首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
戴娅楠  王宗成 《影像技术》2004,(3):49-50,56
CR系统在骨与关节、软组织的x线诊断中已广泛应用。笔者就膝关节常规正、侧位进行三组曝光,并与铝梯做对应测试研究。同时利用CR系统的信息处理,论证曝光条件与影像密度谐调的辩证关系。  相似文献   

2.
直接数字射线照相合理应用探讨   总被引:1,自引:0,他引:1  
直接数字射线照相DDR,有时被简称直接射线照相(Direct Radiography),或数字射线照相(Digital Radiography),是最近几年发展起来的新成像技术,它有别于采用IP成像板捕获射线影像的计算机射线照相CR,需要经过模数转换,而是采用一种由非晶形硅或硒阵列构成的平板探测器捕获影像,经电路输出数字化的光电信号,直接形成数字化影像,具有成像速度快、图像清晰、照射剂量少、操作简便等优点。本文阐述其安装和使用方面的实际经验和体会。  相似文献   

3.
王延福  赵毅 《影像技术》2009,21(1):53-54
目的:探讨老年性膝关节骨性关节病的临床及影像学诊断。方法:分析368例老年性膝关节骨性关节病的临床资料、影像学表现及手术结果。结果:老年性膝关节骨性关节病发生于中、老年人,包括骨性关节炎和滑膜骨软骨瘤病。全部患者均有关节骨质退变增生;其中关节间隙变窄、关节面硬化280例,约占76.1%;关节受力轴线改变、关节畸形158例,约占42.9%;关节游离体存在136例,约占37.0%。结论:老年性膝关节骨性关节病是一种复杂的复合性疾病,以放射检查为依据,CT和MRI检查明确病变的程度,为临床制定治疗方案提供依据。  相似文献   

4.
王骏 《影像技术》2002,(1):44-46
本文简明扼要地综述了胸部X摄影技术近些年来研究开发的一些新成果,阐述其所能达到的诊断水平和优缺点,包括:非对称性医用X线胶片的屏-片组合系统、多束均锋X线摄影、各种荧光存贮X线摄影系统等。  相似文献   

5.
LDRD-01BD32kw型数字X射线机操作简单,灵敏度高,直接数字成像。扫描时间较短,图像质量符合临床诊断要求,是常规X射线机辐射剂量的1/100。图像信息易为诊断医师会诊阅读。可以数字化存储,通过网络远程传送。  相似文献   

6.
医学直接数字摄影是以专用的计算机控制射线摄影系统进行拍摄,并把摄取的(X线影像)信息数字化,再通过图像再现或复制系统形成X线摄影图像。本文对近几年来用数字摄影系统拍摄的胸部X线摄影图像与用传统的屏片法的图像进行了临床对比评价和分析。  相似文献   

7.
李衍 《影像技术》2005,(1):52-54
概述和简析三种数字射线照相技术的基本特点和方法要点,凸现其相对于传统的胶片法射线照相技术的各种优点,并展示其在工业上的应用前景,期盼该新技术在国内迅速推广。  相似文献   

8.
王骏  陈堤 《影像技术》1999,(3):13-15
本文总结了胸部射线摄影一些成就突出的新数字成像系统的近年进展情况,如:基于荧光储存系统的数字射线摄影、硒探测器系统、即时减影技术等,并提出了对配套应用的几种监视器的评价。  相似文献   

9.
目的:探讨肋骨骨折的临床表现、体征及数字化摄影的方法、体位,提高肋骨骨折的显示及检出率,解决肋骨骨折的误诊、漏诊问题。方法:对胸廓外伤病人行数字化摄影检查,采用正、侧位、仰卧前后位、不同角度斜位摄片等方法,诊断肋骨骨折并与常规摄片诊断结果进行对比分析。结果:多体位数字化摄片,不仅大大提高了肋骨骨折的检出率,而且以其清晰的图像直观地显示肋骨骨折的部位及数目,为临床诊断及司法鉴定提供了科学的依据。结论:胸部多体位数字化摄像以其明显的优势,科学可靠的诊断结果,较好的解决了肋骨骨折的误诊、漏诊问题。  相似文献   

10.
直接数字化X线摄影技术   总被引:2,自引:0,他引:2  
数字X线摄影是指利用电子计算机数字化潜能与常规X线摄影及装置相组合,将其X线信息转换成数字形式,经后处理成像的方法。 直接数字X线摄影是在上述基础上省略信息采集中的中间传递环节,具有成像快,影像质量高的特征。 本文对直接数字化成像技术的特点、构造、工作原理、影像质量等进行概述。  相似文献   

11.
工业非胶片射线照像技术 一.射线实时成像   总被引:1,自引:1,他引:0  
李衍 《影像技术》2010,22(1):29-34
传统的工业胶片射线照相正受到数字射线照相的严重挑战。射线照相图像的探测器从胶片到图像增强器,从荧光体成像板到非晶硅和非晶硒成像板,再到阵列探测器,射线检测系统从硬件到软件在不断翻新,工业射线检查的效率和可靠性也在不断提高。采用与计算机结合的非胶片射线照相技术,能大大减少曝光时间,缩短检测周期,还可以完全避免由胶片冲洗引起的环境污染,而且射线照相影像便于存档、检索、远程传递和评定。本文系列介绍有关这方面的新技术。  相似文献   

12.
在图像有线传输的基础上,研究便携式无线射线图像采集传输处理系统.对其进行改造,提出射线图像信号的无线传输的设计方法.实验证明该系统的图像传输质量和通过有线传输的图像传输质量一样,但传输距离增加了一倍.  相似文献   

13.
刘铁  魏世栋  王宗成 《影像技术》2011,23(5):26-27,20
从传统X线摄影到计算机X线摄影(Computed Radiography,cR)再到数字X线摄影(Digital Radiography,DR),历经了百年的发展,成像过程在不断的演变,但它们都已X线作为成像源的本质并没有改变。无论何种成像方法所获得的被照体影像,虽其成像过程中的影响因素不尽相同,但其照片质量的评价标准应为一致。本文将X线摄影过程中的工作体会与质控活动中的实践经验相结合,归纳出X线摄影中照片质量控制的要点,希望对我们今后的实际工作有所帮助,最终得到不但满足临床诊断需求,而且完全符合质控标准的优秀的照片影像。  相似文献   

14.
Radiography by selective detection (RSD), was investigated for its ability to determine the presence and types of defects in a UO2 fuel rod surrounded by zirconium cladding. Images created using a Monte Carlo model compared favorably with actual X-ray backscatter images from mock fuel rods. A fuel rod was modeled as a rectangular parallelepiped with zirconium cladding, and pencil beam X-ray sources of 160 kVp (79 keV avg) and 480 kVp (218 keV avg) were generated using the Monte Carlo N-Particle Transport Code (MCNP) to attempt to image void and palladium (Pd) defects in the interior and on the surface of the fuel pellet. It was found that the 160 kVp spectrum was unable to detect the presence of interior defects, whereas the 480 kVp spectrum detected them with both the standard and the RSD backscatter methods, though the RSD method was very inefficient. It was also found that both energy spectra were able to detect void and Pd defects on the surface using both imaging methods. Additionally, two mock fuel rods were imaged using a backscatter X-ray imaging system, one consisting of hafnium pellets in a Zircaloy-4 cladding and the other consisting of steel pellets in a Zircalloy-4 cladding which was then encased in a steel cladding (a double encapsulation configuration employed in irradiation and experiments). It was found that the system was capable of detecting individual HfO2 pellets in a Zircaloy-4 cladding and may be capable of detecting individual steel pellets in the double-encapsulated sample. It is expected that the system would also be capable of detecting individual UO2 pellets in a Zircaloy-4 cladding, though no UO2 fuel rod was available for imaging.  相似文献   

15.
介绍了计算机化 X光影象仪 ( Computerized Radiography,CR)的基本组成及其特点 ,论述了 CR系统中 X光图象数据采集的方法及技术指标 ,并以硬件和软件相结合的方法 ,实现了对 X光图象数据的实时采集和存储 ,经长时间的实验表明该方法是可行的 ,完全满足技术指标要求。  相似文献   

16.
李衍 《影像技术》2006,(5):38-41,31
介绍工业数字射线照相提高钢焊缝中微小缺陷检测灵敏度的新途径:利用微焦点X射线源+高灵敏探测器+最佳投影放大率,能陵其IQI(像质计)灵敏度、影像对比度和空间分辨率,达到等价于甚至优于常规ISO T3类射线胶片的效果。  相似文献   

17.
计算机X线摄影(CR)后处理技术在颈椎常规摄影中的应用   总被引:1,自引:0,他引:1  
目的:评价计算机X线摄影(CR)后处理技术在颈椎常规摄影中的应用价值。方法:随机选取50例颈椎正、侧位CR片,并经密度仪测得标准测试点的密度值,观察其是否分布在胶片特性曲线的直线部分。结果:所测得的标准测试点的密度值均投影在胶片特性曲线的直线部分。结论:经过CR系统处理的颈椎正、侧位片完全符合诊断要求,并可满足不同的临床诊断需求。  相似文献   

18.
目的 研究射线图像中保持细节的滤噪方法 .方法 依据图像中噪声的特点 ,提出三种去噪方法 ,即差分梯度法、邻域比较法、σ滤波与邻域比较相结合 .结果 采用这些方法对射线图像进行处理 ,有明显的去噪效果 ,且保持细节 .结论 这些方法对于图像滤噪具有普遍意义 ,特别对于含有微小细节、颗粒脉冲噪声的图像更适合  相似文献   

19.
计算机X线摄影成像板与体模间隙效应(Groedel法)研究   总被引:1,自引:0,他引:1  
目的:X线与被照体相互产生散射线,散射线因其特性会损害照片影像质量,增加被检者皮肤X线人射剂量,破坏生物细胞。对散射线必须进行制改。方法:在计算机X线摄影中增加体模与成像板的间隔,利用石蜡球,选择标定的曝光条件,测试出最佳的间距。结果:通过激试、研究、分析,证实间隔在20-30cm时,达到在高于伏摄影下,不使用法线栅,控制散射线量,验证了照片质量。结论:计算机X线摄影成像板与体模间隔效应(Groedel法)对降低散射线、提高空间分辨力,减少照射剂量。在影像医学检查中意义大,且实用。  相似文献   

20.
目前,由新的成像技术稀土元素成像板(IP)、数字化处理技术和干法硬拷贝印片设备组成的CR放射成像系统已经在我国医疗系统广泛应用,本文通过其在泌尿系统临床中的实际应用,并与常规屏片照相方法对比,探讨其应用价值和体现其突出的优越性,如:减少病人接受的射线剂量、造影质量更好、提高影像的清晰度、尤其是软组织的反差和层次及分辨率,从而提高显示病灶的能力和诊断的准确率等等。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号