首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 156 毫秒
1.
为了研究内置型钢桁架高强混凝土中高剪力墙的抗震性能,采用不同的暗柱类型及不同的暗柱和暗支撑型钢配钢率,设计制作了3片1/4缩尺、剪跨比1.8、混凝土强度等级为C70的内置型钢桁架高强混凝土中高剪力墙试件,对其进行水平往复加载试验,比较3片高强混凝土中高剪力墙试件的受力过程、破坏形态、滞回性能、位移延性以及侧向刚度退化特征。试验结果表明:内置型钢桁架高强混凝土中高剪力墙试件的最终破坏形态主要为弯曲型破坏,相比于普通高强混凝土中高剪力墙,其位移延性以及后期侧向刚度退化都有明显改善;增加暗柱型钢配钢率能提高试件的水平承载力,但会降低延性性能;增加暗支撑型钢配钢率能显著改善试件的延性,但承载力变化不明显,说明型钢暗支撑对改善高强混凝土中高剪力墙的抗震性能更为有效。  相似文献   

2.
通过对3个1/4缩尺、剪跨比为1.0的内置型钢桁架高强混凝土低剪力墙试件进行拟静力试验,研究其在低周反复荷载作用下的抗震性能.分析了不同暗柱型钢类型及暗支撑型钢配钢率对试件破坏形态、滞回曲线、骨架曲线、位移延性以及侧向刚度退化的影响.采用有限元软件ABAQUS对试件进行数值模拟.结果表明:内置型钢桁架高强混凝土低剪力墙试件具有弯曲破坏的特征,试件的位移延性与普通高强混凝土低剪力墙相比有明显提高、后期侧向刚度退化曲线更加平缓,说明内置型钢桁架提高其抗震性能的有效性;暗柱型钢及暗支撑型钢配钢率对试件的受剪承载力影响不明显,但对位移延性以及滞回耗能影响显著,当暗支撑相同时,暗柱型钢配钢率提高,试件的受剪承载力有所提高;暗柱型钢相同时,暗支撑型钢配钢率提高能显著提高试件的位移延性和滞回耗能能力.ABAQUS数值模拟结果与试验结果吻合较好.  相似文献   

3.
内藏钢桁架组合中高剪力墙的抗震性能   总被引:1,自引:1,他引:0  
为了研究内藏钢桁架组合中高剪力墙的抗震性能,进行了6个1/3缩尺的中高剪力墙低周反复荷载试验,其中包括2个普通混凝土剪力墙、2个内藏钢框架混凝土剪力墙和2个内藏钢桁架混凝土剪力墙,轴压比分别是0.2、0.5。在试验研究基础上,对比分析了两种轴压比下各剪力墙的承载力、刚度、延性、滞回特性、耗能能力及破坏特征。试验及分析表明:在不同轴压比下,内藏钢桁架混凝土组合中高剪力墙的抗震性能比普通混凝土中高剪力墙的抗震性能显著提高;高轴压比下各剪力墙的承载力比低轴压比下相应剪力墙的承载力明显提高,但其延性及耗能能力降低。  相似文献   

4.
为研究不同剪跨比、不同边缘构造形式对边缘配置高强纵筋的高强再生混凝土剪力墙抗震性能的影响规律,进行了3个C50再生混凝土剪力墙低周往复荷载试验,包括1个现浇高剪力墙、1个现浇中高剪力墙、1个装配式中高剪力墙。分析了各试件的破坏形态、滞回性能、承载力、延性、刚度退化、耗能能力。结果表明:边缘配置高强纵筋的高强再生混凝土剪力墙破坏形态均以弯曲破坏为主,各试件滞回曲线较饱满,耗能能力较好;中高剪力墙的承载力和刚度比高剪力墙明显提高,但延性系数降低;装配式再生混凝土中高剪力墙在达到峰值荷载之前整体性良好,但由于后浇结合面相对薄弱,试件破坏相对较早,承载力下降较快,延性稍差。基于试验结果,建立了边缘配置高强纵筋的高强再生混凝土中高及高剪力墙承载力计算公式,计算结果与试验结果吻合较好。  相似文献   

5.
为改善高强混凝土剪力墙的延性,设计了7个不同形式的高配筋率边缘约束构件高强混凝土剪力墙试件(边缘约束构件内的纵筋配筋率约为5%~8%)和1个普通配筋率的高强混凝土剪力墙试件,对其进行低周反复水平荷载作用下的拟静力试验,研究了剪力墙试件的破坏形态、滞回特性、变形能力、截面应变、刚度退化、耗能能力等。试验结果表明:对于剪跨比λ≥2的剪力墙,在高强混凝土剪力墙中设置高配筋率暗柱或端柱,并适当提高水平和竖向分布钢筋的配筋率,可以显著提高高强混凝土剪力墙的抗震性能。  相似文献   

6.
为研究型钢类型对型钢支撑混凝土剪力墙抗震性能的影响,进行了3个1/3缩尺的型钢支撑混凝土剪力墙和1个普通钢筋混凝土剪力墙对比试件低周反复荷载下的试验研究。得到了其破坏过程和破坏模式,并且分析了不同型钢类型对剪力墙承载能力、裂缝开展、刚度、延性及耗能的影响。试验结果表明:支撑对剪力墙的承载能力、刚度、延性及耗能性能均有较大提升作用。X形槽钢、X形角钢和X形工字钢支撑剪力墙的承载力分别比对比试件提高了71.8%、59.6%和49.4%,其延性系数分别提高了38.3%、5.3%和14.5%;型钢支撑混凝土剪力墙的刚度退化速率更加缓慢,而且中后期刚度明显优于对比试件;型钢支撑混凝土剪力墙的塑性区范围较对比试件大幅增加,试验得到的滞回环也更加饱满。  相似文献   

7.
为研究型钢类型对型钢支撑混凝土剪力墙抗震性能的影响,进行了3个1/3缩尺的型钢支撑混凝土剪力墙和1个普通钢筋混凝土剪力墙对比试件低周反复荷载下的试验研究。得到了其破坏过程和破坏模式,并且分析了不同型钢类型对剪力墙承载能力、裂缝开展、刚度、延性及耗能的影响。试验结果表明:支撑对剪力墙的承载能力、刚度、延性及耗能性能均有较大提升作用。X形槽钢、X形角钢和X形工字钢支撑剪力墙的承载力分别比对比试件提高了71.8%、59.6%和49.4%,其延性系数分别提高了38.3%、5.3%和14.5%;型钢支撑混凝土剪力墙的刚度退化速率更加缓慢,而且中后期刚度明显优于对比试件;型钢支撑混凝土剪力墙的塑性区范围较对比试件大幅增加,试验得到的滞回环也更加饱满。  相似文献   

8.
对3个单跨两层1∶3比例的方钢管混凝土框架-薄钢板剪力墙试件进行了低周反复荷载试验,研究了十字加劲薄钢板剪力墙的抗震性能,并与方钢管混凝土框架-非加劲薄钢板剪力墙比较。对比了框架梁柱内隔板式节点与穿芯高强螺栓-端板节点对结构性能的影响。得到了方钢管混凝土框架-薄钢板剪力墙的破坏形态、荷载-位移滞回曲线、骨架曲线、特征荷载和位移及抗震性能指标等,分析了结构的破坏特征、延性、耗能能力、承载能力及刚度退化等力学性能。结果表明,方钢管混凝土框架-薄钢板剪力墙具有良好的抗震性能;十字加劲肋限制了薄钢板剪力墙的面外变形,提高了其承载力与耗能能力,但对整体刚度影响较小;穿芯高强螺栓-端板节点提高了结构的承载力与刚度。  相似文献   

9.
通过一榀设置K型支撑的高强混凝土框架(UBCBF)和一榀不设支撑的高强混凝土框架(HSCMF)在低周反复荷载下的结构性能的对比试验,着重研究了高强混凝土支撑式框架的承载与变形能力、延性等抗震性能指标以及其变形刚度和破坏机制。试验结果表明,高强混凝土支撑式框架具有初始刚度大、极限承载力高,延性和耗能性能良好的特点。本文结合试验结果及其分析,给出了这种结构的抗侧力恢复力特性和抗震设计建议。  相似文献   

10.
进行4个足尺再生混凝土矮剪力墙试件的低周反复荷载试验,包括1个无EPS(模塑聚苯乙烯)保温模块剪力墙试件,3个带EPS保温模块剪力墙试件。对比分析各试件的承载力、延性、刚度、耗能和损伤演化规律|研究了保温模块及砂浆面层、再生混凝土强度、墙体分布钢筋配筋率对L形边框单排配筋矮剪力墙抗震性能的影响。研究表明:提高混凝土强度和分布钢筋配筋率可一定程度提高墙体的承载力和弹塑性变形能力|与无保温模块剪力墙试件相比,L形边框保温模块单排配筋矮剪力墙具有良好的抗震性能。  相似文献   

11.
提出了一种帽型冷弯薄壁型钢屈曲约束钢板剪力墙结构抗侧力体系。为了研究该帽型冷弯薄壁型钢屈曲约束钢板剪力墙结构的抗震性能,剥离了钢板剪力墙结构抗侧力体系中梁柱框架刚接对体系抗侧力的贡献,从钢板剪力墙中提取出“墙元”,并保证其为纯剪受力状态,设计了5个帽型冷弯薄壁型钢屈曲约束钢板剪力墙墙元试件,对其进行往复剪切荷载下的拟静力试验。结果表明:帽型冷弯薄壁型钢屈曲约束钢板剪力墙结构承载能力稳定,位移延性系数达到7以上,极限位移角达0.03rad,塑性变形能力较强;帽型冷弯薄壁型钢可以阻断内嵌钢板斜向通长拉力带,使钢板约束覆盖区域处于平面剪切受力变形状态,从而提升结构承载力、刚度和耗能能力,充分发挥钢板的材料性能;外贴OSB装饰板材可以满足建筑功能的适用性,同时强化了整体结构的抗震性能。  相似文献   

12.
在单排配筋混凝土低矮剪力墙的墙体或底部配置斜筋,可限制墙体斜裂缝开展,提高剪力墙的基底抗剪切滑移能力,改善其抗震性能。为了解不同斜筋布置形式对其动力性能与地震损伤破坏机理的影响,进行了3个不同配筋形式的混凝土低矮剪力墙模型振动台试验,包括1个普通单排配筋混凝土剪力墙,1个墙体内配置45°斜筋的单排配筋混凝土剪力墙,1个墙体底部配置45°斜筋的单排配筋混凝土剪力墙。在试验基础上,分析了3个剪力墙模型在弹性、开裂及弹塑性损伤破坏等不同受力阶段的自振特性与地震反应,比较了其破坏形态和加速度、位移时程反应。研究结果表明,配置斜筋能有效地提高单排配筋混凝土低矮剪力墙的抗震能力。  相似文献   

13.
In this paper, mid-rise shear wall with concealed truss was proposed. This new composite shear wall includes two kinds of composition: one is the composition of two bearing systems, including truss and shear wall, and the other is the composition of two materials, including steel and concrete. Therefore, it is a double composite shear wall. The experimental study on the seismic behavior of six 1/3 scale mid-rise shear walls, including an ordinary mid-rise shear wall, a mid-rise shear wall with steel frame, and four mid-rise shear wall with concealed truss made of different materials, was studied. Based on the experimental study, the stiffness and its attenuation, bearing capacity, ductility, hysteretic property, energy dissipation, and failure phenomena of each shear wall were contrastively analyzed. The formulas of bearing capacity and stiffness were established. The results obtained from the formulas and those from experiment are in good agreement. Some suggestions for seismic design of shear wall are given in this paper. The experimental results show that the seismic behavior of the mid-rise shear wall with steel frame and that of every truss with different materials is obviously improved.  相似文献   

14.
In this paper, mid-rise shear wall with concealed truss was proposed. This new composite shear wall includes two kinds of composition: one is the composition of two bearing systems, including truss and shear wall, and the other is the composition of two materials, including steel and concrete. Therefore, it is a double composite shear wall. The experimental study on the seismic behavior of six 1/3 scale mid-rise shear walls, including an ordinary mid-rise shear wall, a mid-rise shear wall with steel frame, and four mid-rise shear wall with concealed truss made of different materials, was studied. Based on the experimental study, the stiffness and its attenuation, bearing capacity, ductility, hysteretic property, energy dissipation, and failure phenomena of each shear wall were contrastively analyzed. The formulas of bearing capacity and stiffness were established. The results obtained from the formulas and those from experiment are in good agreement. Some suggestions for seismic design of shear wall are given in this paper. The experimental results show that the seismic behavior of the mid-rise shear wall with steel frame and that of every truss with different materials is obviously improved.  相似文献   

15.
带不同类型组合暗支撑剪力墙抗震性能试验研究   总被引:2,自引:0,他引:2       下载免费PDF全文
本文选取剪力墙结构体系中较为薄弱的抗震构件一字形截面剪力墙,采用不同类型的暗支撑进行了4个1/3缩尺的带暗支撑剪力墙构件的低周反复荷载试验,4个模型分别为普通剪力墙、带钢筋暗支撑剪力墙、带型钢暗支撑剪力墙、带钢筋-型钢暗支撑剪力墙。试验表明,带暗支撑剪力墙的主斜裂缝角度有明显向暗支撑的角度逼近的趋势,其裂缝细密且分布区域较大,墙体耗能能力较强。带暗支撑剪力墙比普通剪力墙底部塑性耗能区的高度显著增大。与普通剪力墙相比,带暗支撑剪力墙的屈服荷载、极限荷载明显提高,后期刚度稳定性较好,延性系数及耗能能力显著提高,滞回环饱满,抗震性能比普通剪力墙显著改善,特别是带钢筋-型钢组合暗支撑剪力墙的抗震性能提高最为显著。  相似文献   

16.
为寻求适用于自复位结构且具有显著捏缩滞回特征抗侧力部件,对单向斜槽钢板剪力墙(steel plate shear wall with inclined slots,IS-SPSW)、双向IS-SPSW及传统薄钢板剪力墙(traditional thin steel plate shear wall,TT-SPSW)的滞回性能进行了研究。分析了剪力墙板高厚比、跨高比参数对IS-SPSW滞回性能、水平承载力、抗侧刚度、耗能能力的影响,对比了双向IS-SPSW与TT-SPSW滞回性能的差异。分析结果表明,随剪力墙板高厚比的增加,单向IS-SPSW的水平承载力、抗侧刚度、耗能能力呈降低趋势。剪力墙板跨高比对单向IS-SPSW的水平承载力影响较大,对其滞回曲线、抗侧刚度及耗能能力几乎无影响。与TT-SPSW相比,对称布置的双向IS-SPSW具有显著捏缩的滞回特征和较高的水平承载力,非常适合作为自复位结构的主要抗侧力构件,可降低对复位部件用量的需求。  相似文献   

17.
为促进高性能绿色建筑结构发展,推动高强钢筋和中高强再生混凝土的工程应用,研发了边缘构件采用环筋扣合连接方式且配置高强纵筋的装配式中高强再生混凝土剪力墙,对6个剪跨比为2.2的装配式混凝土剪力墙进行了低周反复荷载试验。分析了不同再生粗骨料取代率、混凝土强度、边缘暗柱纵筋强度及搭接位置对装配式再生混凝土剪力墙的破坏形态、滞回性能、承载力、延性、刚度退化规律、耗能能力等抗震性能指标以及可恢复性能的影响。试验结果表明:边缘构件配置高强钢筋的装配式中高强再生混凝土剪力墙的破坏形态以弯曲破坏为主;再生粗骨料取代率对装配式中高强再生混凝土剪力墙的承载力、延性和耗能能力影响不大,各剪力墙均具有较好的抗震性能;边缘暗柱采用HRB600纵筋可有效提高装配式中高强再生混凝土剪力墙的承载力、耗能能力和可恢复性能;边缘暗柱纵筋在剪力墙底部塑性铰区搭接,会导致装配式中高强再生混凝土剪力墙的延性明显下降。给出了边缘配置HRB600纵筋的装配式中高强再生混凝土剪力墙水平承载力计算式,计算结果表明普通混凝土剪力墙的水平承载力计算模型同样适用于该装配式剪力墙结构。  相似文献   

18.
在水平地震作用下,低轴压比的单排配筋混凝土剪力墙易在底部施工缝处产生剪切滑移现象,影响其耗能能力,在剪力墙底部配置斜向钢筋可以较好地避免此现象发生。为研究配置斜筋单排配筋混凝土双肢剪力墙的抗震性能,对3个1/2缩尺的单排配筋混凝土双肢剪力墙进行了拟静力试验,研究了在墙肢及连梁中配置斜筋对混凝土双肢剪力墙破坏机制与抗震性能的影响。对比分析了配置斜筋双肢墙与未配置斜筋双肢墙的破坏形态、滞回特性、承载力、延性、刚度和耗能能力。试验结果表明:在墙肢配筋量相同的条件下,在墙肢底部设置适量的斜筋,可提高双肢墙的延性和耗能能力,并对其破坏机制产生影响;在墙肢分布钢筋量不变条件下,在墙肢底部和连梁中增设斜筋,可明显提高双肢墙的延性和耗能能力。  相似文献   

19.
为研究冷弯薄壁型钢-钢板剪力墙结构的抗震性能,对冷弯薄壁型钢边柱内置薄钢板剪力墙进行低周往复加载试验,对比不同边柱截面厚度及截面形式对其抗震性能的影响。试验中得到了冷弯薄壁型钢-钢板剪力墙的破坏形态、荷载-位移滞回曲线、骨架曲线、荷载及位移特征值,并对结构的破坏特征、延性、耗能能力、承载力及刚度退化进行分析。结果表明:冷弯薄壁型钢-钢板剪力墙具有良好的抗震性能;增加边柱截面厚度及选用帽形边柱均可提高剪力墙的承载力、刚度及耗能性能。计算3个试件受剪承载力设计值和弹性抗侧刚度,其值均高于常用冷弯薄壁组合墙体的;结合破坏特征提出冷弯薄壁型钢-钢板剪力墙3个受力阶段;边柱对剪力墙破坏起控制因素,工程设计中应保证边柱承载能力,宜采用"强边柱、弱钢板"的设计理念。  相似文献   

20.
为研究波形钢板-混凝土组合剪力墙的抗震性能,完成了竖向波形钢板-混凝土组合剪力墙、水平波形钢板-混凝土组合剪力墙以及平钢板-混凝土组合剪力墙拟静力试验,研究了波形钢板-混凝土组合剪力墙在低周往复荷载作用下的变形能力和破坏模式,分析了荷载-位移滞回曲线、骨架曲线、各阶段特征荷载和位移值等,以及结构的破坏特征、变形和耗能能力、刚度和承载力退化。试验结果表明:波形钢板-混凝土组合剪力墙具有较大的抗侧刚度、较好的延性和耗能能力;与平钢板-混凝土组合剪力墙相比,波形钢板-混凝土组合剪力墙有较好的界面黏结性能,而平钢板-混凝土剪力墙由钢板变形引起的混凝土剥落严重;波形钢板-混凝土组合剪力墙的初始刚度较平钢板-混凝土组合剪力墙的高,竖向波形钢板-混凝土组合剪力墙的承载力和极限位移较水平波形钢板-混凝土组合剪力墙的高,波形钢板-混凝土组合剪力墙的承载力退化和刚度退化比平钢板-混凝土组合剪力墙的慢,表现出较好的受力性能。采用ABAQUS有限元软件可以较好地模拟试验,有限元分析结果表明,波形钢板的应力分布比较均匀,组合作用效应明显,适合在抗震结构中采用。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏