首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
To investigate the morphologic, chemical and crystallographic characters of remineralized surface on initial carious enamel treated with Galla chinensis, scanning electron microscopy equipped with energy dispersive analysis spectroscopy were used, and X‐ray microdiffraction (microzone XRD) was used for the first time to analyze in situ the microzone crystallite of remineralized surface on carious enamel. Bovine sound enamel slabs were demineralized to produce initial carious lesion in vitro. Then, the lesions were exposed to a pH‐cycling regime for 12 days of remineralization. Each daily cycle included 4×1 min applications with one of the three treatments: distilled and deionized water (DDW); 1 g/L NaF; 4 g/L G. chinensis extract (GCE). After the treatments, some rod‐like deposits and many irregular prominences were found on GCE‐treated enamel surface, and the intensities of Ca and P signals showed a tendency to increase; Ca:P ratio was significantly higher than that of DDW‐treated enamel. X‐ray microdiffraction showed hydroxyapatite was still the main component of GCE‐treated enamel, and the crystallinity was increased, the crystal lattice changed gently with decreased lattice parameter a. These results indicated the potential of GCE in promoting the remineralization of initial enamel carious lesions, and supported the previous hypothesis about GCE mechanism. Combined with the anti‐bacteria and demineralization inhibition properties of GCE, the natural G. chinensis may become one more promising agent for caries prevention. SCANNING 31: 236–245, 2009. © 2010 Wiley Periodicals, Inc.  相似文献   

2.
Physiological oral mechanical forces may play a role on the progression of enamel carious lesions to cavitation. Thus, the aim of this study was to describe, by 3D finite element analysis, stress, and strain patterns in sound and carious enamel after a simulated occlusal load. Micro‐CT based models were created and meshed with tetrahedral elements (based on an extracted third molar), namely: a sound (ST) and a carious tooth (CT). For the CT, enamel material properties were assigned according to the micro‐CT gray values. Below the threshold corresponding to the enamel lesion (2.5 g/cm3) lower and isotropic elastic modulus was assigned (E = 18 GPa against E1 = 80 GPa, E2 = E3 = 20 GPa for sound enamel). Both models were imported into a FE solver where boundary conditions were assigned and a pressure load (500 MPa) was applied at the occlusal surface. A linear static analysis was performed, considering anisotropy in sound enamel. ST showed a more efficient transfer of maximum principal stress from enamel to the dentin layer, while for the CT, enamel layer was subjected to higher and concentrated loads. Maximum principal strain distributions were seen at the carious enamel surface, especially at the central fossa, correlating to the enamel cavity seen at the original micro‐CT model. It is possible to conclude that demineralized enamel compromises appropriate stress transfer from enamel to dentin, contributing to the odds of fracture and cavitation. Enamel fracture over a dentin lesion may happen as one of the normal pathways to caries progression and may act as a confounding factor during clinical diagnostic decisions. Microsc. Res. Tech. 78:865–872, 2015. © 2015 Wiley Periodicals, Inc.  相似文献   

3.
The aim of the study was to determine the efficacy of different products containing fluoride, calcium and phosphate for enamel remineralization in eroded primary teeth. A total of 90 sound primary canine teeth were randomly divided into 5 groups of 18 teeth each: 1) control (polished enamel), 2) 5% DuraShield sodium fluoride varnish, 3) 500 ppm fluoridated toothpaste, 4) casein phosphopeptide‐amorphous calcium phosphate (CPP‐ACP) cream, and 5) Clinpro White varnish containing functionalized tri‐calcium phosphate (fTCP). Enamel microhardness (EMH) was measured in all samples before and after demineralization and after 28 days of remineralization. Also 8 samples in groups 2 to 5 and four samples of sound and demineralized enamel were examined with atomic force microscopy (AFM). All data were analyzed with one‐way ANOVA (p<0.05). Mean microhardness of demineralized enamel was significantly lower than in enamel at baseline (p<0.001). Remineralization significantly increased microharness in groups 2 to 5 compared to the control group (p<0.001). Percent EMH after remineralization with CPP‐ACP was significantly higher than after fTCP (p=0.029), toothpaste (p< 0.001) or fluoride varnish (p<0.001); however, there was no significant difference between toothpaste and fluoride varnish (p=0.062). Microhardness increased more after fTCP treatment than after treatment with sodium fluoride varnish (p<0.001) or fluoridated toothpaste (p=0.045). AFM images showed that enamel roughness decreased most after treatment with fTCP, followed by CPP‐ACP, toothpaste and fluoride varnish. The efficacy of CPP‐ACP cream for remineralizing eroded enamel was greater than fluoride toothpaste, fluoride varnish or fTCP varnish. Microsc. Res. Tech. 78:801–806, 2015. © 2015 Wiley Periodicals, Inc.  相似文献   

4.
Various methods have been applied to evaluate the effect of erosion and abrasion. So, the aim of this study was to check the applicability of stylus profilometry (SP), surface hardness (SH) and focus‐variation 3D microscopy (FVM) to the analysis of human enamel and dentin subjected to erosion/abrasion. The samples were randomly allocated into four groups (n = 10): G1‐enamel/erosion, G2‐enamel/erosion plus abrasion, G3‐dentin/erosion, and G4‐dentin/erosion plus abrasion. The specimens were selected by their surface hardness, and they were subjected to cycles of demineralization (Coca‐Cola®‐60 s) and remineralization (artificial saliva‐60 min). For groups G2 and G4, the remineralization procedures were followed by toothbrushing (150 strokes). The above cycle was repeated 3×/day during 5 days. The samples were assessed using SH, SP, and FVM. For each substrate, the groups were compared using an unpaired t‐test, and Pearson correlation coefficients were calculated (α = 5%). For enamel, both profilometry technique showed greater surface loss when the erosion and abrasion processes were combined (P <0.05). The correlation analysis did not reveal any relationships among SH, SP, and FVM to G2 and G4. There were significant correlation coefficients (–0.70 and –0.67) for the comparisons between the FVM and SH methods in enamel and dentin, respectively, in G1 and G3. Choosing the ideal technique for the analysis of erosion depends on the type of dental substrate. SP was not sufficiently sensitive to measure the effects on dentin of erosion or erosion/abrasion. However, SP, FVM and SH were adequate for the detection of tissue loss and demineralization in enamel. Microsc. Res. Tech., 2013. © 2012 Wiley Periodicals, Inc.  相似文献   

5.
Laser irradiation has been proposed as a preventive method against dental caries since it is capable to inhibit enamel demineralization by reducing carbonate and modifying organic matter, yet it can produce significant morphological changes. The purpose of this study was to evaluate the influence of Er:YAG laser irradiation on superficial roughness of deciduous dental enamel and bacterial adhesion. Fifty‐four samples of deciduous enamel were divided into three groups (n = 18 each). G1_control (nonirradiated); G2_100 (7.5 J/cm2) and G3_100 (12.7 J/cm2) were irradiated with Er:YAG laser at 7.5 and 12.7 J/cm2, respectively, under water irrigation. Surface roughness was measured before and after irradiation using a profilometer. Afterwards, six samples per group were used to measure bacterial growth by XTT cell viability assay. Adhered bacteria were observed using confocal laser scanning microscopy (CLSM) and a scanning electron microscopy (SEM). Paired t‐, one‐way analysis of variance (ANOVA), Kruskal‐Wallis and pairwise Mann–Whitney U tests were performed to analyze statistical differences (p < .05). Before treatment, samples showed homogenous surface roughness, and after Er:YAG laser irradiation, the surfaces showed a significant increase in roughness values (p < .05). G3_100 (12.7 J/cm2) showed the highest amount of Streptococcus mutans adhered (p < .05). The increase in the roughness of the tooth enamel surfaces was proportional to the energy density used; the increase in surface roughness caused by laser irradiation did not augment the adhesion of Streptococcus sanguinis; only the use of the energy density of 12.7 J/cm2 favored significantly the adhesion of S. mutans.  相似文献   

6.
The aim of this study was to assess the remineralization of enamel caries lesions using the self-assembling peptide P11-4 associated with different materials. Artificial early enamel lesions were prepared on 154 primary teeth. The samples were randomly divided into eight groups: (1) control, (2) P11-4, (3) fluoridate toothpaste (FT), (4) P11-4 + FT, (5) casein phosphopeptide–amorphous calcium phosphate (CPP–ACP), (6) P11-4 + CPP–ACP, (7) fluoridate bioactive glass toothpaste (BT), and (8) P11-4 + BT. The surface enamel microhardness (EMH) and energy-dispersive X-ray spectroscopy (EDS) of the teeth were then measured at the baseline, after demineralization, and after 28 days of remineralization. The enamel surfaces were assessed by field emission scanning electron microscopy (FESEM) and atomic force microscopy (AFM). The data were analyzed with one-way analysis of variance (ANOVA) (p < .05). EMH after demineralization was significantly lower than the baseline value (p < .001). The interventions led to an enhanced percentage of EMH recovery (%REMH), which was higher in Groups 6 and 7. There was no significant difference between Groups 3 and 4. Groups 1 and 2 had the lowest %REMH. The mean calcium/phosphate weight percentage ratio of P11-4 was significantly lower than the others (p < .001). The FESEM and AFM images revealed mineral deposition on the eroded enamel and reductions in surface roughness in Groups 5 and 7.  相似文献   

7.
The purpose of this study was to: (a) evaluate the role of enamel surface roughness on bond fatigue durability and (b) evaluate statistical differences in roughness values based on measurement technique, including the use of spatial filtering for optical profilometry (OP). OptiBond XTR (Kerr Corp), Prime & Bond elect (DENTSPLY Caulk), Scotchbond Universal (3 M Oral Care), and XTR pre‐etched with Ultra‐Etch phosphoric acid (35%) (Ultradent) self‐etch adhesives were used to treat enamel. A flat ground enamel surface was included as a control. Atomic force microscopy (AFM) and OP were used to measure the surface topography of each enamel surface following the application of adhesives. AFM, OP, and filtered OP (FOP) roughness values, where FOP was designed to only include the lateral spatial resolution consistent with AFM roughness values, were collected. Spatial resolution filtering with OriginPro was used to compare line scans from the two imaging techniques and generate the FOP group. These micro‐ versus nanoscale lateral roughness values were correlated with shear bond and shear fatigue strengths of the adhesives bonded to enamel. Roughness values showed differences based on measurement technique and strong correlations with bond and fatigue strength. The filtered OP group demonstrated the importance of careful usage and reporting of atomic force microscopy and OP metrics in adhesive dentistry. Best practices for surface roughness analysis were also discussed.  相似文献   

8.
The objective of this in vitro study was to analyze and compare the biomimetic remineralizing efficacy of the self‐assembling peptide (P11‐4) with agents containing casein phoshopeptide‐amorhous calcium phosphate fluoride (CPP‐ACFP) and sodium fluoride (NaF) on artificial caries lesions using DIAGNOdent and micro‐computed tomography (μCT). Artificial enamel lesions were prepared on extracted impacted sound mandibular third molars. The samples were randomly allocated to four groups (n = 8): Group 1, P11‐4 (Curodont Repair, Credentis AG, Switzerland); Group 2, CPP‐ACFP (MI Varnish, GCCo., Japan); Group3, NaF (Duraphat Varnish, Colgate, Colgate‐Palmolive, NY, USA); Group 4, artificial saliva (control). The agents were applied to demineralized surfaces according to manufacturers' instructions; all specimens were stored in artificial saliva for 1 month. Demineralization and remineralization on enamel surfaces were analyzed and quantified by DIAGNOdent (KaVo, Germany) and μCT (SkyScan1174, Belgium) for lesion depth/area/volume/mineral density (MD). The remineralization efficacy of the agents was evaluated by DIAGNOdent on 1st, 7th, 30th days and by μCT on 30th day. Data were statistically analyzed by ANOVA, Kruskal–Wallis, T test, and Wilxocon tests. The highest remineralization efficacy findings in all periods were determined in Group 1, followed by Groups 2, 3, and 4. The remineralization findings for fluorescence, MD, lesion depth in Group 1 were found significantly higher (p < 0.01) than Group 3; and no significant differences (p > 0.05) were found between Groups 1–2 and Groups 2–3. The area and volume change values in Groups 1, 2, and 3 have shown no significancy (p > 0.05). A significant correlation (p < 0.01) was found between μCT and DIAGNOdent methods. The data of this study have demonstrated that P11‐4 has showed the best remineralization efficacy, followed by CPP‐ACFP and NaF. It is concluded that self‐assembling peptide‐based remineralization agent can be used successfully for biomimetic remineralization of enamel subsurface lesions.  相似文献   

9.
Aim: To evaluate the surface topography changes in three nickel‐titanium (NiTi) file systems using either rotary or reciprocal motion using atomic force microscopy (AFM), and to determine the effect of scanning area on the AFM results in this study. Methodology: Five points on a F2 Protaper file, R25 Reciproc file, and a Primary file from WaveOne systems were scanned preoperatively in 1 × 1 and 5 × 5 µm2 with an AFM device that can scan an intact (not sectioned) file. One standardized resin block was used for each instrument, according to the manufacturer's recommendations. Points were re‐scanned postoperatively using the same AFM and settings. Root‐mean‐square (RMS) and roughness average (Ra) values were obtained. The preoperative and postoperative surface topographies were compared separately in terms of RMS and Ra values. The surface topography change scores were analyzed using Kruskal–Wallis and Mann–Whitney U tests using a 0.10 significance level. Results: There were no significant differences preoperatively among the NiTi file systems in 1 × 1 or 5 × 5 µm2 areas. Postoperatively, the WaveOne Primary had more surface irregularities (significant for 5 × 5 µm2 scan in Ra evaluation). Conclusions: Three‐dimensional AFM images of instrument surfaces showed topographic irregularities preoperatively and postoperatively. AFM results differ depending on the scanning area and file used. Microsc. Res. Tech. 77:177–182, 2014. © 2013 Wiley Periodicals, Inc.  相似文献   

10.
The present study aimed to evaluate in situ the effect of CO2 laser irradiation to control the progression of enamel erosive lesions. Fifty‐six slabs of bovine incisors enamel (5 × 3 × 2.5 mm3) were divided in four distinct areas: (1) sound (reference area), (2) initial erosion, (3) treatment (irradiated or nonirradiated with CO2 laser), (4) final erosion (after in situ phase). The initial erosive challenge was performed with 1% citric acid (pH = 2.3), for 5 min, 2×/day, for 2 days. The slabs were divided in two groups according to surface treatment: irradiated with CO2 laser (λ = 10.6 µm; 0.5 W) and nonirradiate. After a 2‐day lead‐in period, 14 volunteers wore an intraoral palatal appliance containing two slabs (irradiated and nonirradiated), in two intraoral phases of 5 days each. Following a cross‐over design during the first intraoral phase, half of the volunteers immersed the appliance in 100 mL of citric acid for 5 min, 3×/day, while other half of the volunteers used deionized water (control). The volunteers were crossed over in the second phase. Enamel wear was determined by an optical 3D profilometer. Three‐way ANOVA for repeated measures revealed that there was no significant interaction between erosive challenge and CO2 laser irradiation (P = 0.419). Erosive challenge significantly increased enamel wear (P = 0.001), regardless whether or not CO2 laser irradiation was performed. There was no difference in enamel wear between specimens CO2‐laser irradiated and non‐irradiated (P = 0.513). Under intraoral conditions, CO2 laser irradiation did not control the progression of erosive lesions in enamel caused by citric acid. Microsc. Res. Tech. 77:586–593, 2014. © 2014 Wiley Periodicals, Inc.  相似文献   

11.
This study aimed to evaluate effectiveness and effects of bleaching with 35% hydrogen peroxide with and without calcium on color, micromorphology, and the replacement of calcium and phosphate on the enamel surface. Thirty bovine enamel blocks (5.0 × 5.0 mm) were placed into the following groups: G1: artificial saliva (control); G2: 35% hydrogen peroxide gel without calcium (Whiteness HP Maxx–FGM); and G3: 35% hydrogen peroxide gel with calcium (Whiteness HP Blue–FGM). Three color measurements were performed with a spectrophotometer: untreated (baseline), after performing staining, and after application of bleaching agents. Calcium deposition on the enamel was evaluated before and after the application of bleaching agents using energy‐dispersive X‐ray spectrometry. The enamel surface micromorphology was observed under scanning electron microscopy. The pH of each product was measured. The data were subjected to one‐factor analysis of variance (ANOVA), and any differences were analyzed using Tukey's test (P < 0.05). G3 showed greater variation in total color after the experiment than G2 and G1; there was no significant difference in calcium or phosphorus concentration before and after the experimental procedures; morphological changes were observed only in G2 and G3; and the pH values of the Whiteness HP Maxx and Whiteness HP Blue bleaching agents were 5.77 and 7.79, respectively. The 35% hydrogen peroxide with calcium showed greater bleaching potential, but the addition of calcium had no effect in terms of reducing morphological changes or increasing the calcium concentration on the enamel surface. Microsc. Res. Tech. 78:975–981, 2015. © 2015 Wiley Periodicals, Inc.  相似文献   

12.
Tick‐borne Babesia parasites are responsible for costly diseases worldwide. Improved control and prevention tools are urgently needed, but development of such tools is limited by numerous gaps in knowledge of the parasite–host relationships. We hereby used atomic force microscopy (AFM) and frequency‐modulated Kelvin probe potential microscopy (FM‐KPFM) techniques to compare size, texture, roughness and surface potential of normal and infected Babesia bovis, B. bigemina and B. caballi erythrocytes to better understand the physical properties of these parasites. In addition, AFM and FM‐KPFM allowed a detailed view of extraerythrocytic merozoites revealing shape, topography and surface potential of paired and single parasites. B. bovis‐infected erythrocytes display distinct surface texture and overall roughness compared to noninfected erythrocytes. Interestingly, B. caballi‐infected erythrocytes do not display the surface ridges typical in B. bovis parasites. Observations of extraerythrocytic B. bovis, B. bigemina and B. caballi merozoites using AFM revealed differences in size and shape between these three parasites. Finally, similar to what was previously observed for Plasmodium‐infected erythrocytes, FM‐KPFM images reveal an unequal electric charge distribution, with higher surface potential above the erythrocyte regions that are likely associated with Babesia parasites than over its remainder regions. In addition, the surface potential of paired extraerythrocytic B. bovis Mo7 merozoites revealed an asymmetric potential distribution. These observations may be important to better understand the unique cytoadhesive properties of B. bovis‐infected erythrocytes, and to speculate on the role of differences in the distribution of surface charges in the biology of the parasites.  相似文献   

13.
This study aimed to investigate dentin wettability and surface morphology after selective removal of carious lesion by erbium‐doped yttrium aluminum garnet (Er:YAG) laser, followed by dentin biomodification with carbodiimide (EDC) and chitosan (CHI). Seventy‐eight bovine dentin specimens were submitted to caries induction. Specimens were distributed according to methods of carious removal (n = 39): bur at low‐speed (40,000 rpm) or Er:YAG laser (noncontact mode, 250 mJ/pulse and 4Hz). All specimens were etched with 35% phosphoric acid, and subdivided according to dentin biomodification (n = 13): Control (no biomodification), EDC or CHI. The contact angle (n = 10) between adhesive system (3M ESPE) and dentin surface was measured by a goniometer. Eighteen specimens (n = 3) were analyzed by scanning electron microscopy. Data were analyzed by two‐way ANOVA and Tukey's test (α = .05). The method used to remove carious lesion did not influence the wettability of dentinal surface (p = .748). The angles produced on the remaining dentin after biomodification were influenced (p = .007). CHI promoted higher contact angles (p = .007) and EDC did not differ from the control group (p = .586). In the bur‐treated group, most tubules were open, regardless of which biomodifier was used. Laser modified the organic matrix layer. CHI promoted partially closed tubules in some areas while EDC exposed dentinal tubules. Regardless of which method was used for selective removal of carious lesion, biomodification with EDC did not affect the dentin wettability, whereas CHI changed the wettability of remaining dentin. Both biomodifiers promoted a slight change on dentin morphology.  相似文献   

14.
The aim of this study is to evaluate the effect of whitening toothpaste on the surface roughness of resin-based restorative materials by different measurement methods. Twenty four specimens from each of human enamel, a microhybrid composite and two nanohybrid composites discs (8.0 diameter × 4.0 mm thick) were divided into two groups (n = 12) according to toothbrushing solutıon and subjected to simulation toothbrushing (30,000 cycles) with both distilled water and whitening toothpaste containing blue covarine. Surface roughness was examined using atomic force microscopy (AFM), profilometer, and scanning electron microscopy (SEM), and the data obtained were subjected to analysis. Ra values of Tescera (TES) were significantly higher than Sonicfill 2 (SF2) when brushing both toothbrushing solutions for initial or 30,000 cycles. Roughness increased for SF2 and TES when brushed for 30,000 cycles and was higher than enamel and Herculite XRV Ultra (HXU). Human enamel was obtained lower surface roughness values brushed with toothpaste compared with distilled water. Evaluation of the surface roughness of control groups using the AFM revealed no statistically significant difference between the groups, but significant differences were found using a profilometer. The use of abrasive whitening toothpaste containing blue covarine and the number of brushing cycles affect the surface properties of human enamel and the restorative material, and also, the clinical success of the restoration. Toothbrushing for 30,000 cycles increased the surface roughness of all materials. The type of toothbrushing solution partially has affected surface roughness.  相似文献   

15.
An analytical model is proposed to simulate and predict the surface roughness for different machining conditions in abrasive flow machining (AFM). The kinematic analysis is used to model the interaction between grain and workpiece. Fundamental AFM parameters, such as the grain size, grain concentration, active grain density, grain spacing, forces on the grain, initial topography, and initial surface finish (R a value) of the workpiece are used to describe the grain-workpiece interaction. The AFM process is studied under a systematic variation of grain size, grain concentration and extrusion pressure with initial surface finish of the workpiece. Simulation results show that the proposed model gives results that are consistent with experimental results.  相似文献   

16.
Background: It remains uncertain as to whether or not CO2 laser is able to hinder demineralization of enamel. The possibility to use bovine instead of human teeth on anticariogenic studies with laser has not yet been determined. Purpose: To compare the ability of CO2 laser and fluoride to inhibit caries‐like lesions in human enamel and to test whether a similar pattern of response would hold for bovine enamel. Study Design: Ninety‐six enamel slabs (2 × 2 × 4 mm) (48 from bovine and 48 from human teeth) were randomly distributed according to surface treatment (n = 12): CO2 laser, 5% sodium fluoride varnish (FV), 1.23% acidulated phosphate fluoride (APF) gel, or no treatment (control). Specimens were subjected to a 14‐day in vitro cariogenic challenge. Microhardness (SMH) was measured at 30 μm from the surface. For ultrastructural analysis, additional 20 slabs of each substrate (n = 5) received the same treatment described earlier and were analyzed by SEM. Results: ANOVA and Tukey test ascertained that CO2 laser promoted the least mineral loss (SMH = 252a). Treatment with FV resulted in the second highest values (207b), which was followed by APF (172c). Untreated specimens performed the worst (154d). SEM showed no qualitative difference between human and bovine teeth. APF and control groups exhibited surfaces covered by the smear layer. A granulate precipitate were verified on FV group and fusion of enamel crystals were observed on lased‐specimens. Conclusions: CO2 laser may control caries progression more efficiently than fluoride sources and bovine teeth may be a suitable substitute for human teeth in studies of this nature. Microsc. Res. Tech. 73:1030–1035, 2010. © 2010 Wiley‐Liss, Inc.  相似文献   

17.
Background: Dental erosion is a risk factor for dental health, introduced by today's lifestyle. Topical fluoride applications in the form of varnishes and gel may lead to deposition of fluoride on enamel. Purpose: This in vitro study aimed to evaluate the effect of two fluoride varnishes and one fluoride gel on the dissolution of bovine enamel by acids. Methods: Enamel samples (72) were divided (n = 8): artificial saliva (control‐G1), Pepsi Twist® (G2), orange juice (G3), Duraphat® + Pepsi Twist® (G4), Duraphat® + orange juice (G5), Duofluorid® + Pepsi Twist® (G6), Duofluorid® + orange juice (G7), fluoride gel + Pepsi Twist® (G8), and fluoride gel + orange juice (G9). Fluoride gel was applied for 4 min and the varnishes were applied and removed after 6 h. The samples were submitted to six cycles (demineralization: Pepsi Twist® or orange juice, 10 min; remineralization: saliva, 1 h). Samples were analyzed by energy‐dispersive X‐ray fluorescence (144 line‐scanning). Results: The amount of Ca and P decreased significantly in the samples of G2 and G3, and the Ca/P ratio decreased in G3. Mineral gain (Ca) was greater in G9 samples than in G4 > G3 > G5 > G1, and (P) greater in G7 samples than in G9 > G4‐6 > G2‐3. Conclusions: The protective effect of Duofluorid® was significantly lower than fluoride gel against orange juice. The fluoride varnishes can interfere positively with the dissolution of dental enamel in the presence of acidic beverages. Fluoride gel showed the best protection level to extrinsic erosion with low costs. Microsc. Res. Tech., 2011. © 2010 Wiley‐Liss, Inc.  相似文献   

18.
Cupric oxide (CuO) semiconducting thin films were prepared at various copper sulfate concentrations by dip coating. The copper sulfate concentration was varied to yield films of thicknesses in the range of 445–685 nm by surface profilometer. X‐ray diffraction patterns revealed that the deposited films were polycrystalline in nature with monoclinic structure of (?111) plane. The surface morphology and topography of monoclinic‐phase CuO thin films were examined using scanning electron microscopy (SEM) and atomic force microscopy (AFM), respectively. Surface roughness profile was plotted using WSxM software and the estimated surface roughness was about ~19.4 nm at 30 mM molar concentration. The nanosheets shaped grains were observed by SEM and AFM studies. The stoichiometric compound formation was observed at 30 mM copper sulfate concentration prepared film by EDX. The indirect band gap energy of CuO films was increased from 1.08 to 1.20 eV with the increase of copper sulfate concentrations. Microsc. Res. Tech., 2013. © 2012 Wiley Periodicals, Inc.  相似文献   

19.
The purpose of this paper is to show applicability of multifractal analysis in investigations of the morphological changes of ultra‐structures of red blood cells (RBCs) membrane skeleton measured using atomic force microscopy (AFM). Human RBCs obtained from healthy and hypertensive donors as well as healthy erythrocytes irradiated with neutrons (45 μGy) were studied. The membrane skeleton of the cells was imaged using AFM in a contact mode. Morphological characterization of the three‐dimensional RBC surfaces was realized by a multifractal method. The nanometre scale study of human RBCs surface morphology revealed a multifractal geometry. The generalized dimensions Dq and the singularity spectrum f(α) provided quantitative values that characterize the local scale properties of their membrane skeleton organization. Surface characterization was made using areal ISO 25178‐2: 2012 topography parameters in combination with AFM topography measurement. The surface structure of human RBCs is complex with hierarchical substructures resulting from the organization of the erythrocyte membrane skeleton. The analysed AFM images confirm a multifractal nature of the surface that could be useful in histology to quantify human RBC architectural changes associated with different disease states. In case of very precise measurements when the red cell surface is not wrinkled even very fine differences can be uncovered as was shown for the erythrocytes treated with a very low dose of ionizing radiation.  相似文献   

20.
Vertical Scanning Interferometry (VSI) may induce optical artefacts in surface topography measurements. The influence of these optical artefacts on the calculation of Rk surface roughness parameters, contact stiffness and flow factors were studied. Two surface measurement techniques were used: Atomic Force Microscopy (AFM) and VSI. Calibration grids were used to make it easier to isolate the causes of these artefacts, while a real engineering surface was used to compare these two techniques in an industrially applied case. It was found that the optical artefacts have a large influence on all the roughness parameters, contact stiffness and flow factors calculated on the calibration grids. However, for the engineering surface the differences between AFM and VSI measurements were much smaller.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号