首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A major problem in microscopic imaging of ex vivo tissue sections stained with fluorescent agents (e.g. antibodies, peptides) is the confounding presence of background tissue autofluorescence. Autofluorescence limits (1) the accuracy of differentiating background signals from single and multiple fluorescence labels and (2) reliable quantification of fluorescent signals. Advanced techniques such as hyperspectral imaging and spectral unmixing can be applied to essentially remove this autofluorescent signal contribution, and this work attempts to quantify the effectiveness of autofluorescence spectral unmixing in a tumour xenograft model. Whole-specimen single-channel fluorescence images were acquired using excitation wavelengths of 488 nm (producing high autofluorescence) and 568 nm (producing negligible autofluorescence). These single-channel data sets are quantified against hyperspectral images acquired at 488 nm using a prototype whole-slide hyperspectral fluorescence scanner developed in our facility. The development and further refinement of this instrument will improve the quantification of weak fluorescent signals in fluorescence microscopy studies of ex vivo tissues in both preclinical and clinical applications.  相似文献   

2.
By monitoring coenzyme autofluorescence modifications. as an indicator of cell damage. the cellular response to femtosecond near-infrared (NIR) radiation (two-photon absorption) was compared with exposure to low-power UV A radiation (one-photon absorption). Excitation radiation from a tunable Ti-sapphire laser. focused through highnumerical- aperture microscope optics. provided diffractionlimited mlcrobeams of an adjustable peak power. Laser scanning NIR microscopy was used to detect spatially the intracellular distribution of fluorescent coenzymes by fluorescence intensity imaging as well as fluorescence lifetime imaging (T-mapping). Upon the onset of UV or NIR exposure. Chinese hamster ovary cells exhibited blue/green autofluorescence witq a mean lifetime of 2·2 ns. which was attributed to NAD(P)H in mitochondria. Exposure to 365 nm radiation from a high-pressure mercury lamp (1 m W. 300 J cm-2 ) resulted in oxidative stress correlated with increased autofluorescence intensity. onset of nuclear fluorescence. and a fluorescence lifetime decrease. The cellular response to femtosecond NIR micro beams depended significantly on peak power. Peak powers above a threshold value of about 0·5kW (average power: 6mW). 0·55kW (7mW) and 0·8kW (lOmW) at 730nm. 760nm and 800nm. respectively. resulted in the onset of short-lived luminescence with higher intensity (100x) than the intracellular NAD(P)H fluorescence. This luminescence. accompanied by destruction of cellular morphology. was localized and occurred in the mitochondrial region. In contrast. beams at a power of less than 0·5 kW allowed nondestructive fluorophore detection with high spatial and temporal resolution without modification of cellular redox state or cell morphology.  相似文献   

3.
For a deeper understanding of molecular mechanisms within cells and for the realization of predictive biology for intracellular processes at subcellular level, quantitative biology is required. Therefore, novel optical and spectroscopic technologies with quantitative and dynamic output are needed in cell biology. Here, we present a combined approach of novel one-chromophore fluorescence lifetime imaging microscopy to probe the local environment of fluorescent fusion proteins and fluorescence intensity decay shape analysis microscopy to suppress interfering autofluorescence. By applying these techniques, we are able to analyse the subcellular localization and partitioning of a green fluorescence protein fusion of the salt stress-induced protein low temperature induced (LTI)6b in great detail with high spatial and temporal resolution in living cells of Arabidopsis plants.  相似文献   

4.
Measurements of the transport of circulating sulphorhodamine B-labelled albumin into the arterial wall, made by applying digital imaging fluorescence microscopy to sections of arteries fixed in situ , are limited in sensitivity by the low levels of tracer fluorescence and high levels of autofluorescence emitted from the tissue. Three attempts to improve these ratios are described. In the first, spectra of the tracer in solution and of arterial autofluorescence were used to design novel microscope filters for rhodamine-like dyes. By exciting with the rarely used yellow lines of the mercury arc lamp and detecting a narrow band of emission with Stokes shifts as small as 15 nm, the ratio of tracer fluorescence to autofluorescence was tripled. In the second, effects of different fixatives were investigated. Using a model system, it was confirmed that Karnovsky's fixative gives good tracer immobilization but elevates autofluorescence, whereas fixative-free buffer solutions give low autofluorescence but do not retain the tracer. It was further found that simple formaldehyde-based fixatives, hitherto considered to be poor fixatives of albumin, immobilized the tracer as well as the glutaraldehyde-based fixative, whilst giving autofluorescence levels comparable to those seen with buffer alone; they therefore give excellent tracer fluorescence to autofluorescence ratios. In the third, lowering specimen temperature by 50 °C was found to increase the intensity of tracer fluorescence by 30% whilst autofluorescence was unaffected. These data may have relevance to microscopical studies using other tissues and fluorescent tracers.  相似文献   

5.
Chen J  Zhuo S  Luo T  Jiang X  Zhao J 《Scanning》2006,28(6):319-326
The spectral properties of one-photon, two-photon excited autofluorescence and second harmonic generation (SHG) from ex vivo human skin induced by a femtosecond (fs) laser and three visible lasers in backscattering geometry are systematically investigated. Our experimental results indicate that peak position of autofluorescence spectra from the dermis and epidermis shift toward long wavelengths, and the fluorescent intensity decreases when the excitation wavelength increases due to an effect of the excitation wavelength on autofluorescence signals. However, the intensity of the SHG signal in collagen has the maximal value of 800 nm excitation wavelength. This may be the result that the energy of the SHG signal is in resonance with an electronic absorption band. The two-photon excited autofluorescence and SHG intensity all obey a quadratical dependence on the excitation power. Compared with the two-photon excited fluorescence and SHG, the one-photon excited fluorescence in the dermis and epidermis exhibits different spectral characteristics. The investigation of the spectral characteristics of autofluorescence and SHG from ex vivo human skin can provide new insights into morphologic structures and biochemical components of tissues, which are vital for improving the application of laser-induced autofluorescence and SHG spectroscopy technique for noninvasive in vivo tissue diagnostics.  相似文献   

6.
Ulrich V  Fischer P  Riemann I  Königt K 《Scanning》2004,26(5):217-225
An inverted fluorescence microscope was upgraded into a compact three-dimensional laser scanning microscope (LSM) of 65 x 62 x 48 cm dimensions by means of a fast kHz galvoscanner unit, a piezodriven z-stage, and a picosecond (ps) 50 MHz laser diode at 405 nm. In addition, compact turn-key near infrared femtosecond lasers have been employed to perform multiphoton fluorescence and second harmonic generation (SHG) microscopy. To expand the features of the compact LSM, a time-correlated single photon counting unit as well as a Sagnac interferometer have been added to realize fluorescence lifetime imaging (FLIM) and spectral imaging. Using this unique five-dimensional microscope, TauMap, single-photon excited (SPE), and two-photon excited (TPE) cellular fluorescence as well as intratissue autofluorescence of water plant leaves have been investigated with submicron spatial resolution, <270 ps temporal resolution, and 10 nm spectral resolution.  相似文献   

7.
The utility of fluorescence lifetime imaging microscopy (FLIM) for identifying bacteria in complex mineral matrices was investigated. Baseline signals from unlabelled Bacillus subtilis and Euglena gracilis, and Bacillus subtilis labelled with SYTO 9 were obtained using two-photon excitation at 730, 750 and 800 nm, identifying characteristic lifetimes of photosynthetic pigments, unpigmented cellular autofluorescence, and SYTO 9. Labelled and unlabelled B. subtilis were seeded onto marble and gypsum samples containing endolithic photosynthetic cyanobacteria and the ability to distinguish cells from mineral autofluorescence and nonspecific dye staining was examined in parallel with ordinary multichannel confocal imaging. It was found that FLIM enabled discrimination of SYTO 9 labelled cells from background, but that the lifetime of SYTO 9 was shorter in cells on minerals than in pure culture under our conditions. Photosynthetic microorganisms were easily observed using both FLIM and confocal. Unlabelled, nonpigmented bacteria showed weak signals that were difficult to distinguish from background when minerals were present, though cellular autofluorescence consistent with NAD(P)H could be seen in pure cultures, and phasor analysis permitted detection on rocks. Gypsum and marble samples showed similar autofluorescence profiles, with little autofluorescence in the yellow-to-red range. Lifetime or time-gated imaging may prove a useful tool for environmental microbiology. LAY DESCRIPTION : The standard method of bacterial enumeration is to label the cells with a fluorescent dye and count them under high-power fluorescence microscopy. However, this can be difficult when the cells are embedded in soil and rock due to fluorescence from the surrounding minerals and dye binding to ambiguous features of the substrate. The use of fluorescence lifetime imaging (FLIM) can disambiguate these signals and allow for improved detection of bacteria in environmental samples.  相似文献   

8.
Huang Z  Chen R  Li Y  Zhuang H  Chen J  Wang L 《Scanning》2008,30(6):443-447
Autofluorescence spectra and optical imaging of Platymonas subcordiformis after irradiation of diode laser were observed via laser scanning confocal microscopy (LSCM). With 488 nm Ar(+) laser excitation, the horizontal and vertical dimensions of a cup-shaped chloroplast of the irradiation group increased about 10% compared with the control group. The fluorescence spectra were similar between irradiation group and control group with a maximum fluorescence band around 682 nm, whereas the former has a higher intensity. Image of a small circular substance with stronger two-photon autofluorescence (TPA) was obtained when using two-photon excitation wavelength of 800 nm in single-channel mode. Further analysis by the 800 nm excitation based on two independent-channels mode showed an emission band of the small circular substance around 376-505 nm, which corresponded to the eyespot of P. subcordiformis. In lambda scanning mode, with two-photon wavelength of 800 nm excitation, six fluorescence peaks that are located at 465, 520, 560, 617, 660 and 680 nm were observed; the fluorescence intensity of the irradiation group was higher than that of the control group, especially at 520, 560 and 617 nm. As a conclusion, diode laser irradiation can promote chloroplast growth of P. subcordiformis cells in the form of expanding area and the increasing content of protein, phospholipids and chlorophyll. LSCM, especially TPA imaging based on femtosecond laser excitation, provides a nondestructive, real-time and accurate method to study changes of living algal cells under laser irradiation and other environmental factors.  相似文献   

9.
Long-term high-resolution multiphoton imaging of nonlabeled human salivary gland stem cell spheroids has been performed with submicron spatial resolution, 10.5-nm spectral resolution, and picosecond temporal resolution. In particular, the two-photon-excited coenzyme NAD(P)H and flavins have been detected by time-correlated single photon counting (TCSPC). Stem cells increased their autofluorescence lifetimes and decreased their total fluorescence intensity during the adipogenic-differentiation process. In addition, the onset of the biosynthesis of lipid vacuoles was monitored over a period of several weeks in stem-cell spheroids. Time-resolved multiphoton autofluorescence imaging microscopes may become a promising tool for marker-free stem-cell characterization and cell sorting.  相似文献   

10.
Deep ultraviolet (DUV) microscopy is a fluorescence microscopy technique to image unlabeled proteins via the native fluorescence of some of their amino acids. We constructed a DUV fluorescence microscope, capable of 280 nm wavelength excitation by modifying an inverted optical microscope. Moreover, we integrated a nanomanipulator‐controlled micropipette into this instrument for precise delivery of picoliter amounts of fluid to selected regions of the sample. In proof‐of‐principle experiments, we used this instrument to study, in situ, the effect of a denaturing agent on the autofluorescence intensity of single, unlabeled, electrospun fibrinogen nanofibers. Autofluorescence emission from the nanofibers was excited at 280 nm and detected at ~350 nm. A denaturant solution was discretely applied to small, select sections of the nanofibers and a clear local reduction in autofluorescence intensity was observed. This reduction is attributed to the dissolution of the fibers and the unfolding of proteins in the fibers. Microsc. Res. Tech., 2010. © 2010 Wiley‐Liss, Inc.  相似文献   

11.
To determine the application limits of green fluorescent protein (GFP) as a reporter gene or protein tag, we expressed GFP by itself and with fusion protein partners, and used three different imaging methods to identify GFP fluorescence. In conventional epifluorescence photomicroscopy, GFP expressed in cells could be distinguished as a bright green signal over a yellow-green autofluorescence background. In quantitative fluorescence microscopy, however, the GFP signal is contaminated by cellular autofluorescence. Improved separation of GFP signal from HeLa cell autofluorescence was achieved by the combination of confocal scanning laser microscopy using 488-nm excitation, a rapid cut-on dichroic mirror and a narrow-bandpass emission filter. Two-photon excitation of GFP fluorescence at the equivalent of ? 390 nm provided better absorption than did 488-nm excitation. This resulted in increased signal/background but also generated a different autofluorescence pattern and appeared to increase GFP photobleaching. Fluorescence spectra similar to those of GFP alone were observed when GFP was expressed as a fusion protein either with glutathione-S-transferase (GST) or with glucokinase. Furthermore, purified GST?GFP fusion protein displayed an extinction coefficient and quantum yield consistent with values previously reported for GFP alone. In HeLa cells, the cytoplasmic GFP concentration must be greater than ? 1 μM to allow quantifiable discrimination over autofluorescence. However, lower expression levels may be detectable if GFP is targeted to discrete subcellular compartments, such as the plasma membrane, organelles or nucleus.  相似文献   

12.
Three-dimensional maps of cellular metabolic oxidation/reduction states of rabbit cornea in situ were obtained by imaging the fluorescence of the naturally occurring reduced pyridine nucleotides (both reduced nicotinamide-adenine dinucleotide, NADH, and reduced nicotinamide-adenine dinucleotide phosphate, NADPH, denoted here as NAD(P)H). Autofluorescence images with submicrometre lateral resolution were obtained throughout the entire 400 μm thickness of the cornea. Two-photon excitation scanning laser microscopy with near-infrared excitation provided high fluorescence collection efficiency, reduced photodamage, and eliminated ultraviolet chromatic aberration, all of which have previously degraded the visualization of pyridine nucleotide fluorescence. Sharp autofluorescence images of the basal epithelium (40 μm within the cornea) show substantial subcellular detail, providing the ability to monitor autofluorescence intensity changes over time, which reflect changes in oxidative metabolism and cellular dynamics necessary for maintenance of the ocular surface. The autofluorescence was confirmed to be mostly of NAD(P)H origin by cyanide exposure, which increased the fluorescence from all cell types in the cornea by about a factor of two. Autofluorescence images of individual keratocytes in the stroma were observed only after cyanide treatment, while in the predominant extracellular collagen (> 90% of the stromal volume), fluorescence was not distinguished from the background. Observation of keratocyte metabolism demonstrates the sensitivity made available by two-photon microscopy for future redox fluorescence imaging of cellular metabolic states.  相似文献   

13.
The effect of refractive index mismatch on the image quality in two-photon confocal fluorescence microscopy is investigated by experiment and numerical calculations. The results show a strong decrease in the image brightness using high-aperture objectives when the image plane is moved deeper into the sample. When exciting at 740 nm and recording the fluorescence around 460 nm in a glycerol-mounted sample using a lens of a numerical aperture of 1·4 (oil immersion), a 25% decrease in the intensity is observed at a depth of 9 μm. In an aqueous sample, the same decrease is observed at a depth of 3 μm. By reducing the numerical aperture to 1·0, the intensity decrease can be avoided at the expense of the overall resolution and signal intensity. The experiments are compared with the predictions of a theory that takes into account the vectorial character of light and the refraction of the wavefronts according to Fermat's principle. Advice is given concerning how the effects can be taken into account in practice.  相似文献   

14.
Functional alterations are first signs of a starting pathological process. A device that measures parameter for the characterization of the metabolism at the human eye-ground would be a helpful tool for early diagnostics in stages when alterations are yet reversible. Measurements of blood flow and of oxygen saturation are necessary but not sufficient. The new technique of auto-fluorescence lifetime measurement (FLIM) opens in combination with selected excitation and emission ranges the possibility for metabolic mapping. FLIM not only adds an additional discrimination parameter to distinguish different fluorophores but also resolves different quenching states of the same fluorophore. Because of its high sensitivity and high temporal resolution, its capability to resolve multi-exponential decay functions, and its easy combination with laser scanner ophthalmoscopy, multi-dimensional time-correlated single photon counting was used for fundus imaging. An optimized set up for in vivo lifetime measurements at the human eye-ground will be explained. In this, the fundus fluorescence is excited at 446 or 468 nm and the time-resolved autofluorescence is detected in two spectral ranges between 510 and 560 nm as well as between 560 and 700 nm simultaneously. Exciting the fundus at 446 nm, several fluorescence maxima of lifetime t1 were detected between 100 and 220 ps in lifetime histograms of 40 degrees fundus images. In contrast, excitation at 468 nm results in a single maximum of lifetime t1 = 190 +/- 16 ps. Several fundus layers contribute to the fluorescence intensity in the short-wave emission range 510-560 nm. In contrast, the fluorescence intensity in the long-wave emission range between 560 and 700 nm is dominated by the fluorescence of lipofuscin in the retinal pigment epithelium. Comparing the lateral distribution of parameters of a tri-exponential model function in lifetime images of the fundus with the layered anatomical fundus structure, the shortest component (t1 = 190 ps) originates from the retinal pigment epithelium and the second lifetime (t2 = 1,000 ps) from the neural retina. The lifetime t3 approximately 5.5 ns might be influenced by the long decay of the fluorescence in the crystalline lens. In vitro analysis of the spectral properties of expected fluorophores under the condition of the living eye lightens the interpretation of in vivo measurements. Taking into account the transmission of the ocular media, the excitation of NADH is unlikely at the fundus.  相似文献   

15.
Fluorescence lifetime imaging (FLIM) uses the fact that the fluorescence lifetime of a fluorophore depends on its molecular environment but not on its concentration. Molecular effects in a sample can therefore be investigated independently of the variable, and usually unknown concentration of the fluorophore. There is a variety of technical solutions of lifetime imaging in microscopy. The technical part of this paper focuses on time‐domain FLIM by multidimensional time‐correlated single photon counting, time‐domain FLIM by gated image intensifiers, frequency‐domain FLIM by gain‐modulated image intensifiers, and frequency‐domain FLIM by gain‐modulated photomultipliers. The application part describes the most frequent FLIM applications: Measurement of molecular environment parameters, protein‐interaction measurements by Förster resonance energy transfer (FRET), and measurements of the metabolic state of cells and tissue via their autofluorescence. Measurements of local environment parameters are based on lifetime changes induced by fluorescence quenching or conformation changes of the fluorophores. The advantage over intensity‐based measurements is that no special ratiometric fluorophores are needed. Therefore, a much wider selection of fluorescence markers can be used, and a wider range of cell parameters is accessible. FLIM‐FRET measures the change in the decay function of the FRET donor on interaction with an acceptor. FLIM‐based FRET measurement does not have to cope with problems like donor bleedthrough or directly excited acceptor fluorescence. This relaxes the requirements to the absorption and emission spectra of the donors and acceptors used. Moreover, FLIM‐FRET measurements are able to distinguish interacting and noninteracting fractions of the donor, and thus obtain independent information about distances and interacting and noninteracting protein fractions. This is information not accessible by steady‐state FRET techniques. Autofluorescence FLIM exploits changes in the decay parameters of endogenous fluorophores with the metabolic state of the cells or the tissue. By resolving changes in the binding, conformation, and composition of biologically relevant compounds FLIM delivers information not accessible by steady‐state fluorescence techniques.  相似文献   

16.
The real-time uptake of serotonin, a neurotransmitter, by rat leukemia mast cell line RBL-2H3 and 5-hydroxytryptophan by Chinese hamster V79 cells has been studied by fluorescence lifetime imaging microscopy (FLIM), monitoring ultraviolet (340 nm) fluorescence induced by two-photon subpicosecond 630 nm excitation. Comparison with two-photon excitation with 590 nm photons or by three-photon excitation at 740 nm shows that the use of 630 nm excitation provides optimal signal intensity and lowered background from auto-fluorescence of other cellular components. In intact cells, we observe using FLIM three distinct fluorescence lifetimes of serotonin and 5-hydroxytryptophan according to location. The normal fluorescence lifetimes of both serotonin (3.8 ns) and 5-hydroxytryptophan (3.5 ns) in solution are reduced to approximately 2.5 ns immediately on uptake into the cell cytosol. The lifetime of internalized serotonin in RBL-2H3 cells is further reduced to approximately 2.0 ns when stored within secretory vesicles.  相似文献   

17.
In this study, a two‐photon fluorescence microscopic imaging technique is reported for assessment the effect of dynamic hypertonic environment on the overall energy metabolism alteration and adaptation of soil‐living amoeba Dictyostelium discoideum. For that purpose the fluorescence intensity of mitochondrial reduced nicotinamide adenine dinucleotide (NADH) was monitored and quantified in order to evaluate the corresponded metabolic state of monolayer cultured cells. The two‐photon excitation of NADH with 720 nm near infrared irradiation produced blue fluorescence emission with maximum wavelength centered at 460 nm. The benefits of reported noninvasive microscopic technique are the significantly less cellular damage and avoiding the excitation of other biomolecules except of NADH. It enabled to acquire data for NADH levels of the observed cells on agar plate specimen and hypertonic nutrition media in a Petri dish. The method demonstrated also good sensitivity, reproducibility and the obtained results revealed that D. discoideum species form aggregation in hypertonic environment within several minutes with aim to survive. The formed aggregate had amorphous shape and it consisted from dozen amoeba cells, which kept their NADH amount in constant level for few hours. The reported imaging method might be applicable in various studies for characterization of metabolic events and assessment of the cell energy balance in hypertonic environment.  相似文献   

18.
Fourier transform multipixel spectroscopy for quantitative cytology   总被引:2,自引:0,他引:2  
A Fourier transform multipixel spectroscopy system was set up and applied to fluorescence microscopy of single living cells. Continuous fluorescence spectra for all pixels of the cell image were recorded simultaneously by the system. Multiple frames of data were first acquired and stored as a set of interferograms for each pixel of the image; they were then Fourier transformed and used as a spatially organized set of fluorescence spectra. Practical spectral resolution of 5 nm was achieved, typically, for 104 pixels in a single cell. The net result was I ( x y ,λ), the fluorescence intensity ( I ) for each pixel of the image ( x y ), as function of wavelength (λ). The present study demonstrates that multipixel spectroscopy can reveal dynamic processes of the food-digestive cycle in the unicellular Paramecium vulgaris fed with algae. Spectral variability of fluorescence intensity at different cytoplasmic sites pinpointed the location of cellular deposits of chlorophyll (630 nm) and of pheophytin (695 nm), a digestive product of the chlorophyll. Localization of compartmental spectral changes was achieved using a 'similarity mapping' algorithm, followed by enhanced image construction. Similarity mapping based on the fluorescence spectrum of native chlorophyll revealed a highlighted image of the cell cytopharynx structure where algae were ingested. Phagolysosomes, migrating vacuoles and the cytoproct, each containing different ratios of pheophytin, were similarly imaged.  相似文献   

19.
The most difficult task in near-field scanning optical microscopy (NSOM) is to make a high quality subwavelength aperture probe. Recently, we have developed high definition NSOM probes by focused ion beam (FIB) milling. These probes have a higher brightness, better polarization characteristics, better aperture definition and a flatter end face than conventional NSOM probes. We have determined the quality of these probes in four independent ways: by FIB imaging and by shear-force microscopy (both providing geometrical information), by far-field optical measurements (yielding throughput and polarization characteristics), and ultimately by single molecule imaging in the near-field. In this paper, we report on a new method using shear-force microscopy to study the size of the aperture and the end face of the probe (with a roughness smaller than 1.5 nm). More importantly, we demonstrate the use of single molecules to measure the full three-dimensional optical near-field distribution of the probe with molecular spatial resolution. The single molecule images exhibit various intensity patterns, varying from circular and elliptical to double arc and ring structures, which depend on the orientation of the molecules with respect to the probe. The optical resolution in the measurements is not determined by the size of the aperture, but by the high optical field gradients at the rims of the aperture. With a 70 nm aperture probe, we obtain fluorescence field patterns with 45 nm FWHM. Clearly, this unprecedented near-field optical resolution constitutes an order of magnitude improvement over far-field methods like confocal microscopy.  相似文献   

20.
This paper describes an epifluorescence system that uses a pulsed laser source as an excitation source for quantitative fluorescence measurements. A 1 μm diameter portion of the sample can be illuminated with high intensity, short light pulses and the fluorescence can be measured with a fast detection system. Selective excitation is possible at 337 nm and from 357 to 710 nm by using different dyes in the laser system. The spectral bandwidth is 0·1–3 nm. Several advantages over the commonly used systems with continuum spectral sources are indicated, especially when measured intensities are low, as in the case of intrinsic fluorescence of the sample, and where reflection of unwanted excitation light may cause appreciable errors when using conventional light sources.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号