首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The electrochemical oxidation of an olive mill effluent over Ti–Pt anodes was studied. The effluent had an average total chemical oxygen demand (COD) value of 234 g L?1, soluble COD of 61 g L?1, soluble phenolic content 3.4 g L?1, total solids of 80 g L?1 and pH = 5.1. Experiments were conducted in a 10 L vessel with the effluent recirculating at 1 L s?1. The applied current was varied between 5 and 20 A, the salinity between 1 and 4% NaCl, and experiments were performed with the effluent diluted with water to achieve the desired initial concentration. Emphasis was given to the effect of the presence of solids as well as of varying operating conditions on process performance as assessed in terms of COD, color and phenols removal. In general, degradation of phenols occurred relatively fast with conversion increasing with increasing applied current and decreasing initial organic loading and this was accompanied by low COD removal levels and moderate decolorization. The presence of solids had practically no effect on phenols removal, which, in most cases, was complete in less than about 180 min of reaction. However, oxidation in the presence of solids resulted in a substantial solid fraction being dissolved and this consequently increased sample color and the soluble COD content. The solid content typically found in olive mill effluents may partially impede its treatment by electrochemical oxidation, thus requiring more severe operating conditions and greater energy consumption. Copyright © 2007 Society of Chemical Industry  相似文献   

2.
A study of the effect of organic loading rate on the performance of anaerobic digestion of two‐phase olive mill solid residue (OMSR) was carried out in a laboratory‐scale completely stirred tank reactor. The reactor was operated at an influent substrate concentration of 162 g chemical oxygen demand (COD) dm?3. The organic loading rate (OLR) varied between 0.8 and 11.0 g COD dm?3 d?1. COD removal efficiency decreased from 97.0% to 82.6% when the OLR increased from 0.8 to 8.3 g COD dm?3 d?1. It was found that OLRs higher than 9.2 g COD dm?3 d?1 favoured process failure, decreasing pH, COD removal efficiency and methane production rates (QM). Empirical equations described the effect of OLR on the process stability and the effect of soluble organic matter concentration on the total volatile fatty acids (TVFA)/total alkalinity (TAlk) ratio (ρ). The results obtained demonstrated that rates of substrate uptake were correlated with concentration of biodegradable COD, through an equation of the Michaelis–Menten type. The kinetic equation obtained was used to simulate the anaerobic digestion process of this residue and to obtain the theoretical COD degradation rates in the reactor. The small deviations obtained (equal to or lower than 10%) between values calculated through the model and experimental values suggest that the proposed model predicts the behaviour of the reactor accurately. Copyright © 2007 Society of Chemical Industry  相似文献   

3.
The performance of the hydrolyzation film bed and biological aerated filter (HFB–BAF) combined system in pilot scale (with a daily treatment quantity of 600–1300 m3 d?1), operated for 234 days, for low‐strength domestic sewage was assessed using different amounts of aeration, reflux ratios and hydraulic loading rates (HLR). In steady state it was found that the average removal efficiency of chemical oxygen demand (COD) and biological oxygen demand at 5 days (BOD5) were 82.0% and 82.2% and the average effluent concentrations were 15.8 mg L?1 and 9.4 mg L?1 respectively as the HFB was running at an HLR of 1.25–1.77 m3 m?2 h?1 and the BAF was running at an HLR of 1.56–2.21 m3 m?2 h?1. In general, the removal efficiency of total nitrogen (TN) fluctuated with the HLR, gas–water ratio and reflux ratio, so the ratio of gas to water should be controlled from 2:1 to 3:1 and the reflux ratio should be as high as possible. The effluent concentration of TN was 10.4 mg L?1 and the TN removal averaged 34.3% when the gas–water ratio was greater than 3:1 and the reflux ratio was 0.5. The effluent concentration and removal efficiency of NH4+‐N averaged respectively 2.3 mg L?1 and 78.5%. The overall reduction of total phosphorus (TP) was 30% and the average effluent concentration was 0.95 mg L?1. The removal efficiency of linear alkylbenzene sulfonates (LAS) reached 83.8% and the average effluent concentration was almost 0.9 mg L?1. The effluent concentration and removal efficiency of polychlorinated biphenyls (PCBs) were 0.0654 µ g L?1 and 37.05% respectively when the influent concentration was 0.1039 µ g L?1. The excess sludge containing water (volume 15 m3) was discharged once every 3 months. The power consumption of aeration was 0.06–0.09 kWh of sewage treated. The results show that the HFB–BAF combined technology is suitable for the treatment of low‐concentration municipal sewage in south China. Copyright © 2005 Society of Chemical Industry  相似文献   

4.
BACKGROUND: The combined treatment of olive mill wastewater (OMWW) by applying the anaerobic digestion process and further treatment in a system consisting of filters and membranes is presented. The anaerobic digestion of the OMWW took place in a high rate system, the periodic anaerobic baffled reactor (PABR). Application of the membrane system aimed at purifying the anaerobic effluent. RESULTS: An increase in the organic loading rate was achieved by increasing the influent chemical oxygen demand (COD) and alternatively by decreasing the hydraulic retention time (HRT). The first option caused process failure, since the volatile fatty acids accumulation resulted in negligible biogas production. In contrast, the second change (decrease in HRT) led to stable operation that permitted the reduction of the HRT to 3.75 d and increase of the organic loading rate to 8.9 g tCOD L?1 d?1 with satisfactory total COD removal (72%). Higher total COD removal (up to 80%) was observed at lower organic loading rates (<3.5 g tCOD L?1 d?1). Further purification in the membrane units resulted in a final permeate of less than 0.1 g tCOD L?1. The membrane systems proved to be more efficient on the anaerobic effluent than on the raw OMWW (the final permeate in that case contained 1g tCOD L?1). CONCLUSIONS: The anaerobic digestion of OMWW in a PABR was stable even at high organic loading rates. Filtering and membrane fractionation of the PABR effluent resulted in a final permeate stream of high quality, suitable for irrigation and/or reuse in the proposed operating scheme for diluting the OMWW prior to anaerobic digestion. Copyright © 2009 Society of Chemical Industry  相似文献   

5.
This work reports for the first time the removal of 17α‐ethynylestradiol (EE2), a synthetic estrogen hormone, from secondary treated effluents by electrochemical oxidation. Experiments were conducted in a single compartment reactor comprising a boron‐doped diamond (BDD) anode and a zirconium cathode. EE2, in the range 100–800 µg L?1, was spiked in the post‐chlorination effluent of a municipal treatment plant and oxidized at 0.9–2.6 mA cm?2 current density. Complete degradation of 100 µg L?1 EE2 was achieved in 7 min at 2.1 mA cm?2 and inherent conditions, while the addition of 0.1 mol L?1 NaCl achieved removal in just a few seconds. The process was then tested in the pre‐chlorination effluent at 2.1 mA cm?2 and inherent conditions; complete E. coli killing and EE2 removal occurred in just 1.5 and 3.5 min, respectively, while overall estrogenicity (assessed by the YES assay) and residual organic matter (in terms of chemical oxygen demand (COD)) decreased by 50% and 85% after 30 min, respectively. These results clearly show the potential of BBD electrochemical oxidation to serve as an efficient tertiary wastewater treatment. Copyright © 2011 Society of Chemical Industry  相似文献   

6.
A study of the effect of organic volumetric loading rate (BV) on the performance of a down‐flow anaerobic fixed bed reactor (DFAFBR) treating settled piggery waste was carried out at a range of between 1.1 and 6.8 g COD dm?3 d?1. The reactor operated at good removal efficiencies and stability under the operational conditions studied. Logarithmic empirical equations described adequately the removal efficiency for different parameters studied (COD, SCOD, BOD, TS, VS, TSS, VSS and phosphorous). Although process stability was affected by the increase of BV, process failure was not observed. A logarithmic relationship was found to describe the influence of BV on the TVFA/alkalinity ratio (p). A linear correlation was found between the effluent substrate concentration and the values of p and between p and the CO2/CH4 ratio in the biogas. The effect of the hydraulic volumetric loading rate (HV) on the flow pattern of the reactor was evaluated. Dispersion number (Dn) was in the range of 0.17–0.37 for the maximum and minimum values of HV studied, respectively. The ratio between the real and theoretical HRT increased as the HV decreased. These results demonstrate that axial dispersion increased as the HV and the Reynolds number decreased. Due to the hydraulic behaviour of the reactor, the kinetic model developed by Lawrence and McCarty was used for describing the experimental results obtained. Maximum specific substrate removal rate (K), specific organic loading rate constant (KL), microbial decay coefficient (Kd), microbial yield coefficient (Y), maximum microbial growth rate (UM) and saturation constant (KS) were found to be: 3.1 (g COD g VSS?1 d?1), 3.0 (g COD g VSS?1 d?1), 0.062 (d?1), 0.15 (g VSS g COD removed?1), 0.39 (d?1) and 2.6 (g SCOD dm?3), respectively. Copyright © 2004 Society of Chemical Industry  相似文献   

7.
BACKGROUND: This study considers batch treatment of saline wastewater in an upflow anaerobic packed bed reactor by salt tolerant anaerobic organisms Halanaerobium lacusrosei . RESULTS: The effects of initial chemical oxygen demand (COD) concentration (COD0 = 1880–9570 mg L?1), salt concentration ([NaCl] = 30–100 g L?1) and liquid upflow velocity (Vup = 1.0–8.5 m h?1) on COD removal from salt (NaCl)‐containing synthetic wastewater were investigated. The results indicated that initial COD concentration significantly affects the effluent COD concentration and removal efficiency. COD removal was around 87% at about COD0 = 1880 mg L?1, and efficiency decreased to 43% on increasing COD0 to 9570 mg L?1 at 20 g L?1 salt concentration. COD removal was in the range 50–60% for [NaCl] = 30–60 g L?1 at COD0 = 5200 ± .100 mg L?1. However, removal efficiency dropped to 10% when salt concentration was increased to 100 g L?1. Increasing liquid upflow velocity from Vup = 1.0 m h?1 to 8.5 m h?1 provided a substantial improvement in COD removal. COD concentration decreased from 4343 mg L?1 to 321 mg L?1 at Vup = 8.5 m h?1, resulting in over 92% COD removal at 30 g L?1 salt‐containing synthetic wastewater. CONCLUSION: The experimental results showed that anaerobic treatment of saline wastewater is possible and could result in efficient COD removal by the utilization of halophilic anaerobic bacteria. Copyright © 2008 Society of Chemical Industry  相似文献   

8.
BACKGROUND: This study focused on the effectiveness of the zero‐valent iron (ZVI) pre‐treatment for enhancing the biodegradability of 2‐chloronitrobenzene (2‐ClNB), and further to evaluate the performance and mechanism of a coupled ZVI column–sequencing batch reactor (SBR) system treating 2‐ClNB contained wastewater. RESULTS: 2‐ClNB was readily transformed into 2‐chloroaniline (2‐ClAn) with the efficiency over 99.9% by ZVI column, and its biodegradability was significantly enhanced via ZVI pretreatment. The transformed effluent was subsequently fed into the SBR followed by 2‐ClAn loading of 3.4–117.2 g m?3 d?1 and COD loading around 1000 g m?3 d?1. A 2‐ClAn removal efficiency over 99.9% and COD removal efficiency of 82.0–98.1% were obtained. Moreover, 91.9 ± 0.1% TOC removal efficiency and 107.1 ± 6.0% chloride recovery efficiency during one cycle confirmed the complete biodegradation of 2‐ClAn in the coupled system. 16S rDNA PCR‐DGGE analysis suggested that ZVI pretreatment enhanced the diversity of the microbial community and promoted enrichment of the functional microorganisms degrading 2‐ClAn in the following SBR. CONCLUSION: ZVI pretreatment significantly enhanced the biodegradability of 2‐ClNB, and the coupled ZVI–SBR system demonstrated excellent performance when treating wastewater containing 2‐ClNB. Copyright © 2011 Society of Chemical Industry  相似文献   

9.
A new effluent treatment scheme is proposed for treating palm oil mill effluent based on coagulation and anaerobic digestion of coagulated sludge. The effectiveness of anionic (N9901) and cationic (N9907) polyelectrolytes manufactured by NALCO (Malaysia) was evaluated both as coagulant and coagulant aid. The results showed that the anionic and cationic polyelectrolytes were best suited as a coagulant aid, and the cationic polyelectrolyte showed better performance than the anionic polyelectrolyte. For an influent chemical oxygen demand (COD) concentration of 59 700 mg L?1 at an alum dosage of 1700 mg L?1, the residual COD, suspended solid removal, sludge volume and pH were found to be 39 665 mg L?1, 87%, 260 mL L?1 and 6.3, respectively. For the above influent COD and alum dosage with the addition of 2 mg L?1 of cationic polyelectrolyte as coagulant aid, the results were 30 870 mg L?1, 90%, 240 mL L?1 and 6.2, respectively. The sludge resulting from the coagulation process using alum as coagulant and cationic polyelectrolyte as coagulant aid was tested for its digestibility in an anaerobic digester. The quantity of biogas generated per gram of volatile solids (VS) destroyed at a loading rate of 26.7 ± 0.5 and 35.2 ± 0.4 g VS L?1 d?1 was found to be 0.68 and 0.72 L g?1 VS destroyed. The anaerobic biomass when subjected to varying alum dosage in the coagulated palm oil sludge did not exhibit inhibition as the digester performance was in conformity with the regular treatment process Copyright © 2006 Society of Chemical Industry  相似文献   

10.
The capability of biological nutrient removal from wastewater of a novel laboratory‐scale twin fluidized‐bed bioreactor (TFBBR) was studied. The work showed approximately 96 % organic matter, 84 % nitrogen, and 12 % phosphorus removal efficiencies in the first three phases of the study at influent synthetic municipal wastewater (SMW) flow rates of 150, 190, and 240 L/d, with corresponding organic loading rates of 1.3, 1.7, and 2.3 kg COD m–3 d–1 and nitrogen loading rates of 0.14, 0.18 and 0.25 kg N m–3 d–1. The TFBBR effluent was characterized by <1.0 mg NH4‐N/L, <4.3 mg NO3‐N/L, <6 mg TN/L, <6 mg SBOD/L, and 6–10 mg VSS/L. For the three phases, biomass yields of 0.06, 0.066, and 0.071 g VSS/g COD were observed, respectively, which was a significant further reduction in yield compared to the liquid‐solid circulating fluidized‐bed bioreactor technology developed and patented by this research group, of 0.12–0.16 g VSS/g COD. The very low yield was due to a longer solid retention time of 72–108 d.  相似文献   

11.
The degradation of a non‐inhibitory substrate (sucrose) in upflow anaerobic sludge bed (UASB) reactors with different superficial flow velocites (us) was performed to generate experimental data. Additionally, a kinetic model accounting for the mass fraction of methanogens (f) and granule size distribution in UASB reactors is also proposed. At the volumetric loadings of 2.65–21.16 g COD dm?3 day?1, both the COD removal efficiency and granule size of the UASB reactors increase with increasing us. The f values determined experimentally increase from 0.13–0.24 to 0.27–0.43 if the volumetric loading is increased from 2.65 to 5.29 g COD dm?3 day?1. With a further increase in volumetric loading, the f values decline because of the accumulation of volatile fatty acids (VFAs). The predicted residual concentrations of VFAs and COD are in fairly good agreement with the experimental data. From the calculated effectiveness‐factor values, the influence of mass transfer resistance of the substrate sucrose on the overall substrate removal rate should not be neglected. From parametric sensitivity analyses together with the simulated concentration profiles, methanogenesis is the rate‐limiting step. Copyright © 2003 Society of Chemical Industry  相似文献   

12.
Wastewaters generated by a factory processing marine products are characterized by high concentrations of organic compounds and salt constituents (>30 g dm?3). Biological treatment of these saline wastewaters in conventional systems usually results in low chemical oxygen demand (COD) removal efficiency, because of the plasmolysis of the organisms. In order to overcome this problem a specific flora was adapted to the wastewater from the fish‐processing industry by a gradual increase in salt concentrations. Biological treatment of this effluent was then studied in a continuous fixed biofilm reactor. Experiments were conducted at different organic loading rates (OLR), varying from 250 to 1000 mg COD dm?3 day?1. Under low OLR (250 mg COD dm?3 day?1), COD and total organic carbon (TOC) removal efficiencies were 92.5 and 95.4%, respectively. Thereafter, fluctuations in COD and TOC were observed during the experiment, provoked by the progressive increase of OLR and the nature of the wastewater introduced. High COD (87%) and TOC (99%) removal efficiencies were obtained at 1000 mg COD dm?3 day?1. © 2002 Society of Chemical Industry  相似文献   

13.
有效碱度对螺旋式自循环厌氧反应器性能的影响   总被引:1,自引:0,他引:1  
采用模拟废水研究了有效碱度对螺旋式自循环(SPAC))厌氧反应器运行性能的影响.结果表明,SPAC厌氧反应器的最大容积负荷为53.0 g/(L·d),化学耗氧量(CDD)去除率为84.2%,容积负荷承载力为44.6 g/(L·d),容积沼气产率为21.50 L/(L·d).在最佳工况下,碱度供给速率为9.6 g/(L·d).碱度消耗速率为4.8 g/(L·d),有效碱度为1 000 mg/L.进水碱度与进水COD之比为0.19,出水碱度与挥发性有机酸(VFA)之比(ALKout/VFA)为1.75,消耗碱度与去除COD之比为0.10.  相似文献   

14.
The objective of this research was to evaluate the feasibility, the stability and the efficiency of a start‐up at 20 °C and 25 °C of anaerobic sequencing batch reactors (ASBRs) treating slaughterhouse wastewater. Influent chemical oxygen demand (COD) and suspended solids concentrations averaged 7500 and 1700 mg dm?3, respectively. Reactor start‐up was completed in 168 and 136 days at 20 °C, and 25 °C, respectively. The start‐up process was stable at both temperatures, except for a short period at 20 °C, when effluent volatile fatty acid (VFA) concentrations increased from an average of 40 to 400 mg dm?3. Effluent quality varied throughout start‐up, but in the last 25 days of the experiment, as the ASBRs were operated under organic loading rates of 2.25 ± 0.21 and 2.86 ± 0.24 kg m?3 d?1 at 20 °C and 25 °C, respectively, total COD was reduced by 90.3% ± 1.3%. Methanogenesis was not a limiting factor during start‐up. At 20 °C, the limiting factor was the acidification of the soluble organics and, to a smaller extent, the reduction of propionic, isobutyric and isovaleric acids into lower VFAs. At 25 °C, the limiting factor was the hydrolysis of particulate organics. To minimize biomass loss during the start‐up period, the organic loading rate should be increased only when 75 –80% of the COD fed has been transformed into methane within the design hydraulic retention time. © 2001 Society of Chemical Industry  相似文献   

15.
A new membrane‐assisted hybrid bioreactor was developed to remove ammonia and organic matter. This system was composed of a hybrid circulating bed reactor (CBR) coupled in series to an ultrafiltration membrane module for biomass separation. The growth of biomass both in suspension and biofilms was promoted in the hybrid reactor. The system was operated for 103 days, during which a constant ammonia loading rate (ALR) was fed to the system. The COD/N‐NH4+ ratio was manipulated between 0 and 4, in order to study the effects of different organic matter concentrations on the nitrification capacity of the system. Experimental results have shown that it was feasible to operate with a membrane hybrid system attaining 99% chemical oxygen demand (COD) removal and ammonia conversion. The ALR was 0.92 kg N‐NH4+ m?3 d?1 and the organic loading rate (OLR) achieved up to 3.6 kg COD m?3 d?1. Also, the concentration of ammonia in the effluent was low, 1 mg N‐NH4+ dm?3. Specific activity determinations have shown that there was a certain degree of segregation of nitrifiers and heterotrophs between the two biomass phases in the system. Growth of the slow‐growing nitrifiers took place preferentially in the biofilm and the fast‐growing heterotrophs grew in suspension. This fact allowed the nitrifying activity in the biofilm be maintained around 0.8 g N g?1 protein d?1, regardless of the addition of organic matter in the influent. The specific nitrifying activity of suspended biomass varied between 0.3 and 0.4 g N g?1 VSS d?1. Copyright © 2004 Society of Chemical Industry  相似文献   

16.
The direct treatment of whey wastewater at various sludge ages (10–75 days) and high biomass concentration (above 50 g mixed liquor suspended solid (MLSS) dm?3) in a submerged membrane bioreactor (sMBR) is described. The chemical oxygen demand (COD) of raw whey varied in the range of 60 and 90 g dm?3. After feeding the sMBR with raw whey, effluent COD reduced to about 20 g dm?3. The effluent was free of suspended solids and total coliform bacteria. Total phosphorus (TP) and orthophosphate (Ortho‐P) in the influent varied between 204 and 880 mg dm?3 and between 180 and 620 mg dm?3, and effluent TP and Ortho‐P reduced to 113 and 109 mg dm?3, respectively. The ammonium and nitrate concentrations in the influent were in the ranges of 3.4 and 120 mg dm?3 and 10 and 503 mg dm?3, respectively. The effluent ammonium concentration varied between 17.6 and 198 mg dm?3 and nitrate concentrations varied between 0.9 and 69 mg dm?3. Effluent turbidity varied between 23 and 111 FAU (Formazin Attenuation Unit). The results show that sMBR is an effective pre‐treatment system for high‐strength agro‐wastewaters because of its ability to reduce the pollution load. Copyright © 2004 Society of Chemical Industry  相似文献   

17.
The high concentration of biodegradable constituents in waste-water derived from bagasse-based paper mills warrants the consideration of an anaerobic biotechnology process to recover biogas and reduce the pollution load. An anaerobic down-flow fixed-film bark reactor process was studied to treat waste-water generated from bagasse-based paper mills. At the anaerobic stage, 90–95% of the total chemical oxygen demand (COD) was removed at loading rates of 3–18 kg COD m%?3 day%?1 without supplying any nutrients or trace elements. A yield coefficient of 0.156 g cells (g COD) %?1 was calculated at a high COD loading rate of 18 kg COD m%?3 day%?1. With the anaerobic treatment process it is estimated that 1 m3 of bagasse waste-water with a COD content of 13000 mg dm%?3 can produce about 3.5 m3 of methane. Intermittent checks on the system alkalinity revealed that feed neutralization to maintain alkalinity would be necessary with sodium bicarbonate at approximately 2500 mg dm%?3 for achieving steady-state high treatment efficiency.  相似文献   

18.
The performance of a laboratory‐scale anaerobic acidogenic fermenter fed with a mixture of blended kitchen food‐waste and primary sludge from a sewage treatment plant was investigated for the production of volatile fatty acids (VFA). The operating variables for acidogenic fermentation were kitchen food‐waste content (10 and 25 wt %), hydraulic retention time (HRT: 1, 3 and 5 days), temperature (ambient: 18 ± 2 °C, and mesophilic: 35 ± 2 °C) and pH (varied from 5.2 to 6.7). The experimental results indicated that effluent VFA concentrations and VFA production rates were higher at ambient temperature than at mesophilic conditions. The net amount of VFA with 10 wt % food‐waste increased up to 920 mg dm?3 with an increase of HRT, but contrasting results (a decrease of 2610 mg dm?3) were found due to the conversion of VFA into biogas in the case of 25 wt % food‐waste, which increased significantly at HRT of 3–5 days. In terms of biogas composition (CO2 and CH4), the organic matter was converted into CO2 through the oxidative pathway by facultative species at low temperature while mesophilic temperature and optimum pH (6.3–7.8) played a pivotal role in increasing rate of conversion of VFA into biogas by methanogenesis. Rates of VFA production and their conversion are dependent on the food‐waste content in the mixture. Yet, the higher concentration of food‐waste (25% compared with 10%) did not produce VFA proportionally due to the increased rate of conversion of VFA into gaseous products. The maximum VFA production rate (0.318 g VFAproduced g?1 VSfed day?1) was achieved in the 10 wt % food‐waste at ambient temperature and at a 5‐day HRT. Copyright © 2005 Society of Chemical Industry  相似文献   

19.
The laboratory scale anaerobic–anoxic–aerobic (A2O) process fed with synthetic brewage wastewater was designed to investigate the effects of changing feed C/P ratio on the performance of biological nutrient removal (BNR) processes. In the experiment, the influent chemical oxygen demand (COD) concentration was kept at approximately 300 mg L?1 while the total phosphorus concentration was varied to obtain the desired C/P ratio. Results showed that when the C/P ratio was lower than 32, phosphorus removal efficiency increased as C/P ratio increased linearly, while when the C/P ratio was higher than 32, the P removal efficiency was maintained at 90–98%, and effluent P concentration was lower than 0.5 mg L?1. However, regardless of the C/P ratio, excellent COD removal (90% or higher) and good total nitrogen removal (75–84%) were maintained throughout the experiments. It was also found that very good linear correlation was obtained between COD uptake per unit P released in the anaerobic zone and C/P ratio. In addition, the P content in the wasted activated sludge increased with the decrease in the C/P ratio. Based on the results, it was recommended that the wastewater C/P ratio and its effects be incorporated into BNR design and operational procedures, appropriate C/P ratios were used to achieve the effluent treatment goals. Copyright © 2005 Society of Chemical Industry  相似文献   

20.
ABSTRACT

This study has evaluated the efficiency of Fenton process followed by coagulation to treat real effluent from fish farm. Fenton obtained Chemical Oxygen Demand and turbidity removal of 48% at (0.5 mg L?1 Fe2+ and 10 mmol H2O2). Fenton followed by coagulation reduced COD and turbidity by almost 100%. The process also decreased the concentrations of suspended solids, phosphate, nitrate, Biological Oxygen Demand, and nitrite. Ecotoxicology test indicated that the effluent treated with 0.5 mmol L?1 Fe2+ in 10 mmol L?1 H2O2 displayed the lowest toxicity. These findings can indicate an environmental friendly alternative to treat fish farm effluent.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号