 共查询到20条相似文献,搜索用时 390 毫秒
1.
This paper is Part 2 of the study on the exergetic and thermoeconomic analysis of diesel engine powered cogeneration (DEPC) systems. In Part 1, formulations and procedure for such a comprehensive analysis are provided while this paper provides an application of the developed formulation that considers an actual DEPC plant installed in Gaziantep, Turkey. The plant has a total installed electricity and steam generation capacities of 25.3 MW and 8.1 tons/h at 170 °C, respectively. Exergy destructions, exergy efficiencies, exergetic cost allocations, and various exergoeconomic performance parameters are determined for the entire plant and its components. The exergy efficiency of the plant is determined to be 40.6%. The exergoeconomic analysis is based on specific cost method (SPECO) and it is determined that the specific unit exergetic cost of the power produced by the plant is 10.3 $/GJ.  相似文献   

2.
P. Lin  R.Z. Wang  Z.Z. Xia 《Renewable Energy》2011,36(5):1401-1412
Two-stage air-cooled ammonia–water absorption refrigeration system could make good use of low-grade solar thermal energy to produce cooling effect. The system simulation results show that thermal COP is 0.34 and electrical COP is 26 under a typical summer condition with 85 °C hot water supplied from solar collector. System performances under variable working conditions are also analyzed. Circular finned tube bundles are selected to build the air-cooled equipment. The condenser should be arranged in the front to get an optimum system performance. The mathematical model of the two-stage air-cooled absorber considering simultaneous heat and mass transfer processes is developed. Low pressure absorber should be arranged in front of middle pressure absorber to minimize the absorption length. Configuration of the air-cooled equipment is suggested for a 5 kW cooling capacity system. Temperature and concentration profiles along the finned tube length show that mass transfer resistance mainly exists in liquid phase while heat transfer resistance mainly exists in cooling air side. The impacts on system refrigeration capacities related to absorption behaviors under variable working conditions are also investigated. Both cycle analysis and absorption performances show that two-stage air-cooled ammonia–water absorption chiller is technically feasible in practical solar cooling applications.  相似文献   

3.
The present study undertakes an exergy analysis of earth to air heat exchanger (EAHE) and applies to a local one in Turkey. Namely, the exergy performance of an EAHE has been evaluated in a demonstration in Solar Energy Institute of Ege University, Izmir, Turkey. Exergetic efficiencies of the system components are determined as an attempt to assess their individual performances. The daily maximum heating coefficient of performance (COP) value for the system is obtained to be 6.18. The total average COP in the experimental period is found to be 4.74.  相似文献   

4.
In this study energy, exergy and exergoeconomic analysis of the Afyon geothermal district heating system (AGDHS) in Afyon, Turkey is performed through thermodynamic performances and thermo-economic assessments. In the analysis, actual system data are used to assess the district heating system performance, energy and exergy efficiencies, exergy losses and loss cost rates. Energy and exergy losses throughout the AGDHS are quantified and illustrated in the flow diagram. The energy and exergy efficiencies of the overall system are found to be 37.59% and 47.54%, respectively. The largest exergy loss occurs in the heat exchangers with 14.59% and then in the reinjection wells with 14.09%. Besides, thermo-economic evaluations of the AGDHS are given in table. Energy and exergy loss rates for the AGDHS are estimated to be 5.36 kW/$ and 0.2  kW/$, respectively.  相似文献   

5.
This paper deals with the effects of the operating parameters on the cooling performance that can be applied for a transcritical CO2 automotive air conditioning system. The experimental conditions of the performance tests for a CO2 system and components such as a gas cooler and an evaporator were suggested to compare with the performance of each at the standardized test conditions. This research presents experimental results for the performance characteristics of a CO2 automotive air conditioning system with various operating conditions such as different gas cooler inlet pressures, compressor speeds and frontal air temperatures/flow rates passing through the evaporator and the gas cooler. Experimental results show that the cooling capacity was more than 4.9 kW and coefficient of performance (COP) was more than 2.4, at each optimum pressure of gas cooler inlet during idling condition. Also, the cooling capacity was about 7.5 kW and COP was about 1.7 at the optimum pressure of gas cooler inlet during driving condition when air inlet temperatures of gas cooler and evaporator were 45 °C and 35 °C, respectively. Therefore, we concluded that the automotive air conditioning system using CO2 refrigerant has good performance. This paper also deals with the development of optimum high pressure control algorithm for the transcritical CO2 cycle to achieve the maximum COP.  相似文献   

6.
In this study, the performance of a mobile heat pump for an electric bus, which uses the wasted heat of electric devices for a heating and air source for a cooling, was evaluated. Both cooling and heating performances of the mobile heat pump were tested under various experimental conditions, and then optimized by varying the refrigerant charge and the compressor frequency. The cooling capacity at all compressor frequencies was over 23.0 kW, which is sufficient for the cooling loads of an electric bus. The heating COP decreased but the heating capacity increased with the rise of outdoor temperature and the compressor frequency. The heating COP was 2.4 at an outdoor temperature of 10.0 °C. The observed heating and cooling performance characteristics of the mobile heat pump means it could be used for cabin heating and air conditioning of an electric vehicle with a short driving range.  相似文献   

7.
In evaluating the efficiency of heat pump (HP) systems, the most commonly used measure is the energy (or first law) efficiency, which is modified to a coefficient of performance (COP) for HP systems. However, for indicating the possibilities for thermodynamic improvement, energy analysis is inadequate and exergy analysis is needed. This study presents an exergetic assessment of a ground‐source (or geothermal) HP (GSHP) drying system. This system was designed, constructed and tested in the Solar Energy Institute of Ege University, Izmir, Turkey. The exergy destructions in each of the components of the overall system are determined for average values of experimentally measured parameters. Exergy efficiencies of the system components are determined to assess their performances and to elucidate potentials for improvement. COP values for the GSHP unit and overall GSHP drying system are found to range between 1.63–2.88 and 1.45–2.65, respectively, while corresponding exergy efficiency values on a product/fuel basis are found to be 21.1 and 15.5% at a dead state temperature of 27°C, respectively. Specific moisture extraction rate (SMER) on the system basis is obtained to be 0.122 kg kW?1 h?1. For drying systems, the so‐called specific moisture exergetic rate (SMExR), which is defined as the ratio of the moisture removed in kg to the exergy input in kW h, is also proposed by the authors. The SMExR of the whole GSHP drying system is found to be 5.11 kg kW?1 h?1. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

8.
In the present paper, an exergetic analysis of a double stage thermal compressor using the lithium bromide–water solution is performed. The double stage system considered allows obtaining evaporation temperatures equal to 5 °C using solar heat coming from flat plate collectors and other low grade thermal sources. In this study, ambient air and water are alternatively used as cooling fluids without crystallization problems up to condensation–absorption temperatures equal to 50 °C. The results obtained give the entropy generated, the exergy destroyed and the exergetic efficiency of the double stage thermal compressor as a function of the absorption temperature. The conclusions obtained show that the irreversibilities generated by the double stage thermal compressor will tend to increase with the absorption temperature up to 45 °C. The maximum value corresponds to 1.35 kJ kg−1 K−1. The entropy generated and the exergy destroyed by the air cooled system are higher than those by the water cooled one. The difference between the values increases when the absorption temperature increases. For an absorption temperature equal to 50 °C, the air cooled mode generates 14% more entropy and destroys 14% more exergy than the water cooled one. Also, the results are compared with those of previous studies for single and double effect air cooled and water cooled thermal compressors. The conclusions show that the double stage system has about 22% less exergetic efficiency than the single effect one and 32% less exergetic efficiency than the double effect one.  相似文献   

9.
This paper presents the cooling performance of a water-to-refrigerant type ground heat source heat pump system (GSHP) installed in a school building in Korea. The evaluation of the cooling performance has been conducted under the actual operation of GSHP system in the summer of year 2007. Ten heat pump units with the capacity of 10 HP each were installed in the building. Also, a closed vertical typed-ground heat exchanger with 24 boreholes of 175 m in depth was constructed for the GSHP system. To analyze the cooling performance of the GSHP system, we monitored various operating conditions, including the outdoor temperature, the ground temperature, and the water temperature of inlet and outlet of the ground heat exchanger. Simultaneously, the cooling capacity and the input power were evaluated to determine the cooling performance of the GSHP system. The average cooling coefficient of performance (COP) and overall COP of the GSHP system were found to be ~8.3 and ~5.9 at 65% partial load condition, respectively. While the air source heat pump (ASHP) system, which has the same capacity with the GSHP system, was found to have the average COP of ~3.9 and overall COP of ~3.4, implying that the GSHP system is more efficient than the ASHP system due to its lower temperature of condenser.  相似文献   

10.
The energy and exergy analyses of the drying process of olive mill wastewater (OMW) using an indirect type natural convection solar dryer are presented. Olive mill wastewater gets sufficiently dried at temperatures between 34 °C and 52 °C. During the experimental process, air relative humidity did not exceed 58%, and solar radiation ranged from 227 W/m2 to 825 W/m2. Drying air mass flow was maintained within the interval 0.036–0.042 kg/s. Under these experimental conditions, 2 days were needed to reduce the moisture content to approximately one-third of the original value, in particular from 3.153 gwater/gdry matter down to 1.000 gwater/gdry matter.Using the first law of thermodynamics, energy analysis was carried out to estimate the amounts of energy gained from solar air heater and the ratio of energy utilization of the drying chamber. Also, applying the second law, exergy analysis was developed to determine the type and magnitude of exergy losses during the solar drying process. It was found that exergy losses took place mainly during the second day, when the available energy was less used. The exergy losses varied from 0 kJ/kg to 0.125 kJ/kg for the first day, and between 0 kJ/kg and 0.168 kJ/kg for the second. The exergetic efficiencies of the drying chamber decreased as inlet temperature was increased, provided that exergy losses became more significant. In particular, they ranged from 53.24% to 100% during the first day, and from 34.40% to 100% during the second.  相似文献   

11.
In this study, the first and second law of thermodynamics are used to analyze the performance of a novel absorption system for cooling and heating applications. The active component of the sorbent used in this study is sodium thiocyanate (NaSCN). Ammonia (NH3) is chosen as sorptive. A mathematic model based on exergy analysis is introduced to analyze the system performance. Enthalpy, entropy, temperature, mass flow rate and exergy loss of each component and the total exergy loss of the system are evaluated. Furthermore, the coefficient of performance (COP) and exergetic efficiency of the absorption system for cooling and heating processes are calculated from the thermodynamic properties of the working fluids under different operating conditions. The results show that the COP of cooling and heating increases with the heat source temperature and decreases with the cooling water inlet temperature, but the system exergetic efficiency does not show the same trends for both cooling and heating applications. The simulation results can be used for the thermodynamic optimization of the current system.  相似文献   

12.
The present study undertakes an exergy and reliability analysis of wind turbine systems and applies to a local one in Turkey: the exergy performance and reliability of the small wind turbine generator have been evaluated in a demonstration (1.5 kW) in Solar Energy Institute of Ege University (latitude 38.24 N, longitude 27.50 E), Izmir, Turkey. In order to extract the maximum possible power, it is important that the blades of small wind turbines start rotating at the lowest possible wind speed. The starting performance of a three-bladed, 3 m diameter horizontal axis wind turbine was measured in field tests. The average technical availability, real availability, capacity factor and exergy efficiency value have been analyzed from September 2002 to November 2003 and they are found to be 94.20%, 51.67%, 11.58%, and 0–48.72%, respectively. The reliability analysis has also been done for the small wind turbine generator. The failure rate is high to an extent of 2.28×10−4 h−1 and the factor of reliability is found to be 0.37 at 4380 h. If failure rate can be decreased, not only this system but also other wind turbine systems of real availability, capacity factor and exergy efficiency will be improved.  相似文献   

13.
This paper presents an experimental investigation of a direct expansion air conditioner working with R407C as an R22 alternative. Experiments are conducted on a vapor compression refrigeration system using air as a secondary fluid through both the evaporator and the condenser. The influences of the evaporator air inlet temperature (20–32 °C), the evaporator air flow rate (250–700 m3/h) and the evaporator air humidity ratio (9 and 14.5 gwv/kga) at the condenser air temperature and volume flow rate of 35 °C and 850 m3/h, respectively on the system performance are investigated. Experimental results revealed that the evaporator air inlet temperature has pronounced effects on the air exit temperatures, pressures of the evaporator and the condenser, cooling capacity, condenser heat load, compressor pressure ratio and the COP of both refrigerants at humidity ratios of 9 and 14.5 gwv/kga. Significant effects of the evaporator air flow rate are also gathered on the preceding parameters at the same values of mentioned-humidity ratios. The best performance, in terms of operating parameters as well as COP, can be accomplished using R22 compared to R407C. The inlet humidity ratio affects dramatically the performance of vapor compression system using R22 and R407C. The raising up humidity ratio from 9 to 14.5 gwv/kga leads to an augmentation in the average cooling capacity by 29.4% and 38.5% and an enhancement in the average COP by 30% and 24.1% for R22 and R407C, respectively.  相似文献   

14.
In this paper, the GAX and GAX hybrid absorption refrigeration cycles are studied and compared from the viewpoint of both first and second law of thermodynamics. Exergy analyses were performed in order to calculate the total exergy destruction rate within the cycles and also reveal the contribution of different components to the destructions. In order to evaluate the efficiencies of the cycles at different working conditions, particularly from the viewpoint of the second law, parametric studies were also performed. It was found that in both cycles the generator temperature (Tgen) has more influence on the second law efficiency whereas, the coefficient of performance (COP) of the cycles are comparatively less affected by this temperature. An increase of about 75% in the second law efficiency of the GAX cycle was found as the generator temperature was varied from 400 to 440 K. With this variation of the generator temperature, the increase in the corresponding COP was around 5%. In addition, compared to that in the GAX cycle, the maximum value of exergetic efficiency in the GAX hybrid cycle occurs at a slightly higher value of Tgen.  相似文献   

15.
This article presents the dynamic modelling of a single effect two-bed adsorption chiller utilizing the composite adsorbent “CaCl2 confined to KSK silica gel” as adsorbent and water as adsorbate, which is based on the experimentally confirmed adsorption isotherms and kinetics data. Compared with the experimental data of conventional adsorption chiller based on RD silica gel + water pair, we found that the new working pair provides better cooling capacity and performances. From numerical simulation, it is also found that the cooling capacity can be increased up to 20% of the parent silica gel + water adsorption chiller and the coefficient of performance (COP) can be improved up to 25% at optimum conditions. We also demonstrate here that the best peak chilled water temperature suppression, and the maximum cooling capacity can be achieved by the optimum analysis for both cycles.  相似文献   

16.
In this paper, a solar-powered compound system for heating and cooling was designed and constructed in a golf course in Taiwan. An integrated, two-bed, closed-type adsorption chiller was developed in the Industrial Technology Research Institute in Taiwan. Plate fin and tube heat exchangers were adopted as an adsorber and evaporator/condenser. Some test runs have been conducted in the laboratory. Under the test conditions of 80 °C hot water, 30 °C cooling water, and 14 °C chilled water inlet temperatures, a cooling power of 9 kW and a COP (coefficient of performance for cooling) of 0.37 can be achieved. It has provided a SCP (specific cooling power) of about 72 W/(kg adsorbent). Some field tests have been performed from July to October 2006 for providing air-conditioning and hot water. The efficiency of the collector field lies in 18.5–32.4%, with an average value of 27.3%. The daily average COP of the adsorption chiller lies in 33.8–49.7%, with an average COP of 40.3% and an average cooling power of 7.79 kW. A typical daily operation shows that the efficiency of the solar heating system, the adsorption cooling and the entirely solar cooling system is 28.4%, 45.2%, and 12.8%, respectively.  相似文献   

17.
This paper presents the main characteristics of an innovative cooling system for the air conditioning of a truck cabin, as well as a first estimation of its performance during a standard driving cycle, obtained with a specifically developed vehicle-engine-cooling system overall model. The innovative cooling system consists of a water–zeolite adsorption–desorption system, which employs the waste heat from the engine to produce the cooling of the vehicle cabin. The developed global model is completely dynamic and is able to: reproduce the operation of the engine through a standard driving cycle, evaluate the waste heat available at the engine hydraulic loop; calculate the sequential operation of an adsorption–desorption system, calculate the condensed water per cycle, the cooling effect produced at the evaporator, and finally, the temperature and humidity evolution of the air inside the cabin. The model was validated by experimental data. The experimental tests were performed in a lab-scale adsorption chiller prototype specifically designed and realized to be driven by the low grade waste heat (80–90 °C) from the engine coolant loop of a truck. The experimental activity carried out showed that the chiller is able to generate up to 5 kW of peak cooling power at 10 °C (35 °C of condensation temperature) with a COP of 0.6. The obtained results show that the system could be able to provide a significant amount of the required cooling.  相似文献   

18.
In this study heat pump systems having different heat sources were investigated experimentally. Solar‐assisted heat pump (SAHP), ground source heat pump (GSHP) and air source heat pump (ASHP) systems for domestic heating were tested. Additionally, their combination systems, such as solar‐assisted‐ground source heat pump (SAGSHP), solar‐assisted‐air source heat pump (SAASHP) and ground–air source heat pump (GSASHP) were tested. All the heat pump systems were designed and constructed in a test room with 60 m2 floor area in Firat University, Elazig (38.41°N, 39.14°E), Turkey. In evaluating the efficiency of heat pump systems, the most commonly used measure is the energy or the first law efficiency, which is modified to a coefficient of performance for heat pump systems. However, for indicating the possibilities for thermodynamic improvement, inadequate energy analysis and exergy analysis are needed. This study presents an exergetic evaluation of SAHP, GSHP and ASHP and their combination systems. The exergy losses in each of the components of the heat pump systems are determined for average values of experimentally measured parameters. Exergy efficiency in each of the components of the heat pump systems is also determined to assess their performances. The coefficient of performance (COP) of the SAHP, GSHP and ASHP were obtained as 2.95, 2.44 and 2.33, whereas the exergy losses of the refrigerant subsystems were found to be 1.342, 1.705 and 1.942 kW, respectively. The COP of SAGSHP, SAASHP and GSASHP as multiple source heat pump systems were also determined to be 3.36, 2.90 and 2.14, whereas the exergy losses of the refrigerant subsystems were approximately 2.13, 2.996 and 3.113 kW, respectively. In addition, multiple source heat pump systems were compared with single source heat pump systems on the basis of the COP. Exergetic performance coefficient (EPC) is introduced and is applied to the heat pump systems having various heat sources. The results imply that the functional forms of the EPC and first law efficiency are different. Results show that Exloss,total becomes a minimum value when EPC has a maximum value. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

19.
In the modern agriculture, greenhouses are well established as technological solutions aimed to increase plants productivity and crops quality. Greenhouses can include added capabilities for the energy generation by the integration of photovoltaic solar modules in their cladding areas provided that the blocking effect of photosynthetically active radiation is not significant for plants growing. After a comprehensive literature survey on the integration of photovoltaic systems in greenhouses, this work describes the results of an experience carried out at Almería (South Eastern Spain), where it has been built and monitored a 1.024 m2 pilot photovoltaic greenhouse. The experimental set up has consisted of a greenhouse roof 9.79% coverage ratio by means of 24 flexible thin film modules, installed in two different checkerboard configurations. The obtained results indicate that, for the conditions of the undertaken experiment, the yearly electricity production normalised to the greenhouse ground surface is 8.25 kW h m?2, concordant to previous findings for the used type of modules. In addition to this, an artificial neural network model has been elaborated to predict the electricity instantaneous production of the system, showing the suitability of this modelling technique for complex and non linear systems, as it is the case of the constructively integrated PV plants, either in greenhouses and buildings, where both impinging radiation and system configuration are highly constrained by the pre-existing structures.  相似文献   

20.
The insensitivity to energy quality is one of the disadvantages of an energy analysis when compared to an exergy analysis. It is only the exergy analysis that clearly reveals the degradation of energy quality in the processes of absorption and emission of solar radiation. The national spatial distribution of mean monthly exergy values of solar radiation over Turkey was mapped at 500-m resolution using universal kriging based on solar radiation data from 152 geo-referenced locations. Mean exergy value of solar radiation in Turkey was estimated at 13.5 ± 1.74MJm?2day?1, with a mean annual exergy-to-energy ratio of 0.93.  相似文献   