共查询到20条相似文献,搜索用时 609 毫秒
1.
通过对高效液相色谱法测定葡萄酒中合成色素苋菜红质量浓度的全过程分析,确定了测定结果不确定度的来源。采用计量学不确定度传递模型,对引入的不确定度分量进行评定,确定了葡萄酒中苋菜红质量浓度标准不确定度由标准物质、标准溶液配制、标准曲线拟合、样品制备、测量重复性和回收率等6部分不确定度合成得到。2个不同质量浓度样品测定结果不确定度被评定,其相对扩展不确定度分别为2.6%和2.2%(k=2),由不确定度评价结果分析得到,样品重复性测定和标准溶液配制是测定结果不确定度的主要来源。 相似文献
2.
3.
一、概述
1.测量依据:JJG464-1996<生化分析仪>检定规程.
2.环境条件:温度为(20±5)℃,相对湿度小于80%.
3.测量标准:生化分析仪检定用吸光度标准物质,吸光度值分别为0.5、1.0,不确定度为0.005. 相似文献
4.
本文根据半自动生化分析仪的检定规程,运用测量不确定度评定与表示方法,对其吸光度示值误差测量值的不确定度进行分析评定。 相似文献
5.
6.
7.
原子吸收光谱法测定奶粉中铁含量的不确定度评定 总被引:2,自引:0,他引:2
对原子吸收光谱法测定奶粉中铁含量的测量不确定度进行评定,分析了该测量过程的测量不确定度来源,建立数学模型,找出了主要影响因素。结果表明,回收率、拟和直线求样品溶液浓度及测量重复性是合成标准不确定度的主要来源。 相似文献
8.
9.
10.
11.
A method is proposed for estimating the parameters of a mixture of exponential and Weibull distributions for which the accuracy of preliminary estimates obtained by graphical analysis is refined in accordance with the criterion of maximum likelihood. The efficiency of the proposed method is supported by the results of statistical modeling. 相似文献
12.
An approximate analytical expression is derived for the velocity of the front of the wave of change of boiling modes on a
rod and on a plate. The impact of the Thomson effect and of the heater orientation in the gravity field is included. Adequate
agreement is demonstrated between the derived relations and experimental data. 相似文献
13.
14.
15.
水三相点是开尔文热力学温度的唯一基准点,也是ITS-90国际温标重要的定义固定点。因此,水三相点不确定度分析对整个温标的建立、温度量值传递起着至关重要的作用。近3年来,中国计量科学研究院研制出一系列高质量的水三相点容器,加强了水三相点的研究,为不确定度的分析提供了更为可靠的实验依据。同时,不确定度的分析也是客观评价新研制容器性能的一个重要指标。因此,根据实验结果对新研制容器所复现的水三相点进行了不确定度评定。评定结果表明,其扩展不确定度为0.16mK(k=2.69,P=0.99)。 相似文献
16.
17.
18.
19.
Liebert A Wabnitz H Grosenick D Möller M Macdonald R Rinneberg H 《Applied optics》2003,42(28):5785-5792
A novel method for the determination of the optical properties of tissue from time-domain measurements is presented. The data analysis is based on the evaluation of the first moment and the second centralized moment, i.e., the mean time of flight and the variance of the measured distribution of times of flight (DTOF) of photons injected by short (picosecond) laser pulses. Analytical expressions are derived for calculation of absorption and of reduced scattering coefficients from these moments by application of diffusion theory for infinite and semi-infinite homogeneous media. The proposed method was tested on experimental data obtained with phantoms, and results for absorption and reduced scattering coefficients obtained by the proposed method are compared with those obtained by fitting of the same data with analytical solutions of the diffusion equation. Furthermore, the accuracy of the moment analysis was investigated for a range of integration limits of the DTOF. The moment analysis may serve as a comparatively fast method for evaluating optical properties with sufficient accuracy and can be used, e.g., for on-line monitoring of optical properties of biological tissue. 相似文献
20.
本文根据多年的实践检定经验 ,参照JJF1 0 59- 1 999《测量不确定度评定与表示》以及《测量不确定度表达 1 0讲》 ,对卧式金属罐容量的测量结果不确定度进行了评定。 相似文献