首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
OBJECTIVE: The purpose of this study was to show the usefulness of MR imaging with a transrectal coil (TRC) in the management of various urethral abnormalities. This report also reveals the appearance of various postsurgical changes relating to the therapy of urethral abnormality. CONCLUSION: The high-resolution images obtained with TRC MR imaging were useful in evaluating urethral abnormalities. The imaging guided therapy in most cases. In two patients, TRC MR imaging more accurately depicted abnormality than did voiding cystourethrography and transvaginal sonography. In one case, TRC MR imaging was the only imaging technique that revealed the abnormality of periurethral scarring.  相似文献   

2.
The patients with strabismus, including 8 with superior oblique paresis, 1 with inferior rectus paresis, and 1 with congenital constant exotropia, were examined with MR imaging at 1.5 tesla (T) or 0.5T with a surface coil. Abnormal findings of extraocular muscles were identified in 8 of the 10 patients and most of them were consistent with the clinical findings. Deviation of the optic nerves was noted in 5 patients. Coronal short repetition time (RT) and echo time (ET) images were used to measure the concerned extraocular muscles and the optic nerves. The differences in diameters between the concerned extraocular muscles of both the diseased and normal eyes were calculated. MR imaging is considered to be advantageous and can be favorably used to observe and measure the extraocular muscles and other intraorbital structures in patients with strabismus.  相似文献   

3.
OBJECTIVE: The aim of this study was to describe the MR appearance of acute appendicitis and to determine the value of MR imaging for diagnosis of acute appendicitis. SUBJECTS AND METHODS: Forty-five children (28 girls, 17 boys), 7-16 years old (mean age, 13 years old), with clinically diagnosed acute appendicitis underwent independently graded compression sonography by two radiologists. MR imaging was performed when sonography revealed acute appendicitis (observer 1, 16 [36%] patients; observer 2, 18 [40%] patients), was inconclusive (observer 1, two [4%] patients; observer 2, one [2%] patient), and was interpreted as normal (observer 1, two [4%] patients; observer 2, one [2%] patient) (n = 20). Axial T1-weighted turbo spin-echo sequences, T2-weighted turbo spin-echo sequences in the axial and coronal planes, and fat-suppressed short inversion time inversion recovery turbo spin-echo sequences in the axial plane (4-mm slice thickness) were obtained and evaluated independently by two radiologists. The ability to see acute appendicitis with MR imaging was evaluated, the appearance and morphologic changes were described, and the most accurate sequence was determined. All children in whom MR imaging was performed underwent surgery. RESULTS: MR imaging revealed acute appendicitis in all cases (100%) by both observers. On T2-weighted ultra turbo spin-echo images, acute appendicitis appeared with a markedly hyperintense center, a slightly hyperintense thickened wall, and markedly hyperintense periappendiceal tissue. Unenhanced axial T2-weighted spin-echo imaging was the most sensitive sequence. CONCLUSION: In this study group, MR imaging was a valuable technique for depiction of acute appendicitis.  相似文献   

4.
OBJECTIVE: Our objective was to evaluate the accuracy of MR imaging strategy that uses primarily fast spin-echo sequences for the diagnosis of anterior cruciate ligament tears. MATERIALS AND METHODS: The original clinical interpretations of MR images of 217 examinations of the knee joint were correlated with subsequent arthroscopic results. Each MR examination included a double-echo fast spin-echo sequence as the only imaging sequence in the sagittal plane. Subsequent discordant MR and arthroscopic examinations were then subjected to reanalysis by two observers who were unaware of arthroscopic results to determine if misinterpretations were observer or image dependent. Two hundred sixteen patients who underwent MR imaging for suspected internal derangement of the knee subsequently underwent arthroscopic surgery. Two patients had both knees evaluated. One patient was excluded because he was referred for evaluation for osteomyelitis, not internal derangement. This yielded a total number of 217 MR examinations for suspected internal derangement of the knee. RESULTS: For 56 arthroscopically proven tears, the sensitivity of MR imaging was 96%. The specificity was 98%, yielding an overall accuracy rate of 98%. The positive and negative predictive values were 95% and 99%, respectively. These values are within the ranges of previously reported MR imaging strategies using conventional spin-echo sequences. CONCLUSION: Fast spin-echo MR imaging of the knee can be an alternative to conventional spin-echo imaging for the detection of anterior cruciate ligament tears.  相似文献   

5.
Cnidarians (e.g., sea anemones and corals) are the lowest animal group having a nervous system. Previously, we cloned a receptor from sea anemones that showed a strong structural similarity to the glycoprotein hormone (TSH, FSH, LH/CG) receptors from mammals. Here, we determine the genomic organization of this sea anemone receptor. The receptor gene contains eight introns that are all localized within a region coding for the large extracellular N terminus. These introns occur at the same positions and have the same intron phasing as eight introns in the genes coding for the mammalian glycoprotein hormone receptors, indicating that the cnidarian and mammalian receptor genes are evolutionarily related. As with the mammalian receptor genes, the sea anemone receptor gene does not contain introns in the region coding for the transmembrane and intracellular domains. Southern blot analyses show that the cnidarian receptor is coded for by a single gene.  相似文献   

6.
In eight Japanese patients, three different laparoscopic procedures were used to excise an early gastric carcinoma; partial resection in four, intragastric resection of the gastric mucosa in two, and laparoscopic-assisted distal partial gastrectomy with the abdominal wall-elevating method in two patients. Histological examinations revealed that the lesions were completely resected, and there was no evidence of lymphatic metastasis. The operation time ranged from 2 to 4 h. These forms of laparoscopic gastric surgery for patients with early gastric carcinomas may be useful from the standpoint of minimal access, rapid recovery, less pain, and good cosmesis.  相似文献   

7.
PURPOSE: To study the magnetic resonance (MR) imaging appearance of the ulnar collateral ligament (UCL) and its insertion into the medial epicondyle. MATERIALS AND METHODS: Sixteen normal and 20 symptomatic elbows were examined with a 1.5-T unit. Normal elbows were imaged with axial T2*-weighted three-dimensional Fourier transform sequences. Symptomatic elbows were imaged with coronal T1-, T2-, and T2*-weighted and/or short-inversion-time inversion-recovery sequences. RESULTS: In normal immature elbows, the ulnar periosteum was seen as an extension of the UCL, and its enthesis had signal intensity characteristics that differed from those of the mature ligament. In symptomatic elbows imaged before epiphyseal fusion, segmentation and subchondral bone resorption of the ossification center were seen with or without a capsular tear. After epiphyseal fusion, a full-thickness or a partial UCL tear at the site of its insertion, with or without subcortical bone resorption, was seen. CONCLUSION: The MR imaging characteristics of the developing elbow differ from those of the mature elbow. MR imaging is useful in assessing UCL damage.  相似文献   

8.
9.
Diagnostics of epi- and subdural haematomas of the spinal cord is discussed on the basis of 1992 records of Konstancin Rehabilitation Center. Fifty-four patients with symptoms of partial or complete cord injury were submitted to MR imaging. In four cases (7.5 per cent) epi- or subdural haematoma was found to contribute to neurological condition of the patient. MRI determines indications for surgical intervention.  相似文献   

10.
PURPOSE: To investigate, by means of MR phase imaging, the effects of compression on the velocity of craniocaudal motion in the spinal cord. MATERIAL AND METHODS: Spin-echo pulse sequences with velocity encoding gradients were used to examine 12 patients with cervical spondylosis and 6 normal volunteers. Oblique-axial phase images at 3 levels (cranial, middle and caudal), were obtained with prospective electrocardiogram gating. The middle level was set at the site where the spinal cord was most severely compressed, and the cranial and caudal sections were set where it was not compressed. Time-velocity curves were generated at these 3 levels and focal velocity change was correlated with motor function in the lower extremities. RESULTS AND CONCLUSION: The cord showed a higher motion velocity at the compression level than at noncompression levels. This paradoxical increase in velocity was observed in 7 out of 8 patients whose lower extremity motor function was impaired. Four patients with normal lower extremity motor function did not demonstrate this increase in velocity. An increase in motion velocity was therefore found to correlate with impaired lower extremity motor function.  相似文献   

11.
OBJECTIVE: The purposes of this study were to determine the frequency of discordant MR findings of the anterior cruciate ligament (ACL) using sagittal-oblique images and the arthroscopic integrity of the ACL in knees with a discordant MR appearance. MATERIALS AND METHODS: The frequency of discordant MR features was determined by independently reviewing the sagittal-oblique images of 53 consecutive patients undergoing subsequent arthroscopic surgery. The first 25 consecutive knees were examined using a conventional, dual-echo, T2-weighted spin-echo (SE) sequence; the subsequent 28 consecutive knees were examined using both a T1-weighted SE(T1) and a fat-suppressed, fast spin-echo (FSE) T2-weighted sequence. Two examiners who were unaware of patient identification and arthroscopic results evaluated only the sagittal images that included the ACL. Each reviewer graded the ACL as torn or intact. The MR appearance was considered discordant when one MR sequence showed disrupted or poorly seen ACL fibers and the other sequence showed intact ACL fibers. The arthroscopic integrity of the ACL was determined for the 20 knees with a discordant MR appearance. RESULTS: A discordant MR appearance of the ACL was seen in 20 of the 53 knees (38%), including 10 knees evaluated using conventional T2-weighted sequences (40%) and 10 knees using T1/FSE T2 (36%) sequences. Arthroscopic examination of these knees showed intact ACL fibers in all 20 knees; the ACL was normal in 18 knees and a partial tear was questioned in two knees. CONCLUSION: A discordant appearance of the ACL was frequently encountered (38%) using either conventional T2-weighted sequences or T1 and FSE MR sequences in the sagittal-oblique plane. Intact ACL fibers were found during arthroscopy in all 20 knees with a discordant MR appearance.  相似文献   

12.
PURPOSE: Endothelin-1 (ET-1), a peptide produced by the vascular endothelium, causes profound renal vasoconstriction by binding to ET-A receptors. The present study examined the renal actions of ET-1 after ET-A receptors were blocked by BE-18257B to unmask the functions of ET-B receptors. MATERIALS AND METHODS: Renal hemodynamics and clearance measurements were obtained in anesthetized dogs after intrarenal infusion of BE-18257B at 100 ng./kg./min. (Group 1), after intrarenal infusion of ET-1 at 2 ng./kg./min. (Group 2), or after intrarenal infusion of ET-1 superimposed on BE-18257B (Group 3). RESULTS: In Group 1, BE-18257B infusion did not alter arterial pressure, renal blood flow (RBF), GFR or tubular function. In Group 2, ET-1 infusion led to a significant decrease in RBF and GFR (37 and 40%, respectively) without altering arterial pressure. Urinary volume and sodium excretion were not changed but osmolality decreased significantly. In Group 3, BE-18257B infusion significantly attenuated the decrease in RBF caused by ET-1 and increased GFR by 40% without altering arterial pressure, associated with significant diuresis and natriuresis. CONCLUSION: Renal vasoconstriction caused by ET-1 is attenuated by ET-A receptor blockade with BE-18257B, which unmasks the hemodynamic and tubular actions of ET-B receptors. As a result, it limits the ET-1 induced decrease in RBF and raises GFR, and leads to a diuresis and natriuresis.  相似文献   

13.
14.
15.
OBJECTIVE: The purpose of this study was to evaluate dynamic MR imaging in assessing the depth of stromal invasion by carcinoma of the cervix and to compare dynamic MR imaging with T2-weighted and contrast-enhanced T1-weighted MR imaging. SUBJECTS AND METHODS: Forty-one patients with carcinoma that was clinically considered to be confined to the cervix were examined with T2-weighted, dynamic, and contrast-enhanced T1-weighted MR imaging before surgery. We evaluated enhancement patterns of the cervix and tumor and assessed the degree of stromal invasion with MR imaging. The degree of stromal invasion was divided into two groups: superficial disease (no stromal invasion or invasion of < or = 3 mm) and deep invasion (> 3 mm of stromal invasion). Then we compared these MR findings with histologic results for the depth of stromal invasion. RESULTS: With dynamic MR imaging, cervical carcinoma with deep invasion was seen as a focal enhanced area in the early dynamic phase. The cervical epithelium and stroma enhanced less vividly. In distinguishing deep invasion from superficial disease, we found the accuracy of T2-weighted MR images, dynamic MR images, and contrast-enhanced T1-weighted MR images to be 76%, 98%, and 63%, respectively. In particular, the detectability of 3.1-5.0 mm of stromal invasion with dynamic MR images was significantly higher than that with the other techniques: with T2-weighted MR images, we saw 3.1-5.0 mm of stromal invasion in 23% of patients; with dynamic MR images, in 92%; and with contrast-enhanced T1-weighted MR images, in none. Superficial disease was not revealed with any of the three MR techniques. CONCLUSION: We believe that dynamic MR imaging is superior to T2-weighted MR imaging and contrast-enhanced T1-weighted MR imaging when assessing the depth of invasion of cervical carcinoma.  相似文献   

16.
PURPOSE: To characterize white matter changes in early-treated phenylketonuria (PKU) with magnetic resonance (MR) imaging and hydrogen-1 MR spectroscopy and to correlate these findings to biochemical control and brain function. MATERIALS AND METHODS: Fifty-one patients aged 12-33 years underwent T1-, T2-, and proton-density-weighted MR imaging and testing of intelligence, visual evoked potentials (VEPs), and neuropsychologic status (29 adult patients only). H-1 MR spectroscopy was performed in eight patients to determine brain metabolite concentrations, including phenylalanine (PHE) concentration, and brain compartmentation. RESULTS: MR imaging revealed a high frequency of supra- and infratentorial abnormalities. MR imaging grade, which was based on areas of high signal intensity on T2-weighted images, showed statistically significant correlation with long-term biochemical control and neuropsychologic test results but not with intelligence quotient or VEPs. H-1 MR spectroscopy revealed normal metabolite levels, except for increased PHE levels. It also showed enlarged cerebrospinal fluid-like compartments in affected white matter, related to plasma and brain concentrations of PHE and MR imaging grades. CONCLUSION: A synergistic use of MR imaging and MR spectroscopy may help elucidate both the pathogenesis of brain dysfunction and clinical treatment policies in PKU.  相似文献   

17.
18.
The National Cancer Data Base is a community-oriented cancer management and outcomes database that is the joint project of the Commission on Cancer of the American College of Surgeons and the American Cancer Society. This article provides a first look at highlights from the 1998 summary.  相似文献   

19.
In the first phase of this study, seven healthy subjects underwent examination with two-dimensional time-of-flight (TOF) magnetic resonance (MR) angiography to develop a protocol for evaluation of peripheral arterial vasculature from the infrarenal aorta to the foot. In the second phase, 73 patients with symptomatic peripheral vascular disease underwent examination with both conventional contrast material-enhanced arteriography and two-dimensional TOF MR angiography to evaluate the clinical usefulness of MR angiography. Postinterventional and intraoperative angiography or direct surgical exploration was the standard of reference. In 32 patients, discrepancies occurred between findings on arteriograms and those on MR angiograms; most of these discrepancies were caused by improved depiction of runoff vessels on MR angiograms. The demonstration with MR angiography of blood vessels not seen on conventional arteriograms, unidentified stenoses, or misidentified blood vessels altered surgical management in 12 patients (16%). Metal-clip artifacts obscured clinically important disease on MR angiograms in two patients. It is concluded that two-dimensional TOF MR angiography is very useful in preoperative assessment of patients with severe peripheral vascular disease.  相似文献   

20.
OBJECTIVE: The purpose of this study was to apply multishot echoplanar MR imaging (EPI) to the female pelvis and compare image quality with that of fast spin-echo MR imaging. SUBJECTS AND METHODS: Twenty-one patients with suspected pelvic disease and five healthy female volunteers were prospectively examined. MR imaging was obtained using an EPI-capable 1.0-T imager and a pelvic phased-array coil. Axial EPI and fast Spin-echo sequences were obtained at identical image locations in each patient and volunteer. Spin-echo EPI images were obtained using a multishot number of 16. Acquisition time for each EPI sequence was 2 min 10 sec. Fat-suppressed T2-weighted fast spin-echo images were obtained in 2 min 12 sec. Paired EPI and fast spin-echo MR images were independently evaluated by three reviewers. RESULTS: Delineation of the perivaginal and parametrial venous plexus on EPI was rated superior to the fast spin-echo images in 62 (77%) of 81 cases. On EPI, uterine zone anatomy and ovary visualization were judged to be inferior in 44 (56%) of 78 cases and in 18 (33%) of 54 cases, respectively. For delineation of uterine abnormalities, including leiomyoma and adenomyosis, both sequences performed almost equally well. However, ovarian cystic lesions were revealed more precisely by the fast spin-echo sequence. An overall fat-suppression effect was seen on EPI images in 62 (77%) of 81 cases. CONCLUSION: Multishot EPI cannot replace fast spin-echo sequences for imaging the female pelvis; however, because EPI has a potent fat-suppression effect and heavily T2-weighted contrast, EPI sequences can be a valuable adjunct to routine examination.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号