首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This study was conducted to examine the impact of building characteristics and indoor air quality on recurrent wheezing in infants. We followed a birth cohort (BAMSE) comprising 4089 children, born in predefined areas of Stockholm, during their first 2 years of life. Information on exposures was obtained from parental questionnaires when the children were 2 months and on symptoms and diseases when the children were 1 and 2 years old. Children with recurrent wheezing, and two age-matched controls per case, were identified and enrolled in a nested case-control study. The homes were investigated and ventilation rate, humidity, temperature and NO2 measured. We found that living in an apartment erected after 1939, or in a private home with crawl space/concrete slab foundation were associated with an increased risk of recurrent wheezing, odds ratio (OR) 2.5 (1.3-4.8) and 2.5 (1.1-5.4), respectively. The same was true for living in homes with absolute indoor humidity >5.8 g/kg, OR 1.7 (1.0-2.9) and in homes where windowpane condensation was consistently reported over several years, OR 2.2 (1.1-4.5). However, air change rate and type of ventilation system did not seem to affect the risk. In conclusion, relatively new apartment buildings, single-family homes with crawl space/concrete slab foundation, elevated indoor humidity, and reported wintertime windowpane condensation were associated with recurrent wheezing in infants. Thus, improvements of the building quality may have potential to prevent infant wheezing.  相似文献   

2.
The effects of faults on an air handling unit (AHU) are often poorly evaluated (assuming indoor air quality (IAQ) problems), and under-estimated in consumption balances. Based on an experimental site, this paper presents a quantitative study of some different faults that can appear on AHUs.  相似文献   

3.
There seems to be a discrepancy between current Indoor Air Quality standards and end-users wishes and demands. Indoor air quality can be approached from three points of view: the human, the indoor air of the space and the sources contributing to indoor air pollution. Standards currently in use mainly address the indoor air of the space. “Other or additional” recommendations and guidelines are required to improve indoor air quality. Even though we do not fully understand the mechanisms behind the physical, chemical, physiological and psychological processes, it is still possible to identify the different ways to be taken regulatory, politically–socially (awareness), technically (process and product) and scientifically. Besides the fact that there is an urgent need to involve medicine and neuro-psychology in research to investigate the mechanisms behind dose-response, health effects and interactions between and with the other factors and parameters of the indoor environment and the human body and mind, a holistic approach is required including the sources, the air and last but not least the human beings (occupants) themselves. This paper mainly focuses on the European situation.  相似文献   

4.
Based on analysis of uncertainty, this paper presents grey system theory to handle the “grey” characteristic of IAQ. Grey comprehensive analysis of indoor air quality reveals that we should pay more attention to the air purification and humidity control in the design and maintenance of HVAC. In order to represent grey characteristic of IAQ system, the educed grey IAQ models can identify the variation intervals of key IAQ model parameters that are lack of directly measurable messages in practical situations. Furthermore, grey assessment is an effective multifactor comprehensive assessment method that can express the integrative influence of contamination indexes on indoor air quality. We can determine the IAQ grade and make comparison according to the grey incidence matrix R.  相似文献   

5.
我国目前室内空气品质改善的对策与措施   总被引:46,自引:3,他引:46  
沈晋明 《暖通空调》2002,32(2):34-37,48
强调改善室内空气品质应该有一种紧迫感,不应纠缠一些复杂的理论问题;当务之急是尽快建立起我国的室内空气品质标准和评价方法;尽管将成熟有效的措施和方法应用于实际。从这三方面介绍了应采取的对策和措施。  相似文献   

6.
Lam KS  Chan FS  Fung WY  Lui BS  Lau LW 《Indoor air》2006,16(2):86-97
A study was carried out to investigate the feasibility of achieving ultra low respirable suspended particulates (RSP) in commercial offices without major modification of existing ventilation systems by enhancing the particulates removal efficiency of existing central ventilation systems. Four types of filters which include pre-filters, cartridge filters, bag filters and high efficiency particulates air (HEPA) filters were tested in a commercial building in Causeway Bay. The results show that an RSP objective of <20 microg/m3 could be met by removing RSP from both the return air and outdoor air supply simultaneously. This level of performance is classed as 'excellent' by the Hong Kong Government, Environmental Protection Department. Filters with efficiency that exceed 80% placed both in the return air and outdoor air were sufficient to meet the objective. It is not necessary to install HEPA filters to achieve the 'excellent' class. The outdoor air filter has great influence on the steady state indoor RSP concentration while the effective cleaning rate is governed by the return air filter. Higher efficiency filters increased the static drop but the volume flow of the air fan was not affected significantly. The additional cost incurred was <5% of the existing operation cost. PRACTICAL IMPLICATIONS: This paper reports a field study of RSP control for an indoor office environment. The results are directly applicable to building service engineering in the design of ventilation systems using air-handling units. Field observations indicated that indoor RSP in an office environment could be suppressed below 20 microg/m3 within 1 h by the simultaneous filtration of outdoor air and return air. Outdoor air filtration has a great influence on the steady state indoor concentration and return air filtration governs the cleaning rate. It is believed that the results of this study could be extended to the cleaning of other indoor pollutants such as volatile organic compounds.  相似文献   

7.
室内空气品质若干误区辨析   总被引:6,自引:3,他引:6  
沈晋明 《暖通空调》2002,32(5):37-39,63
阐述了目前对室内空气品质问题一些认识上的误区。不解决这些误区就难以对室内环境实施更有效的控制,也难以将我国室内空气品质的研究提高到一个新水平。  相似文献   

8.
Air quality in two large athletic halls with different ventilation (natural and mechanical) was investigated in relation to outdoor pollution and meteorological conditions. Simultaneous measurements of O3, NO, NO2 and SO2 were performed in the halls at two heights (at the arena and spectators’ seats) and outdoors. BTX concentrations at the spectators’ seats and outdoor NMHCs, CH4, PM10 and CO concentrations were also measured. Analysis of diurnal variations of the pollutants’ concentrations, cross correlation analysis of the concentration time-series and principal component analysis were applied to the collected data. Results revealed that outdoor pollution significantly affected indoor air quality of both halls. However, this effect was different for the two buildings, depending on the ventilation types, the wind direction prevailing at the areas and the kind of indoor activity recorded. It was found that the latter parameters controlled the pollutants concentration levels in the halls and their response to the changes of the outdoor pollution levels. Temperature and pollution stratification enhancing during athletic events were also evident in both halls but with different characteristics observed, such as the spatial distribution of the indoor pollutants. The airflow patterns prevailing in each hall, imposed by the ventilation operation schemes were important factors.  相似文献   

9.
风管清洗:改善室内空气品质的有效方法   总被引:7,自引:1,他引:6  
刘东  陈沛霖  季雷  荣丽庄 《暖通空调》2003,33(4):139-140,77
介绍了几种适用于不同空调系统的风管清洗设备以及风管清洗的工艺流程。提出了风管清洗面临的问题。分析了几个实际工程风管清洗后的测试结果。  相似文献   

10.
An alternative method of maintaining indoor air quality may be through the biofiltration of air recirculating within the structure rather than the traditional approach of ventilation. This approach is currently being investigated. Prior to its acceptance for dealing with volatile organic compounds (VOCs) and CO2, efforts were made to determine whether the incorporation of this amount of biomass into the indoor space can have an (negative) impact on indoor air quality. A relatively large ecologically complex biofilter composed of a ca. 10 m2 bioscrubber, 30 m2 of plantings and a 3,500 litre aquarium were established in a 160 m2 'airtight' room in a recently constructed office building in downtown Toronto. This space maintained ca. 0.2 air changes per hour (ACH) compared to the 15 to 20 ACH (with a 30% refresh rate) of other spaces in the same building. Air quality parameters of concern were total VOCs (TVOCs), formaldehyde and aerial spore counts. TVOC and formaldehyde levels in the biofilter room were the same or significantly less than other spaces in the building despite a much slower refresh rate. Aerial spore levels were slightly higher than other indoor spaces but were well within reported values for 'healthy' indoor spaces. Levels appeared to be dependent on horticultural management practices within the space. Most genera of fungal spores present were common indoors and the other genera were associated with living or dead plant material or soil. From these results, the incorporation of a large amount of biomass associated with indoor biofilters does not in itself lower indoor air quality.  相似文献   

11.
Poor indoor air quality (IAQ) in schools is related to increased symptom reporting in students. We investigated whether parental worry about school IAQ influences this association. Data came from survey collected from five Finnish primary schools with observed IAQ problems and five control schools. Parents (n = 1868) of primary school students reported worry about IAQ in schools and symptoms of their children. Associations between observed IAQ problems, worry, and five symptom scores (ie, respiratory, lower respiratory, eye, skin, and general symptoms) were analyzed using multivariate logistic regression and mediation analysis. Parents were on average more worried in schools with observed IAQ problems. Observed IAQ problems were strongly associated with increased worry and all symptoms under study (unadjusted ORs ranged between 1.48 [95% CI 1.48‐2.16] and 2.70 [95% CI 1.52‐5.17]). Parental worry was associated with all symptoms (unadjusted ORs ranged between 2.49 [95% CI 1.75‐3.60] and 4.92 [95% CI 2.77‐9.40]). Mediation analyses suggested that parental worry might partially explain the association between observed IAQ problems and symptom reporting (proportion mediated ranged between 67% and 84% for the different symptoms). However, prospective studies are needed to assess causal relationships between observed IAQ problems, worry, and symptom reporting in schools.  相似文献   

12.
改善室内空气质量的下一个目标   总被引:1,自引:1,他引:0  
沈晋明  聂一新 《暖通空调》2007,37(7):34-39,60
根据国外发展的趋势,预测改善室内空气质量的下一个目标应是治理生物性污染,生物性污染将会取代目前建筑装饰材料污染成为我国主要室内微污染源。生物性污染主要是由空调系统污染和不合适的空调环境引起的,提出了余湿污染概念,并介绍了相关的研究工作以及应采取的控制措施。  相似文献   

13.
Sekhar SC  Tham KW  Cheong KW 《Indoor air》2003,13(4):315-331
An integrated indoor air quality (IAQ)-energy audit methodology has been developed in this study in Singapore, which provides a rigorous and systematic method of obtaining the status-quo assessment of an 'IAQ signature' in a building. The methodology entails a multi-disciplinary model in obtaining measured data pertaining to different dimensions within the built environment such as the physical, chemical, biological, ventilation, and occupant response characteristics. This paper describes the audit methodology and presents the findings from five air-conditioned office buildings in Singapore. The research has also led to the development of an indoor pollutant standard index (IPSI), which is discussed in this paper. Other performance indicators such as, the ventilation index and the energy index as well as the building symptom index (BSI) are also presented and discussed in the context of an integrated approach to IAQ and energy. Several correlation attempts were made on the various symptoms, indoor air acceptability, thermal comfort, BSI and IPSI, and while BSI values are found to correlate among them as well as with IAQ and THERMAL COMFORT acceptability, no such correlation was observed between BSI and IPSI. This would suggest that the occupants' perception of symptoms experienced as well as environmental acceptability is quite distinct from IAQ acceptability determined from empirical measurements of indoor pollutants, which reinforces the complex nature of IAQ issues.  相似文献   

14.
The analyses performed in this paper reveal that a breathing thermal manikin with realistic simulation of respiration including breathing cycle, pulmonary ventilation rate, frequency and breathing mode, gas concentration, humidity and temperature of exhaled air and human body shape and surface temperature is sensitive enough to perform reliable measurement of characteristics of air as inhaled by occupants. The temperature, humidity, and pollution concentration in the inhaled air can be measured accurately with a thermal manikin without breathing simulation if they are measured at the upper lip at a distance of <0.01 m from the face. Body surface temperature, shape and posture as well as clothing insulation have impact on the measured inhaled air parameters. Proper simulation of breathing, especially of exhalation, is needed for studying the transport of exhaled air between occupants. A method for predicting air acceptability based on inhaled air parameters and known exposure-response relationships established in experiments with human subjects is suggested. PRACTICAL IMPLICATIONS: Recommendations for optimal simulation of human breathing by means of a breathing thermal manikin when studying pollution concentration, temperature and humidity of the inhaled air as well as the transport of exhaled air (which may carry infectious agents) between occupants are outlined. In order to compare results obtained with breathing thermal manikins, their nose and mouth geometry should be standardized.  相似文献   

15.
The effect on indoor air quality of an air purifier based on photocatalytic oxidation (PCO) was determined by different measuring techniques: sensory assessments of air quality made by human subjects, Proton-Transfer-Reaction Mass Spectrometry (PTR-MS) and chromatographic methods (Gas Chromatography/Mass Spectrometry and High-Pressure Liquid Chromatography with UV detection). The experiment was conducted in a simulated office, ventilated with 0.6 h−1, 2.5 h−1 and 6 h−1, in the presence of additional pollution sources (carpet, chipboard and linoleum). At the lowest air change rate, additional measurements were made with no pollution sources present in the office. All conditions were tested with the photocatalytic air purifier turned on and off. The results show that operation of the air purifier in the presence of pollutants emitted by building materials and furniture improves indoor air quality, as documented by sensory assessments made by human subjects. It also reduces concentrations of many chemical compounds present in the air as documented by the PTR-MS technique. For the lowest ventilation, results from measurements using the chromatographic methods have similar tendency, however many of the 50 compounds that were targeted for analysis were not detected at all, independent of whether the purifier was on or off. For the two conditions with higher ventilation the results were inconclusive.  相似文献   

16.
Unlike commercial premises, the indoor air quality of residences is more dynamic, uncontrolled, and prone to human behavioral changes. In consequence, measuring the health benefit gains derived from improving indoor air quality in residences is more complicated. To overcome this, a human thermal comfort model was first integrated with indoor microenvironment models, and subsequently linked with appropriate concentration-response and economic data for estimating the economic benefit gains derived from improving indoor air quality in residences for an adult and an elderly person. In this study, the development of the model is illustrated by using a typical residential apartment locating at the worst air quality neighborhood in Hong Kong and the daily weather profiles between 2002 and 2006. Three types of personal intervention measures were examined in the study: (i) using air cleaner in residence, (ii) changing time spent in residence, and (iii) relocating to a better air quality neighborhood. Our results revealed that employing air cleaners with windows closed in residence throughout the entire year was the most beneficial measure as it could provide the greatest annual health benefit gains. It would give a maximum of HK$2072 in 5-year cumulative benefit gain for an adult and HK$1700 for an elderly person. Employing air cleaners with windows closed in only cool season (October through March) could give the highest marginal return per dollar spent. The benefit gains would become smaller when windows were opened to a greater extent. By contrast, relocating to a better air quality neighborhood and changing the time spent in residence did not appeal to be beneficial intervention measures.  相似文献   

17.
Indoor air quality of new apartment buildings, which is known to cause Sick Housing Syndrome, has become a major concern among apartment residents as well as construction companies in Korea. Recently, the Indoor Air Quality Management Act, a regulation that limits concentration levels of formaldehyde and five volatile organic compounds in new apartment buildings, has been implemented. In this study, the effects of ventilation and decomposing agents were investigated and compared, which could be used at the pre-occupancy stage as solutions to high VOCs concentration levels in new apartment buildings. Six housing units were investigated under different conditions to assess the extent of the improvement in indoor air quality. The results demonstrate that ventilation is an effective way to control indoor air pollution caused by VOCs emissions, and the effect of decomposing agents on improving indoor air quality depends on the types of VOCs.  相似文献   

18.
The uncertainties of professional choice of ‘representative’ sampling locations for general indoor air quality (IAQ) assessment are reported from the perspective of probable errors deviated from the sample-spatial average pollutant concentration of an indoor environment. In this study, associations between the professional choices of the sampling locations and attributes of the assessors were examined to quantify the uncertainties of the IAQ assessment results for a typical air-conditioned office in Hong Kong. In particular, a long-term (one-year) measurement result of the spatial indoor carbon dioxide (CO2) concentrations in this office was used as a basis to investigate the probable errors due to the choices of sampling locations. Comparing with the random choices, the assessment accuracy with the expert choices would be significantly improved for coarse sampling point densities at certain engineering acceptable error limits. It was reported that the location choices and assessment accuracy would be significantly influenced by the academic background of the assessors. An assessor group with higher academic level would make a choice leaning towards more accurate assessment results. To avoid an inappropriate level of reliance on the assessment results, uncertainties must be quantified for IAQ assessment. This study provided a template for further investigations into the uncertainties of IAQ assessment results involving professional choice of ‘representative’ sampling locations and the results might be a useful reference for assessing indoor environment elsewhere.  相似文献   

19.
Modern, holistic indoor climate research started with the formation of an interdisciplinary 'Indoor Climate Research Group' in 1962 at the Institute of Hygiene, University of Aarhus, Denmark. After some years, other groups started similar research in Denmark and Sweden, and later - after the First International Indoor Air Symposium in Copenhagen 1978--this research spread to many countries and today it is carried out globally by probably 2000 scientists. This paper recounts the history of Danish indoor climate research, focusing on the three decades from the early 1960s to the founding of the Indoor Air journal in 1991. The aim of this paper is to summarize what was learned in those earlier years and to call to the attention of researchers in this area the need of multidisciplinary research, mingling epidemiological fact-finding field studies with climate chamber studies and laboratory investigations. PRACTICAL IMPLICATIONS: The review may be of interest to indoor climate researchers who want to know more about the early development of research on this multidisciplinary subject, as it emerged in a small country that undertook pioneering studies.  相似文献   

20.
The research presented in this paper shows that moisture transfer between indoor air and hygroscopic building structures can generally improve indoor humidity conditions. This is important because the literature shows that indoor humidity has a significant effect on occupant comfort, perceived air quality (PAQ), occupant health, building durability, material emissions, and energy consumption. Therefore, it appears possible to improve the quality of life of occupants when appropriately applying hygroscopic wood-based materials. The paper concentrates on the numerical investigation of a bedroom in a wooden building located in four European countries (Finland, Belgium, Germany, and Italy). The results show that moisture transfer between indoor air and the hygroscopic structure significantly reduces the peak indoor humidity. Based on correlations from the literature, which quantify the effect of temperature and humidity on comfort and PAQ for sedentary adults, hygroscopic structures can improve indoor comfort and air quality. In all the investigated climates, it is possible to improve the indoor conditions such that, as many as 10 more people of 100 are satisfied with the thermal comfort conditions (warm respiratory comfort) at the end of occupation. Similarly, the percent dissatisfied with PAQ can be 25% lower in the morning when permeable and hygroscopic structures are applied.  相似文献   