首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 287 毫秒
1.
The objective is to evaluate bacteremia outcomes and survival rates when using guidewire exchange to place tunnelled hemodialysis catheter (THDC) compared with a new-site replacement. Retrospectively, all patients were identified who received a THDC between January 1, 2000 and January 1, 2007. Any THDC having received antibiotic line locks or tunnel-to-tunnel exchange were excluded. This left 408 THDC placed in 329 patients: 46 guidewire exchange, 362 new-site replacement. Bacteremia rate from the new-site insertion group was 3.0 per 1000 catheter days, the guidewire exchange group demonstrated a rate of 2.8 per 1000 catheter days. Local infection rates did not differ between the groups at 1.2 per 1000 catheters days. The actuarial catheter survival rates using Kaplan-Meier survival analysis demonstrated no difference between the 2 groups. The placing of tunnelled cuffed hemodialysis catheters to replace temporary catheters using a guidewire exchange did not contribute to further episodes of sepsis and has the advantage of preserving venous access and minimizing invasive procedures for the patient.  相似文献   

2.
Introduction: Ethanol lock solution has been mainly administered in paediatric and home parenteral nutrition patients in order to prevent catheter related blood stream infections (CRBSI). Its utility in hemodialysis (HD) patients with non‐tunneled‐uncuffed catheter (NTC) has been poorly explored. Methods: We conducted a prospective randomized study in chronic HD patients requiring a newly inserted NTC‐while awaiting for the maturation of an already established arteriovenous fistula (AVF) or arteriovenous graft (AVG) or tunneled‐cuffed catheter insertion. Patients were randomized in two groups: Group A, where the lock solution was ethanol 70% + unfractionated heparin 2000 U/mL and group B, that received only unfractionated heparin 2000 U/mL. Primary end point was CRBSIs whereas exit site infections, thrombotic and bleeding episodes were the secondary end points. Findings: One hundred three HD patients were enrolled in the study (group A, n = 52; group B, n = 51). The median number of catheter days was 32 for group A (range: 23–39) and 34 (range: 27–40) for group B with no statistically significant difference between the two groups. Group A (ethanol + heparin) demonstrated 4/52 episodes (7.69%) of CRBSI whereas Group B (heparin) 11/51 episodes (21.57%) (P = 0.04). CRBSI rates per 1000 catheter days were 2.53/1000 catheter days for group A and 6.7/1000 catheter days for group B (P = 0.04). Mean cumulative infection‐free catheter survival in the ethanol group did not differ significantly compared to the heparin group (log‐rank test = 2.99, P = 0.08). Thrombotic episodes did not differ between the two groups. Discussion: Locking of NTCs in HD patients with ethanol 70% + unfractionated heparin reduces CRBSI rates without increasing the thrombotic episodes.  相似文献   

3.
The percutaneous catheterization of central veins is increasingly used in nephrological practice as a temporary or permanent vascular access. The aim of our study was to present and to analyze episodes of catheter tip malposition during percutaneous tunneled hemodialysis catheter insertion in the large, unselected group of patients. All patients who underwent the procedure of catheter insertion in our department during year 2012 were analyzed retrospectively. One hundred four tunneled hemodialysis catheters were inserted in 101 patients. In 58 patients, the catheter was inserted at the initiation of hemodialysis therapy as the first access and in 46 the catheter was placed because of the failure of the existing one. In 68 patients, the catheter was inserted into the right internal jugular vein and in 20 patients into the left internal jugular vein (LIJV). Subclavian veins were used in five cases and femoral veins in 11 cases. Malposition of the catheter tips occurred in six patients. In all cases, the LIJV was cannulated. In two cases, the catheter tip malposition was in the right innominate vein and in four cases in the azygos vein. Our data demonstrate that with the blind insertion of tunneled hemodialysis catheters, the risk of catheter tip malposition is significantly higher with the left side insertion. As catheter insertion through the LIJV holds very high (30%) risk of the tip malposition, it should always be performed under the fluoroscopic control.  相似文献   

4.
We report a case of long‐term uneventful catheter use in a patient with previous recurrent vascular access dysfunction and infection. A single‐lumen tunneled catheter was inserted into the left internal jugular vein after a failed attempt of dual‐lumen permanent catheter placement. The follow‐up since device implantation has exceeded 5 years without any complications related to vascular access.  相似文献   

5.
Lynchburg Nephrology Dialysis Inc. started its nightly home hemodialysis (NHHD) program in September 1997.
Purpose of study:  To evaluate episodes of exit site infections, catheter sepsis, safety, and longevity of accesses for patients doing NHHD.
Methods:  If IJ catheter was chosen, patient was started on Coumadin 2 mg/day when catheter was placed. If catheter malfunctioned, it was locked with a thrombolytic agent and Coumadin was adjusted to meet a goal INR of 1.5–2.25. If the problem persisted, the catheter was exchanged. For catheters, the B-D InterLink device was used to prevent air emboli and infection, and a locking device was used to prevent disconnects. If AV fistula was used, 4 buttonholes were established using 16 gauge needles. If AV graft was used, patients were taught the ladder cannulation technique using 16 gauge needles.
Results:  As of September 1, 2003, 45 patients have completed training and have performed 27,063 treatments at home. Total catheter time at home was 930 months. Total AV fistula and AV graft time at home was 190 and 20 months, respectively. Upon completion of training, 34 patients were using tunneled IJ catheters, 10 using AV fistulas, and 1 using an AV graft. The IJ catheter exit site and sepsis infection rate was 0.35 and 0.49 episodes/1000 patient days, respectively. Average catheter life was 8.5 months with the longest 66.7 months and the shortest 0.2 months. The AV fistula and graft exit site and sepsis infection rates were 0.16 and 0 episodes/1000 patient days, respectively. Catheter complications included 1 episode of disconnect due to patient's failure to use locking device, 1 episode of central stenosis, and 1 episode of intracranial hemorrhage, due to prolonged INR, with resolution of symptoms.
Conclusion:  Data support that tunneled IJ catheters, AV fistulas, and AV grafts were effective and safe permanent accesses for patients on NHHD.  相似文献   

6.
The optimal cost-effective heparin concentration for locking tunneled cuffed hemodialysis catheters (TCC) is unclear. We performed a retrospective review of tissue plasminogen activator (tpa) use in TCC in 2 hemodialysis units that used different heparin concentrations for TCC lock to evaluate the effectiveness of lower dose heparin as a lock for TCC. Catheter blood flow rate per treatment, units of heparin given during treatments, patient hemoglobin values and use of warfarin, and tpa use were compared for all patients using TCC for at least 3 months in 2 in-center hemodialysis units between 11/04 and 5/05. Both units used the same type of catheters and biocompatible, non-re-use dialyzers. Unit A used heparin 1000 U/mL for catheter locks, and Unit B used heparin 10,000 U/mL for catheter locks. Twelve of 19 Unit A patients, tpa and 14 of 45 Unit B patients received intracatheter during the study period (p=0.0009). There were no differences in the number of patients on warfarin, treatment blood flow rate, or mean hemoglobin levels between the 2 groups. The mean heparin units given during hemodialysis treatments was higher in Unit A patients (3.92+/-2.2 vs. 3.83+/-2.5 1000 U, p=0.05). Assuming a 4.1 mL total catheter lumen volume, the cost of heparin 1000 U/mL lock was 0.20 dollars per treatment and heparin 10,000 U/mL cost 2.67 dollars/treatment; tpa cost 89.02 dollars/use. Using the 10,000 U/mL heparin as a catheter lock was associated with less frequent use of tpa. However, the significantly lower cost of the 1000 U/mL heparin could result in significant savings despite higher tpa use. This retrospective, uncontrolled study of a small number of patients suggests that comparing low and high heparin concentrations as a TCC lock would be worthwhile. Prospective studies would be helpful to define the most appropriate and cost-effective lock for TCC.  相似文献   

7.
Background: Lynchburg Nephrology Dialysis Incorporated started its nightly home hemodialysis (NHHD) program in September 1997. Purpose: The purpose of this study was to evaluate episodes of exit‐site infections, catheter sepsis, and safety and longevity of accesses for patients doing NHHD. Method: If internal jugular (IJ) catheter was chosen, the patient was started on 2 mg coumadin per day when catheter was placed. If catheter malfunctioned, it was blocked with a thrombolytic agent and coumadin was adjusted to meet a goal international normalized ratio (INR) of 1.5 to 2.25. If the problem persisted, the catheter was exchanged. For catheters, a threaded lock cannula (BD InterLink device, BD) was used to prevent air emboli and infections and a locking device was used to prevent disconnects. If arteriovenous (AV) fistula was used, four buttonholes were established using 16‐gauge needles. If AV graft was used, patients were taught the rope ladder cannulation technique using 16‐gauge needles. Results: As of September 1, 2003, 45 patients have completed training and have performed 27,063 treatments at home. Total catheter time at home was 930 months. Total AV fistula and AV graft times at home were 190 and 20 months, respectively. Upon completion of training, 34 patients were using tunneled IJ catheters, 10 were using AV fistulas, and 1 was using an AV graft. The IJ catheter exit‐site and sepsis infection rates were 0.35 and 0.52 episodes per 1000 patient‐days, respectively. Mean catheter life was 8.5 months with the longest being 66.7 months and the shortest being 0.2 months. The AV fistula and graft exit‐site and sepsis infection rates were 0.16 and 0 episodes per 1000 patient‐days, respectively. Catheter complications included one episode of disconnect due to patient's failure to use the locking device, one episode of central stenosis, and one episode of intracranial hemorrhage, due to prolonged INR, with resolution of symptoms. Conclusion: Data support the fact that tunneled IJ catheters, AV fistulas, and AV grafts are effective and safe permanent accesses for patients on NHHD.  相似文献   

8.
Elderly patients form the most rapidly expanding group of hemodialysis (HD) patients in Europe and the United States. There are initiatives to promote an increase in arteriovenous fistula (AVF) formation. There are concerns that elderly patients may have lower rates of surgical vascular access compared with younger patients due to risks of higher co-morbidities, surgical complications, and higher AVF nonuse rates. The aim of this study was to compare access-related survival and morbidity for dialysis catheters and AVFs and to evaluate the AVF nonuse rate in an elderly population. We have performed a retrospective analysis of access survival and morbidity in patients > or = 70 years of age, either on maintenance HD or predialysis with preemptive formation of surgical access. One hundred and forty-six patients had permanent HD access created during the 18-month study period, from 1 January 2006 to June 2007. There were 89 male and 57 female patients in whom 78 AVFs and 137 tunneled venous catheters were inserted. There was a significantly greater loss of vascular access due to infection in the catheter group compared with the AVF group (P<0.016). Access survival was also significantly prolonged in the AVF group (446 days, 95% confidence interval 405-487) compared with the catheter group (276 days, 95% confidence interval 240-313), P=0.001. The rate of nonuse of AVFs was low (16%). We conclude that an AVF is the preferred form of vascular access in elderly HD patients.  相似文献   

9.
Catheter‐related blood stream infection (CRBSI) is a major complication in hemodialysis patients. We assessed the efficacy of systemic daptomycin (DPT) plus DPT antibiotic lock therapy (DPT‐ALT) for catheter salvage in patients with Gram‐positive CRBSIs. This is a retrospective study of hemodialysis patients with tunneled and cuffed hemodialysis catheters. All patients were from a single institution in Taipei and received systemic DPT plus DPT‐ALT for the treatment of Gram‐positive CRBSI. Successful resolution of CRBSI was implemented. Resolution of fever within 48 hours, negative result of repeated blood cultures after resolution of fever, no clinical evidence of CRBSI relapse and no need for catheter removal were measured. Fifteen hemodialysis patients received DPT‐ALT for CRBSI, nine with coagulase‐negative Staphylococcus (CONS), two with methicillin‐resistant Staphylococcus aureus (MRSA), three with methicillin‐sensitive Staphylococcus aureus (MSSA) and one with polymicrobial infections. Systemic DPT plus DPT‐ALT cured 11 patients (73.3%). Treatment failed in all three MRSA cases (two with MRSA and one with MRSA + Enterococcus faecalis). Retrospective design and small sample size were the limitations of this study. Systemic DPT plus DPT‐ALT appears to be a promising treatment for CRBSI from CONS and MSSA, but not for MRSA CRBSI. Systemic DPT plus DPT‐ALT should be considered for patients with CRBSIs caused by certain species.  相似文献   

10.
Tunneled‐cuffed hemodialysis catheters are frequently used as long‐term vascular access in children due to the technical difficulties in constructing a fistula. Catheter‐related bacteremia (CRB) is still a major complication contributing to patient morbidity and loss of vascular access. Objective:  To investigate the microbiological characteristics of CRB in children on hemodialysis. Methods:  Chart review of 63 children who received hemodialysis with a tunneled‐cuffed catheter between January 1999 and December 2003 was performed. CRB was diagnosed when positive blood cultures were obtained in patients with symptoms of bacteremia, and without an identifiable source. Results:  During the 5 year period, a total of 251 CRB were detected with 313 bacterial and 2 candidal growths in the blood cultures. The distribution of gram positive (Gr+) and gram negative (Gr−) microorganisms and their sensitivity patterns are shown in the table. Coagulase negative Staphylococcus was the most common microorganism, and constituted 62% of all bacterial isolates. All Gr+ microorganisms were sensitive to vancomycin except one isolate of Enterococcus fecalis. Enterobacter cloacae was the most common Gr− microorganism, followed by Klebsiella pneumonia . The sensitivity of Gr− microorganisms to levofloxacin was 100%. The treatment course was complicated by the growth of a second microorganism in subsequent blood cultures in 24% of infections; 54% of these consisted of both Gr+ and Gr− isolates. The etiology of ESRD or the use of immunosuppressive agents had no effect on the occurrence of CRB. The average number of infections were 5.8/1000 catheter days, and the recurrence of CRB was more likely in patients who had two or more CRB in a year.  
  相似文献   

11.
Prevalent use of tunneled dialysis catheters can reach 30%. Infection remains the most serious catheter‐related problem. Catheter locks are increasingly used for prevention, but are not yet recommended either by the Food and Drug Association or European Medicines Agency, on the basis of increasing bacterial resistance or lock toxicity. The aim was to test safety and effectiveness of citrate. A prospective, interventional study was conducted to assess the safety and efficacy of a 30% citrate lock in preventing catheter‐related bacteremia (CRB). A total of 157 prevalent tunneled catheters were locked with citrate and prospectively followed during a 1‐year period. The primary endpoint was first CRB diagnosed according to two of the diagnostic criteria for Catheter Infection of Centers for Disease Control and Prevention (CDC), namely definite and probable infection. The CDC criterion of possible but not proved infection was not considered. This citrate lock cohort (n = 157) had 10 episodes of CRB. We observed 0.49 CRB episodes/1000 patient‐days and the mean infection‐free catheter day was 130.6 ± 100.9. No clinically relevant adverse events were observed. No proved tunnel or exit site infection was observed and no patients died because of CRB. Catheter obstruction episodes were reported on 69 occasions out of 14 catheters. These results were compared with an historical cohort from a previous study of catheter locking with low‐dose gentamicin and did not show significant difference in efficacy. Citrate lock is effective in preventing CRB. No toxicity was observed. The use of citrate lock may have advantages over antibiotic locks: No reported bacterial resistance, lower industrial cost, and less manipulation.  相似文献   

12.
Hemodialysis catheters are vital for chronic renal failure patients. Permanent tunneled dialysis catheters may be inserted through the jugular, subclavian, and femoral veins. In this paper, we aimed to present the computed tomography findings of a chronic renal failure patient who had referred our clinic with abdominal pain and dyspnea symptoms. This patient had a formerly inserted hemodialysis catheter for chronic renal failure and her catheter was found to be extending towards the middle hepatic vein with the tip leaning onto the parenchyma. Hemodialysis catheters can provide instant vascular access and can also be used for the consecutive procedures. Permanent hemodialysis catheters are ideal for long‐term use when placing an arteriovenous fistula is contraindicated or is no longer possible under conditions like advanced heart failure, peripheral artery disease or short life expectancy. The internal jugular, subclavian, the femoral veins, and the inferior vena cava can be used for catheter insertion. The tip of the catheters inserted in the neck or the thorax must extend to the vena cava superior. Catheter malposition may both lead to fatal outcomes and ineffective dialysis. It is important to obtain chest X‐rays after the procedure, particularly to detect catheter malposition.  相似文献   

13.
Background:  Soft, cuffed indwelling catheters are used for hemodialysis access and intravenous infusions. The majority of these catheters are removed as a result of infection caused by contamination of the catheter hub during the connection/disconnection procedures. To prevent clot formation in the lumen, these catheters are routinely "locked" with heparin or some other anticoagulant. None of the anticoagulants commonly used as locking solutions demonstrates any significant bactericidal properties. The primary goal of this study was the development of a catheter locking method that retains anticoagulant properties at the catheter tip and bactericidal properties at the catheter hub. The second goal was to find a solution that possesses excellent bactericidal properties but is not detrimental in the event of injection into the patient's blood stream. The bactericidal properties of acidified, concentrated saline (ACS) were compared to concentrated trisodium citrate and to commonly used bactericidal agents such as povidone iodine, sodium hypochlorite, and chlorhexidine.
Methods:  In preliminary studies, the rate of diffusion of solutes was measured in glass tubes. In another set of experiments, the mixing of two solutions (anticoagulant and bactericide) separated by an air bubble ("air-bubble method") was observed in stationary and moving systems. The final series of studies compared the bactericidal properties of ACS to other bactericidal solutions mentioned above.
Results:  The solutions diffused swiftly in the glass tubes, and by the third day, both solutions were mixed. The air-bubble method prevented mixing in both stationary and moving systems. The bactericidal properties of ACS were superior to all other tested solutions.
Conclusions:  The proposed method of catheter locking with anticoagulant at the catheter tip and ACS at the catheter hub separated by an air bubble is a promising technique and clinical studies are warranted.  相似文献   

14.
Catheter-related infections are a major cause of morbidity and mortality in hemodialysis (HD) patients. This study evaluated the utility of surveillance swab cultures (Ssc) of tunneled cuffed catheter (TCC) exit sites as a prediction and prevention strategy for infection. A 6-month prospective-controlled trial with 94 chronic HD patients with a TCC who received monthly Ssc and were stratified by dialysis day into topical therapy based on Ssc results (Group A) or no therapy (Group B). Outcomes were exit site infection (ESI) and catheter-associated bacteremia (CAB). The overall monthly prevalence of positive Ssc was 14.9%. There was no difference in the number of positive Ssc (17.7% vs. 11.6%, p > 0.05) or ESI (19.6% vs.16.3%, p > 0.05) between Groups A and B, respectively. Catheter-associated bacteremia was higher in Group A (17.7% vs. 4.7%, p = 0.05). There were significantly more ESI in the patients treated for a positive Ssc. In Group A, the incidence of ESI was significantly higher in those treated for a positive vs. negative Ssc (55% vs. 12%, p = 0.009) and CAB rates trended higher with positive Ssc (22.2% vs. 16.7%, p > 0.05). The strategy of treating positive surveillance cultures is not beneficial. Positive Ssc do not predict the occurrence of catheter-related infection, and treatment of these cultures may lead to increased infection rates.  相似文献   

15.
Central venous catheters (CVC) remain a frequently used form of vascular access in children receiving chronic hemodialysis (HD). Whereas standard dual-lumen catheters (DL) are used in many centers, the Tesio catheter has proven to be superior to the DL catheter in terms of catheter survival and infection rates in at least one pediatric study (Sheth RD et al . Am J Kidney Dis. 2001). Recently, the Ash Split catheter became available which, while similar to the Tesio internally, being comprised of 2 separate catheters, may be preferable because of the requirement for only one skin puncture for placement vs. two for the Tesio. However, no pediatric data pertaining to the Ash Split catheter have been published to date. Therefore, we reviewed and compared our experience with a small number of Ash Split (# 16) and Tesio (# 8) catheters used for semipermanent vascular access in our chronic HD population with reference to survival, infectious complications, patency, and dialysis adequacy. The results of this experience are as follows:  
  相似文献   

16.
The creation of an accurate functioning arteriovenous fistula has been a long-lasting problem in the hemodialysis setting. In spite of recent guidelines and largely because of the old age of the current dialysis population and a high incidence of diabetes mellitus, atherosclerosis, and related vascular problems, it is not always possible to create an adequate fistula. In that case, long-term tunneled indwelling central vein catheters are a frequently used alternative. Of the many possible complications related to venous access in hemodialysis patients, catheter dysfunction is the most prevalent. We report a 23-year-old female hemodialysis patient in whom such malfunctioning was followed by echocardiography that revealed a large right atrial thrombus (RAT) in close contact to the tip of a long-term indwelling catheter in the presence of a patent foramen ovale. Although RAT is a rare complication in hemodialysis patients, it has very specific therapeutic implications. The present patient underwent a successful surgical atrial thrombectomy. Our experience underscores that in cases of malfunctioning catheter, echocardiographic screening is mandatory.  相似文献   

17.
Sepsis is a common problem in patients who have cuffed catheters for hemodialysis. Line sepsis, however, has not often been associated with septic thrombophlebitis as seen in Lemierre syndrome. Thrombophlebitis of a central vein associated with catheter placement is extremely rare and when encountered is known to affect the femoral or the subclavian vein. Thrombophlebitis of the internal jugular vein after hemodialysis catheter placement has not been reported. We present the case of a woman with line sepsis who developed Lemierre syndrome, a serious complication of which the medical community should be aware. Lemierre syndrome requires a high index of suspicion for diagnosis and can have a fatal outcome if not treated with appropriate antibiotics.  相似文献   

18.
In this paper we wish to report our clinical experience with a new heparin-coated dialysis catheter with a symmetric tip. Over a 16-month period, 60 heparin-coated Tal Palindrome catheters were placed in 57 patients. Catheter patency, catheter-related complications, and reasons for catheter removal were recorded. The patient's initial cause of end-stage renal disease, underlying diseases, and site of access were recorded as well. Patients were specifically followed for development of heparin-induced thrombocytopenia. Patient ages were 34–91 (average 66). Fifty-four percent of patients had a history of diabetes. Sixty catheters were placed for a total of 5353 catheter-days. The average catheter indwell time was 107 days (range of 2–381 days). Catheter-related infection occurred in 6 patients over the study period, with a rate of 1.12/1000 catheter-days. Bacteremia occurred in 3 patients with a rate of 0.56/1000 catheter-days. Six catheters were removed or exchanged due to malfunction. There was no incidence of heparin-induced thrombocytopenia. Initial clinical experience with the heparin-coated Tal Palindrome hemodialysis catheter demonstrated safe, reliable use, and low infection rates.  相似文献   

19.
The replacement of tunneled hemodialysis catheters (CVCs) is a common procedure. In some cases, the CVC cannot be removed from the central vein because of tight adhesions to the surrounding fibrin sheath. A tight fibrin sheath leads to firm adherence between the catheter and the central veins or right atrial wall. Such stuck catheters cannot be removed from the central vein using standard methods. We present here a case demonstrating the successful removal of such a stuck CVC using the reverse Seldinger method.  相似文献   

20.
Cuffed catheters, although not ideal for long-term use, are now used more frequently due to an increase in the aging population, in whom the vessels are not suitable for either arteriovenous fistulas or polytetrafluoroethylene (PTFE) grafts. Infections and thrombosis remain the major causes for removal or change of catheters. We recently identified eight catheter defects that required replacement of catheters. Of these, two were due to patient negligence: one catheter was accidentally severed while the patient was shaving; the other was snipped during a haircut. One was believed to have a manufacturing defect. One catheter sustained needle-prick damage near the hub while irrigating the catheter. Two catheters were lost due to needle pricks during skin closure, and one catheter sustained similar damage while fixing the suture wing to the skin. The other two were damaged by suture material slicing through the lumen of the catheter as it expanded due to increased blood flow during repeated dialyses. Importantly, several of these injuries to the catheters were not immediately obvious and were detected only after repeated use of the catheters. Delayed bleeding of cuffed catheters necessitating change or removal has not been reported. Such bleeding may be due to manufacturing defects, patient carelessness, or iatrogenic causes. Avoiding the use of sutures can minimize the latter. Skin closure strips and a double transparent dressing may serve the same purposes, such as securing the catheter and aiding wound healing. In addition, these dressings have the added advantage of being waterproof, bacteria-proof, and cost effective.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号