One of the main obstacles of the diffusion of fuel cell electric vehicles (FCEV) is the refueling system. The new stations follow the refueling protocol from the Society of Automotive Engineers where the way to reach the target pressure is not explained. This work analyzes the thermodynamics of a hydrogen fueling station in order to study the effects of the cascade storage system topology on the energy consumption for the cooling facility. It is found that the energy consumption for cooling increases, expanding the total volume of the cascade storage system. Comparing the optimal and the worst volume configurations of the cascade storage tanks at different ambient temperatures, the energy saving is approximately 12% when the average ambient temperature is 20 °C and around 20% when the average ambient temperature is 30 °C. The energy consumption for cooling is significantly influenced by the topology of the cascade storage system and it is particularly relevant in the case of low daily-dispensed amount of hydrogen.  相似文献   

2.
Studies show that compared with the one-buffer system, the cascade storage system has lower energy consumption in high-pressure hydrogen refueling stations. In the present study, practical dynamic models of the whole hydrogen refueling process are established to evaluate the energy consumption. Accordingly, the filling performance of the three-cascade storage system and single tank storage system are analyzed. Moreover, the impact of the three pressure levels and the charging sequence of the three tanks on the energy consumption are investigated. The obtained results show that changing from one buffer to three tanks gives a total energy saving of approximate 34%. For the three-cascade storage system, the total energy consumption increases approximately linearly with the increase of the pressure of the high-pressure tank. Whereas it shows concave curve shape trends with the increase of low-pressure level and the medium-pressure level. Furthermore, the charging sequence from the low-pressure buffer to the high one decreases the total operation energy consumption to a value slightly lower than the adverse charge sequence.  相似文献   

3.
Many countries in Europe are investing in fuel cell bus technology with the expected mobilization of more than 1200 buses across Europe in the following years. The scaling-up will make indispensable a more effective design and management of hydrogen refueling stations to improve the refueling phase in terms of refueling time and dispensed quantity while containing the investment and operation costs. In the present study, a previously developed dynamic lumped model of a hydrogen refueling process, developed in MATLAB, is used to analyze tank-to-tank fuel cell buses (30–40 kgH2 at 350 bar) refueling operations comparing a single-tank storage with a multi-tank cascade system. The new-built Aalborg (DK) hydrogen refueling station serves as a case study for the cascade design. In general, a cascading refueling approach from multiple storage tanks at different pressure levels provides the opportunity for a more optimized management of the station storage, reducing the pressure differential between the refueling and refueled tanks throughout the whole refueling process, thus reducing compression energy. This study demonstrates the validity of these aspects for heavy-duty applications through the technical evaluation of the refueling time, gas heating, compression energy consumption and hydrogen utilization, filling the literature gap on cascade versus single tank refueling comparison. Furthermore, a simplified calculation of the capital and operating expenditures is conducted, denoting the cost-effectiveness of the cascade configuration under study. Finally, the effect of different pressure switching points between the storage tanks is investigated, showing that a lower medium pressure usage reduces the compression energy consumption and increases the station flexibility.  相似文献   

4.
Development of efficient hydrogen refueling station (HRS) is highly desirable to reduce the hydrogen cost and hence the life cycle expense of fuel cell vehicles (FCVs), which is hindering the large scale application of hydrogen mobility. In this work, we demonstrate the optimization of gaseous HRS process and control method to perform fast and efficient refueling, with reduced energy consumption and increased daily fueling capacity. The HRS was modeled with thermodynamics using a numerical integration method and the accuracy for hydrogen refueling simulation was confirmed by experimental data, showing only 2 °C of temperature rise deviation. The refueling protocols for heavy duty FCVs were first optimized, demonstrating an average fueling rate of 2 kg/min and pre-cooling demand of less than 7 kW for 35 MPa type III tanks. Fast refueling of type IV tanks results in more significant temperature rise, and the required pre-cooling temperature is lowered by 20 K to achieve comparable fueling rate. The station process was also optimized to improve the daily fueling capacity. It is revealed that the hydrogen storage amount is cost-effective to be 25–30% that of the nominal daily refueling capacity, to enhance the refueling performance at peak time and minimize the start and stop cycles of compressor. A novel control method for cascade replenishment was developed by switching among the three banks in the order of decreased pressure, and results show that the daily refueling capacity of HRS is increased by 5%. Therefore, the refueling and station process optimization is effective to promote the efficiency of gaseous HRS.  相似文献   

5.
Compressed hydrogen storage is widely used in hydrogen fuel cell vehicles (HFCVs). Cascade filling systems can provide different pressure levels associated with various source tanks allowing for a variable mass flow rate. To meet refueling performance objectives, safe and fast filling processes must be available to HFCVs. The main objective of this paper is to establish an optimization methodology to determine the initial thermodynamic conditions of the filling system that leads to the lowest final temperature of hydrogen in the on-board storage tank with minimal energy consumption. First, a zero-dimensional lumped parameter model is established. This simplified model, implemented in Matlab/Simulink, is then used to simulate the flow of hydrogen from cascade pressure tanks to an on-board hydrogen storage tank. A neural network is then trained with model calculation results and experimental data for multi-objective optimization. It is found to have good prediction, allowing the determination of optimal filling parameters. The study shows that a cascade filling system can well refuel the on-board storage tank with constant average pressure ramp rate (APRR). Furthermore, a strong pre-cooling system can effectively lower the final temperature at a cost of larger energy consumption. By using the proposed neural network, for charging times less than 183s, the optimization procedure predicts that the inlet temperature is 259.99–266.58 K, which can effectively reduce energy consumption by about 2.5%.  相似文献   

6.
A dynamic model has been developed to analyze and optimize the thermodynamics and design of hydrogen refueling stations. The model is based on Dymola software and incorporates discrete components. Two refueling station designs were simulated and compared. The modeling results indicate that pressure loss in the vehicle's storage system is one of the main factors determining the mass flow and peak cooling requirements of the refueling process. The design of the refueling station does not influence the refueling of the vehicle when the requirements of the technical information report J2601 from Society of Automotive Engineers are met. However, by using multiple pressure stages in the tanks at the refueling station (instead of a single high-pressure tank), the total energy demand for cooling can be reduced by 12%, and the compressor power consumption can be reduced by 17%. The time between refueling is reduced by 5%, and the total amount of stored hydrogen at high pressure is reduced by 20%.  相似文献   

7.
The present study investigates the replacement of expansion valves, used in the cascade system of hydrogen fuelling stations, by a series of ejectors. The major advantage of using ejectors is to recover part of the kinetic energy lost during the expansion of a high-pressure primary flow, in order to entrain a lower pressure secondary flow; thus resulting in a more efficient fuelling.Firstly, a quasi-steady 1-D simulation model of the ejector was calibrated using computational fluid dynamics in terms of the main geometry and pressure conditions.Secondly, the quasi-steady 1-D model of the ejector was used in a dynamic model of the hydrogen fuelling station, in order to investigate the influence of its geometry on the transient fuelling performances. Different fuelling scenarios were explored with varying number of buffer tanks in the cascade system of the fuelling station, and different initial pressures in the vehicle's tank. The results show that the replacement of the expansion valve by an ejector may reduce the energy consumption for hydrogen compression by up to 6.5% using two buffer tanks in the cascade system. On the other hand, increasing the number of buffer tanks reduces the energy savings as the driving pressure ratio decreases.  相似文献   

8.
The future success of fuel cell electric vehicles requires a corresponding infrastructure. In this study, two different refueling station concepts for fuel cell passenger cars with 70 MPa technology were evaluated energetically. In the first option, the input of the refueling station is gaseous hydrogen which is compressed to final pressure, remaining in gaseous state. In the second option, the input is liquid hydrogen which is cryo-compressed directly from the liquid phase to the target pressure. In the first case, the target temperature of −33 °C to −40 °C [1] is achieved by cooling down. In the second option, gaseous deep-cold hydrogen coming from the pump is heated up to target temperature. A dynamic simulation model considering real gas behavior to evaluate both types of fueling stations from an energetic perspective was created. The dynamic model allows the simulation of boil-off losses (liquid stations) and standby energy losses caused by the precooling system (gaseous station) dependent on fueling profiles. The functionality of the model was demonstrated with a sequence of three refueling processes within a short time period (high station utilization). The liquid station consumed 0.37 kWh/kg compared to 2.43 kWh/kg of the gaseous station. Rough estimations indicated that the energy consumption of the entire pathway is higher for liquid hydrogen. The analysis showed the high influence of the high-pressure storage system design on the energy consumption of the station. For future research work the refueling station model can be applied to analyze the energy consumption dependent on factors like utilization, component sizing and ambient temperature.  相似文献   

9.
Reliable design and safe operation of heavy-duty hydrogen refueling stations are essential for the successful deployment of heavy-duty fuel cell electric vehicles (FCEVs). Fueling heavy-duty FCEVs is different from light-duty vehicles in terms of the dispensed hydrogen quantities and fueling rates, requiring tailored fueling station design for each vehicle class. In particular, the selection and design of the onboard hydrogen storage tank system and the fueling performance requirements influence the safe design of hydrogen fueling stations. A thermodynamic modeling and analysis are performed to evaluate the impact of various fueling parameters and boundary conditions on the fueling performance of heavy-duty FCEVs. We studied the effect of dispenser pressure ramp rate and precooling temperature, initial tank temperature and pressure, ambient temperature, and onboard storage design parameters, such as onboard storage pipe diameter and length, on the fueling rate and final vehicle state-of-charge, while observing prescribed tank pressure and temperature safety limits. An important finding was the sensitivity of the temporal fueling rate profile and the final tank state of charge to the design factors impacting pressure drop between the dispenser and vehicle tank, including onboard storage pipe diameter selection, and flow coefficients of nozzle, valves, and fittings. The fueling rate profile impacts the design and cost of the hydrogen precooling unit upstream of the dispenser.  相似文献   

10.
Hydrogen has been used as chemicals and fuels in industries for last decades. Recently, it has become attractive as one of promising green energy candidates in the era of facing with two critical energy issues such as accelerating deterioration of global environment (e.g. carbon dioxide emissions) as well as concerns on the depletion of limited fossil sources. A number of hydrogen fueling stations are under construction to fuel hydrogen-driven vehicles. It would be indispensable to ensure the safety of hydrogen station equipment and operating procedure in order to prevent any leak and explosions of hydrogen: safe design of facilities at hydrogen fueling stations e.g. pressurized hydrogen leak from storage tanks. Several researches have centered on the behaviors of hydrogen ejecting out of a set of holes of pressurized storage tanks or pipes. This work focuses on the 3D simulation of hydrogen leak scenario cases at a hydrogen fueling station, given conditions of a set of pressures, 100, 200, 300, 400 bar and a set of hydrogen ejecting hole sizes, 0.5, 0.7, 1.0 mm, using a commercial computational fluid dynamics (CFD) tool, FLACS. The simulation is based on real 3D geometrical configuration of a hydrogen fueling station that is being commercially operated in Korea. The simulation results are validated with hydrogen jet experimental data to examine the diffusion behavior of leak hydrogen jet stream. Finally, a set of marginal safe configurations of fueling facility system are presented, together with an analysis of distribution characteristics of blast pressure, directionality of explosion. This work can contribute to marginal hydrogen safety design for hydrogen fueling stations and a foundation on establishing a safety distance standard required to protect from hydrogen explosion in Korea being in the absence of such an official requirement.  相似文献   

11.
Compared with single-stage hydrogen storage refuelling, cascade storage refuelling has more advantages and significantly reduces cooling energy consumption. In the cascade system, the parameters of cascade storage tanks are critical, especially the initial pressure and volume. This article analyzes the thermodynamic processes in a cascade hydrogen refuelling station (HRS) and establishes the simulation model in Matlab/Simulink platform. The state of charge (SOC) of the onboard storage tank and the cooling energy consumption of the refuelling system are obtained from different initial pressures and volumes of the cascade storage tanks by using the simulation model. These data are introduced into the artificial neural networks in Matlab to generate a relationship between the decision variables and objective functions. The decision variables are optimized to minimize the cooling energy consumption and maximize the SOC through the genetic algorithm and Pareto optimization. So that optimal initial pressure and volume of the cascade storage tanks are determined. The research shows that when the ambient temperature is 293.15 K, and the SOC is 0.98–0.99, using the optimal initial pressure and volume of the cascade storage tanks can reduce the cooling energy consumption by up to 11.43%, compared with the baseline situation. Among the factors affecting cooling energy consumption and SOC, initial pressure is more sensitive than volume, so optimizing initial pressure, especially for the high-pressure cascade storage tank, seems more meaningful than volume. This research is instructive for the construction of the cascade HRS.  相似文献   

12.
Reliable hydrogen fueling stations will be required for the successful commercialization of fuel cell vehicles. An evolving hydrogen fueling station has been in operation in Irvine, California since 2003, with nearly five years of operation in its current form. The usage of the station has increased from just 1000 kg dispensed in 2007 to over 8000 kg dispensed in 2011 due to greater numbers of fuel cell vehicles in the area. The station regularly operates beyond its design capacity of 25 kg/day and enables fuel cell vehicles to exceed future carbon reduction goals today. Current limitations include a cost of hydrogen of $15 per kg, net electrical consumption of 5 kWh per kg dispensed, and a need for faster back-to-back vehicle refueling.  相似文献   

13.
In this study, different hydrogen refueling station (HRS) architectures are analyzed energetically as well as economically for 2015 and 2050. For the energetic evaluation, the model published in Bauer et al. [1] is used and norm-fitting fuelings according to SAE J2601 [2] are applied. This model is extended to include an economic evaluation. The compressor (gaseous hydrogen) resp. pump (liquid hydrogen) throughput and maximum pressures and volumes of the cascaded high-pressure storage system vessels are dimensioned in a way to minimize lifecycle costs, including depreciation, capital commitment and electricity costs. Various station capacity sizes are derived and energy consumption is calculated for different ambient temperatures and different station utilizations. Investment costs and costs per fueling mass are calculated based on different station utilizations and an ambient temperature of +12 °C. In case of gaseous trucked-in hydrogen, a comparison between 5 MPa and 20 MPa low-pressure storage is conducted. For all station configurations and sizes, a medium-voltage grid connection is applied if the power load exceeds a certain limit. For stations with on-site production, the electric power load of the hydrogen production device (electrolyzer or gas reformer) is taken into account in terms of power load. Costs and energy consumption attributed to the production device are not considered in this study due to comparability to other station concepts. Therefore, grid connection costs are allocated to the fueling station part excluding the production device. The operational strategy of the production device is also considered as energy consumption of the subsequent compressor or pump and the required low-pressure storage are affected by it. All station concepts, liquid truck-supplied hydrogen as well as stations with gaseous truck-supplied or on-site produced hydrogen show a considerable cost reduction potential. Long-term specific hydrogen costs of large stations (6 dispensers) are 0.63 €/kg – 0.76 €/kg (dependent on configuration) for stations with gaseous stored hydrogen and 0.18 €/kg for stations with liquid stored hydrogen. The study focuses only on the refueling station and does not allow a statement about the overall cost-effectiveness of different pathways.  相似文献   

14.
Hydrogen fuel cell vehicle (HFCV) is one of the key contributors to sustainable development of the society. For commercial deployment and market acceptability of fuel cell vehicles, efficient storage of hydrogen with an optimum refueling is one of the important challenge. Compressed hydrogen storage in Type IV tanks is a mature and promising technology for on-board application. The fast refueling of the storage tank without overheating and overfilling is an essential requirement defined by SAE J2601. In this regard, station parameters such as hydrogen supply temperature, filling rate and vehicle tank parameters such as filling time strongly influences the storage capacity of the tank, affecting driving range of the fuel cell vehicle. This paper investigates the impact of these parameters on storage density of the tank defined in terms of state of charge. For this, refueling simulation based on SAE J2601 protocol has been performed using computational fluid dynamic approach to investigate the influence of station parameters on storage density of the tank. Further, the root cause analysis was carried out to investigate the contribution of station and vehicle tank parameters for enhancing the storage density of the tank. Finally, the regression model based on these refueling parameters was developed to predict the density attained at different filling conditions. The results confirmed the strong contribution of pressure, filling time, supply temperature and least contribution of temperature, filling rates in enhancing the storage density of the tank. The results can provide new insight into refueling behavior of the Type IV tank for fuel cell vehicle.  相似文献   

15.
Fuel cell vehicles using green hydrogen as fuel can contribute to the mitigation of climate change. The increasing utilization of those vehicles creates the need for cost efficient hydrogen refueling stations. This study investigates how to build the most cost efficient refueling stations to fuel small fleet sizes of 2, 4, 8, 16 and 32 fuel cell busses. A detailed physical model of a hydrogen refueling station was built to determine the necessary hydrogen storage size as well as energy demand for compression and precooling of hydrogen. These results are used to determine the refueling costs for different station configurations that vary the number of storage banks, their volume and compressor capacity.It was found that increasing the number of storage banks will decrease the necessary total station storage volume as well as energy demand for compression and precooling. However, the benefit of adding storage banks decreases with each additional bank. Hence the cost for piping and instrumentation to add banks starts to outweigh the benefits when too many banks are used. Investigating the influence of the compressor mass flow found that when fueling fleets of 2 or 4 busses the lowest cost can be reached by using a compressor with the minimal mass flow necessary to refill all storage banks within 24 h. For fleets of 8, 16 and 32 busses, using the compressor with the maximum investigated mass flow of 54 kg/h leads to the lowest costs.  相似文献   

16.
In the present study, the potential of integrating a Ranque-Hilsch vortex tube (RHVT) in the precooling process for refueling high-pressure hydrogen vehicles in hydrogen refueling stations is investigated. In this regard, two novel precooling processes integrating a vortex tube are proposed to significantly reduce the capital expenditure and operating costs in hydrogen fueling stations. Then a numerical study of the RHVT performance is carried out for a high-pressure hydrogen flow to validate the feasibility of the proposed processes. Obtained results from the numerical simulation show that the energy separation effect also exists in the RHVT with hydrogen flow at the pressure level of tens of megapascals. Moreover, it is found that the energy separation performance of the RHVT improves as the pressure ratio increases. In other words, the temperature drop of the cold exit of RHVT decreases as the pressure ratio decreases in the refueling process, which just matches the slowing-down temperature rise during the cylinder charge. Based on the obtained results, it is concluded that the integration of a RHVT into the precooling process has potential in the hydrogen fueling station.  相似文献   

17.
Hydrogen fuel cell electric vehicles (HFCEVs) are zero-emission vehicles (ZEVs) that can provide drivers a similar experience to conventional internal combustion engine vehicles (ICEVs), in terms of fueling time and performance (i.e. power and driving range). The Society of Automotive Engineers (SAE) developed fueling protocol J2601 for light-duty HFCEVs to ensure safe vehicle fills while maximizing fueling performance. This study employs a physical model that simulates and compares the fueling performance of two fueling methods, known as the “lookup table” method and the “MC formula” method, within the SAE J2601 protocol. Both the fueling methods provide fast fueling of HFCEVs within minutes, but the MC formula method takes advantage of active measurement of precooling temperature to dynamically control the fueling process, and thereby provides faster vehicle fills. The MC formula method greatly reduces fueling time compared to the lookup table method at higher ambient temperatures, as well as when the precooling temperature falls on the colder side of the expected temperature window for all station types. Although the SAE J2601 lookup table method is the currently implemented standard for refueling hydrogen fuel cell vehicles, the MC formula method provides significant fueling time advantages in certain conditions; these warrant its implementation in future hydrogen refueling stations for better customer satisfaction with fueling experience of HFCEVs.  相似文献   

18.
The fuel cell plug in hybrid electric vehicle (FCPHEV) is a near-term realizable concept to commercialize hydrogen fuel cell vehicles (FCV). Relative to conventional FCVs, FCPHEVs seek to achieve fuel economy benefits through the displacement of hydrogen energy with grid-sourced electrical energy, and they may have less dependence on a sparse hydrogen fueling infrastructure. Through the simulation of almost 690,000 FCPHEV trips using geographic information system (GIS) data surveyed from a fleet of private vehicles in the Puget Sound area of Washington State, USA, this study derives the electrical and hydrogen energy consumption of various design and control variants of FCPHEVs. Results demonstrate that FCPHEVs can realize hydrogen fuel consumption reductions relative to conventional FCV technologies, and that the fuel consumption reductions increase with increased charge depleting range. In addition, this study quantifies the degree to which FCPHEVs are less dependent on hydrogen fueling infrastructure, as FCPHEVs can refuel with hydrogen at a lower rate than FCVs. Reductions in hydrogen refueling infrastructure dependence vary with control strategies and vehicle charge depleting range, but reductions in fleet-level refueling events of 93% can be realized for FCPHEVs with 40 miles (60 km) of charge depleting range. These fueling events occur on or near the network of highways at approximately 4% of the rate (refuelings per year) of that for conventional FCVs. These results demonstrate that FCPHEVs are a type of FCV that can enable an effective and concentrated hydrogen refueling network.  相似文献   

19.
Hydrogen refueling stations require high capital investment, with compression and storage comprising more than half of the installed cost of refueling equipment. Refueling station configurations and operation strategies can reduce capital investment while improving equipment utilization. Argonne National Laboratory developed a refueling model to evaluate the impact of various refueling compression and storage configurations and tube trailer operating strategies on the cost of hydrogen refueling. The modeling results revealed that a number of strategies can be employed to reduce fueling costs. Proper sizing of the high-pressure buffer storage reduces the compression requirement considerably, thus reducing refueling costs. Employing a tube trailer to initially fill the vehicle's tank also reduces the compression and storage requirements, further reducing refueling costs. Reducing the cut-off pressure of the tube trailer for initial vehicle fills can also significantly reduce the refueling costs. Finally, increasing the trailer's return pressure can cut refueling costs, especially for delivery distances less than 100 km, and in early markets, when refueling stations will be grossly underutilized.  相似文献   

20.
This paper presents a conceptual design of a solar powered hydrogen fueling station for a single family home in Wallingford, Connecticut, USA. Sixty high-efficiency monocrystalline silicon photovoltaic (PV) solar panels (Total capacity: 18.9 kW) account for approximately 94.7% of the hydrogen home’s power consumption. The fueling station consists of a 165 bar high pressure electrolyzer for on-site production of 2.24 kg/day of hydrogen, three-bank cascade configuration storage tanks (4.26 kg of H2 at 350 bar) and a SAE J2600 compliant hydrogen nozzle. The system produces 0.8 kg/day of hydrogen for a fuel cell vehicle with an average commute of 56 km/day (Fuel mileage: 71 km/kg H2). Safety codes and standards applicable at the facility are described, and a well-to-wheel analysis is performed to contrast the carbon dioxide emissions of conventional gasoline and fuel cell vehicles. The energy efficiency obtained by incorporating a solar-hydrogen system for residential applications is also computed.  相似文献   