首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
This study evaluates the bond strength of four self‐etching adhesive systems with different acidity levels in normal and artificially hypermineralized dentin substrate. Healthy human molars were divided into groups: normal dentin—N (n = 36) and artificially hypermineralized dentin—H (n = 36). Self‐etching adhesive systems Clearfil S3 Bond (n = 9), Optibond All in One (n = 9), Clearfil SE Bond (n = 9), and Adhese (n = 9) were used for both the N and H groups. Transparent cylindrical matrices were positioned on the treated dentin surfaces, filled with composite resin, and light‐cured for 40 s. After the transparent cylindrical matrices were removed, the specimens were stored for 24 hr in a humid environment at 37°C and were subjected to a micro‐shear bond strength test. For each group, a specimen was prepared and evaluated in scanning electron microscope for adhesive interface observation. Normality was confirmed and the two‐way analysis of variance and Games–Howell post‐tests were conducted (α = .05). The data demonstrated an interaction between the adhesive system and type of dentin substrate (p < .01). For normal dentin, all adhesive systems assessed were adequate; however, in the hypermineralized dentin, the Clearfil SE Bond two‐step self‐etching adhesive system with mild pH presented the highest immediate bond strength. There was a predominance of adhesive failures for all adhesive systems in the different dentin substrates evaluated. It was concluded that the self‐etching adhesive systems evaluated were efficient for both substrates, and for the hypermineralized dentin, the Clearfil SE Bond presented a higher bond strength value.  相似文献   

2.
This study evaluated the effects of an antioxidant application on the compromised bond strength of an adhesive to dentin bleached with 35% hydrogen peroxide. The dentin surfaces of the pulp chambers of 70 human third molars were ground, and the specimens were assigned randomly into seven groups, as follows: (a) control (unbleached); (b) bleached for 45 min, bonded immediately; (c) bleached for 45 min, treated with sodium ascorbate (SA) for 2 min, and bonded; (d) bleached for 45 min, bonded after 2 weeks; (e) bleached for 12 days, bonded immediately; (f) bleached for 12 days, treated with SA for 10 min, and bonded; and (g) bleached for 12 days, bonded after 2 weeks. In each group, the multimode adhesive was applied in etch‐and‐rinse and self‐etch modes. The dentin surfaces were covered with a resin‐based composite, and the bonded specimens were sectioned to produce composite–dentin sticks. The sticks were attached to a testing machine and subjected to a tensile force, and the representative specimens were examined via scanning electron microscopy. The bond strength was not affected by the application period of the bleaching agent. Both bleaching treatments significantly reduced the bond strength to the dentin in the self‐etch or etch‐and‐rinse mode when compared with the control group. The bond strengths returned to normal levels with the SA applications or by waiting 2 weeks, regardless of the application period of the bleaching gel. The adhesive revealed a higher bond strength in the etch‐and‐rinse mode than in the self‐etch mode.  相似文献   

3.
The objective of this study was to analyze the dentin‐resin cements interfacial ultramorphologies using two different methods: scanning (SEM) and transmission electron microscopy (TEM). Four commercial products were evaluated: two conventional cementing system (RelyX ARC/Adper? Scotchbond? Multi‐Purpose Plus, 3M ESPE and Clearfil Esthetic Cement/DC Bond, Kuraray) and two self‐adhesive resin cements (RelyX Unicem, 3M ESPE and Clearfil SA Cement, Kuraray). Prepolymerized resin disks (Sinfony, 3M ESPE) were cemented on oclusal dentin surfaces of 24 third human molars, simulating the indirect restorations. After 24 h, teeth were sectioned into 0.9‐mm thick slabs and processed for microscopy analyses (SEM or TEM/ n = 3). Qualitative characterization of dentin‐resin cement interface was performed. Hybrid layer formation with long and dense resin tags was observed only for RelyX ARC cementing system. Clearfil Esthetic Cement/DC Bond system revealed few and short resin tags formation, whereas no hybridization and resin tags were detected for self‐adhesive resin cements. Some interfacial regions exhibited that the self‐adhesive resin cements were not bonded to dentin, presenting bubbles or voids at the interfaces. In conclusion, TEM and SEM bonding interface analyses showed ultramorphological variations among resin cements, which are directly related to dental bonding strategies used for each resin cement tested. Microsc. Res. Tech. 76:1234–1239, 2013. © 2013 Wiley Periodicals, Inc.  相似文献   

4.
The aim of this in‐vitro study was to evaluate microtensile bond strength (μTBS) of two different self‐adhesive composites (SACs) on the permanent dentin by applying five different universal adhesive systems. In this study, two different SACs [Vertise Flow (VF), Fusio Liquid Dentin (FLD)] and five different bonding systems [Clearfil Universal Bond Quick (CUB), Single Bond Universal (SBU), All Bond Universal (ABU), Prime Bond Universal (PBU), Futurabond U (FBU)] were used. A total of 22 groups were created in which SACs were applied without adhesive and with five different universal bonding agents in total‐etch (TE) and self‐etch (SE) modes. Two hundred and forty test sticks were obtained using 48 healthy human molar teeth in total with groups having 10 samples each. The μTBS test was applied to each sample in the Universal test device and the data obtained were analyzed statistically by variance analysis and Tukey HSD test. In addition, the resin–dentin interface and fractures modes in the groups were examined by SEM. Upon examining the μTBS results, the highest values were seen in the use of SBU adhesive in TE mode in VF group, while the lowest values were seen in the FLD control group. The difference between the control and experimental groups was found statistically significant (p < .05). Upon comparing the control groups with each other, it was seen that VF group had higher μTBS values than FLD group and the difference between the groups was found statistically significant (p < .05). The μTBS results and SEM images of the study showed that the use of SACs with universal adhesive systems provides a more effective bond strength.  相似文献   

5.
Aim: Evaluate the composite‐to‐enamel bond after passive or active application of self‐etching primer systems on polished or pre‐etched enamel with phosphoric acid. Materials and Methods: Two self‐etch adhesives systems (SEAS) were used: Clearfil SE Bond and Easy Bond. Third human molars were divided into 8 groups (N = 10). The crown of each tooth was sectioned into halves and the mesial/distal surfaces were used. The adhesives were actively or passively applied on enamel with or without prior phosphoric‐acid etching. Resin composite cylinders were built after adhesive application. After stored in relative humidity for 24 hr/37°C the specimens were subjected to microshear test in universal testing a machine at a crosshead speed of 0.5 mm/minute. The results were analyzed with three‐way ANOVA and the Tukey test. The enamel‐etching pattern was evaluated under SEM. Results: The 2‐step SEAS system presented significantly higher adhesive bond strength means (47.37 MPa) than the 1‐step (36.87 MPa). A poor enamel‐ etching pattern was observed in active mode showing irregular and short resin tags, however there was not compromised the bond strength. Conclusion: Active or passive application produced similar values of bond strength to enamel regardless of enamel pretreatment and type of SEAS.  相似文献   

6.
This study evaluated the effect of 10% sodium hypochlorite (NaOCl) as deproteinizing agent and storage media on bond strength (BS) of two etch‐and‐rinse adhesive systems to dentin. Twenty‐eight sound extracted human third molars were divided in four groups (n = 7), according to dentin treatment (conventional etching or etching followed by 10% NaOCl application) and adhesive systems (GB—Gluma 2Bond and OS—One‐Step). After dentin treatments and adhesive application, a composite block was built‐up on dentin surface and teeth were serially sectioned to obtain bonded sticks specimens. The sticks were submitted to three aging conditions: (24H) 24 hr in water (immediate), (SH) 3 hr of NaOCl accelerated‐aging or (1Y) 1 year of water storage. Afterward, submitted to microtensile bond strength test (μTBS), failure modes and adhesive interfaces analyzes. Data were analyzed by two‐way analysis of variance (ANOVA) and Tukey's test (α = .05). Dentin deproteinization before bonding significantly reduced μTBS for GB‐treated group (p < .05), regardless the aging conditions. Water storage for 1 year (1Y) and NaOCl accelerated‐aging (SH) decreased μTBS for both adhesives. Yet, the groups stored in NaOCl (SH) exhibited the lowest BS results (p < .05). Bond strength of deproteinized dentin was dependent on the adhesive system composition and NaOCl accelerated‐aging promoted decreased bond strength and further degradation than water storage for 1 year.  相似文献   

7.
This study evaluated dentin bond strength (BS) and nanoleakage of non‐ and pre‐etched dentin immediately (T0,), 7 days (T7), and 14 days (T14) after bleaching. Bovine incisors (150) were selected and half of them submitted to intrapulpal dentin etching (e). Non‐ and pre‐etched dentin were subjected to the following (n = 15): no bleaching/control (C); 35% carbamide peroxide (CP); 35% hydrogen peroxide (35% HP); 25% hydrogen peroxide (25% HP); and sodium perborate (SP). Bleaching agents were applied to the pulp chamber four times within a 72‐h interval. Afterwards, pulp chamber dentin was prepared for the BS test at different evaluation times (n = 5): T0, T7, and T14. Composite blocks were built on pulp chamber and sectioned in slices. Slices were reduced to an hour‐glass shape with a cross‐sectional area of 0.8 mm2 and submitted to microtensile BS test. Two additional specimens for each group were prepared for nanoleakage evaluation by transmission electron microscopy (TEM). Results were analyzed by ANOVA (two‐way) and Dunnett's test (p < .05). BS decreased immediately after intracoronal bleaching for both sound and pre‐etched dentin (p < .05). At T14, the BS of non‐etched bleached dentin increased for all groups, whereas the pre‐etched SPe group presented BS similar to the Ce. Nanoleakage within the hybrid layer was perceptible immediately after bleaching, although a decrease in nanoleakage was observed for all groups at T14. Adhesive restorations should be performed 7–14 days after bleaching, according to the bleaching agent used. Intracoronal bleaching should be performed preferably with sodium perborate if previous dentin etching is applied.  相似文献   

8.
Preservation of enamel during composite veneer restorations of fluorosed teeth could be achieved by conservative preparation with Erbium lasers. This study evaluated the effect of fluorosed enamel preparation with Er,Cr:YSGG vs. conventional diamond bur on the micromorphology and bond strength of a self‐etch and an etch‐and‐rinse adhesives. Er,Cr:YSGG laser or diamond bur preparation was performed on the flattened midbuccal surfaces of 70 extracted human premolars with moderate fluorosis (according to Thylstrup and Fejerskov index, TFI = 4–6). Adper Single Bond (SB) with acid etching for 20 or 40 s and Clearfil SE Bond (SEB) alone or with additional etching was applied in four laser groups. The same adhesive procedures were used in three bur groups except for 40 s of etching along with SB. After restoration, microshear bond strength was measured (MPa). Data were analyzed using ANOVA and Tamhane tests (α = 0.05). Six additional specimens were differently prepared and conditioned for scanning electron microscopy evaluation. The highest and lowest bond strengths were obtained for bur‐prepared/SB (39.5) and laser‐prepared/SEB (16.9), respectively, with a significant difference (P = 0.001). The different adhesive procedures used associated to two adhesives exhibited insignificantly lower bonding in laser‐prepared groups compared to bur‐prepared ones (P > 0.05), with the exception of additional etching/SEB, which bonded significantly higher to bur‐prepared (36.4) than to laser‐prepared enamel (18.7, P = 0.04). Morphological analyses revealed a delicate etch pattern with exposed enamel prisms on laser‐prepared fluorosed enamel after acid etching and less microretentive pattern after self‐etching primer. The etch‐and‐rinse adhesive was preferred in the laser‐prepared fluorosed enamel in terms of bonding performance. Microsc. Res. Tech. 77:779–784, 2014. © 2014 Wiley Periodicals, Inc.  相似文献   

9.
Oxalate‐based products are effective against dentine sensitivity and have been studied as an option to improve long‐term adhesive bonding strength. Our aim was to evaluate the effect of potassium oxalate on the microtensile bond strength (µTBS) of the dentin/resin interface after 24 h, 1, and 6 years. Dentin on the occlusal surface of 16 human premolars was exposed and etched with 35% phosphoric acid. The teeth were divided into four groups. Two groups received 3% monohydrated potassium oxalate and the following adhesive systems and composites: Adper Scotchbond Multipurpose + FiltekZ350 (3M/ESPE) and Prime & Bond NT + Esthet‐X (Dentsply). Two control groups did not receive potassium oxalate. Teeth were cut into sticks and kept in distilled water at 37°C for 24 h, 1, and 6 years. The sticks underwent µTBS testing after storage. ANOVA, Tukey's post hoc test, and paired t test were used to compare storage times (α = 0.05). The fracture mode of the specimens was classified under a stereomicroscope (40×). Morphology of the hybrid layer and the fracture pattern were observed with scanning electronic microscopy (SEM). Mean µTBS was high at 24 h and decreased after 1 and 6 years. After 6 years, the mean µTBS values were similar with no statistically significant difference between the groups (p = .121). SEM images showed proper dentin hybridization. Dentin pretreatment with potassium oxalate did not affect hybrid layer formation, but bond strength decreased over time after 24 h. Therefore, the clinical use of potassium oxalate to increase dentin bond durability is not indicated.  相似文献   

10.
Purpose: The aim of this study was to evaluate the nanoleakage patterns between dental enamel and reinforced leucite ceramic, bonded with resin luting systems and a flowable composite resin. Materials and Methods: Twelve crowns of bovine incisors were randomly divided into four groups (n = 3) according to the luting procedure: Excite/Variolink II, Clearfil SE Bond/Panavia F, Scotchbond Multi‐Purpose Plus/RelyX ARC, and Single Bond 2/Filtek Z350 Flow. To evaluate the nanoleakage patterns, IPS Empress Esthetic disks (5 mm Ø and 1.2‐mm thick) were bonded to enamel, and, after 24 h, the specimens were immersed in a 50% (w/v) solution of silver nitrate (24 h), fixed, dehydrated, and processed scanning electron microscopy (SEM). Results: None nanoleakage on interface of the groups that Single Bond 2 followed by the flowable composite were used. The highest percentage of nanoleakage was shown by the Excite/Variolink II protocol. Also, in all conditions tested, none silver nitrate uptake was observed between the leucite‐reinforced ceramic and the resin luting cement. Conclusions: The use of a two‐step etch‐and‐rinse adhesive with flowable composite was able to promote an adequate seal of the bond interface at the enamel. Moreover, the conventional dual‐cured resin cements associated with simplified and dual‐cured adhesives tested are also indicated to bond thin ceramics to enamel, since all presented low silver nitrate uptake. Microsc. Res. Tech., 2012. © 2011 Wiley Periodicals, Inc.  相似文献   

11.
Universal adhesives have been recently introduced for use as self‐etch or etch‐and‐rinse adhesives depending on the dental substrate and clinical condition. However, their bonding effectiveness to laser‐irradiated enamel is still not well‐known. Thus, the aim of this study was to compare the shear bond strength (SBS) of universal adhesives (Single Bond Universal; Nova Compo‐B Plus) applied to Er,Cr:YSGG laser‐irradiated enamel with SBS of the same adhesives applied in self‐etch and acid‐etching modes, respectively. Crown segments of sixty bovine incisors were embedded into standardized acrylic blocks. Flattened enamel surfaces were prepared. Specimens were divided into six groups according to universal adhesives and application modes randomly (n = 10), as follows: Single Bond Universal/acid‐etching mode; Nova Compo‐B Plus/acid‐etching mode; Single Bond Universal/self‐etching mode; Nova Compo‐B Plus/self‐etching mode; and Single Bond Universal/Er,Cr:YSGG Laser‐etching mode; Nova Compo‐B Plus/Er,Cr:YSGG Laser‐etching mode. After surface treatments, universal adhesives were applied onto surfaces. SBS was determined after storage in water for 24 h using a universal testing machine with a crosshead speed of 0.5 mm min?1. Failure modes were evaluated using a stereomicroscope. Data was analyzed using two‐way of analyses of variances (ANOVA) (p = 0.05). Two‐way ANOVA revealed that adhesive had no effect on SBS (p = 0.88), but application mode significantly influenced SBS (p = 0.00). Acid‐etching significantly increased SBS, whereas there are no significant differences between self‐etch mode and laser‐etching for both adhesives. The bond strength of universal adhesives may depend on application mode. Acid etching may significantly increase bond strength, while laser etching may provide similar bond strength when compared to self‐etch mode.  相似文献   

12.
An effective and stable bond is the most desirable characteristic of contemporary adhesive systems. The aim of this study was to evaluate the effect of potassium oxalate on dentin/resin bond strength. Dentin on the occlusal surface of human premolars was exposed and etched with 35% phosphoric acid, to receive 3% monohydrated potassium oxalate and the following adhesive systems: Scotchbond Multipurpose (SMO; 3M/ESPE) and Prime & Bond NT (PBO; Dentsply), followed by the application of resin composite (Z250; 3M/ESPE). The control groups (SM and PB) did not receive potassium oxalate application. The prepared teeth were kept in distilled water at 37°C for 24 h and 12 months. They were then cut longitudinally into sticks with a bond area of ~0.8 mm(2) for submission to the microtensile bond strength test. The data were analyzed by two-factor ANOVA, Tamhane's paired comparisons, and the Student t-test (α = 0.05). The hybrid layer formed was observed by scanning electron microscopy (SEM). SEM analysis of the surfaces treated with PB revealed shorter resin tags associated with the application of potassium oxalate, whereas SM showed tags similar to those without potassium oxalate. A significant difference was shown between the two storage times for each of the protocols. There was a significant difference among SMO, SM, and PBO (24 h), as well as among SM, SMO, and PBO, and between PB and PBO (12 months). The application of potassium oxalate before conventional adhesive systems may result in alteration of the bond strength between dentin and resin composite, depending on the material.  相似文献   

13.
The purpose of this in vitro study was to evaluate the interaction pattern of adhesive systems on laser and bur cavities. Cavities were prepared according to the following groups (n=9): (G1) conventional diamond bur (No. 1013); (G2) Er:YAG laser (250 mJ, 4 Hz, 80.6 J/cm2); (G3) Er,Cr:YSGG laser (3.5 W, 20 Hz, 61.7 J/cm2). After cavity preparation, specimens were divided into three subgroups differing the adhesive systems used (n=3): (GA) AdheSE; (GB) Clearfil standard error (SE) Bond; (GC) Single Bond. After insertion of a micro-hybrid composite resin, the specimens were sectioned across the bonded surface dividing the teeth into two halves, which were prepared for SEM analysis. Cavities prepared with laser appeared to be more irregular than the bur cavities. Different patterns of gap formation and resin tags could be observed, showing the differences, advantages, and disadvantages of both types of cavities. Under the settings of the present study, resin tags were more pronounced in lased dentin than bur prepared dentin independently of the bonding systems used. On the other hand gap formation between dentin and resin in laser prepared cavities was observed suggesting collagen alteration.  相似文献   

14.
In the present research, different adhesive techniques were used to set up fillings with composite resins. After the application of etch and rinse or self etch adhesive technique, marginal adaptation of composite fillings was estimated by the length of margins without gaps, and by the microretention of resin in enamel and dentin. The study material consisted of 40 extracted teeth. Twenty Class V cavities were treated with 35% phosphorous acid and restored after rinsing by Adper Single Bond 2 and Filtek UltimateASB/FU 3M ESPE composite system. The remaining 20 cavities were restored by Adper Easy OneAEO/FU 3M ESPE composite system. Marginal adaptation of composite fillings was examined using a scanning electron microscope (SEM). The etch and rinse adhesive technique showed a significantly higher percentage of margin length without gaps (in enamel: 92.5%, in dentin: 57.3%), compared with the self‐etch technique with lower percentage of margin length without gaps, in enamel 70.4% (p < .001), and in dentin‐22.6% (p < .05). In the first technique, microretention was composed of adhesive and hybrid layers as well as resin tugs in interprismatic spaces of enamel, while the dentin microretention was composed of adhesive and hybrid layers with resin tugs in dentin canals. In the second technique, resin tugs were rarely seen and a microgap was dominant along the border of restoration margins. The SEM analysis showed a better marginal adaptation of composite resin to enamel and dentin with better microretention when the etch and rinse adhesive procedure was applied.  相似文献   

15.
Nanofillers are added to dental adhesives to improve mechanical properties of the hybrid layer. Ethanol or water added to the demineralized dentin to improve adhesive infiltration may produce filler aggregation. OBJECTIVE: To assess the effect of 5 vol% water or ethanol addition on nanoparticles distribution in dental adhesives. METHODS: Six available commercial adhesives systems were selected: Clearfil SE Bond (CSE), Clearfil Protect Bond (CPB), FL‐Bond (FLB), Clearfil S3 (CS3), Bond Force (BF), One Up Bond F plus (OUB), and an experimental adhesive system without filler (EXP). Polymer films were obtained by adding 0 (control) or 5 vol% water or ethanol into the bonding resins. Preparations were light‐cured (40 s). Three specimens were analyzed for each mixture. Three phases and 3D images were taken from each specimen by means of an atomic force microscope in taping mode (TM/AFM). Cluster sizes and surface nanoroughness were assessed. RESULTS: Control specimens from CSE, FLB, OUB, and BF presented clusters. The addition of solvents lead to particles aggregation in tested bonding resins. Ethanol addition produced more aggregates, particularly in adhesives containing fluoraluminosilicate as fillers. CONCLUSIONS: Nanofillers aggregation occurred in all adhesive systems in presence of additional solvents. In general, aggregate sizes were higher after the addition of ethanol. Formed clusters size values are always above the dimensions of the spaces existing between the demineralized collagen fibers. Microsc. Res. Tech. 75:749–757, 2012. © 2011 Wiley Periodicals, Inc.  相似文献   

16.
This study evaluates the bond strength of dentin prepared with Er:YAG laser or bur, after rewetting with chlorhexidine on long‐term artificial saliva storage and thermocycling. One hundred and twenty human third molars were sectioned in order to expose the dentin surface (n = 10). The specimens were randomly divided in 12 groups according to treatment and aging: Er:YAG laser rewetting with deionized water (LW) and 24 h storage in artificial saliva (WC); LW and 6 months of artificial saliva storage + 12.000 thermocycling (6M), LW and 12 months of artificial saliva storage + 24.000 thermocycling (12M), Er:YAG laser rewetting with 2% chlorhexidine (LC) and WC, LC and 6M, LC and 12M, bur on high‐speed turbine rewetting with deionized water (TW) and WC, TW6M, TW12M, bur on high‐speed turbine + 2% chlorhexidine (TC) and WC, TC and 6M, TC and12M. The specimens were etched with 35% phosphoric acid, washed, and dried with air. Single Bond 2 adhesive was applied and the samples were restored with a composite. Each tooth was sectioned in order to obtain 4 sticks, which were submitted to microtensile bond strength test (µTBS). The two‐way ANOVA, showed no significant differences for the interaction between the factors and for the aging factor. Tukey 5% showed that the LC group had the lowest µTBS. The rewetting with chlorhexidine negatively influenced the bond strength of the preparation with the Er:YAG laser. The artificial saliva aging and thermocycling did not interfere with dentin bond strength. Microsc. Res. Tech. 77:37–43, 2014. © 2013 Wiley Periodicals, Inc.  相似文献   

17.
The erbium:yttrium–aluminum–garnet (Er:YAG) laser may be effective the bond strength of adhesive systems on dentine surfaces, the chemical composition and aggressiveness of adhesive systems in clinical practice. The purpose of this study was to evaluate the effects of the Er:YAG laser system with the bonding ability of two different self‐etching adhesives to caries‐affected dentine in primary molars. Ninety mid‐coronal flat dentine surfaces obtained from sound and caries‐affected human primary dentine were treated with an Er:YAG laser or a bur. The prepared surfaces were restored with an adhesive system (Xeno V; Clearfil S3) and a compomer (Dyract Extra). The restored teeth were sectioned with a low‐speed saw and 162 samples were obtained. The bond strength of the adhesive systems was tested using the micro‐tensile test method. The data were statistically analyzed. A restored tooth in each group was processed for scanning electron microscopy evaluation. The values of the highest bond strength were obtained from the Clearfil S3‐Er:YAG laser‐sound dentine group in all groups. (24.57 ± 7.27 MPa) (P > 0.05). The values of the lowest bond strength were obtained from the Xeno V‐Er:YAG laser‐sound dentine group in all groups (11.01 ± 3.89 MPa). It was determined that the Clearfil S3 increased the bond strength on the surface applied with Er:YAG laser according to the Xeno V. Microsc. Res. Tech. 77:282–288, 2014. © 2014 Wiley Periodicals, Inc.  相似文献   

18.
19.
This study focused on adhesive interface morphologic characterization and nanoleakage expression of resin cements bonded to human dentin pretreated with 1% chlorhexidine (CHX). Thirty‐two non‐carious human third molars were ground flat to expose superficial dentin. Resin composite blocks were luted to the exposed dentin using one conventional (RelyX ARC) and one self‐adhesive resin cement (RelyX U100), with/without CHX pretreatment. Four groups (n = 8) were obtained: control groups (ARC and U100); experimental groups (ARC/CHX and U100/CHX) were pretreated with 1% CHX prior to the luting process. After storage in water for 24 h, the bonded teeth were sectioned into 0.9 × 0.9 mm2 sticks producing a minimum of 12 sticks per tooth. Four sticks from each tooth were prepared for hybrid layer evaluation by scanning electron microscope analysis. The remaining sticks were immersed in silver nitrate for 24 h for either nanoleakage evaluation along the bonded interfaces or after rupture. Nanoleakage samples were carbon coated and examined using backscattered electron mode. Well‐established hybrid layers were observed in the groups luted with RelyX ARC. Nanoleakage evaluation revealed increase nanoleakage in groups treated with CHX for both resin cements. Group U100/CHX exhibited the most pronouncing nanoleakage expression along with porous zones adjacent to the CHX pretreated dentin. The results suggest a possible incompatibility between CHX and RelyX U100 that raises the concern that the use of CHX with self‐adhesive cements may adversely affect resin‐dentin bond. Microsc. Res. Tech. 76:788–794, 2013. © 2013 Wiley Periodicals, Inc.  相似文献   

20.
Previous studies have shown the effects of Er,Cr:YSGG laser irradiation on the dentin bond strength; but there are few reports that show the significance of the irradiation with different laser parameters on dentin bond strength and interface morphology. This in‐vitro study attempted to evaluate the microtensile bond strength (μTBS) and interface morphology of resin‐dentin interfaces, either followed by treatment with Er,Cr:YSGG laser irradiation with different parameters or not. The flattened dentin samples of 35 bovine teeth were embedded into acrylic blocks and randomly divided into seven groups according to surface treatments using Er,Cr:YSGG lasers with different parameters: 3 W/20 Hz, 3 W/35 Hz, 3 W/50 Hz, 1.5 W/20 Hz, 1.5 W/35 Hz, 1.5 W/50 Hz, or no laser treatment (n = 5). Composite buildups were done over bonded surfaces and stored in water (24 hours at 37°C). Specimens were sectioned into sticks that were subjected to μTBS testing and observed under FE‐SEM. Control groups (27.70 ± 7.0) showed statistically higher values than laser‐irradiated groups. There were no significant differences among laser groups. Despite that, increasing the pulse frequency yielded slightly higher bond strength. Depending on laser settings, Er,Cr:YSGG laser irradiation caused interfacial gaps and resin tags with wings morphology. With the parameters used in this study, Er,Cr:YSGG laser irradiation promoted morphological changes within resin‐dentin interfaces and negatively influenced the bond strength of adhesive systems. Microsc. Res. Tech. 78:1104–1111, 2015. © 2015 Wiley Periodicals, Inc.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号