首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 14 毫秒
1.
This paper investigates the elastic modulus and hardness of untreated and treated compression-moulded ultra-high molecular weight polyethylene (UHMWPE) tibial inserts of a total knee replacement (TKR) prosthesis. Investigations were carried out at a nanoscale using a Nanoindenter at penetration depths of 100,250 and 500 nm. The nanomechanical properties of surface and subsurface layers of the compression-moulded tibial inserts were studied using the untreated UHMWPE. The nanomechanical properties of intermediate and core layers of the compression-moulded tibial insert were studied using the cryoultrasectioned and etched UHMWPE treated samples. The cryoultrasectioning temperature (-150 degrees C) of the samples was below the glass transition temperature, Tg (-122 +/- 2 degrees C ), of UHMWPE. The measurement of the mechanical response of crystalline regions within the nanostructure of UHMWPE was accomplished by removing the amorphous regions using a time-varying permanganic-etching technique. The percentage crystallinity of UHMWPE was measured using differential scanning calorimetry (DSC) and the Tg of UHMWPE was determined by dynamic mechanical analysis (DMA). Atomic force microscopy (AFM) was used to assess the effect of surface preparation on the samples average surface roughness, Ra. In this study, it was demonstrated that the untreated UHMWPE samples had a significantly lower (p < 0.0001) elastic modulus and hardness relative to treated UHMWPE cryoultrasectioned and etched samples at all penetration depths. No significant difference (p > 0.05) in elastic modulus and hardness between the cryoultrasectioned and etched samples was observed. These results suggest that the surface nanomechanical response of an UHMWPE insert in a total joint replacement (TJR) prosthesis is significantly lower compared with the bulk of the material. Additionally, it was concluded that the nanomechanical response of material with higher percentage crystallinity (67 per cent) was predominantly determined by the crystalline regions within the semi-crystalline UHMWPE nanostructure.  相似文献   

2.
To estimate the true wear rate of polyethylene acetabular cups used in total hip arthroplasty, the dynamic compressive creep deformation of ultra-high molecular weight polyethylene (UHMWPE) was quantified as a function of time, load amplitude, and radial location of the specimen in the extruded rod stock. These data were also compared with the creep behavior of polyethylene observed under static loading. Total creep strains under dynamic loading were only 64%, 70%, and 61% of the total creep strains under static loading at the same maximum pressures of 2 MPa, 4 MPa, and 8 MPa, respectively. Specimens cut from the periphery of the rod stock demonstrated more creep than those cut from the center when they were compressed in a direction parallel to the extrusion direction (vertical loading), whereas the opposite was observed when specimens were compressed in a direction perpendicular to the extrusion direction (transverse loading). These findings show that creep deformation of UHMWPE depends upon the orientation of the crystalline lamellae.  相似文献   

3.
Ultra-high molecular weight polyethylene (UHMWPE) provides a low friction, high toughness interface in artificial knees and hips. Micron-sized wear debris forms over time in these transplants leading to osteolysis and poor clinical outcomes. Using the atomic force microscope (AFM) as a model single asperity contact, tribological studies were performed on nanometer smooth samples of UHMWPE under dry conditions to elucidate the mechanisms of debris formation. Low loads produced no changes in friction or topography despite repeated scanning. Above a critical load, polymer accumulated at the perimeter of the scan and led to the formation of a wear debris particle. Plastically deformed material exhibited a surprisingly high friction compared to surrounding pristine areas, and may partially explain macroscale observations of adhesive wear. In contrast, the polymer in the interior of the scanned area exhibited a friction identical to pristine polymer. These data link strain-softening and delamination of the surface to the formation of wear debris.  相似文献   

4.
The paper reviews publications, primarily of the Institute of Machinery Science of the Russian Academy of Sciences. The techniques of investigations and the results are briefly outlined as to how various high-melting point materials withstand friction in vacuum and in gaseous atmospheres (within a wide temperature range) in like or unlike combinations, such as metals, metal-like compounds, oxides, graphite materials and molybdenum disulphide. The results of measurements of adhesion, including that between diamond and various metals, are given. The friction drop of graphite material on corundum ceramics caused abnormally by tribochemical interaction, is described. The ‘eutectic wear’ accompanied by a sharp friction reduction is based on an investigation of the phenomenon of eutectic melting of diamond and graphite with experimental validation. The results of studies of vacuum ion-plasma deposited Cr---O and MoS2 coatings are demonstrated and a technique is suggested as to how to make the friction of MoS2 very low.  相似文献   

5.
Solid-state deformation of UHMWPE used in total joint prosthesis could be a relevant treatment prior to cross-linking to obtain high strength. However, little is known about the influence of chain alignment (texture) on sliding wear behavior. In this work, we analyzed i) the deformation mechanisms of UHMWPE resulting from a uniaxial tension (elongation of about 300%) and ii) the influence of the texture on the friction behavior resulting from ball-on-flat sliding tests (reciprocating sliding mode). Microstructural investigations show that tension induces a transformation of the initial lamellar morphology into specific microfibrillar morphology. White light interferometer (WLI) studies show that texturing causes an increase of the roughness by a factor of about two. After 50,000 sliding cycles, the cumulative dissipated energy decreases from 109,300-103,600 μJ for untreated UHMWPE to 64,600 and 43,150 μJ for textured UHMWPE, parallel and perpendicular to the texture direction, respectively. Considering that wear resistance increases with decreasing dissipated energy, textured UHMWPE may have anti-wear properties. However, cracks are noted at microscopic scale for textured UHMWPE. Regarding wear resistance, such defects are not suitable and can be avoided by reducing the roughness of textured UHMWPE prior to wear tests.  相似文献   

6.
The friction and wear behavior of ultra-high molecular weight polyethylene (UHMWPE) sliding against bearing steel (AISI 52100) in a ring-on-block contact mode under the lubrication of aqueous solution of 3.5% NaCl was evaluated. The worn polymer surfaces were analyzed by means of three dimensional profiling, atomic force microscopy, Polarized Raman microanalysis, field emission scanning electron microscopy, and nanoindentation testing. It was found that unusual wavelike abrasion patterns were formed on the worn surface of UHMWPE under properly selected sliding conditions. In the presence of plowing effect, the molecular chains of UHMWPE and short-rod like microcrystalline grains of abrasion pattern were both further oriented along the plowing direction and became tiny and dense owing to microstructure reconstruction. Resultant microstructurally reconstructed worn surface of UHMWPE had a higher nanoindentation hardness and modulus as well as increased wear resistance.  相似文献   

7.
W. Shi  X. Y. Li  H. Dong   《Wear》2001,250(1-12):544-552
Surface modification of ultra-high molecular weight polyethylene (UHMWPE) has been explored using the novel non-line-of-slight plasma immersion ion implantation (PIII) with nitrogen. The modified surfaces were characterised by SEM and a Nano Test 600 testing machine. The tribological behaviour of PIII treated UHMWPE sliding against AISI 316L stainless steel counterfaces was evaluated using a pin-on-disc tribometer under water lubricated conditions. The experimental results show that PIII is a very promising surface engineering technique to improve such surface mechanical properties as surface hardness and elastic modulus of UHMWPE. As a result, the wear resistance of UHMWPE was significantly enhanced by a factor of three following PIII treatment, as compared with untreated material. It was found that the significantly improved wear resistance of PIII treated UHMWPE can be mainly attributed to ion bombardment induced cross-linking, and thus surface hardening.  相似文献   

8.
Medical-grade UHMWPE samples with two different surface finishing treatments, milling and melting/reforming were exposed to 10% bovine serum albumin solution and their friction responses were quantified using atomic force microscopy. The observed friction increase upon exposure to proteins was attributed to the formation of a layer of denatured proteins on the surface. Changing the crystallinity and surface energy of UHMWPE affected the protein adsorption mechanism and the resulting increase in friction behavior.  相似文献   

9.
One of the important design parameters in current knee joint replacements is the thickness of the ultra-high molecular weight polyethylene (UHMWPE) tibial insert, yet there is no clear definition of the upper limit of the 'thick' polyethylene insert. Using one design knee implant and subjecting it to the physiological loads encountered throughout the gait cycle, measurements of the lengths of contact imprints generated were compared with the corresponding theoretical predictions for different insert thicknesses under the same applied load. Multiple regression analysis was applied to test whether the dimensions of contact imprints are influenced by UHMWPE thickness. Good agreement was obtained between the theoretical predictions and the experimental measurements of the dimensions of contact imprints when the knee was at 60 degrees flexion. Therefore, it was possible to estimate the contact pressure at the articulating surface using the theoretical model. Contact imprint dimensions increased with increasing applied load. Statistical analysis of the experimental data revealed that, at 0 degree flexion, the overall imprint dimensions increased as the UHMWPE thickness increased from 8 to 20 mm. However, the increment was not significant when the thickness subinterval 10-15 mm was considered. Furthermore, at 60 degrees flexion, thickness was not a significant factor for the overall imprint dimensions. No evidence was found from the data to suggest that an increment in polyethylene thickness over 10 mm would significantly reduce the contact imprint dimensions. These findings suggest that thicker inserts can be avoided, as they require unnecessary bone resection.  相似文献   

10.
Elastohydrodynamic lubrication was analysed under squeeze-film or normal approach motion for artificial hip joint replacements consisting of an ultra-high molecular weight polyethylene (UHMWPE) acetabular cup and a metallic or ceramic femoral head. A simple ball-in-socket configuration was adopted to represent the hip prosthesis for the lubrication analysis. Both the Reynolds equation and the elasticity equations were solved simultaneously for the lubricant film thickness and hydrodynamic pressure distribution as a function of the squeeze-film time was solved using the Newton-Raphson method. The elastic deformation of the UHMWPE cup was calculated by both the finite element method and a simple equation based upon the constrained column model. Good agreement of the predicted film thickness and pressure distribution was found between these two methods. A simple analytical method based upon the Grubin-Ertel-type approximation developed by Higginson in 1978 [1] was also applied to the present squeeze-film lubrication problem. The predicted squeeze-film thickness from this simple method was found to be remarkably close to that from the full numerical solution. The main design parameters were the femoral head radius, the radial clearance between the femoral head and the acetabular cup, and the thickness and elastic modulus for the UHMWPE cup; the effects of these parameters on the squeeze-film thickness generated in current hip prostheses were investigated.  相似文献   

11.
A fully coupled contact and wear model was developed in the present study for hip implants employing an ultra-high molecular weight polyethylene (UHMWPE) cup in combination with a metallic or ceramic femoral head. A simple elasticity equation based on the concept of constrained column model was employed to solve the contact mechanics between the acetabular cup and the femoral head under the three-dimensional physiological loading condition. The wear model was based on the classical Archard-Lancaster equation in common with all other studies reported in the literature. The fully coupled contact and wear model was applied to both conventional and cross-linked UHMWPE cups under a wide range of design parameters such as the clearance and the femoral head radius. The predicted linear and volumetric wear as well as their rates for conventional UHMWPE cups were found to be in good agreement with those obtained from a similar analysis by Maxian but using the finite element method for the contact mechanics analysis. The predicted maximum contact pressure was found to decrease rapidly within the first 10(6) cycles, and below the limit to cause plastic deformation within the UHMWPE cup with a nominal radial clearance of 0.2 mm. The effect of the clearance between the head and the cup on the predicted wear was found to be negligible. For the cross-linked UHMWPE cup with relatively large diameters up to 48 mm and a fixed outside diameter of 50 mm, the predicted wear, which was found to increase with increasing femoral head radius, remained small owing to the small wear factor associated with these materials. Furthermore, if the head diameter increases beyond 42 mm, a rapid increase in the contact pressure was predicted, owing to the decrease in the wall thickness of the cross-linked UHMWPE cup.  相似文献   

12.
Computational wear models need input data from valid tribological tests. For the wear model of a total hip prosthesis, the contact pressure dependence of wear and friction of ultra-high molecular weight polyethylene (UHMWPE) against polished CoCr in diluted calf serum lubricant was studied, and useful input data produced. Two test devices were designed and built: a heavy load circularly translating pin-on-disc (HL-CTPOD) wear test device and an HL-CTPOD friction measurement device. Both can be used with a wide range of loads. The wear surface diameter of the test pin was kept constant at 9 mm, whereas the load was varied so that the nominal contact pressure ranged from 0.1 to 20 MPa. The wear factor decreased with increasing contact pressure, whereas the coefficient of friction first increased with increasing contact pressure with low pressure values and then decreased. Up to the pressure of 2.0 MPa, the wear mechanisms and wear factors were in good agreement with clinical findings. In the critical range of 2.0-3.5 MPa, the wear mechanisms and wear factors started to differ from clinical ones, and the decrease of the wear factor steepened. The discrepancy became more and more evident as the pressure was gradually increased beyond 3.5 MPa. It appears that the pressure value of 2.0 MPa should not be exceeded in pin-on-disc wear tests that are to reproduce the clinical wear of UHMWPE acetabular cups.  相似文献   

13.
Ultra-high molecular weight polyethylene (UHMWPE) is a common bearing component in total knee replacement (TKR) implants, and its susceptibility to wear continues to be the long-term limiting factor in the life of these implants. This study hypothesized that in TKR systems, a highly cross-linked (HXL) UHMWPE blended with vitamin E will result in reduced wear as compared to a direct compression-moulded (DCM) UHMWPE. A wear simulation study was conducted using an asymmetric lateral pivoting '3D Knee' design to compare the two inserts. The highly cross-linked UHMWPE was aged prior to the testing and force-controlled wear testing was carried out for 5 million cycles using a load-controlled ISO-14243 standard at a frequency of 1 Hz on both groups. Gravimetric measurements of DCM UHMWPE (4.4 +/- 3.0 mg/million cycles) and HXL UHMWPE with vitamin E (1.9 +/- 1.9 mg/million cycles) showed significant statistical differences (p < 0.01) between the wear rates. Wear modes and surface roughness for both groups revealed no significant dissimilarities.  相似文献   

14.
A loading protocol approximating forces, torques and motions at the knee during stair descent was developed from previously published data for input into a force-controlled knee simulator. A set of total knee replacements (TKRs) was subjected to standard walking cycles and stair descent cycles at a ratio of 70: 1 for 5 million cycles. Another set of implants with similar articular geometry and the same ultra-high molecular weight polyethylene (UHMWPE) resin (GUR 415), sterilization and packaging was tested with standard walking cycles only. Implant kinematics, gravimetric wear and surface roughness of the UHMWPE inserts were analysed for both sets of implants. Contact stresses were calculated for both loading protocols using a Hertzian line contact model. Significantly greater weight loss (p < 0.05) and more severe surface damage of UHMWPE inserts resulted with the walking + stair descent loading protocol compared to walking cycles only. Anterior-posterior (AP) tibiofemoral contact point displacements were lower during stair descent than walking, but not significantly different (p = 0.05). Contact stresses were significantly higher during stair descent than walking, owing to higher axial loads and the smaller radius of curvature of the femoral components at higher flexion angles. High contact stresses on UHMWPE components are likely to accelerate the fatigue of the material, resulting in more severe wear, similar to what is observed in retrieved implants. Thus the inclusion of loading protocols for activities of daily living in addition to walking is warranted for more realistic in vitro testing of TKRs.  相似文献   

15.
The weight gain due to fluid absorption was measured in gamma-sterilized, ethylene oxide (ETO) gas-sterilized, and unsterilized ultra-high molecular weight (UHMW) polyethylene acetabular cups. After about 2 months the total average fluid absorption gain of the polyethylene cups was: 1.76 +/- 0.45 mg (average +/- standard deviation) for the unsterilized polyethylene cups, 2.81 +/- 0.95 mg for the gamma-sterilized polyethylene cups and 1.51 +/- 0.34 for the ETO gas-sterilized polyethylene cups. There was little difference in fluid absorption between the sterilized and unsterilized specimens. In particular, the gamma-sterilized acetabular cups absorbed more than the ETO gas-sterilized and the unsterilized cups. However, the weight gain was higher in serum compared with that in water.  相似文献   

16.
Ultrahigh molecular weight polyethylene (UHMWPE) fatigue is a critical factor affecting the longevity of total knee replacement (TKR) bearings. With the increased need for laboratory studies to mimic near in vivo conditions for accurate characterization of material performance, the present study investigated the role of hyaluronic acid (HA) in testing lubricant on the crack growth response of UHMWPE. It was hypothesized that the change in lubricant viscosity as a result of HA would affect the fatigue life of the polymer. A fracture mechanics approach as per ASTM E 647 was adopted for this study. Surface micrograph and surface chemistry analyses were employed to study the micromechanisms of fatigue failure and protein adsorption of the specimen surfaces. Rheological analysis indicated that the addition of HA to diluted bovine serum increased testing lubricant viscosity. HA concentrations of 2.22, 0.55, and 1.5 g/l closely matched the viscosity ranges reported for osteoarthritis, rheumatoid arthritic diseased joint fluid, and periprosthetic fluids respectively. Results showed that the addition of HA to standard diluted bovine serum lubricants, in concentrations similar to that of periprosthetic fluid, delayed crack initiation and crack growth during fatigue testing.  相似文献   

17.
This paper studies the effect of contact stress on friction and wear of ultra-high molecular weight polyethylene (UHMWPE) acetabular cups by means of friction and wear joint simulator testing under serum lubrication. For a given applied load, increasing the contact stress by increasing the ball/socket radial clearance decreased both the coefficient of friction and the wear rate. Friction and wear were highly correlated. The dependence of friction on contact stress for the UHMWPE socket under serum lubrication was similar to that of semi-crystalline polymers under dry sliding. This finding indicates the occurrence of partial dry contact at asperity levels for the metal-polyethylene ball-in-socket joint under serum lubrication.  相似文献   

18.
In this study, osteoarthritic and periprosthetic synovial fluid samples were rheologically and biochemically compared to develop a hyaluronic acid (HA) supplemented bovine serum (BS) lubricant that mimicked the properties of human joint synovial fluid. The effect of this BS + HA lubricant (50 per cent bovine calf serum + 1.5 g/l HA) on the wear rate of ultra-high molecular weight polyethylene (UHMWPE) during a total knee replacement wear test was then investigated. In conjunction with biochemical similarities, the rheological analysis showed that the BS + HA lubricant viscosity was not statistically different to aspirated total knee arthroplasty (TKA) revision joint fluid viscosity over a range of physiologic shear rates. Gravimetric results at 5 million wear testing cycles showed that the BS + HA lubricant produced an average of 6.88 times more UHMWPE wear than 50 per cent bovine serum lubricant alone. The BS + HA lubricated CoCr femoral component surfaces revealed pitting and surface roughening that was not observed using standard bovine serum only lubricants, but that was similar to the metallic surface corrosion observed on in vivo CoCr femoral component retrievals. These findings support the hypothesis that the addition of HA to simulator lubricant is capable of producing CoCr femoral component surface damage similar to that observed in vivo.  相似文献   

19.
The study was initiated to assess the suitability of Ti-6Al-4V as a metal which articulates against Ultra High Molecular Weight (UHMW) polyethylene in total joint applications. The wear surfaces of Ti alloy were prepared to different levels of surface roughness and the effect of various surface chemical treatments were examined. A specially designed annular contact laboratory wear tester was developed to provide the surface loading and articulation. Comparative tests were also performed using 316 LVM stainless steel and Co-Cr-Mo alloy metallic wear components. All annular contact wear tests were performed in mammalian Ringer's solution environments and were evaluated using standard statistical techniques. Scanning electron microscope (SEM) analysis of the wear surfaces indicates the formation of a polyethylene transfer film on all metal surfaces. The surface of the UHMW polyethylene samples after testing was considerably rougher than the original articulating metallic surface; the transfer film on the metal surfaces was responsible for this. It was concluded that Ti-6Al-4V is satisfactory for total joint replacement when used in combination with UHMW polyethylene. Proper surface preparation may allow lower rates of wear than conventional orthopaedic alloys.  相似文献   

20.
In order to predict the frictional heating and the contact stresses between the polyethylene cup and the metallic ball-head forming the articulation of a hip prosthesis a three-dimensional finite element model was developed and calculated. The non-linear model includes a fully coupled thermomechanical formulation of the mechanical properties of the ultra-high-molecular-weight polyethylene, and a large-sliding Coulomb frictional contact between the two components. The model predicts the temperature of the polyethylene with an accuracy that was tested by comparing the model predictions with the temperature measurements. The temperature measurements were taken by thermocouples placed on the cup surface, the head surface and the inside of the thermostatic bath, during a complete test within a hip joint wear simulator. The model was found to be very accurate, predicting the measured temperatures with an accuracy better than 2 per cent. The temperature peak (51 degrees C) was predicted at the contact surface. The model results indicate that frictional heat is mostly dissipated through the metallic ball-head. The full coupling between the thermal and the mechanical conditions used in this study appears to be necessary if accurate predictions of the polyethylene deformation are required.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号