首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Fenton-driven chemical regeneration of MTBE-spent GAC   总被引:1,自引:0,他引:1  
Huling SG  Jones PK  Ela WP  Arnold RG 《Water research》2005,39(10):2145-2153
Methyl tert-butyl ether (MTBE)-spent granular activated carbon (GAC) was chemically regenerated utilizing the Fenton mechanism. Two successive GAC regeneration cycles were performed involving iterative adsorption and oxidation processes: MTBE was adsorbed to the GAC, oxidized, re-adsorbed, oxidized, and finally re-adsorbed. Oxidant solutions comprised of hydrogen peroxide (H2O2) (1.7-2.0%) and FeSO4 x 7H2O (3 g/L) (pH 2.5), were recirculated through the GAC column (30% bed expansion). The regeneration efficiency after two full cycles of treatment was calculated to be 91%. The cost of H2O2 was 0.59 dollars/kg GAC (0.27 dollars/lb) per regeneration cycle. There was no loss of sorptive capacity. Small reductions in carbon surface area and pore volume were measured. The lack of carbon deterioration under aggressive oxidative conditions was attributed to the oxidation of the target contaminants relative to the oxidation of carbon surfaces. The reaction byproducts from MTBE oxidation, tertiary butanol and acetone, were also degraded and did not accumulate significantly on the GAC. Excessive accumulation of Fe on the GAC and consequent interference with MTBE sorption and carbon regeneration was controlled by monitoring and adjusting Fe in the oxidative solution.  相似文献   

2.
This study describes a process for water treatment by continuous adsorption and electrochemical regeneration using an air-lift reactor. The process is based on the adsorption of dissolved organic pollutants onto an adsorbent material (a graphite intercalation compound, Nyex®1000) and subsequent electrochemical regeneration of the adsorbent leading to oxidation of the adsorbed pollutant. Batch experiments were carried out to determine the adsorption kinetics and equilibrium isotherm for adsorption of a sample contaminant, the organic dye Acid Violet 17. The adsorbent circulation rate, the residence time distribution (RTD) of the reactor, and treatment by continuous adsorption and electrochemical regeneration were studied to investigate the process performance. The RTD behaviour could be approximated as a continuously stirred tank. It was found that greater than 98% removal could be achieved for continuous treatment by adsorption and electrochemical regeneration for feed concentrations of up to 300 mg L−1. A steady state model has been developed for the process performance, assuming full regeneration of the adsorbent in the electrochemical cell. Experimental data and modelled predictions (using parameters for the adsorbent circulation rate, adsorption kinetics and isotherm obtained experimentally) of the dye removal achieved were found to be in good agreement.  相似文献   

3.
Ania CO  Parra JB  Menéndez JA  Pis JJ 《Water research》2007,41(15):3299-3306
The purpose of this work was to explore the application of microwaves for the regeneration of activated carbons spent with salicylic acid, a metabolite of a common analgesic frequently found in wastewater from the pharmaceutical industry. The exhausted carbon was treated in a quartz reactor by microwave irradiation at 2450 MHz at different temperatures and atmospheres, the regeneration efficiency being highly dependent on the operating conditions. Quantitative desorption of the pollutant was achieved at high temperature and oxidizing atmosphere, with regeneration efficiencies as high as 99% after six cycles. The stripping efficiency was superior to 95% at high temperatures and decreased at 450 degrees C. The incomplete desorption of the adsorbate at low temperature was further confirmed by the changes in the porosity observed by N2 and CO2 adsorption isotherms. Hence, micropores remain blocked which results in a reduction in loading capacities in successive cycles.  相似文献   

4.
Electrochemical treatment of spent solution after EDTA-based soil washing   总被引:1,自引:0,他引:1  
Voglar D  Lestan D 《Water research》2012,46(6):1999-2008
The use of EDTA in soil washing technologies to remediate soils contaminated with toxic metals is prohibitive because of the large volumes of waste washing solution generated, which must be treated before disposal. Degradation of EDTA in the waste solution and the removal of Pb, Zn and Cd were investigated using electrochemical advanced oxidation processes (EAOP) with a boron-doped diamond anode (BDDA), graphite and iron anodes and a stainless-steel cathode. In addition to EAOP, the efficiency of electro-Fenton reactions, induced by the addition of H2O2 and the regulation of electrochemical systems to pH 3, was also investigated. Soil extraction with 15 mmol kg−1 of soil EDTA yielded waste washing solution with 566 ± 1, 152 ± 1 and 5.5 ± 0.1 mg L−1 of Pb, Zn and Cd, respectively. Treatments of the waste solution in pH unregulated electrochemical systems with a BDDA and graphite anode (current density 67 mA cm−2) were the most efficient and removed up to 98 ± 1, 96 ± 1, 99 ± 1% of Pb, Zn and Cd, respectively, by electrodeposition on the cathode and oxidatively degraded up to 99 ± 1% of chelant. In the electrochemical system with an Fe anode operated at pH 3, the chelant remained preserved in the treated solution, while metals were removed by electrodeposition. This separation opens up the possibility of a new EDTA recycling method from waste soil washing solution.  相似文献   

5.
电化学法再生活性炭试验研究   总被引:2,自引:0,他引:2  
采用电化学法再生吸附重金属离子的饱和活性炭,得出不同反应条件对活性炭再生效果的影响,并考察了电解时间、电解质投加量、搅拌状态、再生位置及辅助药剂等因素对活性炭再生率的影响。结果表明,再生液中硝酸的加入和饱和炭的再生位置对活性炭再生效果影响显著。电解时间为4h,NaCl投加量为5g,间歇搅拌,电解液中硝酸体积分数为0.5%时,电化学法再生活性炭可取得最佳效果。  相似文献   

6.
Electrochemical regeneration of Fe2+ in Fenton oxidation processes   总被引:8,自引:0,他引:8  
Qiang Z  Chang JH  Huang CP 《Water research》2003,37(6):1308-1319
This study is to establish optimal conditions for the minimization of iron sludge produced in Fenton oxidation processes by electro-regenerating Fe(2+) with constant potential (CPM) or constant current mode (CCM). Results indicate that the optimal cathodic potential for Fe(2+) regeneration is -0.1 V vs. the saturated calomel electrode (SCE) in terms of current efficiency. Keeping the initial Fe(3+) concentration ([Fe(3+)](0)) constant, the average current density produced at -0.1 V vs. SCE (CPM) is approximately equal to the optimal current density applied in the CCM. The suitable pH range is below the pH value determined by Fe(3+) hydrolysis. As expected, increasing cathode surface area and solution temperature notably increases Fe(2+) regeneration rate. At the optimal potential, the average current density increases linearly with [Fe(3+)](0), exhibiting a slope of 8.48 x 10(-3)(A/m(2))(mg/L)(-1). The average current efficiency varies with [Fe(3+)](0), e.g., 75% and 96-98% at 100 and > or = 500 mg/L [Fe(3+)](0), respectively. Once reaching 75% of Fe(2+) regeneration capacity, further regeneration becomes difficult due to Fe(3+) mass transfer limitation. Fe(2+) can also be effectively regenerated by dissolving iron sludge at low pH (usually 相似文献   

7.
The removal efficiency of several pharmaceutically active compounds from two different surface water types was investigated. Two different nanofiltration (NF) membranes (Trisep TS-80 and Desal HL) were first studied at low feed water recoveries (10%). In a second phase, the combination of an NF unit at higher feed water recovery (80%) with subsequent granular activated carbon (GAC) filtration of the permeate was investigated. Results indicate that removal of the selected pharmaceuticals with NF is mainly influenced by charge effects: negatively charged solutes are better removed, compared with uncharged solutes, which are, in turn, better removed compared with positively charged solutes. This latter trend is mainly due to charge attractions between the negatively charged membrane surface and positively charged solutes. Increasing feed concentrations of positively charged pharmaceuticals lead to increasing rejection values, due to membrane charge-shielding effects. The removal efficiency of pharmaceuticals with the combination NF/GAC is extremely high. This is mainly due to an increased adsorption capacity of the activated carbon since the largest part of the natural organic matter (NOM) is removed in the NF step. This NOM normally competes with pharmaceuticals for adsorption sites on the carbon.  相似文献   

8.
The fractal dimension of some commercial activated carbon (AC) was determined in the micro-, meso- and macropore range using mercury porosimetry and N(2) adsorption data. We studied the kinetic of adsorption of phenol, tannic acid and melanoidin on those ACs. The typical concentration-time profiles obtained here could be very well fitted by a general fractal kinetics equation q(n,alpha)(t)=q(e)[1-(1+(n-1)(t/tau(n,alpha))(alpha))(-1/(n-1))] deduced from recently new methods of analysis of reaction kinetics and relaxation. The parameter n is the reaction order, alpha is a fractional time index, q(e) measures the maximal quantity of solute adsorbed, and a "half-reaction time", tau(1/2), can be calculated, which is the time necessary to reach half of the equilibrium. The adsorption process on AC is clearly a heterogeneous process, taking place at the liquid-solid boundary, and the diffusion process occurs in a complex matrix with a fractal architecture as demonstrated here. In fact, these systems belong to what has been called "complex systems" and the fractal kinetic, which has been extensively applied to biophysics, can be a useful theoretical tool for study adsorption processes.  相似文献   

9.
R.J. Martin  W.J. Ng 《Water research》1985,19(12):1527-1535
This paper represents the second of a series of reports on the chemical regeneration of exhausted activated carbon following experimental research studies carried out at the University of Birmingham, U.K.

A wide range of regenerants, inorganic and organic, was evaluated in the treatment of carbon samples exhausted with 2-naphthol, 2-methoxyphenol, 2-chlorophenol, o-cresol and 2-nitrophenol, in order to compare the effects of the introduction of a second benzene ring (i.e. in effect the addition of C4H4, OCH3, Cl, CH3 and NO2 groups to phenol on susceptibility to desorption.

There was a marked correlation between decreasing molecular weight of adsorbate and decreasing value of regeneration efficiency; the smaller the adsorbate, the further it could penetrate into the micropores of the carbon thereby resisting displacement by the regenerant. Furthermore, it was observed that, in general, the smaller the organic regenerant the further it could penetrate into the micropores of the carbon and displace the adsorbate. These complementary observations indicate that where chemical reactions are unlikely between organic regenerant and adsorbate, the success of the regeneration process is governed by the mechanism of physical displacement of the adsorbate molecule by the organic solvent molecule. The importance of the molecular weights and sizes of the adsorbate and the solvent is thus confirmed.  相似文献   


10.
Thermal and ozone regenerations of granular activated carbons (GAC) used in the removal of phenol from aqueous solution have been studied. The phenol isotherms for virgin GAC could be well represented by the Langmuir equation. Direct ozonation of GAC introduced large amounts of acidic surface oxygen groups, which caused a decrease in the phenol uptake. Thermogravimetric methods were used to investigate the mechanism of phenol adsorption onto virgin and ozonated carbons. Thermal regeneration was carried out at 1123K using nitrogen (pyrolysis alone) or nitrogen and carbon dioxide (pyrolysis plus oxidation). Results showed that spent carbons do not recover their adsorption characteristics when heated under inert conditions whereas carbon dioxide regeneration was effective at about 15% wt burn-off. Regeneration of GAC was also carried out with ozone as oxidizing gas at room temperature. Ozone dose and the nature of GAC have much influence on the regeneration performance. For an individual GAC there exits an optimum ozone dose for which phenol is eliminated together with most of its oxidation by-products without incurring in carbon surface chemical alterations. However, if excessive ozone is applied some acidic surface groups are formed on the GAC, thereby decreasing the adsorption capacity for phenol. Results showed that spent carbons can recover most of their adsorption characteristics and specific surface areas when regenerated through a number of adsorption-ozone regeneration cycles.  相似文献   

11.
Activated carbon adsorption with attached microorganisms (biosorption) has been studied. The approaches available do not account for an efficient role of activated carbon under a steady state of purification, considering it (carbon) as a carrier of biofilm only. This paper considers the role of physico-chemical factors in order to clear up and assess a contribution of both physical adsorption and biodegradation (influencing effectiveness of the biosorption process) into the cumulative effect of the biosorption. The nonionic and anionic surfactants as well as phenol were used as sorbates. The impact of such essential physico-chemical factors of the adsorption process as the change in the Gibbs free energy (−ΔGa0) and the porous structure of the activated carbon on the effectiveness of the biosorption process has been established. The lower the contribution of the biological degradation into the biosorption process, the higher the −ΔGa0. As a result of the biodegradation process, products differing in their −ΔGa0 are generated on the active carbon. Separation of the biodegradation products characterized by different −ΔGa0 in the biosorption column filled by active carbon results in redistribution of contributions of physical adsorption and biodegradation into a cumulative effect. The micropores of the active carbon in the course of the biosorption/bioregeneration process are occupied by adsorbed molecules and are not subjected to biological regeneration.  相似文献   

12.
Saint Paul Regional Water Services (SPRWS) in Saint Paul, MN experiences annual taste and odor episodes during the warm summer months. These episodes are attributed primarily to geosmin that is produced by cyanobacteria growing in the chain of lakes used to convey and store the source water pumped from the Mississippi River. Batch experiments, pilot-scale experiments, and model simulations were performed to determine the geosmin removal performance and bed life of a granular activated carbon (GAC) filter-sorber. Using batch adsorption isotherm parameters, the estimated bed life for the GAC filter-sorber ranged from 920 to 1241 days when challenged with a constant concentration of 100 ng/L of geosmin. The estimated bed life obtained using the AdDesignS model and the actual pilot-plant loading history was 594 days. Based on the pilot-scale GAC column data, the actual bed life (>714 days) was much longer than the simulated values because bed life was extended by biological degradation of geosmin. The continuous feeding of high concentrations of geosmin (100-400 ng/L) in the pilot-scale experiments enriched for a robust geosmin-degrading culture that was sustained when the geosmin feed was turned off for 40 days. It is unclear, however, whether a geosmin-degrading culture can be established in a full-scale filter that experiences taste and odor episodes for only 1 or 2 months per year. The results of this research indicate that care must be exercised in the design and interpretation of pilot-scale experiments and model simulations for predicting taste and odor removal in full-scale GAC filter-sorbers. Adsorption and the potential for biological degradation must be considered to estimate GAC bed life for the conditions of intermittent geosmin loading typically experienced by full-scale systems.  相似文献   

13.
Electrochemical denitrificaton of simulated ground water   总被引:1,自引:0,他引:1  
Dash BP  Chaudhari S 《Water research》2005,39(17):4065-4072
Electrochemical denitrification of ground water was studied with an objective to maximize nitrate transformation to nitrogen gas. Aluminum, graphite, iron and titanium were selected as electrode materials. While aluminum, iron and titanium electrodes showed 70-97% nitrate reduction, with graphite electrode the removal was only 8%. Nitrate was transformed to ammonia with iron and aluminum electrodes but with titanium electrodes nitrogen was apparently the major end product. Iron electrodes exhibited the maximum reducing condition (ORP=-463mV) and titanium showed the minimum (ORP=-206mV). Nitrate reduction with titanium electrodes was retarded in the presence of chloride ions possibly due to formation of hypochlorite ions. The first-order nitrate transformation rate constant with respect to time decreased with decrease in current density. However, when the rate constant was expressed with respect to charge passed (Coulomb/l) it was nearly same under different experimental conditions (current density and pH). The study indicates that the process might be suitable for denitrification of drinking water.  相似文献   

14.
Hospital wastewater has been described as an important source of spreading pathogenic microorganisms in the environment. However, there are few studies reporting the presence and concentrations of gastroenteric viruses and hepatitis A viruses in these environmental matrices. The aim of this study was to assess the contamination by viruses responsible for acute gastroenteritis and hepatitis derived from hospital wastewater treatment plants (WWTPs). Rotavirus A (RV-A), human adenoviruses (HAdV), norovirus genogroup I and II (NoV GI/GII) and hepatitis A viruses (HAV) were detected and quantified in sewage samples from two WWTPs located in Rio de Janeiro (Brazil) that operates different sewage treatments. WWTP-1 uses an Upflow Anaerobic Sludge Blanket (UASB reactor) and three serial anaerobic filters while WWTP-2 uses aerobic processes, activated sludge with extended aeration and final chlorination of the effluents. Viruses’ detection was investigated by using conventional PCR/RT-PCR, quantitative real-time PCR (qPCR) and partial sequencing of the genome of the viruses detected. Rate of viruses detection ranged from 7% (NoV GI in WWTP-1) to 95% (RV-A in WWTP-2) and genome from all viruses were detected. The most prevalent genotypes were RV-A SG I, HAdV species D and F, NoV GII/4 and HAV subgenotype IA. Mean values of viral loads (genome copies (GC)/ml) obtained in filtered effluents from anaerobic process was 1.9 × 103 (RV-A), 2.8 × 103 (HAdV) and 2.4 × 103 (NoV GII). For chlorinated effluents from activated sludge process, the mean values of viral loads (GC/ml) was 1.2 × 105 (RV-A), 1.4 × 103 (HAdV), 8.1 × 102 (NoV GII) and 2.8 × 104 (HAV). Data on viral detection in treated effluents of hospital WWTPs confirmed the potential for environmental contamination by viruses and could be useful to establish standards for policies on wastewater management.  相似文献   

15.
Batch adsorption experiments using powdered activated carbon (PAC) to remove trace synthetic organic chemicals (SOCs) from water containing natural organic matter (NOM) were conducted. The percentage of SOC removed at any contact time and at any PAC dose was observed to be independent of the initial SOC concentration. Equations derived from the ideal adsorbed solution theory and the pore surface diffusion model validated this observation. For the strongly adsorbing SOCs (simazine and simetryn), the percentage of SOC removed was independent only at low initial SOC concentrations. The NOM fraction competing with the weakly adsorbing SOC (asulam) constituted a larger percentage of the total NOM than that competing with the strongly adsorbing SOCs. Although the adsorptive capacities of the SOCs were greatly reduced in water containing NOM compared with those in pure water, the change in the pore diffusion coefficient was insignificant. Therefore, NOM competed with the SOCs for adsorption sites, reducing the adsorptive capacity, but the amount of NOM loading was not so severe that it blocked or filled the pores, hindering the internal diffusion of the SOCs.  相似文献   

16.
Liquid-phase adsorption-desorption characteristics and ethanol regeneration efficiency of an activated carbon prepared from waste tires and a commercial activated carbon were investigated. Water vapor adsorption experiments reveal that both activated carbons showed hydrophobic surface characteristics. Adsorption experiments reveal that the prepared activated carbon possessed comparable phenol adsorption capacity as the commercial one but clearly larger adsorption capacity of two reactive dyes, Black 5 and Red 31. It was ascertained that the prepared activated carbon exhibited less irreversible adsorption of phenol and the two dyes than its commercial counterpart. Moreover, ethanol regeneration efficiency of the prepared AC saturated with either dye was higher than that of the commercial AC. Because of its superior liquid-phase adsorption-desorption characteristics as well as higher ethanol regeneration efficiency, the prepared activated carbon is more suitable for wastewater treatment, especially for adsorbing similarly bulky adsorbates.  相似文献   

17.
吴震华  朱止波 《山西建筑》2008,34(3):311-312
结合工程实例,介绍了在现场冷再生工程中,采用FWD测试弯沉并反算模量后,结合路面破损调查,对旧路面进行综合评价的方法,总结了FWD测试道路弯沉的优点,以推广FWD在道路工程中的应用。  相似文献   

18.
Zhang Y  Zhou JL 《Water research》2005,39(16):3991-4003
Endocrine disrupting chemicals (EDCs) are the focus of current environment concern, as they can cause adverse health effects in an intact organism, or its progeny, subsequent to endocrine function. The paper reports on the removal of estrone (E1) and 17beta-estradiol (E2) from water through the use of various adsorbents including granular activated carbon (GAC), chitin, chitosan, ion exchange resin and a carbonaceous adsorbent prepared from industrial waste. The results show that the kinetics of adsorption were adsorbent and compound-dependent, with equilibration being reached within 2 h for a waste-derived carbonaceous adsorbent to 71 h for an ion-exchange resin for E1, and within 7 h for the waste-derived carbonaceous adsorbent to 125 h for GAC for E2. Of all the adsorbents tested, the carbonaceous adsorbent showed the highest adsorption capacity, with a maximum adsorption constant of 87500 ml/g for E1 and 116000 ml/g for E2. The GAC also had a very high adsorption capacity for the two compounds, with a maximum adsorption constant of 9290 ml/g for E1 and 12200 ml/g for E2. The effects of some fundamental environmental parameters including adsorbent concentration, pH, salinity and the presence of humic acid and surfactant on adsorption were studied. The results show that adsorption capacity of activated carbon was decreased with an increase in adsorbent concentration and by the presence of surfactant and humic acid. The results have demonstrated excellent performance of a waste derived adsorbent in removing E1 and E2 from water, and indicated the potential of converting certain solid waste into useful adsorbents for pollution-control purposes.  相似文献   

19.
Indigenous bacteria are essential for the performance of drinking water biofilters, yet this biological component remains poorly characterized. In the present study we followed biofilm formation and development in a granular activated carbon (GAC) filter on pilot-scale during the first six months of operation. GAC particles were sampled from four different depths (10, 45, 80 and 115 cm) and attached biomass was measured with adenosine tri-phosphate (ATP) analysis. The attached biomass accumulated rapidly on the GAC particles throughout all levels in the filter during the first 90 days of operation and maintained a steady state afterward. Vertical gradients of biomass density and growth rates were observed during start-up and also in steady state. During steady state, biomass concentrations ranged between 0.8-1.83 x 10−6 g ATP/g GAC in the filter, and 22% of the influent dissolved organic carbon (DOC) was removed. Concomitant biomass production was about 1.8 × 1012 cells/m2h, which represents a yield of 1.26 × 106 cells/μg. The bacteria assimilated only about 3% of the removed carbon as biomass. At one point during the operational period, a natural 5-fold increase in the influent phytoplankton concentration occurred. As a result, influent assimilable organic carbon concentrations increased and suspended bacteria in the filter effluent increased 3-fold as the direct consequence of increased growth in the biofilter. This study shows that the combination of different analytical methods allows detailed quantification of the microbiological activity in drinking water biofilters.  相似文献   

20.
Perfluorooctanesulfonate (PFOS) and perfluorooctanoate (PFOA) have been recognized as global environmental pollutants. Although PFOS and PFOA have been detected in tap water from Japan and several other countries, very few studies have examined the fate, especially removal, of perfluorinated compounds (PFCs) in drinking water treatment processes. In this study, we analyzed PFOS and PFOA at every stages of drinking water treatment processes in several water purification plants that employ advanced water treatment technologies. PFOS and PFOA concentrations did not vary considerably in raw water, sand filtered water, settled water, and ozonated water. Sand filtration and ozonation did not have an effect on the removal of PFOS and PFOA in drinking water. PFOS and PFOA were removed effectively by activated carbon that had been used for less than one year. However, activated carbon that had been used for a longer period of time (>1 year) was not effective in removing PFOS and PFOA from water. Variations in the removal ratios of PFOS and PFOA by activated carbon were found between summer and winter months.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号