共查询到19条相似文献,搜索用时 125 毫秒
1.
2.
3.
我国西北地区夏季气候干燥,蒸发冷却技术能以较高的COP值提供辐射供冷和新风系统需要的高温冷水和冷风,形成基于蒸发冷却的辐射供冷空调系统.介绍了复合系统的工作原理和流程,在此基础上,采用Airpak软件模拟了地板辐射供冷加置换通风复合系统以及顶板辐射供冷加置换通风复合系统的室内热环境.模拟结果表明,采用地板辐射供冷的复合系统室内垂直温度梯度大于顶板辐射供冷的复合系统,两系统室内温度场均匀,符合设计要求,并且0.1m和1.1m高对应的室内垂直温度差值均小于3℃,符合ISO7730规定的舒适性标准.CFD模拟结果与试验结果吻合良好,可采用该模拟方法进一步研究复合系统室内热环境. 相似文献
4.
5.
6.
7.
8.
9.
利用可编程控制器对室内光照度进行闭环控制,通过测量室内光照度,并对百叶窗和照明设备进行双重调节,实现了对光照度实时检测和连续控制,将室内光照度稳定在人眼感受舒适的设定值上。同时,辅以人体红外传感器,在无人活动时关闭照明设备和调控系统,可达到节约能源的目的。该系统的开发可有效改善室内光照度的舒适程度,提升智能家居的自动化控制水平。 相似文献
10.
11.
12.
Environmental control strategy via computerized implementation is one of the most efficient approaches to integrate new advanced
knowledge in research of human thermal comfort to a mechanical air-conditioning unit. Recently, a new conceptual development
in designing air-conditioning systems has indicated that the indoor comfort temperature strongly depends upon changes of the
outdoor air temperature rather than to be a conventional fixed temperature set-point. The explanation is due to occupants’
adaptability of thermal comfort to a dynamic environment in terms of their clothing and/or activities while the outdoor temperature
can be explicitly used as an ultimate indicator of such changes to empirical function of the indoor comfort temperature. In
this paper, the first prototype embedded system is developed to emulate such an adaptive algorithm to numerically determine
an indoor comfort temperature for a real-time control in an air-conditioning system. From a theoretical point of view, an
adaptive comfort model together with grey prediction model is presented for exploring a practical application of a comfort
temperature-based control for a single air-conditioned space, so as to show the viability of the proposed methodology by simulated
results. The field studies by interview survey of satisfaction on thermal comfort within an air-conditioned reading room of
a library confirm the viability of the proposed real-time computerized implementation of adaptive indoor comfort temperature
via the embedded system for a conventional air-conditioning unit in practical uses. 相似文献
13.
现在的水源热泵采用的控制系统控制精度不高,不能很好地跟踪系统负荷而运行,特别是在温度的控制上还不具备自适应的能力,因而很难满足舒适性和高效节能的要求。针对这些问题,将模糊控制技术引入地源热泵的控制中,并和传统PID控制算法比较。通过Matal-ab仿真,具体比较模糊控制和PID控制在水源热泵系统控制中的性能,然后做出总结。 相似文献
14.
15.
16.
提出了一种联合室内排风能量法的空气源热泵系统,即将室内排风与环境空气混合,然后再通过空气源热泵的室外换热。该方法既可以缓解空气源热泵系统结霜问题,又为室内热排风热量回收提供新途径。利用全国18个城市的气象数据对该方法的适用性进行分析:室内排风状态为16℃/30%和24℃/60%时,空气源热泵室外机结霜概率分别减少0%~36.17%和10.97%~68.17%。并依据结霜改善情况将该方法的适用性分为4种:不适用、可以采用、建议采用和应当采用。其中,北京、济南、太原、兰州和石家庄5个城市属于应当采用该方法的地区。 相似文献
17.
18.
针对目前对双冷源新风机组与辐射板联合运行供暖系统应用于办公室的运行特性的研究很少的现状,搭建了金属辐射板与双冷源新风机组系统测试平台,测试了金属辐射板与双冷源新风机组空调系统供暖运行状态,以及双冷源新风机组供热性能、空气源热泵制热性能以及室内温度分布特性和室内空气品质.结果表明,金属辐射板与双冷源新风机组空调系统冬季供... 相似文献