首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
HFO1234yf has been proposed for mobile air-conditioners due to its low global warming potential (GWP) and performance comparable to that of R134a. However, its performance is inferior to that of R410A. This makes it difficult to be applied to residential air-conditioners. In order to apply the low-GWP refrigerant to residential air-conditioners, refrigerant mixtures of HFO1234yf and R32 are proposed, and their flow boiling heat transfer performances were investigated at two mass fractions (80/20 and 50/50 by mass%) in a smooth horizontal tube with an inner diameter of 2 mm. The experiments were conducted under heat fluxes ranging from 6 to 24 kW/m2 and mass fluxes ranging from 100 to 400 kg/m2 s at the evaporation temperature of 15 °C. The measured heat transfer coefficients were compared with those of pure HFO1234yf and R32. The results showed that the heat transfer coefficients of the mixture with an R32 mass fraction of 20% were 10–30% less than those of pure HFO1234yf for various mass and heat fluxes. When the mass fraction of R32 increased to 50%, the heat transfer coefficients of the mixture were 10–20% greater than those of pure HFO1234yf under conditions of large mass and heat fluxes. Moreover, the heat transfer coefficients of the mixtures were about 20–50% less than that of pure R32. The performances of the mixtures were examined at different boiling numbers. For refrigerant mixture HFO1234yf and R32 (80/20 by mass%), the nucleate boiling heat transfer was noticeably suppressed at low vapor quality for small boiling numbers, whereas the forced convective heat transfer was significantly suppressed at high vapor quality for large boiling numbers. This indicates that the heat transfer is greatly influenced by the mass diffusion resistance and temperature glide of the mixture.  相似文献   

2.
This paper presents some preliminary experimental measurements collected during flow boiling heat transfer of low global warming potential refrigerant R1234yf in an asymmetrically heated rectangular plain channel. The asymmetrical heating is the common boundary condition that occurs in many different applications, for instance, in almost all the electronic devices, which are now pushing the cooling demands to more and more greater requirements. From this standpoint, the analysis of the flow boiling heat transfer of efficient and eco-friendly refrigerants can open new frontiers to the electronic thermal management. The experimental measurements were carried out at the Department of Industrial Engineering of the University of Padova by imposing two different heat fluxes, 50 and 100 kW m?2, at a constant saturation temperature of 30°C; the refrigerant mass velocity was varied between 50 and 200 kg m?2 s?1, while the vapor quality varied from 0.2 to 0.95. The developed measuring technique permits to estimate the flow boiling heat transfer coefficient and the critical value of vapor quality at the onset of the dryout.  相似文献   

3.
The heat transfer characteristics of condensation for R410A inside horizontal microfin tubes with 0° and 18° helical angles were investigated numerically. The numerical data fit well with the experimental results and with the empirical correlations. The results indicate that local heat transfer coefficients increase with increasing mass flux, vapor quality, and helical angle. The heat transfer enhancement in the helical microfin tubes is more pronounced at higher mass flux and vapor quality. The centrifugal force induced by the microfin with a 18° helical angle tends to spread the liquid from the bottom to the top, leading to a nearly symmetrical liquid–vapor interface during condensation. Swirling flows in the liquid phase are observed in the tube with the 18° helical angle, but the liquid phase tends to flow to the bottom due to gravity in the tube with the 0° helical angle.  相似文献   

4.
《传热工程》2012,33(3):288-301
Abstract

Wettability plays an important role during flow boiling inside micro and mini channels. The present work focuses on the flow boiling heat transfer characteristics inside copper minitube (inner diameter of 3?mm) coated internally to render the inside surface nearly hydrophobic. Electroless Galvanic Deposition technique is employed for hydrophobic coating inside the copper tube. Both single phase heat transfer and two-phase flow boiling heat transfer and pressure drop characteristics were investigated in regular and internally coated hydrophobic copper minitubes. The experiments were performed with deionized water as a working fluid and the mass flux was varied from 100 to 650?kg/m2s. The two-phase heat transfer characteristics was observed to be both functions of mass flux as well as heat flux. The two phase heat transfer has been observed to be augmented due to the wettability within the tubes. The two-phase pressure drop has also been observed to increase when compared to the regular, uncoated tube; however, the proportional increment is lower than the augmentation achieved in two-phase heat transfer. The enhanced heat transfer effects observed have been explained on the basis of wetting physics.  相似文献   

5.
This article presents new experimental critical heat flux results under saturated flow boiling conditions for a macro-/microscale tube. The data were obtained in a horizontal 2.20-mm inside diameter stainless-steel tube with heating lengths of 361 and 154 mm, R134a and R245fa as working fluids, mass velocities ranging from 100 to 1500 kg/m2-s, critical heat flux from 25 to 300 kW/m2, exit saturation temperatures of 25, 31, and 35°C, and critical vapor qualities ranging from 0.55 to 1. The experimental results show that critical heat flux (CHF) increases with increasing mass velocity and inlet subcooling but decreases with increasing saturation temperature and heated length. The data also indicated a higher CHF for R245fa when compared with R134a at similar conditions. The experimental data were compared against four CHF predictive methods and the results of the comparisons are reported.  相似文献   

6.
Two-phase frictional pressure drop characteristics of R410A/POE oil mixture flow boiling inside a straight micro-fin tube with the outside diameter of 7.0 mm were investigated experimentally. Experimental parameters include the evaporation temperature of 5 °C, the mass flux from 200 to 400 kg/(m2 s), the heat flux from 7.56 to 15.12 kW/m2, the inlet vapor quality from 0.2 to 0.7, and nominal oil concentration from 0% to 5%. The test results show that frictional pressure drop of R410A/POE oil mixture increases with the mass flux, the presence of oil enhances two-phase frictional pressure drop, and the effect of oil on frictional pressure drop is more evident at higher vapor qualities where the local oil concentrations are higher. New correlations to predict the local frictional pressure drop of R410A/POE oil mixture flow boiling inside the straight micro-fin tube are developed based on local properties of refrigerant–oil mixture, and the measured local frictional pressure drop is well correlated with the empirical correlations proposed by the authors.  相似文献   

7.
Heat transfer and pressure drop characteristics of four microfin tubes were experimentally investigated for condensation of refrigerants R134a, R22, and R410A in four different test sections. The microfin tubes examined during this study consisted of 8.92, 6.46, 5.1, and 4 mm maximum inside diameter. The effect of mass flux, vapor quality, and refrigerants on condensation was investigated in terms of the heat transfer enhancement factor and the pressure drop penalty factor. The pressure drop penalty factor and the heat transfer enhancement factor showed a similar tendency for each tube at given vapor quality and mass flux. Based on the experimental data and the heat-momentum analogy, correlations for the condensation heat transfer coefficients in an annular flow regime and the frictional pressure drops are proposed.  相似文献   

8.
Experiments on transition and flow boiling heat transfer with refrigerant R114 inside a horizontal tube were performed at bubble flow, critical heat flux and in the transition region between bubble flow and film boiling at mass fluxes between 1200 and 4000 kg/m2 s and in the pressure range between 5 and 15 bar. In comparison with pool boiling bubble flow heat transfer depends essentially on the mass flow rates and on the vapor quality. The critical heat flux depends less on the temperature difference than in pool boiling heat transfer and exhibits a maximal and a minimal value as a function of the pressure. The critical heat flux increases with mass flow rate as already shown by Collier. In the region of transition boiling the heat flux over the difference between wall and saturation temperature approaches a horizontal curve. Therefore in this region an evaporator may always be operated under stable conditions and burn out does not occur.  相似文献   

9.
Experimental heat transfer studies during condensation of pure R-134a vapor inside a single microfin tube have been carried out. The microfin tube has been provided with different tube inclination angles of the direction of fluid flow from horizontal, α. The data are acquired for seven different tube inclinations, α, in a range of −90 to +90° and three mass velocities of 54, 81, and 107 kg/m2-s for each inclination angle during condensation of R-134a vapor. The experimental results indicate that the tube inclination angle of, α, affects the condensation heat transfer coefficient in a significant manner. The highest heat transfer coefficient is attained at inclination angle of α = +30°. The effect of inclination angle, α, on heat transfer coefficient, h, is more prominent at low vapor quality and mass velocity. A correlation has also been developed to predict the condensing side heat transfer coefficient for different vapor qualities and mass velocities.  相似文献   

10.
In this study, experiments were performed to examine characteristics of flow boiling heat transfer and pressure drop of a low global warming potential refrigerant R32 flowing in a horizontal copper circular tube with 1.0 mm inside diameter for the development of a high-performance heat exchanger using small-diameter tubes or minichannels for air conditioning systems. Axially local heat transfer coefficients were measured in the range of mass fluxes from 30 to 400 kg/(m2·s), qualities from 0.05 to 1.0, and heat fluxes from 2 to 24 kW/m2 at the saturation temperature of 10°C. Pressure drops were also measured in the rage of mass fluxes from 30 to 400 kg/(m2·s) and qualities from 0.05 to 0.9 at the saturation temperature of 10°C under adiabatic condition. In addition, two-phase flow patterns were observed through a sight glass fixed at the tube exit with a digital camera. The characteristics of boiling heat transfer and pressure drop were clarified based on the measurements and the comparison with data of R410A obtained previously. Also, measured heat transfer coefficients were compared with two existing correlations.  相似文献   

11.
Experimental two-phase frictional pressure drop and flow boiling heat transfer results are presented for a horizontal 2.32-mm ID stainless-steel tube using R245fa as working fluid. The frictional pressure drop data was obtained under adiabatic and diabatic conditions. Experiments were performed for mass velocities ranging from 100 to 700 kg m?2 s?1, heat flux from 0 to 55 kW m?2, exit saturation temperatures of 31 and 41°C, and vapor qualities from 0.10 to 0.99. Pressures drop gradients and heat transfer coefficients ranging from 1 to 70 kPa m?1 and from 1 to 7 kW m?2 K?1 were measured. It was found that the heat transfer coefficient is a strong function of the heat flux, mass velocity, and vapor quality. Five frictional pressure drop predictive methods were compared against the experimental database. The Cioncolini et al. (2009) method was found to work the best. Six flow boiling heat transfer predictive methods were also compared against the present database. Liu and Winterton (1991), Zhang et al. (2004), and Saitoh et al. (2007) were ranked as the best methods. They predicted the experimental flow boiling heat transfer data with an average error around 19%.  相似文献   

12.
This paper describes an experimental setup for the investigation of two-phase heat transfer inside microchannels and reports local heat transfer coefficients measured during flow boiling of HFC-245fa in a 0.96-mm-diameter single circular channel. The test runs have been performed during vaporization at around 1.85 bar, corresponding to 31°C saturation temperature. As a peculiar characteristic of the present technique, the heat transfer coefficient is not measured by imposing the heat flux; instead, the boiling process is governed by controlling the inlet temperature of the heating secondary fluid. In the data, mass velocity ranges between 200 and 400 kg m?2 s?1, with heat flux varying from 5 to 85 kW m?2 and vapor quality from 0.05 up to 0.8. Since these data are not measured at uniform heat flux conditions, a proper analysis is performed to enlighten the influence of the different parameters and to compare the present data to those obtained when the heat flux is imposed. Besides, the test runs have been carried out in a double mode: by increasing the water-to-refrigerant temperature difference and by decreasing it. Finally, the experimental data are compared to models available in the literature for predicting the heat transfer coefficients inside microchannels.  相似文献   

13.
The boiling heat transfer of refrigerant R-134a flow in horizontal small-diameter tubes with inner diameter of 0.51, 1.12, and 3.1 mm was experimentally investigated. Local heat transfer coefficient and pressure drop were measured for a heat flux ranging from 5 to 39 kW/m2, mass flux from 150 to 450 kg/m2 s, evaporating temperature from 278.15 to 288.15 K, and inlet vapor quality from 0 to 0.2. Flow patterns were observed by using a high-speed video camera through a sight glass at the entrance of an evaporator. Results showed that with decreasing tube diameter, the local heat transfer coefficient starts decreasing at lower vapor quality. Although the effect of mass flux on the local heat transfer coefficient decreased with decreasing tube diameter, the effect of heat flux was strong in all three tubes. The measured pressure drop for the 3.1-mm-ID tube agreed well with that predicted by the Lockhart–Martinelli correlation, but when the inner tube diameter was 0.51 mm, the measured pressure drop agreed well with that predicted by the homogenous pressure drop model. With decreasing tube diameter, the flow inside a tube approached homogeneous flow. The contribution of forced convective evaporation to the boiling heat transfer decreases with decreasing the inner tube diameter.  相似文献   

14.
Hideo Mori 《传热工程》2016,37(7-8):686-695
For the development of a high-performance heat exchanger using small channels or minichannels for air-conditioning systems, it is necessary to clarify the characteristics of vapor‐liquid two-phase flow and heat transfer of refrigerants in small-diameter tubes. In this keynote paper, the related research works that have already been performed by the author and coworkers are introduced. Based on the observations and experiments of R410A flowing in small-diameter circular and noncircular tubes with hydraulic diameter of about 1 mm, the characteristics of vapor‐liquid two-phase flow pattern and boiling heat transfer were clarified. In low quality or mass flux and low heat flux condition, in which the flow was mainly slug, the “liquid film conduction evaporation” heat transfer peculiar to small-diameter tubes prevailed and exhibited considerably good heat transfer compared to nucleate boiling and forced convection evaporation heat transfer. The effects of the tube cross-sectional shape and flow direction on the heat transfer primarily appeared in the region of the “liquid film conduction evaporation” heat transfer. A new heat transfer correlation considering all of three contributions has been developed for small circular tubes.  相似文献   

15.
Cheol Huh  Moo Hwan Kim 《传热工程》2013,34(8-9):730-737
The boiling heat transfer and two-phase pressure drop of water in a microscale channel were experimentally investigated. The tested horizontal rectangular microchannel had a hydraulic diameter of 100 μ m and length of 40 mm. A series of microheaters provided heat energy to the working fluid, which made it possible to control and measure the local thermal conditions in the direction of the flow. Both the microchannel and microheaters were fabricated using a micro-electro-mechanical systems (MEMS) technique. Flow patterns were obtained from real-time flow visualizations made during the flow boiling experiments. Tests were performed for mass fluxes of 90, 169, and 267 kg/m2s and heat fluxes from 200 to 500 kW/m2. The effects of the mass flux and vapor quality on the local flow boiling heat transfer coefficient and two-phase frictional pressure gradient were studied. The evaluated experimental data were compared with existing correlations. The experimental heat transfer coefficients were nearly independent of the mass flux and vapor quality. Most of the existing correlations did not provide reliable heat transfer coefficient predictions for different vapor quality values, nor could they predict the two-phase frictional pressure gradient except under some limited conditions.  相似文献   

16.
This study experimentally investigated the critical heat flux(CHF) of departure from nucleate boiling(DNB) of water flowing under near-critical pressures in a 2 m-long vertical upward rifled tube with the size of Φ35 × 5.67 mm. Operating conditions included pressures of 18–21 MPa, mass fluxes of 475–1000 kg·m~(-2)·s~(-1), inlet subcooling temperatures of 3–5°C, and wall heat fluxes of 40–960 kW·m~(-2). Tube wall temperature distribution and heat transfer performance in different test conditions were obtained. The effects of the operating parameters on CHF were analyzed. Four heat transfer coefficient correlations were evaluated against our experimental data for further investigation of the two-phase heat transfer characteristics. A heat transfer correlation based on Martinelli number utilized in two-phase region and two empirical correlations used to predict the CHF in rifled tube at near-critical pressures were proposed. Meanwhile, experimental CHF data in rifled tube were compared with six widely used correlations and a CHF look-up table. The CHF enhancement effect in rifled tube is obvious as compared with the CHF data in smooth tube. Results show that DNB occurs at low vapor quality and subcooled region in the rifled tube at near-critical pressures. The increase in pressure leads to the early occurrence of DNB and the decrease in CHF, whereas the increase in mass flux delays the occurrence of DNB and results in the increase in CHF. DNB presents a tendency to move toward the inlet of the rifled tube. At individual operating conditions, DNB and dryout coexist at different sections of the rifled tube.  相似文献   

17.
In this paper we present experimental data on heat transfer and pressure drop characteristics at flow boiling of refrigerant R-134a in a horizontal microchannel heat sink. The primary objective of this study was to experimentally establish how the local heat transfer coefficient and pressure drop correlate with the heat flux, mass flux, and vapor quality. The copper microchannel heat sink contains 21 microchannels with 335 × 930 μm2 cross section. The microchannel plate and heating block were divided by the partition wall for the local heat flux measurements. Distribution of local heat transfer coefficients along the length and width of the microchannel plate was measured in the range of external heat fluxes from 50 to 500 kW/m2; the mass flux varied within 200–600 kg/m2-s, and pressure varied within 6–16 bar. The obvious impact of heat flux on the magnitude of heat transfer coefficient was observed. It showed that nucleate boiling is the dominant mechanism for heat transfer. A new model of flow boiling heat transfer, considering nucleate boiling suppression and liquid film evaporation, was proposed and verified experimentally in this paper.  相似文献   

18.
ABSTRACT

The paper presents thermal and flow analyses of the boiling process of R507, R410 and R407 C refrigerants inside vertical tubes (21 mm) with coiled-wire inserts and various coil diameters (20; 20.5 mm), coil pitches (26; 44 mm) and wire diameters (1.5; 2 mm). The study differs from other publications as regards the conditions under which the experiment was conducted. It focuses on the boiling process in two long vertical tube sections (2 m), paired in an in-line arrangement. The study was conducted within a moderate range of mass flux densities 80–240 kgm?2s?1 and at low heat flux densities 5–11 kWm?2, corresponding to the operating conditions of air coolers. The study examined the influence of vapour quality, mass flux density, geometrical parameters of the inserts and the impact of temperature glide on heat transfer coefficient and flow resistance increases as compared with a plain tube. The obtained increase ratios of heat transfer coefficients amounted to 1.1-1.7 for an azeotropic agent and to 1.1-1.3 for zeotropic agents, with the relative increase in flow resistances amounting to 1.8-4.5. New equations are proposed in the paper for the calculation of heat transfer coefficient and flow resistance values for boiling inside vertical tubes with spiral inserts.  相似文献   

19.
ABSTRACT

Heat transfer and pressure drop characteristics of condensation for R410A inside horizontal tubes (dh = 0.25, 1, and 2 mm) at saturation temperatures Tsat = 310, 320, and 330 K are investigated numerically. The results indicate that local heat transfer coefficients and pressure drop gradients increase with increasing mass flux and vapor quality and with decreasing tube diameter and saturation temperature. Liquid film thickness also increases with increasing saturation temperature because of the lower surface tension at higher saturation temperature. When gravity dominates the condensation process, a vortex with its core lying at the bottom of the tube is found in the vapor phase region. For the annular flow regime, stream traces point from the symmetry plan to the liquid–vapor interface, where the vapor phase becomes the liquid phase. Numerical heat transfer coefficients and pressure drop gradients are compared to available empirical correlations. Two new models for heat transfer coefficients and frictional pressure drop gradients are developed based on the numerical work.  相似文献   

20.
Abstract

A simple predictive technique for heat transfer during film boiling in tubes is presented. This technique is based on the two-step model and consists of a graphic correlation for nonequilibrium quality and an equation for liquid droplet cooling at high pressures. It has been developed from and verified with data for water, nitrogen, para-hydrogen, R-113, methane, and propane. The range of data includes equilibrium qualities from 0.1 to 2.9, pressures from 1.4 to 215 bar, reduced pressures from 0.01 to 0.97, mass flux from 30 to 3442 kg/m2 s, tube diameters from 2.5 to 14.9 mm, heat flux from 0.012 to 2.1 [Macute]W/m2, and wall temperatures from 81 to 1112 K. For all 722 data points analyzed, heat transfer coefficients based on actual vapor temperatures are correlated with a root-mean-square error of 15%.  相似文献   