首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
High-speed, high-resolution LC separations, using a poly(styrene-divinylbenzene) monolithic column, have been coupled to MALDI MS and MS/MS through an off-line continuous deposition interface. The LC eluent was mixed with alpha-cyano-4-hydroxycinnamic acid matrix solution and deposited on a MALDI plate that had been precoated with nitrocellulose. Deposition at subatmospheric pressure (80 Torr) formed a 250-microm-wide serpentine trace with uniform width and microcrystalline morphology. The deposited trace was then analyzed in the MS mode using a MALDI-TOF/TOF MS instrument. Continuous deposition allowed interrogation of the separation with a high data sampling rate in the chromatographic dimensions, thus preserving the high resolution of narrow peaks (3-5-s peak width at half-height) of the fast monolithic LC. No extracolumn band broadening due to the deposition process was observed. Over 2000 components were resolved in a 10-min linear gradient separation of the model sample, and 386 unique peptides were identified in the subsequent MS/MS analysis. The continuous deposition interface allows the coupling of high-resolution separations to MALDI MS without degradation in separation efficiency, thus enabling high-throughput proteome analysis.  相似文献   

2.
In off-line 2D-HPLC a continuous salt gradient is applied in the first separation dimension. This increases the number of identified proteins from complex samples significantly due to higher chromatographic resolution compared to stepwise elution. Achievement of optimal resolution requires the optimization of the two separation dimensions. The influence of LC elution gradients in the first and second dimensions, of analysis time, of stationary-phase material, and of column dimensions was systematically investigated in order to obtain information on the overall peak capacity of the separation system. Provided data indicate that for complex samples such as an E. coli cell extract, a shallow LC SCX gradient with a high number of collected fractions significantly increases the overall peak capacity while for lower complexity samples short gradients with few fractions were sufficient to obtain a maximum of identified peptides. In addition, column dimensions and materials exhibited a strong effect on the overall efficiency of the 2D HPLC separation. The outcome of these experiments could hence serve as a guideline for investigators to adapt their method for the separation of their specific proteome sample to achieve a maximum of peptide sequence information by 2D LC MS/MS analysis.  相似文献   

3.
We have developed an information-dependent, iterative MS/MS acquisition (IMMA) tool for improving MS/MS efficiency, increasing proteome coverage, and shortening analysis time for high-throughput proteomics applications based on the LC-MALDI MS/MS platform. The underlying principle of IMMA is to limit MS/MS analyses to a subset of molecular ions that are likely to identify a maximum number of proteins. IMMA reduces redundancy of MS/MS analyses by excluding from the precursor ion peak lists proteotypic peptides derived from the already identified proteins and uses a retention time prediction algorithm to limit the degree of false exclusions. It also increases the utilization rate of MS/MS spectra by removing "low value" unidentifiable targets like nonpeptides and peptides carrying large loads of modifications, which are flagged by their "nonpeptide" excess-to-nominal mass ratios. For some samples, IMMA increases the number of identified proteins by ~20-40% when compared to the data dependent methods. IMMA terminates an MS/MS run at the operator-defined point when "costs" (e.g., time of analysis) start to overrun "benefits" (e.g., number of identified proteins), without prior knowledge of sample contents and complexity. To facilitate analysis of closely related samples, IMMA's inclusion list functionality is currently under development.  相似文献   

4.
This study describes a methodology for performing relative quantitation in large-scale proteomic sample comparisons using an LC-MALDI mass spectrometry analytical platform without the use of isotope tagging reagents. The method utilizes replicate analyses of a sample to create a profile of constituent components that are aligned based on LC elution time and mass. Once components from individual runs have been grouped as common "features", the Student's t test is used to determine which components are systematically different between samples. In this study, five HPLC runs of human plasma were compared to five HPLC runs of human serum. About 3889 components were detected in all 10 runs. Of these, 1831 corresponded to approximately 100 known serum proteins, based on MS/MS analysis of one run each from serum and plasma. As expected, fibrinogen alpha, beta, and gamma chains accounted for many of the most significant differences. Therefore, using MALDI, samples containing thousands of peptides can be compared in a minimal amount of time. Moreover, the results of the comparison can be used to guide further MS/MS mode sample interrogation in a result dependent manner.  相似文献   

5.
The identification of differential patterns in data originating from combined measurement techniques such as LC/MS is pivotal to proteomics. Although "shotgun proteomics" has been employed successfully to this end, this method also has severe drawbacks, because of its dependence on largely untargeted MS/MS sequencing and databases for statistical analyses. Alternatively, several MS-signal-based (MS/MS-independent) methods have been published that are mainly based on (univariate) Student's t-tests. Here, we present a more robust multivariate alternative employing linear discriminant analysis. Like the t-test-based methods, it is applied directly to LC/MS data, instead of using MS/MS measurements. We demonstrate the method on a number of simulated data sets, as well as on a spike-in LC/MS data set, and show its superior performance over t-tests.  相似文献   

6.
Choi H  Lee HS  Park ZY 《Analytical chemistry》2008,80(8):3007-3015
An improved method of detection of multiphosphorylated peptides by RPLC-MS/MS analysis under low pH conditions (pH approximately 1.7, 3% formic acid) is demonstrated for the model phosphoproteins, bovine alpha- and beta-casein. Changes in the pH conditions from normal (pH approximately 3.0, 0.1% formic acid) to low (pH approximately 1.7, 3% formic acid) significantly improved the detection limit of multiphosphorylated peptides carrying negative (-) solution charge states. In particular, bovine beta-casein tetraphosphorylated peptide, was detected with a loading amount of only 50 fmol of trypsin-digested bovine beta-casein under low pH conditions, which is 200 times lower than necessary to detect the peptide under normal pH conditions. In order to understand the low pH effect, various loading amounts of trypsin-digested bovine alpha- and beta-caseins were analyzed by RPLC-MS/MS analyses under two different pH conditions. The question of whether the low pH condition improves the detection of multiphosphorylated peptides by increasing ionization efficiencies could not be proven in this study because synthetic multiphosphorylated peptides could not be easily obtained by peptide synthesis. Interestingly, increased hydrophilicity resulting from multiple phosphorylation events is shown to negatively affect the peptide retention on reversed-phase column material. It was also demonstrated that the low pH condition could effectively enhance the retention of multiphosphorylated peptides on reversed-phase column material. The usefulness of low pH RPLC analysis was tested using an actual phosphopeptide-enriched sample prepared from mouse brain tissues. Previously, low pH solvents have been used in SCX fractionation and TiO2 enrichment processes to selectively enrich phosphopeptides during the phosphopeptide enrichment procedure, but the improved detection of multiphosphorylated peptides in RPLC-MS/MS analysis under low pH conditions has not been reported before (Ballif, B. A.; Villen, J.; Beausoleil, S. A.; Schwartz, D.; Gygi, S. P. Mol. Cell. Proteomics 2004, 3, 1093-1101. Villen, J.; Beausoleil, S. A.; Gerber, S. A.; Gygi, S. P. Proc. Natl. Acad. Sci. U.S.A. 2007, 104, 1488-1493. Schlosser, A.; Vanselow, J. T.; Kramer, A. Anal. Chem. 2005, 77, 5243-5250.).  相似文献   

7.
The goal of this study was the development of N-terminal tags to improve peptide identification using high-throughput MALDI-TOF MS and MS/MS. The proposed tags, commercially available fluorescent derivatives of coumarin, can be advantageous for peptide analysis in both MS and MS/MS modes. This paper, part 1, will focus on the influence of derivatization on the intensities of MALDI-TOF MS signals of peptides. Labeling peptides with tags containing the coumarin core was found to enhance the intensities of peptide peaks (in some cases over 40-fold) in MALDI-TOF MS using CHCA and 2,5-DHAP matrixes. The signal enhancement was found to be peptide- and matrix-dependent, being the most pronounced for hydrophilic peptides. No correlation was found between the UV absorptivity of the tags at the excitation wavelengths typical for UV-MALDI and the magnitude of the signal enhancement. Interestingly, peptides labeled with Alexa Fluor 350, a coumarin derivative containing a sulfo group (i.e., bearing strong negative charge), showed a 5-15-fold increase in intensity of MALDI MS signal in the positive ion mode, relative to the underivatized peptides, when 2,5-DHAP was used as the matrix. The Alexa Fluor 350 tag yielded a significantly higher signal relative to that for the CAF tag, likely due to the increased hydrophobicity of the coumarin structure. With 2,5-DHB, a decrease of MALDI MS signal was observed for all coumarin-labeled peptides, again relative to the unlabeled species. These findings support the hypothesis that derivatization with coumarin, a relatively hydrophobic structure, improves incorporation of hydrophilic peptides into hydrophobic MALDI matrixes, such as CHCA and 2,5-DHAP.  相似文献   

8.
A compact disk (CD)-based microfluidic method for selective detection of phosphopeptides by mass spectrometry is described. It combines immobilized metal affinity chromatography (IMAC) and enzymatic dephosphorylation. Phosphoproteins are digested with trypsin and processed on the CD using nanoliter scale IMAC with and without subsequent in situ alkaline phosphatase treatment. This is followed by on-CD matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. Dephosphorylation of the IMAC-enriched peptides allows selective phosphopeptide detection based on the differential mass maps generated (mass shifts of 80 Da or multiples of 80 Da). The CD contains 96 microstructures, each with a 16 nL IMAC microfluidic column. Movement of liquid is controlled by differential spinning of the disk. Up to 48 samples are distributed onto the CD in two equal sets. One set is for phosphopeptide enrichment only, the other for identical phosphopeptide enrichment but combined with in situ dephosphorylation. Peptides are eluted from the columns directly into MALDI target areas, still on the CD, using a solvent containing the MALDI matrix. After crystallization, the CD is inserted into a MALDI mass spectrometer for analysis down to the femtomole level. The average success rate in phosphopeptide detection is over 90%. Applied to noncharacterized samples, the method identified two novel phosphorylation sites, Thr 735 and Ser 737, in the ligand-binding domain of the human mineralocorticoid receptor.  相似文献   

9.
With the advent of soft ionization methods such as MALDI and ESI, mass spectrometry has become the most important technique for the analysis of proteins and peptides. ESI-MS is often preceded by separation of the peptide sample by reversed-phase liquid chromatography (LC). Acetonitrile (ACN) is the most commonly employed organic solvent in LC-ESI-MS analysis of peptides. In this report, we demonstrate that the use of methanol (MeOH) as the organic modifier improves the detection limits for analysis of peptide mixtures such as those found in tryptic digests of proteins. A nanoLC-ESI-quadrupole ion trap instrument (LCQ Deca, ThermoFinnigan) was used to analyze peptide standards, protein digests of known concentrations, and tryptic digests of 2-DGE-separated proteins. MeOH displayed excellent chromatographic performance (separation and sensitivity), and shorter gradient times were possible for chromatographic separation with MeOH versus ACN. Sensitivity levels of a few hundred attomoles were achieved with MeOH; those levels could not be achieved with ACN. In addition, MeOH-based nanoLC-MS/MS yielded superior results for the analysis of digests of 2-DGE-separated proteins. For the 14 protein spots analyzed, the success rate of protein identification with MeOH-based nanoLC-ESI-MS/MS was 100%, with multiple proteins identified in several of the spots. In contrast, ACN-based procedure failed to identify any proteins in 21% of the spots and overall identified 33% fewer proteins than the MeOH-based procedure. In summary, higher sensitivity and shorter gradient times make MeOH an excellent organic modifier for the use in nanoLC-ESI-MS/MS analysis of peptides.  相似文献   

10.
The benefits of high-throughput bioanalysis within the pharmaceutical industry are well established. One of the most significant bottlenecks in bioanalysis is transferring in vivo-generated study samples from their collection tubes during sample preparation and extraction. In most cases, the plasma samples must be stored frozen prior to analysis, and the freeze/thaw (F/T) process introduces thrombin clots that are capable of plugging pipets and automated liquid-transfer systems. A new approach to dealing with this problem involves the use of Ansys Captiva 96-well 20-microm polypropylene filter plates to collect, store frozen, and filter plasma samples prior to bioanalysis. The samples are collected from the test subjects, and the corresponding plasma samples are placed directly into the wells of the filter plate. Two Duoseal (patent pending) covers are used to seal the top and bottom of the plate, and the plate is stored at down to -70 degrees C. Prior to sample analysis, the seals are removed and the plate is placed in a 96-well SPE manifold. As the plasma thaws, it passes (by gravity or mild vacuum) through the polypropylene filter into a 96-well collection plate. A multichannel pipet or automated liquid-transfer system is used to transfer sample aliquots without fear of plugging. A significant advantage of this approach is that, unlike other methods, issues related to incomplete pipetting are virtually eliminated. The entire process is rapid since thawing and filtering take place simultaneously, and if a second F/T cycle is required for reanalysis, it is not necessary to refilter the samples (additional clotting was not observed after three F/T cycles). This technique was tested using monkey, rat, and dog plasma and sodium heparin and EDTA anticoagulants. To assess the possibility of nonspecific binding to the polypropylene filter, a variety of drug candidates from diverse drug classes were studied. Validation data generated for two Lilly compounds from distinct classes, before and after filtering, are presented in this paper as practical examples of this technique. While LC/MS/MS is the primary method of bioanalysis in our laboratory, the technique presented in this paper is applicable to other forms of detection as well.  相似文献   

11.
The effects of a needle-tip repeller electrode on thermospray mass spectra of poly(ethylene glycols) and peptide samples have been studied. A significant increase in ion current was observed for increased repeller potentials in the low-mass region (m/z 300 to m/z 1100) and the high-mass region (m/z 1100 to m/z 1900). The change in ion current is due to a change in ion extraction efficiency because of increased ion diffusion rates. The amount of peptide sample needed for direct injection studies was decreased 1 to 2 orders of magnitude by using an ion source with both a needle-tip repeller electrode and a restricted vaporizer probe tip.  相似文献   

12.
A novel MS/MS-based analysis strategy using isotopomer labels, referred to as "tandem mass tags" (TMTs), for the accurate quantification of peptides and proteins is described. The new tags are designed to ensure that identical peptides labeled with different TMTs exactly comigrate in all separations. The tags require novel methods of quantification analysis using tandem mass spectrometry. The new tags and analysis methods allow peptides from different samples to be identified by their relative abundance with greater ease and accuracy than other methods. The new TMTs permit simultaneous determination of both the identity and relative abundances of peptide pairs using a collision induced dissociation (CID)-based analysis method. Relative abundance measurements made in the MS/MS mode using the new tags are accurate and sensitive. Compared to MS-mode measurements, a very high signal-to-noise ratio is achieved with MS/MS based detection. The new tags should be applicable to a wide variety of peptide isolation methods.  相似文献   

13.
Good reliability of Caco-2 permeability studies requires competent sampling and analytical methods to ensure the comparability of day-to-day experiments. In this work, two n-in-one LC/MS/MS methods based on two different ionization techniques were developed and validated for a group of reference compounds; eight of them are recommended by the Food and Drug Administration (FDA) for the evaluation of oral drug permeability. The performance of a new ionization technique, atmospheric pressure photoionization (APPI), as an interface for quantitative LC/MS analysis was evaluated in comparison to the electrospray ionization (ESI). Generally, the validation parameters, including sensitivity, accuracy, and repeatability, were comparable for the APPI and ESI methods. The main difference was that the linear quantitative range of APPI was 3-4 orders of magnitude (r(2) >/= 0.998) whereas in ESI it was typically 2-3 orders of magnitude (r(2) >/= 0.990). By the APPI and ESI methods, the simultaneous analysis of nine highly heterogeneous compounds was achieved within 5.5-7 min, which leads to significant savings in time and cost of the analyses. The successful validation data indicate the usefulness of both the methods for the rapid and sensitive (LOD values typically 相似文献   

14.
Methods for the absolute quantification of a membrane protein are described using isotopically labeled or unlabeled synthetic peptides as standards. Synthetic peptides are designed to mimic peptides that are cleaved from target analyte proteins by proteolytic or chemical digestion, and the peptides selected serve as standards for quantification by LC/MS/MS on a triple quadrupole mass spectrometer. The technique is complementary to relative quantification techniques in widespread use by providing absolute quantitation of selected targets with greater sensitivity, dynamic range, and precision. Proteins that are found to be of interest by global proteome searches can be selected as targets for quantitation by the present method. This method has a much shorter analytical cycle time (minutes versus hours for the global proteome experiments), making it well suited for high-throughput environments. The present approach using synthetic peptides as standards, in conjunction with proteolytic or chemical cleavage of target proteins, allows mass spectrometry to be used as a highly selective detector for providing absolute quantification of proteins for which no standards are available. We demonstrate that quantification is simple and reliable for the integral membrane protein rhodopsin with reasonable recoveries for replicate experiments using low-micromolar solutions of rhodopsin from rod outer segments.  相似文献   

15.
In this paper, the preparation and performance of long, high-efficiency poly(styrene-divinylbenzene) (PS-DVB), 10-microm-i.d. porous layer open tubular (PLOT) capillary columns are described. PLOT capillaries ( approximately 3% RSD column-to-column retention time), with relatively high permeability, were prepared by in-situ polymerization. Relatively high loading capacities, approximately 100 fmol for angiotensin I and approximately 50 fmol for insulin, were obtained with a 4.2 m x 10-microm-i.d. PLOT column. Low detection levels (attomole to sub-attomole) were achieved when the column was coupled on-line with a linear ion trap MS (LTQ). Analysis of human epidermal growth factor receptor (EGFR), a large transmembrane tyrosine kinase receptor with heterogeneous phosphorylation and glycosylation structures, was obtained at the 25 fmol level. The PLOT column yielded a peak capacity of approximately 400 for the separation of a complex tryptic digest mixture when the sample preparation included a 50-microm-i.d. PS-DVB monolithic precolumn and ESI-MS detection. As an example of the power of the column, 3046 unique peptides covering 566 distinct Methanosarcina acetivorans proteins were identified from a 50 ng in-gel tryptic digest sample combining five cuts in a single LC/MS/MS analysis using the LTQ. The results demonstrate the potential of the PLOT column for high-resolution LC/MS at the ultratrace level.  相似文献   

16.
Zeng Z  Wang Y  Shi S  Wang L  Guo X  Lu N 《Analytical chemistry》2012,84(5):2118-2123
In this paper, a new technique has been proposed to achieve simultaneous peptides/proteins enrichment and wash-free self-desalting on a novel sample support with a circle hydrophobic-hydrophilic-hydrophobic pattern. Upon deposition, the sample solution is first concentrated in a small area by repulsion of the hydrophobic outer layer, and then, the peptides/proteins and coexisting salt contaminants are selectively captured in different regions of the pattern through strong hydrophobic and hydrophilic attractions, respectively. As a result, the detection sensitivity is improved by 2 orders of magnitude better than the use of the traditional MALDI plate, and high-quality mass spectra are obtained even in the presence of NaCl (1 M), NH(4)HCO(3) (100 mM), or urea (1 M). The practical application of this method is further demonstrated by the successful analysis of myoglobin digests with high sequence coverage, demonstrating the great potential in proteomic research.  相似文献   

17.
The analytical capabilities of liquid chromatography tandem mass spectrometry for sensitive and highly selective determination of target compounds in complex biological samples makes it well suited for high-throughput analysis. We report the fast separation of six benzodiazepines isolated from human urine via selected reaction monitoring liquid chromatography/mass spectrometry using short dwell times to accommodate fast-eluting chromatographic peaks. The analytes were extracted from human urine samples along with their deuterium-labeled internal standards by a simple liquid-liquid extraction in 96-well plates. Using four autosamplers coupled to one chromatographic column and one tandem mass spectrometer operated in the turbo ion spray mode with positive ion detection, 1152 samples (12 96-well plates) were analyzed in less than 12 h. Through an electronic switching box designed and constructed in-house, the autosamplers were synchronized with the mass spectrometer so that injections were made as soon as the mass spectrometer was ready to collect data. Each run required 30 s to complete with another 7-8 s for the data system to load the next data file to be collected. Chromatographic integrity and ion current response remained relatively constant for the duration of the analyses. The results show acceptable precision and accuracy and demonstrate the feasibility of using fast separations with tandem mass spectrometry for high-throughout analysis of biological samples containing multiple analytes.  相似文献   

18.
Component identification of complex mixtures, whether they are from polymeric formulations or combinatorial synthesis, by conventional MS/MS techniques generally requires component separation by chromatography or mass spectrometry. An automated means of acquiring simultaneous MS/MS data from a complex mixture without prior separation is obtained from stored waveform ion modulation (SWIM) two-dimensional FTICR MS/MS. The technique applies a series of SWIFT excitation waveforms whose frequency domain magnitude spectrum is a sinusoid increasing in frequency from one waveform to the next. The controlled dissociation of the precursor ions produces an associated modulation of the product ion abundances. Fourier transformation of these abundances reveals the encoded modulation frequency from which connectivities of precursor and product ions are observed. The final result is total assignment of product ions for each precursor ion in a mixture from one automated experiment. We demonstrated the applicability of SWIM 2D-FTICR MS/MS to two diverse samples of industrial importance. We characterized structured polyester oligomers and products derived from combinatorial synthesis. Fragmentation pathways identified in standard serial ion isolation MS/MS experiments were observed for trimethylolpropane/methyl hexahydrophthalic anhydride. A 20-component sample derived from combinatorial synthesis was fragmented, and the template ion along with another key fragment ion was identified for each of the 20 components.  相似文献   

19.
A widespread proteomics procedure for characterizing a complex mixture of proteins combines tandem mass spectrometry and database search software to yield mass spectra with identified peptide sequences. The same peptides are often detected in multiple experiments, and once they have been identified, the respective spectra can be used for future identifications. We present a method for collecting previously identified tandem mass spectra into a reference library that is used to identify new spectra. Query spectra are compared to references in the library to find the ones that are most similar. A dot product metric is used to measure the degree of similarity. With our largest library, the search of a query set finds 91% of the spectrum identifications and 93.7% of the protein identifications that could be made with a SEQUEST database search. A second experiment demonstrates that queries acquired on an LCQ ion trap mass spectrometer can be identified with a library of references acquired on an LTQ ion trap mass spectrometer. The dot product similarity score provides good separation of correct and incorrect identifications.  相似文献   

20.
The goal of this study was the development of N-terminal tags to improve peptide identification using high-throughput MALDI-TOF/TOF MS. Part 1 of the study was focused on the influence of derivatization on the intensities of MALDI-TOF MS signals of peptides. In part 2, various derivatization approaches for the improvement of peptide fragmentation efficiency in MALDI-TOF/TOF MS are explored. We demonstrate that permanent cation tags, while significantly improving signal intensity in the MS mode, lead to severe suppression of MS/MS fragmentation, making these tags unsuitable for high-throughput MALDI-TOF/TOF MS analysis. In the present work, it was found that labeling with Alexa Fluor 350, a coumarin tag containing a sulfo group, along with guanidation of epsilon-amino groups of Lys, could enhance unimolecular fragmentation of peptides with the formation of a high-intensity y-ion series, while the peptide intensities in the MS mode were not severely affected. LC-MALDI-TOF/TOF MS analysis of tryptic peptides from the SCX fractions of an E. coli lysate revealed improved peptide scores, a doubling of the total number of peptides, and a 30% increase in the number of proteins identified, as a result of labeling. Furthermore, by combining the data from native and labeled samples, confidence in correct identification was increased, as many proteins were identified by different peptides in the native and labeled data sets. Additionally, derivatization was found not to impair chromatographic behavior of peptides. All these factors suggest that labeling with Alexa Fluor 350 is a promising approach to the high-throughput LC-MALDI-TOF/TOF MS analysis of proteomic samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号