首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 11 毫秒
1.
2.
Observed peptide gas-phase fragmentation patterns are a complex function of many variables. To systematically probe this phenomenon, an array of 40 peptides was synthesized for study. The array of sequences was designed to hold certain variables (peptide length) constant and randomize or balance others (peptide amino acid distribution and position). A high-quality tandem mass spectrometry (MS/MS) data set was acquired for each peptide for all observed charge states on multiple MS instruments, quadrupole-time-of-flight and quadrupole ion trap. The data were analyzed as a function of total charge state and number of mobile protons. Previously known dissociation trends were observed, validating our approach. In addition, the general influence of basic amino acids on dissociation could be determined because, in contrast to the more widely studied tryptic peptides, the amino acids H, K, and R were positionally distributed. Interestingly, our results suggest that cleavage at all basic amino acids is suppressed when a mobile proton is available. Cleavage at H becomes favored only under conditions where a partially mobile proton is present, a caveat to the previously reported trend of enhanced cleavage at H. Finally, all acquired data were used as a benchmark to determine how well these sequences would have been identified in a database search using a common algorithm, Mascot.  相似文献   

3.
Liang Z  Duan J  Zhang L  Zhang W  Zhang Y  Yan C 《Analytical chemistry》2004,76(23):6935-6940
Pressurized capillary electrochromatography (pCEC) was coupled with electrospray ionization mass spectrometry (ESI-MS) using a coaxial sheath liquid interface. It was used for separation and analysis of peptides and proteins. The effects of organic modifier and applied voltage on separation were investigated, and the effects of pH value of the mobile phase and the concentration of the electrolyte on ESI-MS signal were investigated. The resolution and detection sensitivity with different separation methods (pCEC, capillary high-performance liquid chromatography) coupled on-line with mass spectrometry were compared for the separation of a peptide mixture. To evaluate the feasibility and reliability of the experimental setup of the system, tryptic digests of cytochrome c and modified protein as real samples were analyzed by using pCEC-ESI-MS.  相似文献   

4.
Shrivas K  Wu HF 《Analytical chemistry》2008,80(7):2583-2589
A new approach of using modified silver nanoparticles (AgNPs) in toluene as hydrophobic affinity probes for the separation and preconcentration of peptides and proteins in biological samples prior to atmospheric pressure-matrix assisted laser desorption/ionization (AP-MALDI) ion trap mass spectrometry and matrix assisted laser desorption/ionization-time-of-flight (MALDI-TOF) mass spectrometry has been successfully demonstrated. To our best knowledge, for the first time, the modified AgNPs with hydrophobic ligands, such as dodecanethiol (DT) and octadecanethiol (OT) in toluene, were used for the liquid-liquid microextraction (LLME) of peptides and proteins through the hydrophobic interactions. In the present investigation, gramicidin was chosen as a model compound to assess the hydrophobic extraction with the modified AgNPs. The optimum extraction efficiency of gramicidine was observed at pH 7.0 for 1.5 h of extraction time with 7% addition of salt. Compared to the conventional use of AP-MALDI-MS, a 266-388-fold improvement in the limit of detection (LOD) for gramicidin was obtained in urine and plasma samples. The lowest concentration of gramicidin that was detected by using modified AgNPs in urine and plasma samples was 0.13 and 0.16 microM, respectively. Furthermore, the proposed method was demonstrated for the extraction of other long chain proteins, like myoglobin, ubiquitin, and bovine serum albumin, in a sample solution by matrix assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). The major feature of the newly synthesized modified AgNPs was that the target species could be efficiently separated and preconcentrated without sample loss prior to MALDI-MS detection for the sensitive and effective analysis of peptides and proteins in biological samples.  相似文献   

5.
New phosphorylated microbial metabolites referred to as phosphoantigens activate immune responses in humans. Although these molecules have leading applications in medical research, no direct method allows their rapid and unambiguous structural identification. Here, we interfaced online HPAEC (high performance anion-exchange chromatography) with ESI-ITMS (electrospray ionization ion trap mass spectrometry) to identify such pyrophosphorylated molecules. A self-regenerating anion suppressor located upstream of electrospray ionization enabled the simultaneous detection of pyrophosphoester by conductimetry, UV and MS. By HPAEC-ITMS and HPAEC-ITMS2, a single run permitted characterization of reference phosphoantigens and of related structures. Although all compounds were resolved by HPAEC, MS enabled their detection and identification by [M-H]- and fragment ions. Isobaric phosphoantigen analogues were also separated by HPAEC and distinguished by MS2. The relevance of this device was demonstrated for phosphoantigens analysis in human urine and plasma. Furthermore, identification of natural phosphoantigens by automatically generated 2D mass spectra from nano-ESI-ITMS is presented. This last technique permits the simultaneous performance of molecular screening of natural phosphoantigen extracts and their identification.  相似文献   

6.
Nie Z  Cui F  Tzeng YK  Chang HC  Chu M  Lin HC  Chen CH  Lin HH  Yu AL 《Analytical chemistry》2007,79(19):7401-7407
Herein, we report an application of charge-detection quadrupole ion trap mass spectrometry to the measurement of total dry masses of mammalian and poultry erythrocytes evaporated/ionized by laser-induced acoustic desorption. The method is rapid and widely applicable. Eight different types of red blood cells (RBCs) have been successfully analyzed, including those of human, goat, cow, mouse, pig, and chicken. The measured mean masses (weights per corpuscle) range from 0.58 x 10(13) Da (9.6 pg) of goat RBCs to 2.80 x 10(13) Da (46.5 pg) of chicken RBCs. The total dry weights determined for human RBCs from a healthy male adult, a patient with iron-deficiency anemia, and a patient with thalassemia are 34.8, 28.8, and 20.6 pg, respectively. These weights, except that of thalassemia, are all approximately 10% higher than their corresponding mean corpuscular hemoglobin values determined by a commercial automated hematology analyzer. The mass distribution profiles of the cells are all near-Gaussian, with a standard deviation of 15% for the normal human RBCs. The deviation increases significantly to 20% for RBCs with thalassemia characteristics and 27% for RBCs with iron-deficiency anemia characteristics. All the observations are in accord with their corresponding mean corpuscular volume measurements, indicating an increase in anisocytosis (variation in RBC size) in the anemic samples. Our results suggest a broad and promising application of this new technology to high-speed mass analysis of RBCs and other biological whole cells as well.  相似文献   

7.
Li FA  Wu MC  Her GR 《Analytical chemistry》2006,78(15):5316-5321
A four-channel multiplexed electrospray capillary electrophoresis interface has been developed. This new interface permits up to four capillary electrophoresis columns to be sampled sequentially by means of a stepper motor and a notched rotating plate assembly, which at any instant occludes all but a single sprayer. In this design, four sheath liquid electrospray probes are oriented in a circular array situated 90 degrees relative to one another. The rotating metal disk, which contains a one-quarter notch, is mounted to the stepper motor assembly and is located between the sprayers and the entrance aperture of an ion trap mass spectrometer. By using the data acquisition signal from the ion trap mass spectrometer, the scan event is synchronized with the rotation of the metal disk. With this device, four discrete sample streams can be simultaneously analyzed, resulting in a 4-fold increase in analytical throughput.  相似文献   

8.
The induced image charge and image current acquired by a detector tube for mass analysis are simulated using a numerical electrostatic model in the context of the electrostatic ion beam trap (EIBT). With the simulation results, the principle of mass analysis using the induced signal is demonstrated and studied systematically. The results show that the intensity of the detected signal is significantly influenced by the size and configuration of the detector, and also impacted by ion velocity, the number of ions in the ion group, and the ion beam length. The simulation results could not only be used to optimize the size and configuration of the detector and thus to improve the detected signal, but also to support the signal analysis (such as FFT) at an EIBT for mass spectrometry.  相似文献   

9.
A preparative mass spectrometer for microarray fabrication is reported. The instrument includes an atmospheric pressure ionization source, a linear ion trap mass analyzer, an ion collection surface positioning system, and a surface loading chamber with independent vacuum pumping. It was designed for the production of protein arrays using the ion soft-landing technique to collect ions on a surface after separation by mass/charge ratio. Small microarrays have been prepared by isolating and soft landing individual protein or peptide ions after electrospray ionization of mixtures. The composition and purity of the separated materials has been confirmed using independent external mass spectrometric analysis of rinse solutions of the collected spots, either by the new method of electrosonic spray ionization MS or by nanospray ionization MS. The ability to retain bioactivity in the mass-selected and collected biomolecules has been demonstrated in particular cases. The reported instrument has also been characterized as an analytical mass spectrometer.  相似文献   

10.
Cui M  Ding L  Mester Z 《Analytical chemistry》2003,75(21):5847-5853
Cisplatin and its mono- and dihydrated complexes have been separated using a high-field asymmetric waveform ion mobility spectrometry (FAIMS) analyzer interfaced with electrospray ionization (ESI) and ion trap mass spectrometry (ITMS). The addition of helium to the nitrogen curtain/carrier gas in the FAIMS device improved both the sensitivity and selectivity of the electrospray analysis. Introduction of a three-component mixture as curtain/carrier gas, nitrogen, helium, and carbon dioxide, resulted in further improvements to sensitivity. Compared with conventional ESI-MS, the background chemical noise in the ESI-FAIMS-ITMS spectrum was dramatically reduced, resulting in over 30-fold improvement in the signal-to-noise ratio for cisplatin. Analytical results were linear over the concentration range 10-200 ng/mL for intact cisplatin with a corresponding detection limit determined of 0.7 ng/mL with no derivatization or chromatographic separation prior to analysis.  相似文献   

11.
The fragmentation of natural peptides using dynamic collision-induced dissociation (DCID), a novel fragmentation method for quadrupole ion traps, is demonstrated. Using leucine enkephalin as a diagnostic molecule, the fragmentation efficiencies and energetics of DCID are compared with other methods of collisional activation in ion traps such as conventional on-resonance excitation and high-amplitude short-time excitation (HASTE). A typical fragmentation efficiency of approximately 20% is achieved for DCID, which is significantly lower than conventional CID (maximum near 80%). Tandem mass spectra of two other peptides, substance P and oxidized insulin alpha-chain, demonstrate that product ion spectra for DCID are comparable to conventional or HASTE CID. Because DCID achieves fragmentation during the standard mass acquisition scan, no extra time is necessary for on-resonance excitation or product ion collection, so analysis times are reduced by a minimum of 10-15% depending on the scanning conditions. DCID therefore offers more tandem mass spectra per second than conventional methods of collisional activation, which could be highly advantageous for bottom-up proteomics separations.  相似文献   

12.
A method is presented to quantify intermediate-abundance proteins in human serum using a single-quadrupole linear ion trap mass spectrometer-in contrast, for example, to a triple-quadrupole mass spectrometer. Stable-isotope-labeled (tryptic) peptides are spiked into digested protein samples as internal standards, aligned with the traditional isotope dilution approach. As a proof-of-concept experiment, four proteins of intermediate abundance were selected, coagulation factor V, adiponectin, C-reactive protein (CRP), and thyroxine binding globulin. Stable-isotope-labeled peptides were synthesized with one tryptic sequence from each of these proteins. The normal human serum concentration ranges of these proteins are from 1 to 30 microg/mL (or 20 to 650 pmol/mL). These labeled peptides and their endogenous counterparts were analyzed by LC-MS/MS using multiple reaction monitoring, a multiplexed form of the selected reaction monitoring technique. For these experiments, only one chromatographic dimension (on-line reversed-phase capillary column) was used. Improved limits of detection will result with multidimensional chromatographic methods utilizing more material per sample. Standard curves of the spiked calibrants were generated with concentrations ranging from 3 to 700 pmol/mL using both neat solutions and peptides spiked into the complex matrix of digested serum protein solution where ion suppression effects and interferences are common. Endogenous protein concentrations were determined by comparing MS/MS peak areas of the endogenous peptides to the isotopically labeled internal calibrants. The derived concentrations from a normal human serum pool (neglecting loss of material during sample processing) were 9.2, 110, 120, and 246 pmol/mL for coagulation factor V, adiponectin, CRP, and thyroxine binding globulin, respectively. These concentrations generally agree with the reported normal ranges for these proteins. As a measure of analytical reproducibility of this single-quadrupole assay, the coefficients of variance based on 12 repeated measurements for each of the endogenous tryptic peptides were 17.0, 25.4, 24.2, and 14.0% for coagulation factor V, adiponectin, CRP, and thyroxine binding globulin, respectively.  相似文献   

13.
The analytical performance of an atmospheric pressure sampling, multiple-channel, high-throughput mass spectrometer was investigated using samples of a variety of types. The instrument, based on an array of cylindrical ion traps, was built with four independent channels and here is operated using two fully multiplexed channels (sources, ion optics, ion traps, detectors) capable of analyzing different samples simultaneously. Both channels of the instrument were incorporated within the same vacuum system and operated using a common set of control electronics. A multichannel electrospray ionization source was assembled and used to introduce samples including solutions of organic compounds, peptides, and proteins simultaneously into the instrument in a high-throughput fashion. Cross-talk between the channels of the instrument occurred in the detection system and could be minimized to 1-2% using shielding between detector channels. In this initial implementation of the instrumentation, an upper mass/charge limit of approximately 1300 Th was observed (+13 charge state of myoglobin) and unit mass/charge resolution was achieved to approximately 800 Th. The rather limited dynamic range (2-3 orders of magnitude for low-concentration analytes) is due to cross-talk contributions from more concentrated species introduced into a different channel. Analysis of mixtures of alkylamines and peptides is demonstrated, but analysis of mixtures with a wide spread in mass/charge ratios was not possible due to mass discrimination in the ion optics. Further refinement of the vacuum system and ion optics will allow the addition of more channels of parallel mass analysis and facilitate applications in fields such as proteomics and metabolomics.  相似文献   

14.
One of the major factors governing the "top-down" sequence analysis of intact multiply protonated proteins by tandem mass spectrometry is the effect of the precursor ion charge state on the formation of product ions. To more fully understand this effect, electrospray ionization coupled to a quadrupole ion trap mass spectrometer, collision-induced dissociation, and gas-phase ion/ion reactions have been employed to examine the fragmentation of the [M + 12H]12+ to [M + H]+ ions of bovine ubiquitin. At low charge states (+1 to +6), loss of NH3 or H2O from the protonated precursor and directed cleavage at aspartic acid residues was observed. At intermediate charge states, (+7, +8, and +9), extensive nonspecific fragmentation of the protein backbone was observed, with 50% sequence coverage obtained from the [M + 8H]8+ ion alone. At high charge states, (+10, +11, +12), the single dominant channel that was observed was the preferential fragmentation of a single proline residue. These data can be readily explained in terms of the current model for intramolecular proton mobilization, that is, the "mobile proton model", the mechanisms for amide bond dissociation developed for protonated peptides, as well as the structures of the multiply charged ions of ubiquitin in the gas phase, examined by ion mobility and hydrogen/deuterium exchange measurements.  相似文献   

15.
A selective, rapid, and sensitive 12.7-min ultra performance liquid chromatography-isotope dilution tandem mass spectrometry (UPLC-ID/MS/MS) method was developed and compared to conventional high-performance liquid chromatography-isotope dilution tandem mass spectrometry (HPLC-ID/MS/MS) for the absolute quantitative determination of multiple proteins from complex matrixes. The UPLC analysis was carried out on an Acquity UPLC ethylene-bridged hybrid (BEH) C18 reversed-phase column (50 x 2.1 mm i.d., 1.7-microm particle size) with gradient elution at a flow rate of 300 microL/min. For the HPLC separation, a similar gradient profile on a reversed-phase C18 column with dimensions of 150 x 1.0 mm at a flow rate of 30 microL/min was utilized. The aqueous and organic mobile phases were 0.1% formic acid in water and acetonitrile, respectively. Detection was performed on a triple-quadrupole mass spectrometer operated in the multiple reaction monitoring mode. Linear calibration curves were obtained in the concentration range of 10-90 fmol/microL. Relative standard deviation values equal to or less than 6.5% were obtained by the UPLC-ID/MS/MS method, thus demonstrating performance equivalent to conventional HPLC-ID/MS/MS for isotope dilution quantification of peptides and proteins. UPLC provides additional dimensions of rapid analysis time and high-sample throughput, which expands laboratory emergency response capabilities over conventional HPLC.  相似文献   

16.
Xiong W  Glick J  Lin Y  Vouros P 《Analytical chemistry》2007,79(14):5312-5321
An ion-pair reversed-phase nano-high-performance liquid chromatography (IP-RP-nano-HPLC) method using a monolithic poly(styrene-divinylbenzene) (PS-DVB) column coupled to nanoelectrospray ionization mass spectrometry (nano-ESI-MS) was evaluated to separate and identify isomeric oligonucleotide adducts derived from the covalent binding of (+/-)-anti-7r,8t-dihydroxy-9t,10-epoxy-7,8,9,10-tetrahydrobenzo[a]pyrene [(+/-)-anti-BPDE] to double-stranded (ds) 5'-PO4--ACCCGCGTCCGCGC-3'/5'-GCGCGGGCGCGGGT-3' oligonucleotide. The influence of three different nanospray emitters on electrospray signal was evaluated in terms of analyte ion sensitivity. The best nanoelectrospray performance for the oligonucleotides was observed with the distal metal-coated emitter. The performance of three different stationary phases was also investigated. The chromatographic separation performance of the polymeric monolithic PS-DVB stationary phase significantly surpassed that of columns packed with the microparticulate sorbents C18 or PS-DVB. Different mobile phase organic solvents and ion-pairing reagents were also evaluated. An optimized mobile phase consisting of methanol and 25 mM triethylammonium bicarbonate resulted in the best chromatographic resolution and increased MS sensitivity of the oligonucleotides. By using a monolithic PS-DVB stationary phase fabricated in a nanocolumn, four positional isomeric (+/-)-BPDE-oligonucleotide adducts were separated and identified. In addition to four of the possible five positional isomers, three positional isomers were also resolved to several diastereoisomers, although their stereostructures could not be identified in the absence of reference standards.  相似文献   

17.
An electrospray ionization, dual gate, ion mobility, quadrupole ion trap mass spectrometer (ESI-DG-IM-QIT-MS) was constructed and evaluated for its ability to select mobility-filtered ions prior to mass analysis. While modification of the common signal-averaged ion mobility experiment was required, no modifications to the QIT were necessary. The dual gate scanning mode of operation was used to acquire mobility spectra, whereas the single mobility monitoring experiment selectively filtered ions for concentration and subsequent fragmentation within the QIT. Ion mobility separation of positively charged peptides and negatively charged carbohydrates, followed by MS fragmentation, was demonstrated. For a 1-min acquisition time, it was possible to obtain complete de novo sequence information for the examined peptides. Fragmentation of the negative carbohydrate chlorine adducts yielded ions characteristic of cross-ring and glycosidic bond cleavage. Previous unions of atmospheric pressure ion mobility and mass spectrometry have been limited in their ability to reproducibly obtain MSn data for mobility separation ions. The union of high-pressure ion mobility with quadrupole ion trap mass spectrometry presents the unique opportunity to obtain more detailed information regarding the chemistries of gas-phase ions.  相似文献   

18.
An ion trap/ion mobility/quadrupole/time-of-flight mass spectrometer has been developed for the analysis of peptide mixtures. In this approach, a mixture of peptides is electrosprayed into the gas phase. The mixture of ions that is created is accumulated in an ion trap and periodically injected into a drift tube where ions separate according to differences in gas-phase ion mobilities. Upon exiting the drift tube, ions enter a quadrupole mass filter where a specific mass-to-charge (m/z) ratio can be selected prior to collisional activation in an octopole collision cell. Parent and fragment ions that exit the collision cell are analyzed using a reflectron geometry time-of-flight mass spectrometer. The overall configuration allows different species to be selected according to their mobilities and m/z ratios prior to collision-induced dissociation and final MS analysis. A key parameter in these studies is the pressure of the target gas in the collision cell. Above a critical pressure, the well-defined mobility separation degrades. The approach is demonstrated by examining a mixture of tryptic digest peptides of ubiquitin.  相似文献   

19.
Atmospheric pressure electron capture dissociation (AP-ECD) is an emerging technique with the potential to be a more accessible alternative to conventional ECD/electron transfer dissociation (ETD) methods because it can be implemented using a stand-alone ion source device suitable for use with any existing or future electrospray ionization mass spectrometer. With AP-ECD, no modification of the main instrument is required, so it may easily be retrofitted to instruments not originally equipped with ECD/ETD capabilities. Here, we present our first purpose-built AP-ECD source and demonstrate its use in conjunction with capillary LC for the analysis of substance P, a tryptic digest of bovine serum albumin, and a phosphopeptide mixture. Quality ECD spectra were obtained for all the samples at the low femtomole level, proving that LC-AP-ECD-MS is suitable for the structural analysis of peptides and protein digests, in this case using an unmodified quadrupole time-of-flight mass spectrometer built ca. 2002.  相似文献   

20.
A matrix-assisted laser desorption/ionization (MALDI) ion trap mass spectrometer of new design is described. The instrument is based on a commercial Finnegan LCQ ion trap mass spectrometer to which we have added a MALDI ion source that incorporates a sample stage constructed from a compact disk and a new ion transmission interface. The ion interface contains a quadrupole ion guide installed between the skimmer and the octapoles of the original instrument configuration, allowing for operation in both MALDI and electrospray ionization modes. The instrument has femtomole sensitivity for peptides and is capable of collecting a large number of MALDI MS and MALDI MS/MS spectra within a short period of time. The MALDI source produces reproducible signals for 10(4)-10(5) laser pulses, enabling us to collect MS/MS spectra from all the discernible singly charged ions detected in a MS peptide map. We describe the different modes of the instrument operation and algorithms for data processing as applied to challenging protein identification problems.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号