首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 625 毫秒
1.
Zn-doped TiO2 catalysts were prepared using a sol-gel method and characterized by XPS,UV-Vis, BET, XRD in this study. Under the irradiation of simulant sunlight, the photocatalytic activity for the degradation of p-nitrophenol was studied too. After irradiation for 2.5 h, the degradation percentage of p-nitrophenol could rise to more than 80 %. The results showed that the spectrum absorption band edge of Zn/TiO2 powder does not broaden obviously comparing with pure TiO2 powder. Zinc exists as Zn (11). When calcined at 973 K, there is a new phase as ZnTiO3 in Zn/TiO2 catalyst. The order of photocatalytic activity of Zn/TiO2 catalysts calcined at different temperatures for p-nitrophenol is 773 K 〉 673 K 〉 873 K 〉 573 K 〉 973 K and the photocatalytic activity of Zn/TiO2 catalyst calcined at 773 K is better than TiO2 catalysts heated at the same temperature, and outclasses that of commercial TiO2 catalyst. It also showed that the photocatalytic degradation of p-nitrophenol follows first-order kinetics under the irradiation of simulant sunlight.  相似文献   

2.
Radiotherapy for the treatment of prostate cancer has been extensively explored in the past. Along with the comprehensive understanding of the biology of prostate cancer and rapid advances in terms of technology, the out- come of treatment for the patients with prostate cancer has improved. The authors review radiotherapy as the primary treatment for the disease, with particular emphasis on the technological advances from both the radiobiological and radiophysics aspects. Nonconventional fractionated irradiation like hyper- or hypo-fractionation has been imple- mented in the clinic, the final results still need to be confirmed in the future. Technological advances like IMRT, IGRT, in the last two decades have significantly improved the delivery of external radiotherapy to the prostate. This has re- sulted in an overall increase in the total dose that can be safely delivered to the prostate, which has led to modest im- provements in the biochemical outcome. However, establishing the standard therapy for prostate cancer remains con- troversial. It is hoped that the next decades will bring continued advances in the development of biologicals that will further improve current clinical outcomes.  相似文献   

3.
This paper introduces the injection and extraction control system design for SSRF,which is a distributed control system aimed at stability and reliability of the pulse power supplies,PPS(Personnel Protection System)and MPS(Machine Protection System).The hardware environment is mainly based on PLC(Programmable Logic Con- troller),and ARM(Advanced RISC Machine)is also applied for studying stability of the power supplies.WinCC and EPICS(Experimental Physics and Industrial Control System)have been selected as the platforms of SCADA(Super- visory Control and Data Acquisition).For unifying the interfacing to the control computer,all front-end equipments are connected via Industrial Ethemet.  相似文献   

4.
为研究含空气蒸汽在水平管内强制对流冷凝换热特性,基于对传热传质过程的分析,建立了管内为环状流与波状流条件下的流动冷凝换热模型。从潜热、显热和液膜3个环节对整个换热过程进行建模,最终得到计算局部冷凝换热系数的理论关系式。模型预测结果与实验数据的对比表明,二者相对偏差在±20%以内,验证了该换热模型的准确性与适用性。通过进一步的研究发现:从换热管入口至出口,随着冷凝的进行,管内换热主要热阻由液膜热阻向气液界面的凝结热阻转变;主流气体对流换热过程基本可忽略。  相似文献   

5.
为对自制的活性面积高达1 000 cm2的大面积源进行表面发射率定值,同时作为现有2πα、2πβ表面发射率标准装置能力的扩充,研制了一套内置式大面积2π多丝正比计数器测量系统,并利用活性区直径为8 mm的241Am点源及活性区面积为10 cm×15 cm的大面积241Am和90Sr-90Y源对其进行计量学性能测试。结果表明:计数器内计数响应均匀性优于±0.4%,有效探测面积达1 400 cm2;所得241Am源高压坪曲线的坪长为1 400 V,坪斜为0.27%/100 V,坪区内计数变化为0.87%;90Sr-90Y源高压坪曲线的坪长为300 V,坪斜为0.75%/100 V,坪区内计数变化为0.80%;10次测量重复性好于0.4%,8 h内短期稳定性好于0.3%,1 a内长期稳定性好于0.8%。  相似文献   

6.
Experiments were carried out to investigate the possible use of neutron backscattering for the detection of polyethylene (PE) sample buried in the soil. In detection of landmine by neutrons, the neutron detector and its shield play an important role. In this paper, the effects of graphite, heavy water, polyethylene and boric acid moderators on the flux of back scattered neutrons were investigated. We have also experimentally verified the effect of BF3 detector shield and obtained good agreement with theory.  相似文献   

7.
Accelerator database stores various static parameters and real-time data of accelerator. SSRF (Shanghai Synchrotron Radiation Facility) adopts relational database to save the data. We developed a data retrieval system based on XML Web Services for accessing the archive data. It includes a bottom layer interface and an interface applicable for accelerator physics. Client samples exemplifying how to consume the interface are given. The users can browse, retrieve and plot data by the client samples. Also, we give a method to test its stability. The test result and performance are described.  相似文献   

8.
Distributions of natural gamma-emitting radionuclides were determined in 93 oil samples collected from some petroleum fields in the western desert of Egypt. The radioisotope activities in the area under investigation lay in the range of (21 ± 4) to (38 ± 13) Bq?L-1 for 226Ra, (9 ± 2) to (15 ± 5) Bq?L-1 for 232Th, and (154 ± 28) to (303 ± 54) Bq?L-1 for 40K. The mean values were 27, 12, and 201 Bq?L-1, respectively. Among oils, variations in radionuclide ac- tivities could be on account of differences in TDS, HCO3, and Ba, with high or low pH. In this environment, oil prop- erties differently affected the mobilization of natural radionuclides. The range of 226Ra variation had been compared with available data from other countries. The calculated absorbed dose rate ranged from 22.33 to 32.66 nGy?h-1 in lo- cation (B) and (E) respectively, which was less than the accepted value.  相似文献   

9.
In this work,TTHMP was synthesized and labelled with 117m Sn.The preparation conditions,stability and lipophilicity of 117m Sn(IV)-TTHMP were investigated.Biodistribution of the complex in rabbits and mice was studied.It was found that the quantity of TTHMP and pH value of the prepararion solution had vital effects on the labeling yield of 117m Sn(IV)-TTHMP.It was also found that 117m Sn(IV)-TTHMP was hydrophilic and stable at room temperature and 37℃ in open air 117m Sn(IV)-TTHMP showed unexpectedly high bone uptake and bone-to-blood ratio in the animals.This made it potentially useful as an reagent for skeletal scintigraphy and radiotherapy of bone tumors.  相似文献   

10.
Monitoring results of gamma dose rate level in 1992~2004 in the ambient environment of the Qinshan Nuclear Power Plants(QNPP)Base,the northeast of Zhejiang Province,are reported in this paper.It is shown that the gamma dose rate of five monitoring sites of 2.5 km to QNPP Base is 84~113 nGy/h,with an average of 96 nGy/h in the 13 years.The average value is close to the background level of 93 nGy/h prior to operation of the QNPP Base,and is lower than the monitoring result of 101 nGy/h at the reference site in Hangzhou City.Within 50 km from the QNPP Base,the cumulative dose rate of the thermoluminescent dosimeter(TLD)is 90 nGy/h,which is lower than the back- ground level of 111 nGy/h.  相似文献   

11.
The adsorption behaviors of uranium on three soil humic acids (HAs), which were extracted from soils of different depths at the same site, were investigated under various experimental conditions. The adsorption results showed that U(Ⅵ) in solutions can be adsorbed by the three soil HAs, with the order of FHA (HA from 5 m depth of soil) >SHA (HA from the surface) >THA (HA from 10 m depth of soil) for adsorption efficiency in each desirable condition, and the adsorption reached equilibrium in about 240 min. Although the maximum adsorption efficiency was adsorption could be described with Langmiur isotherm or Freundlich isotherm equation. The L/S (liquid/solid, mL/g)ratio and pH were important factors influencing the adsorption in our adsorption system besides uranium concentration. The adsorption efficiency decreased with the increase of the L/S ratio and pH at the pH range of 2.0-3.0 for SHA and THA or 2.5 - 6.0 for FHA. However, no significant difference in adsorption of U(Ⅵ) was observed at the experimental temperature. All the results implied that humic substances have different characteristics in samples even collected at the same site.  相似文献   

12.
Linear accelerators equipped with multileaf collimators (MLC) are becoming more common and are widely used in the intensity-modulated radiotherapy (IMRT). There is an imperative need to ensure the commissioning specification of the linear accelerators for the sake of quality assurance (QA) and quality control (QC). This paper is aimed to investigate the role of AGFA high-energy CR (Computed Radiography) in calibrating dynamic multileaf collimators and evaluating the accuracy of the leaf position. The result shows that AGFA high-energy CR can easily and conveniently be used to calibrate MLC and verify its position. Hence, the application of AGFA high-energy CR is proved to be an accurate and time-saving method for routine MLC QC, especially when MLC calibration adjustments are required.  相似文献   

13.
14.
<正>1.NUCLEAR SCIENCE AND TECHNIQUES(NST),a bimonthly journal,is devoted to all aspects of nuclear science and technology,theoretical or experimental.Its special interest lies in the subjects of synchrotron radiation science and technology;low energy accelerators,radiation technology and appli-  相似文献   

15.
<正>1.NUCLEAR SCIENCE AND TECHNIQUES(NST),a bimonthly journal,is devoted to all aspects of nuclear science and technology,theoretical or experimental.Its special interest lies in the subjects of synchrotron radiation science and technology;low energy accelerators,radiation technology and applications;radiochemistry,radiopharmaceuticals and nuclear medicine;nuclear electronics and instrumentation;interdisciplinary studies of  相似文献   

16.
《等离子体科学和技术》2014,16(9):I0002-I0002
Plasma Science and Technology (PST) is a journal reporting novel experimental and theoretical results and progress of interdisciplinary and application sciences in the fields related to Plasma Physics. Specific interested areas include: basic plasma phenomena; magnetically confined plasma; inertially confined plasma; astrophysics and space plasma; low temperature plasma; plasma technology and fusion engineering.  相似文献   

17.
The hydrogen deflagration is one of the major risk contributors to threaten the integrity of the containment in a nuclear power plant, and hydrogen control in the case of severe accidents is required by nuclear regulations. Based on the large dry containment model developed with the integral severe-accident analysis tool, a small-break loss-of-coolant-accident (LOCA) without HPI, LPI, AFW and containment sprays, leading to the core degradation and large hydrogen generation, is calculated. Hydrogen and steam distribution in containment compartments is investigated. The analysis results show that significant hydrogen deflagration risk exits in the reactor coolant pump (RCP) compartment and the cavity during the early period, if no actions are taken to mitigate the effects of hydrogen accumulation.  相似文献   

18.
抗振条面内接触刚度对蒸汽发生器传热管流致振动的影响   总被引:1,自引:1,他引:0  
流弹性失稳是引起蒸汽发生器传热管管束失效的一种主要原因。在相同流场条件下,传热管是否出现流弹性失稳与其模态频率直接相关。在实际结构中,抗振条对U型传热管弯管段面内支撑机理与面外的方向上不同,是通过摩擦约束实现的。这使得在模态分析计算中,传热管弯管段支撑处的边界条件设置非常重要。本文将传热管与抗振条接触点处的面外边界条件假设为简支,而在面内方向上用弹簧来模拟抗振条对传热管的摩擦约束。同时,通过改变弹簧刚度,讨论了不同强弱的面内支撑对传热管流致振动的影响。分析结果表明,当抗振条与传热管面内接触刚度较弱时,面内流弹性失稳可能较面外流弹性失稳出现得更早。  相似文献   

19.
为研究微型X射线管的特性,通过电离室测量光管出射口30 cm远处的空气比释动能,使用高纯锗探测器分别测量了Ag过滤和Cu过滤下的X射线能谱。结果表明,空气比释动能随电流的增加有线性增加的趋势,能谱图明显的观察到银的两个特征X射线。完成了微型X射线管空气比释动能和能谱的测量方法以及实验测量的工作,为微型x射线管下辐射质的建立提够了条件基础。  相似文献   

20.
《核技术(英文版)》2014,(5):F0003-F0003
<正>1.NUCLEAR SCIENCE AND TECHNIQUES(NST),a bimonthly journal,is devoted to all aspects of nuclear science and technology,theoretical or experimental.Its special interest lies in the subjects of synchrotron radiation science and technology;low energy accelerators,radiation technology and applications;radiochemistry,radiopharmaceuticals and nuclear medicine;nuclear electronics and instrumen-  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号