首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Wang Q  Wang M  Li S  Xing X  Liu X  Dong S  Cai J 《Scanning》2012,34(1):60-67
B‐lymphocyte activation plays an important role in humoral immune system, and its process has been studied well in vivo and in vitro. However, the ultrastructure and adhesion property changes remain unclear. In this study, changes in the morphology and mechanical properties of human peripheral blood B lymphocytes were first studied by atomic force microscopy (AFM). B lymphocytes were treated with the mitogen, pokeweed mitogen (PWM), and Staphylococcus aureus Cowan strain I (SAC) for 24 hr. After B lymphocyte is stimulated by the mitogen, the cell height, diameter, and volume are changed in different degree. The ultrastructure of the B lymphocytes membrane obviously displayed proteins gathering, corresponding with larger changes of average roughness and mean height of particles on cell membrane. Meanwhile, we detected the adhesion force of B lymphocytes after being stimulated by PWM and SAC. We found that the treated cells had a higher adhesion force of 304.16 ± 60.30 pN (PWM) and 249.63 ± 58.03 pN (SAC) than that of control group (104.28 ± 21.77 pN). Therefore, our results could provide new information to further understand the B‐lymphocyte activation process and their structure‐function analyses. SCANNING 34: 60–67, 2012. © 2011 Wiley Periodicals, Inc.  相似文献   

2.
The poor integration with host cornea tissue and the low mechanical properties of pHEMA hydrogel for artificial cornea remains a difficult problem to solve. A modified pHEMA hydrogel, MMA copolymerized and type‐I collagen and bFGF immobilized, was previously prepared in an attempt to solve the problems. In this study, the cytotoxicity of Col/bFGF‐p (HEMA‐MMA) and p (HEMA‐MMA) was studied by cell adhesion assay and atomic force microscopy (AFM). The results of cell adhesion assay show that the attachment of keratocytes on the modified membrane is much higher than that of the unmodified membrane. This indicates that the material after modification have better cell–material interaction. The AFM images reveal that the morphology of keratocytes cultured on different substrate is obviously different. The cell cultured on modified membrane presented a completely elongated and spindle‐shape morphology. The force?distance indicates that the biomechanical of keratocytes changes significantly after culturing on different substrates. The adhesion force (2328±523 pN) and Young's modulus (0.51±0.125 kPa) of the cell cultured on modified membrane are much higher, and the stiffness (0.08±0.022 mN/m) is lower than those of the cell cultured on unmodified membrane. These results show that the cytotoxicity of Col/bFGF‐p (HEMA‐MMA) for keratocytes is much improved. SCANNING 31: 246–252, 2009. © 2010 Wiley Periodicals, Inc.  相似文献   

3.
目的:探讨原子力显微镜(AFM)在研究人脐静脉内皮细胞(ECV304)表面形貌、超微结构及纳米机械性质等方面的应用,讨论ECV304超微结构和机械性质与其功能的关系。方法:利用AFM对ECV304细胞的表面形貌及生物机械性质进行表征与测量。结果:在AFM下观察到用普通光学显微镜难以观察到的ECV304细胞的独特的形态结构,如细胞骨架、伪足及细胞边缘微丝等。ECV304细胞呈现长梭形、多角形、圆形等多种形态,细胞表面平均粗糙度为320.52±75.98 nm,表面均匀分布微绒毛,细胞周围有铺展的圆盘状物质。力曲线定量分析得出针尖与细胞表面的非特异性粘附力为75±14 pN。结论:通过AFM成像和力曲线测量表明,ECV304细胞呈圆形,多角形,梭形等多种形态,针尖与细胞膜表面问的粘附力比较小,约75±14pN。  相似文献   

4.
Changhong Ke  Hua Jin  Jiye Cai 《Scanning》2013,35(5):316-326
Integrin‐mediated human umbilical vein endothelial cells (HUVECs) adhesion to the extracellular matrix plays a fundamental role in tumor‐induced angiogenesis. Celastrol, a traditional Chinese medicine plant, has possessed anticancer and suppressed angiogenesis activities. Here, the mechanism underling the antiangiogenesis capacity of celastrol was investigated by exploring the effect of celastrol on β1(CD29) integrin‐mediated cell adhesion and migration. Flow cytometry results showed that the HUVECs highly expressed CD29 and cell adhesion assay indicated that celastrol specifically inhibited the adhesion of HUVECs to fibronectin (FN) without affecting nonspecific adhesion to poly‐L‐lysine (PLL). After cell FN adhesion being inhibited, the cell surface nanoscale structure and adhesion force were detected by atomic force microscope (AFM). High‐resolution imaging revealed that cell morphology and ultrastructure changed a lot after being treated with celastrol. The membrane average roughness (Ra) and the major forces were decreased from 31.34 ± 4.56 nm, 519.60 ± 82.86 pN of 0 μg/ml celastrol to 18.47 ± 6.53 nm, 417.79 ± 53.35 pN of 4.0 μg/ml celastrol, 10.54 ± 2.85 nm, 258.95 ± 38.98 pN of 8.0 μg/ml celastrol, respectively. Accompanying with the decrease of adhesion force, the actin cytoskeleton in the cells was obviously disturbed by the celastrol. All of these changes influenced the migration of HUVECs from the wound‐healing migration assay. Taken together, our results suggest that celastrol can be as an inhibitor of HUVEC adhesion to FN. This work provides a novel approach to inhibition of tumor angiogenesis and tumor growth. SCANNING 35:316‐326, 2013. © 2012 Wiley Periodicals, Inc.  相似文献   

5.
The integrity and adhesion properties of endothelium play vital roles during atherosclerosis. It is well known that oxidized low‐density lipoprotein (Ox‐LDL) influences many physiological activities or mechanical properties of endothelial cells. However, the effects of Ox‐LDL on the integrity and nonspecific adhesion properties of endothelial cells are still unclear. In this study, using the topographical imaging and force measurement functions of atomic force microscopy (AFM), we found that Ox‐LDL can transiently weaken the integrity of endothelium by impairing cell spreading of endothelial cells and decrease the attachment of irrelevant blood cells to endothelium by impairing the nonspecific adhesion property of endothelial cells. The AFM‐based data provide important information for understanding the effects of Ox‐LDL on endothelial cells or during atherogenesis. SCANNING 35: 119‐126, 2013. © 2012 Wiley Periodicals, Inc.  相似文献   

6.
A human hepatoma cell line (HepG2) was cultured on positively and negatively charged polyelectrolytes. Cell/surface adhesion and cell shape evolution were followed with quartz microbalance with dissipation (QCM‐D) and optical microscopy as a function of time, respectively. In particular, substrates coated with poly(ethyleneimine) (PEI) led to fast cell attachment and further spreading, with average maximum frequency Δf = 79 Hz and dissipation ΔD = 40 × 10?6. On the contrary, no cell spreading was observed on poly(sodium‐4‐styrenesulfonate) (PSS), with Δf = 33 Hz and ΔD = 4.5 × 10?6. Atomic force microscopy (AFM) was used to investigate the influence of cell shape on its mechanical properties. Considering the cells as an homogenous solid material, the corresponding elastic modulus was estimated using the Hertz model. The elastic modulus was calculated at the central part of the cell, and the average values obtained were 191 ± 14 Pa and 941 ± 58 Pa for cells adsorbed on PSS and PEI, respectively. Thus, different cell–substrate interaction implied different cell mechanical properties reflected in a higher elastic modulus for stronger cell/substrate interaction. The combination of QCM‐D, AFM, and optical microscopy allowed the online study of the cell adhesion process, and the mechanical properties of the adhered cells. Microsc. Res. Tech. 2009. © 2009 Wiley‐Liss, Inc.  相似文献   

7.
Atomic force microscopy (AFM) is today an established tool in imaging and determination of mechanical properties of biomaterials. Due to their complex organization, those materials show intricate properties such as viscoelasticity. Therefore, one has to consider that the loading rate at which the sample is probed will lead to different mechanical response (properties). In this work, we studied the dependence of the mechanical properties of endothelial cells on the loading rate using AFM in force spectroscopy mode. We employed a sharp, four‐sided pyramidal indenter and loading rates ranging from 0.5 to 20 μm/s. In addition, by variation of the load (applied forces from 100 to 10,000 pN), the dependence of the cell properties on indentation depth could be determined. We then showed that the mechanical response of endothelial cells depends nonlinearly on the loading rate and follows a weak power‐law. In addition, regions of different viscous response at varying indentation depth could be determined. Based on the results we obtained, a general route map for AFM users for design of cell mechanics experiments was described.  相似文献   

8.
The objective of this study is to investigate the effect of different Atomic Force Microscope (AFM) tip geometries (sharp-conical and spherical tips) on the microscale Young’s modulus of bovine articular cartilage and agarose gel that is calculated by the method of the average point-wise modulus. The measurements of the microscale Young’s moduli of 3% agarose gel under a conical AFM tip (20.9±4.9 kPa) and under a spherical AFM tip (17.5±3.0 kPa), averaged over an indentation depth of 600 nm, were comparable. However, the microscale Young’s moduli of articular cartilage, as measured with a conical AFM tip (116.9±62.9 kPa), were significantly higher than the corresponding values under a spherical AFM tip (30.9±14.3 kPa). The results of the current study suggest that the AFM tip geometry affects the microscale measurements of the mechanical properties on the surfaces of biological materials. The findings of the study can help to elucidate more accurately the microscale mechanical properties on the surface layers of diverse biological materials including tissue-engineered cartilages with different material characteristics.  相似文献   

9.
Atomic force microscopy (AFM) provides a new technology to visualize the cellular topography and quantify the molecular interactions at nanometer spatial resolution. In this work, AFM was used to image the cellular topography and measure the molecular force of pathological cells from B‐cell lymphoma patients. After the fluorescence staining, cancer cells were recognized by their special morphological features and then the detailed topography was visualized by AFM imaging. The AFM images showed that cancer cells were much rougher than healthy cells. CD20 is a surface marker of B cells and rituximab is a monoclonal antibody against CD20. To measure the CD20‐rituximab interaction forces, the polyethylene glycol (PEG) linker was used to link rituximab onto the AFM tip and the verification experiments of the functionalized probe indicated that rituximab molecules were successfully linked onto the AFM tip. The CD20‐rituximab interaction forces were measured on about 20 pathological cells and the force measurement results indicated the CD20‐rituximab binding forces were mainly in the range of 110–120 pN and 130–140 pN. These results can improve our understanding of the topography and molecular force of lymphoma pathological cells. SCANNING 35:40‐46, 2013. © 2012 Wiley Periodicals, Inc.  相似文献   

10.
Mechanical properties of a single cell are closely related to the fate and functions of the cell. Changes in mechanical properties may cause diseases or cell apoptosis. Selective cytotoxic effects of nonthermal atmospheric pressure micro‐dielectric barrier discharge (DBD) plasma have been demonstrated on cancer cells. In this work, changes in the mechanical properties of a single cell induced by nonthermal atmospheric pressure micro‐DBD plasma were investigated using atomic force microscopy (AFM). Two cervical cancer cell lines (HeLa and SiHa) and normal human fibroblast cells (HFBs) were exposed to micro‐DBD plasma for various exposure times. The elasticity of a single cell was determined by force–distance curve measurement using AFM. Young's modulus was decreased by plasma treatment for all cells. The Young's modulus of plasma‐treated HeLa cells was decreased by 75% compared to nontreated HeLa cells. In SiHa cells and HFBs, elasticity was decreased slightly. Chemical changes induced by the plasma treatment, which were observed by Raman spectroscopy, were also significant in HeLa cells compared to SiHa cells and HFBs. These results suggested that the molecular changes induced by micro‐DBD plasma were related to cell mechanical changes.  相似文献   

11.
In this study we have employed atomic force microscopy (AFM) and scanning near‐field optical microscopy (SNOM) techniques to study the effect of the interaction between human keratinocytes (HaCaT) and electromagnetic fields at low frequency. HaCaT cells were exposed to a sinusoidal magnetic field at a density of 50 Hz, 1 mT. AFM analysis revealed modification in shape and morphology in exposed cells with an increase in the areas of adhesion between cells. This latter finding was confirmed by SNOM indirect immunofluorescence analysis performed with a fluorescent antibody against the adhesion marker β4 integrin, which revealed an increase of β4 integrin segregation in the cell membrane of 50‐Hz exposed cells, suggesting that a higher percentage of these cells shows a modified pattern of this adhesion marker.  相似文献   

12.
Many DNA-based devices need to build stable and controllable DNA films on surfaces. However, the most commonly used method of film characterization, namely, the probe-like microscopes which may destroy the sample and substrate. Surface Forces Apparatus (SFA) technique, specializing in surface interaction studies, is introduced to investigate the effects of DNA concentration on the formation of single-stranded DNA (ss-DNA) film. The result demonstrates that 50 ng/μL is the lowest concentration that ss-DNA construct a dense layer on mica. Besides, it is also indicated that at different DNA concentrations, ss-DNA exhibit diverse morphology: lying flat on surface at 50 ng/μL while forming bilayer or cross-link at 100 ng/μL, and these ss-DNA structures are stable enough due to the repeatability even under the load of 15 mN/m. At the same time, an obvious adhesion force is measured: ?6.5 mN/m at 50 ng/μL and ?5.3 mN/m at 100 ng/μL, respectively, which is attributed to the ion-correlation effect. Moreover, the atomic force microscopy (AFM) images reveal the entire surface is covered with wormlike ss-DNA and the measured surface roughness (1.8±0.2 nm) also matches well with the film thickness by SFA. The desorption behaviors of ss-DNA layer from mica surface occur by adding sodium salt into gap buffer, which is mainly ascribed to the decreased ion-ion correlation force. This paper employing SFA and AFM techniques to characterize the DNA film with flexibility and stable mechanical ability achieved by ion bridging method, is helpful to fabricate the DNA-based devices in nanoscale.  相似文献   

13.
Planar patch-clamp force microscopy on living cells   总被引:2,自引:0,他引:2  
Here we report a new combination of the patch-clamp technique with the atomic force microscope (AFM). A planar patch-clamp chip microstructured from borosilicate glass was used as a support for mechanical probing of living cells. The setup not only allows for immobilizing even a non-adherent cell for measurements of its mechanical properties, but also for simultaneously measuring the electrophysiological properties of a single cell. As a proof of principle experiment we measured the voltage-induced membrane movement of HEK293 and Jurkat cells in the whole-cell voltage clamp configuration. The results of these measurements are in good agreement with previous studies. By using the planar patch-clamp chip for immobilization, the AFM not only can image non-adhering cells, but also gets easily access to an electrophysiologically controlled cellular probe at low vibrational noise.  相似文献   

14.
The atomic force microscope (AFM) has evolved from an imaging device into a multifunctional and powerful toolkit for probing the nanostructures and surface components on the exterior of bacterial cells. Currently, the area of application spans a broad range of interesting fields from materials sciences, in which AFM has been used to deposit patterns of thiol‐functionalized molecules onto gold substrates, to biological sciences, in which AFM has been employed to study the undesirable bacterial adhesion to implants and catheters or the essential bacterial adhesion to contaminated soil or aquifers. The unique attribute of AFM is the ability to image bacterial surface features, to measure interaction forces of functionalized probes with these features, and to manipulate these features, for example, by measuring elongation forces under physiological conditions and at high lateral resolution (<1 Å). The first imaging studies showed the morphology of various biomolecules followed by rapid progress in visualizing whole bacterial cells. The AFM technique gradually developed into a lab‐on‐a‐tip allowing more quantitative analysis of bacterial samples in aqueous liquids and non‐contact modes. Recently, force spectroscopy modes, such as chemical force microscopy, single‐cell force spectroscopy, and single‐molecule force spectroscopy, have been used to map the spatial arrangement of chemical groups and electrical charges on bacterial surfaces, to measure cell–cell interactions, and to stretch biomolecules. In this review, we present the fascinating options offered by the rapid advances in AFM with emphasizes on bacterial research and provide a background for the exciting research articles to follow. SCANNING 32: 74–96, 2010. © 2010 Wiley Periodicals, Inc.  相似文献   

15.
Atomic force microscopy has been used to visualize nano‐scale structures of various cellular components and to characterize mechanical properties of biomolecules. In spite of its ability to measure non‐fixed samples in liquid, the application of AFM for living cell manipulation has been hampered by the lack of knowledge of the mechanical properties of living cells. In this study, we successfully combine AFM imaging and force measurement to characterize the mechanical properties of the plasma membrane and the nuclear envelope of living HeLa cells in a culture medium. We examine cantilevers with different physical properties (spring constant, tip angle and length) to find out the one suitable for living cell imaging and manipulation. Our results of elasticity measurement revealed that both the plasma membrane and the nuclear envelope are soft enough to absorb a large deformation by the AFM probe. The penetrations of the plasma membrane and the nuclear envelope were possible when the probe indents the cell membranes far down close to a hard glass surface. These results provide useful information to the development of single‐cell manipulation techniques.  相似文献   

16.
Due to its extensive antitumor activity, curcumin has been focused on by more researchers. But, its antiproliferative mechanisms are still unknown. Here we studied the antiproliferative activity of curcumin in human liver cancer HepG2 cells. In order to analyze the cytotoxic activity and anticancer mechanisms of curcumin, we carried out cytotoxicity tests using 3‐[4,5‐dimethyl‐2‐thiazolyl]‐2,5 diphenyltetrazolium bromide (MTT) assay. The HepG2 cell cycle distribution and the expression of tubulin were detected by flow cytometry. Alterations in morphological and cytoskeletal properties of HepG2 cells were investigated using atomic force microscopy (AFM). Simultaneously, the effects of curcumin on the growth and proliferation of HepG2 cells were also assayed by MTT method. Cells were incubated with different doses of curcumin (0–80 μmol/l) for 24 h, the cell viability decreased from 91.10 ± 3.2% to 10.84 ± 4.0%, and the 50% inhibiting concentration (IC50) was 23.15 ± 0.37 μmol/l. Moreover, flow cytometry quantitatively detected that curcumin treatment resulted in a dose‐dependent accumulation of HepG2 cells in G2/M phase with concomitant losses from G0/G1 phase, so curcumin caused cell‐cycle arrest at G2/M phase. Furthermore, we discovered that curcumin was able to upregulate the expression of tubulin in HepG2 cells. In addition, AFM analysis including cell‐membrane structure and cytoskeleton networks is helpful to explain the relationship between the changes of cells and external pharmacologic stimulation. SCANNING 35: 253‐260, 2013. © 2012 Wiley Periodicals, Inc.  相似文献   

17.
Since the way that human bone cells behave on contact with different surfaces topographies seems to be crucial to osseointegration, the aim of the present study is to evaluate the participation of some micro‐ and nanosized features of Ti surfaces in the short‐term response of primary human osteoblast‐like cells (HOC). Surfaces were prepared as ground (G‐Ti), hydrofluoric acid etched (HF‐Ti), and sandblasted/HF‐etched (SLA‐Ti), and analyzed using both three‐dimensional (3D) profilometer and atomic force microscope (AFM). Cell morphology was assessed using scanning electron microscopy (SEM) after 4 and 24 h in culture. Cell viability, adhesion, and spreading were also evaluated 4 and 24 h after seeding over each surface. Data were compared by analysis of variance (ANOVA) complemented by Duncan test. Cell morphology, cell counting, and membrane integrity (Neutral Red, NR) were not affected by surface treatment at any time. However, HF‐Ti presented the smallest surface area and did not increase tetrazolium hydroxide (XTT) reduction from 4 to 24 h. On the other hand, a higher level of spreading was only found on the rougher and isotropic SLA‐Ti at 4 h. In conclusion, although all evaluated Ti surfaces allowed HOC short‐term adhesion, the finer topography introduced by HF as single treatment did not favor HOC mitochondrial activity and spreading. The rougher and more complex SLA surface seems to provide a better substrate for HOC short‐term response. SCANNING 34: 378‐386, 2012. © 2012 Wiley Periodicals, Inc.  相似文献   

18.
The present study aims at characterizing the three‐dimensional (3‐D) morphology of a Co–Cr–Mo dental alloy surface as a result of three different procedures used for polishing it. The sample surface morphology of the sampled surface was examined employing atomic force microscopy (AFM), statistical surface roughness parameters, and fractal analysis. An extra‐hard dental alloy of cobalt–chromium–molybdenum (Co–Cr–Mo) (Wironit®, from BEGO, Bremen, Germany) was prepared and moulded. Different polishing treatments were carried out on three groups of six samples each—a total of 18 samples. The first group contained six electropolished (EP) samples. The second group containing six samples went through a mechanical polishing process employing green rubber discs and a high shine polishing paste applied by a rotating black brush (BB). The third group comprising six samples as well went through a mechanical polishing process by means of green rubber discs, high shine polishing paste, and a rotating deer leather brush (DL). Fractal analysis on the basis of a computational algorithm applied to the AFM data was employed for the 3‐D quantitative characterization of the morphology of the sampled surfaces. The fractal dimension D (average ± standard deviation) of 3‐D surfaces for BB samples (2.19 ± 0.07) is lower than that of the DL samples (2.24 ± 0.08), which is still lower than that of the EP samples (2.27 ± 0.09). The results indicated the BB samples as presenting the lowest values of statistical surface roughness parameters, thus the best surface finish, while the EP samples yielded the highest values. Microsc. Res. Tech. 78:831–839, 2015. © 2015 Wiley Periodicals, Inc.  相似文献   

19.
Cantilever‐based optical interfacial force microscopy (COIFM) was applied to the investigation of the mechanical properties of soft materials to avoid the double‐spring effect and snap‐to‐contact problem associated with atomic force microscopy (AFM). When a force was measured as a function of distance between an oxidized silicon probe and the surface of a soft hydrocarbon film, it increases nonlinearly in the lower force region below ∼10 nN, following the Herzian model with the elastic modulus of ∼50 MPa. Above ∼10 nN, it increases linearly with a small oscillatory sawtooth pattern with amplitude 1–2 nN. The pattern suggests the possible existence of the layered structure within the film. When its internal part of the film was exposed to the probe, the force depends on the distance linearly with an adhesive force of −20 nN. This linear dependence suggests that the adhesive internal material behaved like a linear spring with a spring constant of ∼1 N/m. Constant‐force images taken in the repulsive and attractive contact regimes revealed additional features that were not observed in the images taken in the noncontact regime. At some locations, however, contrast inversions were observed between the two contact regimes while the average roughness remained constant. The result suggests that some embedded materials had spring constants different from those of the surrounding material. This study demonstrated that the COIFM is capable of imaging mechanical properties of local structures such as small impurities and domains at the nanometer scale, which is a formidable challenge with conventional AFM methods. SCANNING 35:59‐67, 2013. © 2012 Wiley Periodicals, Inc.  相似文献   

20.
Zhang X  Liu X  Sun J  He S  Lee I  Pak HK 《Ultramicroscopy》2008,108(10):1338-1341
Osteoblast, playing a key role in the pathophysiology of osteoporosis, is one of the mechanical stress sensitive cells. The effects of mechanical load-induced changes of mechanical properties in osteoblast cells were studied at real-time. Osteoblasts obtained from young Wister rats were exposed to mechanical loads in different frequencies and resting intervals generated by atomic force microscopy (AFM) probe tip and simultaneously measured the changes of the mechanical properties by AFM. The enhancement of the mechanical properties was observed and quantified by the increment of the apparent Young's modulus, E(*). The observed mechanical property depended on the frequency of applied tapping loads. For the resting interval is 50s, the mechanical load-induced enhancement of E(*)-values disappears. It seems that the enhanced mechanical property was recover able under no additional mechanical stimulus.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号