than 105, the effects of nature convection must be taken into account. With the increase of tube diameter ratio, the Nusselt number in inner tube (Nu1) increases and the Nusselt number in annuli space (Nu2) decreases. With the increase of tube wall thermal conductivity, Nu1 decreases and Nu2 increases. When thermal conductivity is larger than 200 W/(m K), it would have little effects on Nu and average temperatures. Due to the effect of the nature convection, along the circumferential direction (from top to down), the temperature in the cross-section decreases and the temperature gradient on inner tube surface increases at first. Then, the temperature and temperature gradients would present a converse variation at θ near π. The local Nu on inner tube outer surface increases along circumferential direction until it reaches a maximum value then it decreases again.  相似文献   

6.
The long-term performance of double U-tube BHE (borehole heat exchanger) fields is investigated by finite element simulations, performed through the software package COMSOL Multiphysics (©COMSOL, Inc.), for grounds in which the effects of groundwater movement are negligible. Six time periodic heat loads with period of 1 year are examined, with either full compensation, or partial compensation or no compensation of winter heating with summer cooling. A single BHE surrounded by infinite ground and the following BHE field configurations are analyzed: a single line of infinite BHEs, two staggered lines of infinite BHEs, a square field of infinite BHEs. For each BHE field configuration, four different distances between adjacent BHEs and two values of the ground thermal conductivity are considered. The undisturbed ground temperature is assumed equal to 14 °C, and −5 °C is prescribed as the lowest allowed temperature for the working fluid. For each BHE field geometry, heat load and ground thermal conductivity, plots of the minimum annual value of the fluid temperature for a period of 50 years are reported, and the pairs “distance – heat load” which keep the fluid temperature above the prescribed limit are evidenced.  相似文献   

7.
An experimental and numerical study on convection heat transfer of water flowing through an alternating cross‐section flattened (ACF) tube are investigated in this paper. The thermal‐fluid characteristics were evaluated by numerical simulation. The test run conditions covered a mass flux of 200 to 800 kg m?2 s?1, a heat flux of 10 kW/m2, and an inlet temperature of 40°C. The results showed that the Nusselt number increased with the increase in mass flux. Moreover, the heat transfer was also affected by the flow characteristics. Vortices were formed at the curved wall, and their intensities were increased along the flow direction. It was also found that the heat transfer and pressure drop were larger than that of the circular tube. However, the thermal performance was greater than the pressure loss penalty. The comparison results showed that the ACF tube had better performance than the circular tube. Further, the details of heat transfer, flow resistance, and fluid behavior were investigated and discussed in this study.  相似文献   

8.
An experimental analysis is presented to establish the thermal performance of a latent heat thermal storage (LHTS) unit. Paraffin is used as the phase change material (PCM) on the shell side of the shell and tube‐type LHTS unit while water is used as the heat transfer fluid (HTF) flowing through the inner tube. The fluid inlet temperature and the mass flow rate of HTF are varied and the temperature distribution of paraffin in the shell side is measured along the radial and axial direction during melting and solidification process. The total melting time is established for different mass flow rates and fluid inlet temperature of HTF. The motion of the solid–liquid interface of the PCM with time along axial and radial direction of the test unit is critically evaluated. The experimental results indicate that the melting front moves from top to bottom along the axial direction while the solidification front moves only in the radial direction. The total melting time of PCM increases as the mass flow rate and inlet temperature of HTF decreases. A correlation is proposed for the dimensionless melting time in terms of Reynolds number and Stefan number of HTF. © 2013 Wiley Periodicals, Inc. Heat Trans Asian Res; Published online in Wiley Online Library ( wileyonlinelibrary.com/journal/htj ). DOI 10.1002/htj.21120  相似文献   

9.
Natural convection induced heat transfer has been studied over the outer surface of helically coiled-tube heat exchangers. Several different geometrical configurations (curvature ratio δ ε [0.035, 0.082]) and a wide range of flow parameters (60 <= Ttank <= 90, Tin = 19 and 60 <= Tin <= 90, Ttank = 20, 4000 <= Re <= 45000) have been examined to broaden the validity of the results gained from this research. A fluid-to-fluid boundary condition has been applied in the numerical calculations to create the most realistic flow configurations. Validity of the numerical calculations has been tested by experiments available in the open literature. Calculated results of the inner side heat transfer rate have also been compared to existing empirical formulas and experimental results to test the validity of the numerical computation in an independent way from the outer side validation of common helical tube heat exchangers. Water has been chosen to the working fluid inside and outside of the coiled tube (3 < Pr < 7). Outer side heat transfer rate along the helical tube axis has been investigated to get information about the performance of the heat transport process at different location of the helical tube. It was found that the outer side heat transfer rate is slightly dependent on the inner flow rate of any helical tube in case of increasing temperature differences between the tank working fluid temperature and the coil inlet temperature. A stable thermal boundary layer has been found along the axial direction of the tube.In addition to this the qualitative behavior of the peripherally averaged Nusselt number versus the axial location along the helical tube function is strongly dependent on the direction of the heat flow (from the tube to the storage tank and the reversed direction). Inner side heat transfer rate of helical coils have also been investigated in case of fluid-to-fluid boundary conditions and the calculation results have been compared with different prediction formulas published in the last couples of decades.  相似文献   

10.
Non-symmetric heat flux distributions in terms of gravity in solar collector tubes influence buoyancy-driven secondary flow which has an impact on the associated heat transfer and pressure drop performance. In this study the influence of the asymmetry angle (0°, 20°, 30° and 40°) with regard to gravity for non-uniform heat flux boundaries in a horizontal circular tube was investigated numerically. A stainless steel tube with an inner diameter of 62.68 mm, a wall thickness of 5.16 mm, and a length of 10 m was considered for water inlet temperatures ranging from 290 K to 360 K and inlet Reynolds numbers ranging from 130 to 2000. Conjugate heat transfer was modelled for different sinusoidal type outer surface heat flux distributions with a base-level incident heat flux intensity of 7.1 kW/m2. It was found that average internal heat transfer coefficients increased with the circumferential span of the heat flux distribution. Average internal and axial local heat transfer coefficients and overall friction factors were at their highest for symmetrical heat flux cases (gravity at 0º) and lower for asymmetric cases. The internal heat transfer coefficients also increased with the inlet fluid temperature and decreased with an increase in the external heat loss transfer coefficient. Friction factors decreased with an increase in fluid inlet temperature or an increase in the external heat loss transfer coefficients of the tube model.  相似文献   

11.
Laminar conjugate heat transfer by natural convection and conduction in a vertical annulus formed between an inner heat generating solid circular cylinder and an outer isothermal cylindrical boundary has been studied by a numerical method. It is assumed that the two sealed ends of the tube to be adiabatic. Governing equations are derived based on the conceptual model in the cylindrical coordinate system. The governing equations have been solved using the finite volume approach, using SIMPLE algorithm on the collocated arrangement. Results are presented for the flow and temperature distributions and Nusselt numbers on different cross sectional planes and longitudinal sections for Rayleigh number ranging from 105 to 108, solid volume fraction of 0‹φ‹0.05 with copper-water nanofluid as the working medium. Considering that the driven flow in the annular tube is strongly influenced by orientation of tube, study has been carried out for different inclination angles.  相似文献   

12.
A three-dimensional coupled model of heat transfer tube and trefoil tube support plate (TSP) is developed based on a full-size steam generator (SG). The CFX thermal phase change model is adopted to numerically investigate the flow and heat transfer behaviors of the secondary side fluid. And the effects of trefoil TSPs and inlet subcooling on the thermal-hydraulic characteristics of tube bundle are obtained. The calculation model reasonably reveals the distributions of the flow and heat transfer parameters in the SG, especially in trefoil TSP regions. Based on the across flow velocity and density of the secondary side fluid in U-bend region, the most severe flow-induced vibration damage is predicted at the angles of 110° on the hot leg and 60° on the cold leg, respectively. Due to the effects of trefoil TSPs, vortexes are induced, the outer wall temperature in the circumferential direction shows periodic characteristic in TSP regions, which increases the possibility of aggressive solutes deposition and U-tubes rupture. In addition, inlet subcooling of the secondary side fluid has significant effects on the SG. As inlet subcooling decreases, the heat transfer is enhanced. The numerical simulation results obtained may provide guidance to facilitate the optimal design and in-depth thermal-hydraulic analysis of TSPs and SGs.  相似文献   

13.
The effect of step height on heat transfer to a radially outward expanded air flow stream in a concentric annular passage was studied experimentally. Separation, subsequent reattachment and developed air flow occurred in the test section at a constant heat flux boundary condition. The experimental investigation was focused on the effect of separation flow on the local and average convection heat transfer. The experimental set-up consists of concentric tubes to form annular passage with a sudden reduction in passage cross-section created by the variations of outer tube diameter at the annular entrance section (D). The outer tube of test section was made of aluminium having 83 mm inside diameter and 600 mm heated length, which was subjected to a constant wall heat flux boundary condition. The investigation was performed in a Re range of 17050-44545, heat flux varied from 719 W/m2 to 2098 W/m2 and the enhancement of step heights were, s = 0 (without step), 6 mm, 14.5 mm and 18.5 mm, which refer to d/D = 1, 1.16, 1.53 and 1.80, respectively.For all cases, an increase in the local heat transfer coefficient was obtained against enhanced heat flux and or Re. The effect of step variation is prominent in heat transfer at the separation region which increases with the rise of step height and it shows a little effect in the redevelopment region. In the separation region, the local heat transfer coefficient increases up to the maximum value at the reattachment point and then decreases gradually in the redevelopment region. The results have been correlated and compared with forced convection heat transfer in annular passage and show a maximum enhancement of 18% (Smax = 18.5 mm) within the range of step height. The present results show good agreement with previous works and have followed similar trends.  相似文献   

14.
讨论了混合对流条件下环形通道中浮升力对流动及传热的影响。实验时用LDA测量了水向下流过竖直环形通道时的平均流速和湍流强度。对于逆浮升力方向的流动情况,湍流速度脉动和湍流剪切应力都因浮升力的影响而增加,从而传热得到了增强。当浮升力的影响特别大时。靠近环形内壁的流动出现反向流,在这种情况下即使流动在无浮升力影响时是层流。湍流也会由于浮升力的存在而产生,传热维持较好的效果。  相似文献   

15.
In this paper, we are concerned with the heating fluid in the annular space between two concentric cylinders where the inner cylinder with cavities is rotated and the outer cylinder is at rest. The effects of cavities of the inner cylinder on the heating fluid and the cavitation behavior are examined. We measured the flow rate, rotating speed of rotor, friction torque, temperature rise and pressure drop between inlet and outlet of this device. The flow rate of water ranged from 0.42×10^-4 to 4.59×10^-4 ma/s at the inlet. The friction torque and the quantity of heat of the inner cylinder with cavities were larger than the case of no cavities, and they increased as the rotating speed of inner cylinder increased. The efficiency was close to about 1 as the rotating speed of inner cylinder increased. The behavior of cavitation in the cavity on the surface of inner cylinder was discussed.  相似文献   

16.
This study aims to investigate the roles of pertinent parameters on the mixed convection of complex liquids in annular devices. The investigated area consists of two circular cylinders with fixed and heat walls. Both cylinders are enclosed within a circular room with a cold wall and rotate regularly. The zone between the inner obstacles and the outer space contains complex power-law fluids. This investigation is numerically achieved by using the package ANSYS-CFX, which is based on the finite-volume method. The parameters studied in this study are the arrangement and size of inner tubes (d/D), the rotational speed of outer space, the rheological nature of fluids (n), and the relative concentration of thermal buoyancy force. These pertinent parameters were quantitatively expressed for the following values: d/D (= 0.1, 0.25, and 0.45); Reynolds number (Re = 1 to 20); flow behavior index (n = 0.6, 1 and 1.6); Richardson number (Ri = 0 to 100), respectively. It was found that increasing the thermal buoyancy value and the rotational speed of the outer container increases the rate of heat transfer of the cylinders in the vertical and horizontal arrangement. For example, for shear-thinning fluid (n = 0.6), raising the value of Ri from 0 to 100 increases Nu by 59.67% for d/D = 0.1. Also, the arrangement of the two cylinders differently affects the dynamic behavior of the fluid within the studied space.  相似文献   

17.
In this paper, a novel bayonet tube high temperature heat exchanger (HTHE) with inner and outer fins is presented. It can be used in the ultra high temperature environment, such as hydrogen production, very high temperature reactor and externally fired combined cycle. Numerical investigation of heat transfer performance on the inside of bayonet element has been conducted for structure design. The numerical results suggest that the inner fin and inner tube should not be welded together. It is recommended that the air enters from the inner tube and exits from the annular space in the high temperature zone. A high temperature experimental system has been established to test the heat transfer and pressure drop characteristics of the HTHE. The surface area density of the tested HTHE is 6 times higher than that of the bare bayonet tube heat exchanger. The experimental results indicate that the mass flow rate on both sides and inlet temperature on the fuel gas side have a significant effect on the heat transfer rate and effectiveness, while the pressure drop ratios are mainly affected by the mass flow rate rather than the inlet temperature. Comparison between the tested HTHE and the similar HTHE without fins indicates that the proposed HTHE has a significant potential to improve the comprehensive heat transfer performance.  相似文献   

18.
In the present work, convection heat transfer of water at supercritical pressure in a narrow annulus at low Reynolds numbers (less than 1500) has been investigated numerically. The continuity, momentum and energy equations have been solved simultaneously using computational fluid dynamics techniques with the inlet Reynolds number ranging from 250 to 1000, Grashof number from 2.5 × 105 to 1 × 106 and the inlet fluid temperature from 360 °C to 380 °C. In all of the case studies, a sub-cooled water flow at supercritical pressure (25 MPa) and a temperature close to the pseudo-critical point enters the annular channel with constant heat flux at inner wall surface and insulated at outer wall. To calculate the velocity and temperature distributions of the flow, discretized form of the governing equations in the cylindrical coordinate system are obtained by the finite volume method and solved by the SIMPLE algorithm. It has been shown that the effect of buoyancy is strong and causes extensive increase in velocity near the inner wall, and consequently an increase in the convective heat transfer, which is desirable. Besides, the effects of inlet Reynolds number, Grashof number and inlet temperature on the velocity distribution and also on the heat transfer have been investigated.  相似文献   

19.
Laminar natural convection between two coaxial vertical rectangular cylinders is numerically studied in this work. The outer cylinder is connected with vertical rectangular inlet and outlet pipes. The inner cylinder dissipates volumetric heat. The fluid flow and heat transfer characteristics between the cylinders are analyzed in detail for various Grashof numbers. The heat transfer rates on the individual faces of the inner cylinder are reported. The bottom face of the inner cylinder is found to associate with much higher heat rates than those of the other faces. The average Nusselt number on bottom face is more than 2.5 times of the Nusselt number averaged on all the faces. At a given elevation, local Nusselt number on the inner cylinder faces increases towards cylinder edges. The effect of thermal condition of the walls of outer cylinder, inlet and outlet on the natural convection is analyzed. The thermal condition shows strong qualitative and quantitative impact on the fluid flow and heat transfer. The variation of induced flow rate, dimensionless maximum temperature and average Nusselt numbers with Grashof number is studied. Correlations for dimensionless buoyancy-induced mass flow rate and temperature maximum are presented.  相似文献   

20.
The paper presents the geometric optimization of the micro-heat sink with straight circular microchannels with inner diameter of Di = 900 μm. The inlet cross-section has a rectangular shape and positioned tangentially to the tube axis with the four different geometries. The fluid flow regime is laminar and water with variable fluid properties is used as a working fluid. The heat flux spread through the bottom sink surface is q = 100 W/cm2. Thermal and hydrodynamic performances of the heat sink are compared with results obtained for conventional channel configuration with lateral inlet/outlet cross-section. Besides, the results are compared with the tangential micro-heat sink with Di = 300 μm. For all the cases, the thermal and hydrodynamic results are compared on a fixed pumping power basis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号