首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
A bio-diatomite dynamic membrane (BDDM) reactor for surface water treatment under a water head of 30, 40, 50, 60 and 70 cm, respectively, was investigated, which was very effective for pollutants removal. The water head exerted strong influences on filtration flux of BDDM during the precoating process, as well as on the formation of BDDM and turbidity variations. A high filtration flux (approximately 200-300 L/m2 h) could be achieved in the long filtration times of BDDM with a stable effluent turbidity of approximately 0.11-0.25 NTU. The BDDM could remove particles larger than 25 μm completely. The adopted sintered diatomite mainly consisted of macro pores, which were beneficial for improving the filtration flux of BDDM. During the backwash stage, the BDDM could be removed completely by the air backwash.  相似文献   

2.
微砂增效结团絮凝技术处理低浊高藻水的中试研究   总被引:1,自引:0,他引:1  
针对西安市汤峪水库夏季水质特点和处理要求,提出并采用微砂增效结团絮凝工艺对该原水处理进行中试研究.微砂增效结团絮凝技术是将微砂增效与结团絮凝有机组合的新型水处理工艺.试验结果表明,利用微砂增效结团絮凝技术处理汤峪水库低浊高藻水是切实可行的,系统具有运行稳定性高、出水水质好等特点,且处理效率明显高于采用回流污泥的增效澄清技术.微砂增效结团絮凝工艺能够有效降低出水浊度和CODMn;当微砂投量0.5 g/L时的过程控制参数为PAC投量15mg/L,PAM投量0.4 mg/L,机械搅拌转速8 r/min,上升流速达35 m/h时,藻类去除率可达80%,CODMn去除率达40%,浊度可控制在1.5 NTU以下.  相似文献   

3.
Wastewater reuse in arid regions is important for the production of a water resource to be utilised for non-potable purposes and to prevent the environmental transmission of disease-causing agents. This study was conducted to evaluate the effect of water quality on the comparative disinfection efficiency of viruses, bacteria and spores by UV irradiation. Furthermore, the microbial quality of effluent produced by coagulation, high rate filtration (HRF) and either UV irradiation or chlorination was determined. Using low pressure collimated beam, a UV dose of 80 mWs/cm2 was needed to achieve a 3-log10 inactivation of either rotavirus SA-11 or coliphage MS2, whereas over 5-log10 inactivation of E. coli was reached with a dose of only 20 mWs/cm2. B. subtilis inactivation was found to be linear up to a dose of 40 mWs/cm2 and then a tailing up to a UV dose of 120 mWs/cm2 was observed. It is worth noting that effluent turbidity of < 5 NTU did not influence the inactivation efficiency of UV irradiation. Operation of a pilot plant to treat secondary effluent by coagulation, HRF and UV disinfection at a UV dose of 80 mWs/cm2 resulted in the production of high quality effluent in compliance with the Israel standards for unrestricted irrigation (< 10 CFU/100 mL faecal coliform and turbidity of < 5 NTU). Sulphite reducing clostridia (SRC) were found to be more resistant than coliphages and F coliform for UV irradiation. The results of this study indicated that UV disinfection is suitable for the production of effluents for unrestricted irrigation of food crops.  相似文献   

4.
载粉末活性炭(PAC)过滤集PAC吸附与过滤于一体,能够应用于微污染原水处理。配水试验结果表明:粒径为1.25-2.5mm,厚度为1000mm的聚苯乙烯滤料层能够用于载PAC过滤。影响过滤效果的主要因素为PAC载量和混凝剂投加量,当混凝剂T3010和聚氯化铝的投加量分别为0.09mg/L和2.5mg/L,PAC载量为2-3g/L滤料时,载PAC过滤处理浊度为20-40NTU的微污染原水的效果达到最佳,对CODMn和浊度都具有很好的去除效果。Z河水作为原水的试验结果表明:载PAC过滤对河水浊度、UV254、CODMn的去除率分别为97%-97.9%、50.9%-63.4%、68.5%-71.4%。  相似文献   

5.
The new 3FM filter (Flexible Fiber Filter Module), implementing very fine nylon fibers as filtration media was tested at pilot scale for the first time on sea water. The objective was to improve the quality of raw sea water to produce water for injection into offshore wells for extraction purposes on oil-bearing fields. Particles larger than 5 microm must be removed from the water of injection to avoid clogging at the point of injection into the porous rock. The purpose of the tests carried out over several months at Palavas Les Flots (France) was to specify the optimal operating conditions of the 3FM filter. Various coagulants and combinations of reagents were tested at velocities ranging between 50 and 200 m(3)/m(2)/h (ground filtration velocity). On raw sea water of about 1 NTU turbidity and at velocities of 100 m(3)/m(2)/h, the filtered water contained about 300 particles per mL larger than 1 microm, and less than 15 particles larger than 5 microm per mL. The filter runs range from one hour to few hours, variable according to the raw water turbidity, the reagent dosing rate and the filtration velocity. Backwashes, a succession of air scours at high air flow rates combined with water phases, the total duration of which did not exceed 1 minute, were shown to be efficient during the three months testing period. 3FM filter performance was promising for many other possible applications.  相似文献   

6.
Virus removal experiments using river water spiked with bacteriophages were conducted by an in-line coagulation-ceramic microfiltration hybrid system to investigate the effects of filtration flux (62.5 and 125 L/(m2 x h)) and type of virus (Qbeta and MS2) on virus removal. In addition, the mass balance of viruses through the hybrid system was analysed by quantifying the infectious and inactive viruses by a combination of the polymerase chain reaction (PCR) method and the plaque forming units (PFU) method. Even when the system was operated at high filtration flux (125 L/(m2 x h)), high virus removal (> 6 log) with short coagulation time (2.4 s) was successfully achieved by dosing polyaluminium chloride (PACI) at more than 1.08 mg-Al/L. Removal performances were different between Qbeta and MS2, although their diameters are almost the same: greater virus removal was achieved for MS2 at PACI dosing of 0.54 mg-Al/L, and for Qbeta at PACI dosing of more than 1.08 mg-Al/L. The combination of the PCR and PFU methods revealed that two phenomena, adsorption to/entrapment in aluminium floc and virucidal activity of PACI, partially account for the high virus removal in the coagulation-MF hybrid system.  相似文献   

7.
Coxsackie B3 (CoxB3) virus was used as a virological tracer for an assessment of the efficiency of pathogen removal by several typical physicochemical treatment and chemical disinfection processes, such as coagulation-filtration, ultra-filtration, and disinfection using chlorine and ozone, with regard to the pathogenic quality of the treated domestic wastewater for reuse purposes. The CoxB3 virus was seeded to sterilized secondary effluent to make a raw water of known pathogenic level. After applying the raw water to each treatment or disinfection process, the residual virus in the finished water was concentrated, and virus assay was carried out by the Tissue Culture Infectious Dose technique. TCID50 was used as an indicative parameter of CoxB3 virus in the raw and treated water. Parallel experiments were also conducted to evaluate the effectiveness of each process for the removal of coliform bacteria. It was noticed from the experiment that both coagulation-filtration and ultrafiltration could achieve substantial removal of TCID50 at about the same level (2-log removal). However, the effect of the two processes on the removal of coliform bacteria was much different: 2-log removal by coagulation-filtration and 4 to 5-log removal by ultrafiltration. The TCID50 removal correlates more closely with the removal of turbidity than that of coliform bacteria. Chlorine was found to be effective in coliform removal but almost had no effect on TCID50. As ozone was applied, a high removal of both coliform bacteria and TCID50 could be obtained.  相似文献   

8.
采用高锰酸钾强化混凝—陶瓷微滤膜集成工艺处理水源水,主要考察了不同高锰酸钾投加量对集成工艺中膜污染状况和出水水质的影响。结果表明,在混凝过程中投加高锰酸钾进行预氧化,与单独的混凝—陶瓷微滤膜集成工艺相比,膜污染速率下降,降低了不可逆膜污染;出水水质得到一定程度的提高,其中UV254、CODMn、DOC、TN去除率分别提高了约3%、10%、5%、16%。另外,出水浊度<0.1 NTU,出水颗粒数水平也得到了很大改善。  相似文献   

9.
A DAF (Dissolved-Air-Flotation) process has been designed considering raw water quality characteristics in Korea. Although direct filtration is usually operated, DAF is operated when freshwater algae blooms occur or raw water turbidity becomes high. Pre-sedimentation is operated in case when the raw water turbidity is very high due to rainstorms. A main feature of this plant is that the operation mode can be changed (controlled) based on the characteristics of the raw water to optimize the effluent quality and the operation costs. Treatment capacity (surface loading rate) and efficiency of DAF was found to be better than the conventional sedimentation process. Moreover, low-density particles (algae and alum flocs) are easily separated while the removal of them by sedimentation is more difficult. One of the main concerns for DAF operation is a high raw water turbidity. DAF is not adequate for raw water, which is more turbid than 100 NTU. In order to avoid this problem, pre-sedimentation basins are installed in the DAF plant to decrease the turbidity of the DAF inflow. For simulation of the actual operation, bench and full-scale tests were performed for highly turbid water conditions. Consequently, it is suggested that pre-sedimentation with optimum coagulation prior to DAF is the appropriate treatment scheme.  相似文献   

10.
The removal of particulate organic material in the first step of wastewater treatment may result in significant savings of reactor volume and energy at wastewater treatment plants, because the organic loading to pursuing unit operations can be reduced. This article describes experiments into the possibility of using turbidity measurements as a tool to quantify the concentration of particles in raw wastewater and, based on the result, assess the organic polymer requirement. A feed forward polymer dosing strategy based on a fixed polymer to influent-turbidity ratio was developed and tested. The experimental work confirms that turbidity measurements can be used to quantify particulate COD. For the investigated wastewater (both untreated and flocculated samples) a linear relationship was found in a wide range of particulate COD (100-900 mg O2 x l(-1)) and turbidity (50-450 NTU). On-line turbidity measurements showed that the particle concentrations in the tested municipal wastewater varied significantly. During dry weather conditions the turbidity fluctuated from 100 to 400 NTU, while in rainy periods fluctuations of 100 to >1,000 NTU were measured. The tested turbidity-related polymer dosing method could be used to create different, constant levels of particle removal, despite large particle concentration variations in the influent. Moreover, it resulted in higher removal efficiencies and a more stable operation compared to the dosing of fixed polymer dose per unit of volume.  相似文献   

11.
Li Y  Yu J  Liu Z  Ma T 《Water science and technology》2012,65(9):1615-1623
The filtration of fecal coliform from a secondary clarifier effluent was investigated using direct rapid sand filters as tertiary wastewater treatment on a pilot scale. The effect of the flocculation dose, flow loading rate, and grain size on fecal coliform removal was determined. Direct rapid sand filters can remove 0.6-1.5 log-units of fecal coliform, depending on the loading rate and grain size distribution. Meanwhile, the flocculation dose has little effect on coliform removal, and increasing the loading rate and/or grain size decreases the bacteria removal efficiency. A model was then developed for the removal process. Bacteria elimination and inactivation both in the water phase and the sand bed can be described by first-order kinetics. Removal was successfully simulated at different loading rates and grain size distributions and compared with the data obtained using pilot-scale filters.  相似文献   

12.
臭氧活性炭深度处理工艺除藻效能研究   总被引:2,自引:2,他引:0  
通过中试除藻试验,研究了臭氧活性炭深度处理工艺的除藻效能。结果表明,经过预臭 氧化和常规工艺处理后,深度处理工艺可再去除67%的含藻量。工艺参数:臭氧投加量2 mg/L,接 触时间15 min,活性炭滤池滤速10 m/h,停留时间12 min。探讨了预臭氧化和深度处理两种组合工 艺的除藻机理和影响因素。  相似文献   

13.
A study was conducted on the distribution of pollutants in treated wastewater and the its safety for re-use purposes. Based on the results of a series of tertiary treatment experiments, the effects of three filtration processes, i.e. coagulation-filtration, ozonation-biological activated carbon filtration (O3-BAC) and ultrafiltration (UF), and two chemical disinfection processes, i.e. chlorination and ozonation, on the safety of water re-use were evaluated. It was found that the concentrations of the main pollutants in the secondary effluent and further filtered water follow a log-normal distribution and, therefore, a log-normal probabilistic function can be used to evaluate the suitability of the treated water for re-use purposes. Among the three filtration processes evaluated, UF is the most effective in turbidity removal but less effective in colour and COD removal, while coagulation-filtration and O3-BAC can ensure a good removal of all these pollutants. Regarding chemical disinfection, although chlorine is very effective in inactivation of coliform bacteria, it can not achieve a substantial decrease in viruses. As ozone is applied, effective virus removal can be achieved.  相似文献   

14.
洗浴废水处理工艺中混凝预处理的作用与效果研究   总被引:1,自引:0,他引:1  
采用混凝沉淀—过滤—固定化生物活性炭—膜滤—UV 消毒工艺处理洗浴废水,整体试验结果比较理想,在物化处理过程中混凝环节至关重要。为此研究了混凝对浊度、LAS、COD_(Cr)、洗浴浴香的处理效果。研究结果表明:当投药量大于25mg/L 时,混凝沉淀可以把平均浊度为65NTU的原水降低到15NTU 以下,对 LAS、COD_(Cr)的去除率可达62%和50%以上,因此混凝是去除洗浴废水中悬浮物质、LAS 和有机污染物有效的物化处理单元;但是混凝不能有效地去除洗浴废水中的浴香。  相似文献   

15.
在常规处理条件下,对西南岷江地区突发性非多砂高浊水进行了原水特性的分析及絮凝优化试验。结果表明,采用单级絮凝、分级沉淀工艺,先投加PAC,60~120s后投加PAM,对高浊度原水有良好的去除效果。原水浊度为15000NTU时,投加200mg/LPAC、0.4~0.5mg/LPAM,静沉30min后,出水浊度为1.73~2.48NTU。  相似文献   

16.
涡流絮凝澄清技术在嘉兴某净水厂中的运用   总被引:1,自引:0,他引:1  
嘉兴某公司净水厂在扩容新建澄清池过程中使用涡流絮凝澄清技术,对<给水排水标准图>中320 m3/h水力循环澄清池S771(八)的内部构造作适当改造:缩短喉管长度,改变第一及第二反应室构造并在反应区加入涡流反应器,沉淀区加设斜管,外形尺寸及结构保持不变.改造后单池处理规模提高到500 m3/h,澄清池出水浊度稳定在3 NTU以下,滤后水浊度小于1 NTU,涡流投资在35元/m3以下.实践表明,涡流絮凝澄清技术具有澄清效率高、出水质量优、适应变化能力强、施工方便等优点.  相似文献   

17.
摘要:在常规处理条件下,对西南岷江地区突发性非多砂高浊水进行了原水特性的分析及絮凝优化试验。结果表明,采用单级絮凝、分级沉淀工艺,先投加PAc,60~120s后投加PAM,对高浊度原水有良好的去除效果。原水浊度为15000NTU时,投加200m∥LPAC、0.4-0.5mg/LPAM,静沉30min后,出水浊度为1.73-2.48NTU。  相似文献   

18.
农村饮水工程根据不同的原水水质条件,宜采用不同的水质净化技术。对地表水浑浊度长年低于20NTU、瞬间不超过60NTU原水,可采用微絮凝直接过滤加消毒或慢滤加消毒净化工艺;浑浊度长年低于500NTU、瞬间不超过1000NTU的原水,采用混凝沉淀(澄清)过滤、消毒的常规净水工艺。对于特殊水质如氟超标的地下水、砷超标的地下水、苦咸水及其他污染水,根据不同情况,可分别采用活性氧化铝吸附法、混凝沉淀法、多介质过滤法、铁盐混凝沉淀法、电渗析法、反渗透法等不同方式予以处理。  相似文献   

19.
以水库春季低浊水为处理对象,采用增效结团流化床工艺进行了中试研究。试验结果表明,利用增效结团流化床工艺处理水库低浊水是切实可行的,具有系统运行稳定性高,出水水质好等特点,而良好的污泥回流是系统高效稳定运行的前提。控制上升流速为20m/h时,通过优化得出适宜的工艺参数:混凝剂聚氯化铝(PAC)投量为11 mg/L左右,助凝剂(PAM)投量为0.25~0.30mg/L,污泥回流比为3%,机械搅拌转速为6r/min。在此条件下,出水浊度可控制在1.0NTU以下。  相似文献   

20.
通过对传统慢滤技术改进,研发了家用自动生物慢滤水处理设备并在甘肃省会宁县进行了实际应用。结果表明,该装置对原水中的浊度、细菌、总大肠菌群均有较好的去除效果,为保障西部农村饮水安全提供了技术支撑。  相似文献   