Abstract Five floors of a 20-year old 6-story office building were investigated using an integrated step-by-step investigation strategy. This involved a walkthrough inspection, an occupant questionnaire, and targeted environmental monitoring of indoor air quality and comfort parameters. The initial questionnaire survey revealed a high occurrence of building-related symptoms. The walkthrough inspection and environmental monitoring identified deposits of surface dust (indoor surface pollution – ISP) on carpets and hard surfaces, and elevated levels of carbon dioxide and respirable suspended particulate matter (RSP) throughout the building. An intervention study (blinded to the occupants) was targeted at reducing ISP levels by replacing normal carpet cleaning practices with higher performance vacuum cleaners and improved cleaning practices. The intervention reduced ISP levels and significantly lowered RSP concentrations by approx. 80% from initial values and against control floors. A follow-up SBS questionnaire revealed significant reductions in all but two of the symptoms. The most significant reductions occurred with symptoms of eye irritation, throat irritation, dry unproductive cough, and nose irritation. The study showed that in older buildings with poor ventilation, a build-up of ISP, and elevated RSP levels, using higher performance carpet cleaning practices can reduce RSP to acceptable levels and can reduce SBS symptoms.  相似文献   

2.
Zuraimi MS 《Indoor air》2010,20(6):445-457
Ventilation duct cleaning (DC) is widely advocated to provide good indoor air quality (IAQ), health benefits, cost savings, and enhance ventilation system performance. The aim of the present review is to evaluate the scientific evidence as shown in the literature. There is evidence that under normal operating conditions, ventilation ducts can be contaminated with dusts and serve as reservoirs for microbials to proliferate. While controlled experiments noted that contaminants resuspension can elevate exposure levels indoors, no field studies have correlated poor IAQ with duct contamination. Despite high efficiencies of contaminant removal within the ducts during cleaning, reductions for different indoor air pollutants vary widely, where, post-cleaning air pollutants concentrations can be higher than pre-cleaning levels. Further, there are health concerns in the use of biocides, sealants and encapsulants. There is inadequate evidence to show that DC can improve airflow in ducts and reduce energy consumption. Although epidemiological studies indicate suggestive evidence that improperly maintained ducts are associated with higher risks of symptoms among building occupants, this review finds insufficient evidence that DC can alleviate occupant's symptoms. In summary, the need for duct cleanliness has to be properly balanced by the probable generation of indoor pollution resulting from DC and subsequent potential health risks. PRACTICAL IMPLICATIONS: Existing evidence is insufficient to draw solid conclusions regarding positive impact of duct cleaning on IAQ, health benefits, cost savings and HVAC performance. Maintaining duct cleanliness has to be properly balanced by the probable generation of indoor pollution and potential health risks.  相似文献   

3.
In two case-referent studies the associations between questionnaire symptom reports, expressed as SBS (Sick Building Syndrome) in office workers or facial skin symptoms among VDT-workers, and physical data from offices in 160 buildings were investigated. The results show that low outdoor airflow rate and presence of certain pollution sources, such as copying machines, tended to be associated with an elevated prevalence of SBS. Buildings built or remodeled between 1977 and 1986, low-rise buildings with a horizontal roof and a foundation of the type “concrete slab on the ground”, as well as rooms with flourescent tube lighting with metal shields were also associated with higher SBS risks. A number of factors were associated with an overrepresentation of skin symptoms among VDT-workers such as type of foundation (concrete slab on the ground and crawlspace), the frequency of floor cleaning and type of lighting (fluorescent tubes with glass/plastic shields). It has not been possible to establish conclusive explanations for these associations. The difference in associations between building factors and S B S, and between building factors and skin symptoms among VD Tworkers points to different etiologies.  相似文献   

4.
There are few longitudinal studies on sick building syndrome (SBS), which include ocular, nasal, throat, and dermal symptoms, headache, and fatigue. We studied the associations between selected microbial components, fungal DNA, furry pet allergens, and incidence and remission of SBS symptoms in schools in Taiyuan, China. The study was based on a two-year prospective analysis in pupils (N = 1143) in a random sample of schools in China. Settled dust in the classrooms was collected by vacuum cleaning and analyzed for lipopolysaccharide (LPS), muramic acid (MuA), and ergosterol (Erg). Airborne dust was collected in Petri dishes and analyzed for cat and dog allergens and fungal DNA. The relationship between the concentration of allergens and microbial compounds and new onset of SBS was analyzed by multi-level logistic regression. The prevalence of mucosal and general symptoms was 33% and 28%, respectively, at baseline, and increased during follow-up. At baseline, 27% reported at least one symptom that improved when away from school (school-related symptoms). New onset of mucosal symptoms was negatively associated with concentration of MuA, total LPS, and shorter lengths of 3-hydroxy fatty acids from LPS, C14, C16, and C18. Onset of general symptoms was negatively associated with C18 LPS. Onset of school-related symptoms was negatively associated with C16 LPS, but positively associated with total fungal DNA. In general, bacterial compounds (LPS and MuA) seem to protect against the development of mucosal and general symptoms, but fungal exposure measured as fungal DNA could increase the incidence of school-related symptoms.  相似文献   

5.
Abstract Insufficient cleaning may be a cause of the Sick Building Syndrome. Various improvements in cleaning methods have been tested in order to clarify whether they reduced the concentration of airborne dust, and the concentration of dust on surfaces, or whether the concentration of different microbiological components in the dust was reduced. The interventions were performed in an administration building, a school and a kindergarten. Dust measurements were performed on one day every week for a period of 28 weeks, using different interventions. The airborne dust concentration was measured by sampling on filters during the day. The concentration of surface dust was measured by the BM-Dustdetector foil sampling method. Dust samples were collected from the floors, after which analyses for different microbiological components were performed. Sampling from surfaces and the floor were performed prior to cleaning in order to ascertain the levels to which the room occupants had been exposed. One of the findings was a reduction in the dust concentration on the so-called easily accessible surfaces. Correlations between surface dust and airborne dust were also found. Furthermore, correlations between the measurements and other factors, such as activity during the day, and the climate, were obtained. Important findings of the study were the observations made on the relations between cleaning and dust in the indoor environment and the measuring methods applied.  相似文献   

6.
This study was performed to explore possible environmental risk factors, including indoor chemicals, mold, and dust mite allergens, which could cause sick building syndrome (SBS)-type symptoms in new houses. The study was conducted in 2004 and 2005 and the final study population consisted of 86 men and 84 women residing in Okayama, Japan. The indoor concentrations of indoor aldehydes, volatile organic compounds, airborne fungi, and dust mite allergens in their living rooms were measured and the longitudinal changes in two consecutive years were calculated. A standardized questionnaire was used concomitantly to gather information on frequency of SBS-type symptoms and lifestyle habits. About 10% of the subjects suffered from SBS in the both years. Crude analyses indicated tendencies for aldehyde levels to increase frequently and markedly in the newly diseased and ongoing SBS groups. Among the chemical factors and molds examined, increases in benzene and in Aspergillus contributed to the occurrence of SBS in the logistic regression model. Indoor chemicals were the main contributors to subjective symptoms associated with SBS. A preventive strategy designed to lower exposure to indoor chemicals may be able to counter the occurrence of SBS.  相似文献   

7.
The purpose of the study was to evaluate the impact of cleaning on indoor environment quality. Surface dust contamination and occupants' perception of the work environment factors and symptoms were the parameters studied. Six multi-floor office buildings were selected. Dust contamination on surfaces was sampled with gelatine foils and quantified using a BM-Dustdetector. Occupants' perceptions of the environment were assessed with modified MM-40 questionnaires. The results indicated that each building had its own surface dust contamination profile. Weekly cleaning maintained the surface dust contamination at the highest acceptable level for indoor environments. The occupants and their activities have a major effect on the level of dust particle contamination on desks. The correlation between the perceived surface dust contamination and the level of satisfaction with cleaning was as expected. Furthermore, surface dust contamination appeared not to be associated with work-related symptoms. PRACTICAL IMPLICATIONS: The results provide information about current program for contractors and clients, e.g. appropriate cleaning intervals of different surfaces, and the influence of disorder on result. After the evaluation of surface dust contamination levels, it will be possible for cleaning companies to focus on the most important surfaces to clean in order to enhance the quality of the indoor environment in office buildings. This should lead to future development work, which will require cooperation between contractors, clients, and research scientists. In office environments where high cleanliness is required, objective measurements (with instruments) are needed in addition to subjective measurements (the perceptions of occupants). It is essential to evaluate the efficiency of cleaning programs regularly with effective and appropriate quality-monitoring methods.  相似文献   

8.
Abstract Perceived air quality, Sick Building Syndrome (SBS) symptoms and productivity were studied in an existing office in which the air pollution level could be modified by introducing or removing a pollution source. This reversible intervention allowed the space to be classified as either non-low-polluting or low-polluting, as specified in the new European design criteria for the indoor environment CEN CR 1752 (1998). The pollution source was a 20-year-old used carpet which was introduced on a rack behind a screen so that it was invisible to the occupants. Five groups of six female subjects each were exposed to the conditions in the office twice, once with the pollution source present and once with the pollution source absent, each exposure being 265 min in the afternoon, one group at a time. They assessed the perceived air quality and SBS symptoms while performing simulated office work. The subject-rated acceptability of the perceived air quality in the office corresponded to 22% dissatisfied when the pollution source was present, and to 15% dissatisfied when the pollution source was absent. In the former condition there was a significantly increased prevalence of headaches (P= 0.04) and significantly lower levels of reported effort (P=0.02) during the text typing and calculation tasks, both of which required a sustained level of concentration. In the text typing task, subjects worked significantly more slowly when the pollution source was present in the office (P=0.003), typing 6.5% less text than when the pollution source was absent from the office. Reducing the pollution load on indoor air proved to be an effective means of improving the comfort, health and productivity of building occupants.  相似文献   

9.
Two kinds of air duct cleaning methods, mechanical brushing with different brushes and compressed air cleaning, were compared in the laboratory and in newly built buildings. The ducts were contaminated either with test dust or with dust originated from a construction site. The amount of dust on the duct surface was measured with the vacuum test method and estimated visually before and after the cleaning. In addition, the cleaning times of the different techniques were compared and the amount of residual oil in the ducts was measured in the laboratory test. The brushing methods were more efficient in metal ducts, and compressed air cleaning was more efficient in plastic ducts. After the duct cleaning the mean amount of residual dust on the surface of the ducts was 相似文献   

10.
袋式除尘器是目前最高效的锅炉烟气净化治理设备之一,清灰是袋式除尘器长期稳定运行的关键,清灰影响因素众多,复杂多变。本文总结归纳国内外关于过滤介质清灰过程的研究状况,主要从清灰机理、清灰影响因素、过滤介质的清灰过程实验及其数值模拟研究等方面进行分析,为袋式除尘器的优化设计提供参考。  相似文献   

11.
Abstract Recent concern has centered on “sick buildings” in which there has been an unusually high percentage of health complaints by the building's occupants. Typically, these symptoms are thought to be tied to indoor air quality characteristics, such as high levels of respirable particles or volatiles, thermal conditions, etc. In addition, recent studies have drawn connections between “sick building syndrome” (SBS) symptoms and non-environmental variables, i.e., personal and occupational factors. This paper presents a brief review of a study by Hedge et al. (1995) and additional analyses of their data. In a study of 27 air-conditioned office buildings, Hedge et al. measured nine indoor environmental conditions at various locations within each building and concurrently questioned workers on sixteen SBS symptoms and a number of other personal factors. The additional analyses presented in this paper attempt to draw formal statistical connections between SBS symptoms and both personal worker characteristics and indoor air pollutants simultaneously. The analyses were based on symptom severity response variables whic include information not only on the frequency with which an individual experienced a symptom, but also on how much the symptom disrupted the individual's work. Results from sixteen linear mixed effects models indicate that significant predictors are primarily personal and occupational in nature rather than environmental. For a number of the symptoms, additional variability attributable to buildings exists. However, any physical explanation of this variability remains unclear.  相似文献   

12.
A random sample of 1000 subjects (20-65 years of age) received a postal questionnaire regarding sick building syndrome (SBS), including the three-dimensional model of demand-control-support (DCS). The response rate was 70% (n = 695), and 532 were occupationally active. Female gender and atopy were the main predictors of symptoms. Eye symptoms were more common at low social support combined with strained work situation [odds ratio (OR) 2.37], and at high social support combined with active work situation (OR 3.00). Throat symptoms were more common at low social support combined with either passive (OR 1.86) or strained situation (OR 2.42). Tiredness was more common at low social support combined with either passive (OR 2.41), strained (OR 2.25), or active situation (OR 1.87), and at high social support combined with active work situation (OR 1.83). Low social support combined with either passive (P = 0.01) or strained job situation (P = 0.01) was associated with a higher symptom score (SC). The lowest SC was found at a relaxed work situation, irrespective of social support. In conclusion, female gender, low age, asthma, atopy and psychosocial work environment are associated with symptoms. The three-dimensional model can predict symptoms compatible with SBS, but in a more complex way than earlier research indicated. Practical Implications A multi-disciplinary approach, including psychosocial stress factors as well as personal factors such as gender, age, atopy and asthma, and indoor exposures, should be applied in studies on symptoms compatible with sick building syndrome (SBS). Males and females perceive psychosocial work conditions differently, and may react differently to job stressors. The psychosocial work environment can be as important as gender and atopy as a predictor of SBS symptoms.  相似文献   

13.
Increasing evidence shows that certain personality traits, such as negative affectivity (trait NA), are strongly associated with the reporting of symptoms. The role of personality in sick building syndrome (SBS) symptom reporting is therefore explored with the aid of a questionnaire completed by occupants living in apartments with indoor climate problems. A good fit to empirical data was obtained for a path model in which somatization intervenes between a general psychological factor (predominated by trait NA) and SBS. Occupants with "normal" and "aberrant" NA profiles were classified by cluster analysis and further divided according to frequency of symptoms. For occupants with 5 or more SBS symptoms, those with "aberrant" NA profiles have very similar SBS symptom profiles to those with "normal" NA profiles. This indicates that an occupant's trait NA score cannot be used for predicting his or her SBS symptom profile or frequency of SBS symptoms. An unexpected finding was that the occupants with "aberrant" NA profiles also perceived factors in the indoor (air) environment as less adverse than the 5 or more symptom reporting occupants with "normal" NA profile. Pennebaker and Brittingham's competition of external and internal cues model may explain the results for the occupants with "aberrant" NA profiles, however, our empirical data indicate that, unexpectedly, these occupants may not over-report SBS symptoms but rather under-report adverse environmental perceptions.  相似文献   

14.
This study investigated the possible relationships between exposures to mite allergen and airborne fungi with sick building syndrome (SBS) symptoms for residents living in newly built dwellings. We randomly sampled 5709 newly built dwellings in six prefectures from northern to southern Japan. A total of 1479 residents in 425 households participated in the study by completing questionnaire surveys and agreeing to environmental monitoring for mite allergen (Der 1), airborne fungi, aldehydes, and volatile organic compounds. Stepwise logistic regression analyses adjusted for confounders were used to obtain odds ratios (OR) of mite allergen and fungi for SBS symptoms. Der 1 had a significantly high OR for nose symptoms. Rhodotorula had a significantly high OR for any symptoms, and Aspergillus had significantly high OR for eye symptoms. However, the total colony-forming units had a significantly low OR for throat and respiratory symptoms. Eurotium had a significantly low OR for skin symptoms. In conclusion, dust-mite allergen levels and indoor airborne Rhodotorula and Aspergillus concentrations may result in SBS symptoms in newly built dwellings. PRACTICAL IMPLICATIONS: Various factors can cause sick building syndrome symptoms. This study focused on biologic factors such as dust-mite allergen and airborne fungi in newly built dwellings in Japan. Dust-mite allergen levels were significantly associated with higher rates of nose symptoms, airborne Rhodotorula concentrations were significantly associated with higher rates of any symptoms, and Aspergillus concentrations were significantly associated with higher rates of eye symptoms. Measures should be taken to reduce mite allergen levels and fungal concentrations in these dwellings.  相似文献   

15.
提出了一种墙面环保清理机的设计,实现了墙面装饰层等清理机械化.本清理机主要用于室内墙面的装饰层清理和打磨,解决了传统手工打磨费工费时,安全性低,粉尘污染等缺点.它不仅成本低,操作维护方便,而且清理效率高,无粉尘污染.  相似文献   

16.
Abstract Concentrations of volatile organic compounds (VOCs) measured indoors may exceed their odor thresholds, but are usually far below TLV estimates. Even applying additivity to eye and airway irritation effects, it is difficult to rationalize increased sick building syndrome (SBS) symptoms by exposure to generally chemically inert VOCs in the indoor environment. Several studies suggest that chemical reactions in indoor air are linked with SBS symptoms and the examination of these reactions may be necessary in order to understand the role of VOCs as causative agents of SBS symptoms. The usual evaluation of odor annoyance of VOCs based on odor thresholds should be modified, taking into account the large variation of individual human odor thresholds for single substances, and specific additivity phenomena even at subthreshold levels of VOCs. The conclusion of this review is that chemical reactions between oxidizable VOCs and oxidants, such as ozone and possibly nitrogen oxides, can form irritants which may be responsible for the reported symptoms. Compounds adsorbed to particles may also contribute to SBS symptoms. The individual effects of indoor pollutants may act in concert with temperature and relative humidity. New analytical methods are required to measure the oxidative and reactive species or specific markers thereof in indoor air.  相似文献   

17.
Endotoxin exacerbates asthma. We designed the Louisa Environmental Intervention Project (LEIP) and assessed its effectiveness in reducing household endotoxin and improving asthma symptoms in rural Iowa children. Asthmatic school children (N = 104 from 89 homes) of Louisa and Keokuk counties in Iowa (aged 5-14 years) were recruited and block-randomized to receive extensive (education + professional cleaning) or educational interventions. Environmental sampling collection and respiratory survey administration were done at baseline and during three follow-up visits. Mixed-model analyses were used to assess the effect of the intervention on endotoxin levels and asthma symptoms in the main analysis and of endotoxin reduction on asthma symptoms in exploratory analysis. In the extensive intervention group, dust endotoxin load was significantly reduced in post-intervention visits. The extensive compared with the educational intervention was associated with significantly decreased dust endotoxin load in farm homes and less frequent nighttime asthma symptoms. In exploratory analysis, dust endotoxin load reduction from baseline was associated with lower total asthma symptoms score (Odds ratio: 0.52, 95% confidence interval: 0.29-0.92). In conclusion, the LEIP intervention reduced household dust endotoxin and improved asthma symptoms. However, endotoxin reductions were not sustained post-intervention by residents.  相似文献   

18.
提出把空气净化装置主要设于回风口以拒尘、菌的主动式污染控制理念和方法,得出这样的装置必需具备三个必要条件:初阻力不大于20Pa,滤菌效率不小于90%,除尘计重效率不小于95%(或对于粒径大于等于0.5μm微粒的计数效率不小于70%)。  相似文献   

19.
The effects of mechanical ventilation on the sick building syndrome (SBS) were studied in an office building with 2150 employees, where the mechanical ventilation and indoor air quality were commonly blamed for causing symptoms typical of the SBS (nasal, eye, and mucous membrane symptoms, lethargy, skin symptoms and headache). The mechanical ventilation rates in the building were high (mean 26 l/s/person). To test the hypothesis that mechanical ventilation causes the SBS, a controlled experimental study was carried out by shutting off the ventilation in one part of the building and reducing the ventilation rate by 75% and 60% in two areas while leaving one part unaltered as a control. The experimental reduction of the ventilation rate did not alleviate the symptoms. On the contrary, the reduction of the ventilation rate caused a slight but statistically significant relative increase in symptoms (p < 0.05). In the cross-sectional analysis of the baseline data the SBS symptoms did not associate significantly with the ventilation rate (range 7–70 l/s/person). In the linear regression model, a positive correlation was found between temperatures above 22°C and the occurrence of symptoms (p < 0.05). Subjects exposed to environmental tobacco smoke had more symptoms than those not exposed (p < 0.01). Women reported more symptoms than men (p < 0.001). In addition, any prior history of allergic diseases (p < 0.001) and a negative attitude towards the social atmosphere at work (p < 0.001) were significant determinants of the SBS.  相似文献   

20.
《Planning》2018,(5)
Street dust is a carrier of various pollutants widely distributed in the urban road environment, and has obvious particle size effect on environmental pollution. In this paper, the effects of particle size distribution on dust accumulation, heavy metal pollution and cleaning conditions are mainly discussed. Based on the particle size effect of street dust, the future research and control of non-point source pollution are given a breakthrough.  相似文献   