首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到14条相似文献,搜索用时 0 毫秒
1.
This paper reports a numerical study on the process from normal operating conditions to rotating stall in a cen-trifugal compressor with vaned diffuser.The purpose is to better understand the flow characteristics near stallpoint under the interactions between centrifugal impeller and vaned diffuser.Numerical results show that undercertain conditions just preceding stall point the tip leakage vortex begins to fluctuate at roughly half of the bladepassing frequency.This phenomenon is similar to rotating instability in axial compressors.With the flow rate re-duced further the impeller stalls and five stall cells propagating at a frequency of 85 percent of impeller rotationspeed are found.  相似文献   

2.
The unsteady inner flow structure of a single-stage axial flow compressor under the coexisting conditions of surge and rotating stall was experimentally investigated via detailed measurements of the unsteady characteristics and the internal flow velocity fluctuations. The main relevant feature of the tested compressor is a shock tube with a capacity tank connected in series to the compressor outlet through slits and a concentric duplex pipe: surge and rotating stall can both be generated by connecting the shock tube. Research attention is focused on the unsteady behavior of a rotating stall during the surge cycle. The size of the rotating stall cell during the recovery process of an irregular surge cycle was experimentally determined by the circumferential flow velocity fluctuations ahead of the rotor blade. The results suggested that the size of the rotating stall cell at the switching point of the performance curve between large and small cycles is considered to be the key parameter in determining the following surge cycle. In addition, the surge cycle is largely influenced by the unsteady behavior of the rotating stall cell.  相似文献   

3.
为研究间隙变化对轴流压气机转子近失速工况下叶顶流场结构的影响,以轴流压气机转子Rotor37为研究对象,对其叶顶流场进行定常和非定常的数值模拟。计算结果表明:随着叶顶间隙的减小,压气机的总压比和等熵效率均有所提高,稳定运行范围扩大;2倍设计间隙下,叶尖泄漏涡经激波作用后发生膨胀破碎,堵塞来流通道,诱发压气机堵塞失速;0.5倍设计间隙下,吸力面流动分离加剧,发生回流,部分回流与来流在压力面前缘上游发生干涉,进口堵塞加剧,致使部分来流从前缘溢出,导致压气机叶尖失速;不同间隙下压气机失速过程的主导因素不同,大间隙下失速由叶尖泄漏涡破碎的非定常波动引起,小间隙下失速主要由流动分离引发的周期性前缘溢流所主导。  相似文献   

4.
In order to clarify the natures of a rotating stall cell, the experimental investigation was carried out in a high specific-speed diagonal flow fan. The pressure field on the casing wall and the velocity fields at the rotor inlet and outlet were measured under rotating stall condition with a fast response pressure transducer and a single slant hot-wire probe, respectively. The data were processed using the "Double Phase-Locked Averaging (DPLA)" technique, which enabled to obtain the unsteady flow field with a rotating stall cell in the relative co-ordinate system fixed to the rotor. As a result, the structure and behavior of the rotating stall cell in a high specific-speed diagonal flow fan were shown.  相似文献   

5.
The near casing flow fields inside the rotor passage of a 1.5 stage axial compressor with different blade-loading levels and tip gap sizes were measured by using stereoscopic particle image velocimetry (SPIV). Based on a carefully defined blockage extracting method, the variations of blockage parameter inside the blade passage were analyzed. It was found that the variation of blockage parameter appeared as a non-monotonic behavior inside the blade passage in most cases. This non-monotonic behavior became much more remarkable as the blade loading increases or mass flow rate decreases.The variations of the blockage parameter inside the blade passage had close relation to the evolutionary procedures of the tip leakage vortex (TLV). The destabilization of the TLV caused a rapid increasing of the blockage parameter. After the TLV lost the features of a concentrated streamwise vortex, the blockage parameter usually got a peak value. And then, because of the intense turbulent mixing between the TLV low momentum flow and its surrounding flows, the flow deficit inside the TLV recovered.  相似文献   

6.
The structure and behavior of rotating stall cell were experimentally clarified in a diagonal flow fan. The specific-speed of the fan was 1140 (r/min, m3/min, m), and the total pressure-rise coefficient at design flow-rate was 0.345. The static pressure on outer casing wall and the total pressure at rotor inlet and outlet were measured using a high response pressure transducer. The measured data were processed by the use of DPLA technique, and the structure and behavior of rotating stall cell were obtained. As a result, the stall cell extent for circumferential and spanwise direction and the pressure distributions inside stall cell were clarified. The details of stall cell propagation were also shown.  相似文献   

7.
The unsteady flow structure between rotor blade-to-blade passages in a three-stage axial flow compressor is experimentally investigated by detailed measurements of unsteady performance characteristics,casing wall pressure fluctuations and their wavelet analyses.The main feature of the test compressor is a capacity tank facility connected in series to the compressor outlet in order to supply compression and/or expansion waves from downstream of the compressor.Research attention is focused on the post-stall characteristics of the surge and rotating stall which occur simultaneously.The influence of the compressor operating point on the unsteady performance curve shows that the surge cycle changes irregularly depending on the steady-state resistance characteristics,and the results of the wavelet analyses of the wall pressure fluctuations suggest that the surge cycle may selectively be determined by the rotating stall cell structure within the rotor cascade.  相似文献   

8.
This paper presents the investigation of the effects of suction side squealer tip on the performance of an axial compressor.The experiment is carried out in a single-stage large-scale low-speed compressor.The investigated tip geometries include flat tip as the baseline and suction side squealer tip.The tip clearance of the baseline is 0.5% of the blade span.The static pressure rise characteristic curves of both the rotor and the stage are measured.The flow field at the exit of the rotor is measured by a 5-hole probe under design and off-design conditions.The static pressure on the endwall of the rotor passage is also obtained.The results show that the pressure rise characteristic curves obtained by measuring the pressure on the end wall are almost unchanged by using the suction side squealer tip.The measuring results of the 5-hole probe show the static pressure and the total pressure in tip region is slightly greater than that of the flat tip at the design condition at the exit of the rotor.It also leads to greater av-eraged static pressure rise and total pressure.At the near stall condition,the averaged static pressure and total pressure is lower than the baseline which is related to the redistribution of the blade load caused by the suction side squealer tip.  相似文献   

9.
For convenience of both measurement and adjusting the clearance size and incidence, the current research is mainly conducted by experiments on an axial compressor linear cascade. The characteristics and the condition under which the unsteadiness of tip leakage flow would occur were investigated by dynamic measuring in different clearances, inlet velocities and incidences. From the experiment it is found that increasing tip clearance size or reducing rotor tip incidence can affect the strength of the tip clearance flow. Then the experimental results also indicate the tip leakage shows instability in certain conditions, and the frequency of unsteadiness is great influenced by inflow angle. The condition of occurrence of tip leakage flow unsteadiness is when the leakage flow is strong enough to reach the pressure side of the adjacent blade. The main cause of tip leakage flow unsteadiness is the tip blade loading.  相似文献   

10.
A numerical study is conducted to investigate the influence of inlet flow condition on tip leakage flow (TLF) and stall margin in a transonic axial rotor.A commercial software package FLUENT,is used in the simulation.The rotor investigated in this paper is ND_TAC rotor,which is the rotor of one-stage transonic compressor in the University of Notre Dame.Three varied inlet flow conditions are simulated.The inlet boundary condition with hub distortion provides higher axial velocity for the incoming flow near tip region than that for the clean inflow,while the incoming main flow possesses lower axial velocity near the tip region at tip distortion inlet boundary condition.Among the total pressure ratio curves for the three inlet flow conditions,it is found that the hub dis-torted inlet boundary condition improves the stall margin,while the tip distorted inlet boundary condition dete-riorates compressor stability.The axial location of interface between tip leakage flow (TLF) and incoming main flow (MF) in the tip gap and the axial momentum ratio of TLF to MF are further examined.It is demonstrated that the axial momentum balance is the mechanism for interface movement.The hub distorted inflow could de-crease the axial momentum ratio,suppress the movement of the interface between TLF and MF towards blade leading edge plane and thus enhance compressor stability.  相似文献   

11.
Unsteady behaviors as well as unsteady cascade flow fields of a single-stage axial flow compressor were experimentally investigated by detail measurements of unsteady performance characteristics and casing wall pressure and internal flow velocity fluctuations. The main feature of the test compressor is a capacity tank connected directly to the compressor outlet in series through slits and a concentric duplex pipe, and also jet nozzles in order to inject compressed air toward the rotor tip region. Research attention is focused on the post-stall characteristics of surge and rotating stall which occur simultaneously. When the compressor was connected to the capacity tank, surge was generated with rotating stall in accordance with the capacitance increment of whole compressor system. The surge behavior changed irregularly with throttling valve installed behind the compressor, and several types of surge cycles were observed. In addition, the surge cycle changed by jet injection to the rotor tip region. The results suggested that the blockages of the cascade flow which were generated by a stall cell play an important role in deciding the surge behaviors.  相似文献   

12.
<正>It is well known that tip leakage flow has a strong effect on the compressor performance and stability. This paper reports on a numerical investigation of detailed flow structures in an isolated transonic compressor rotor-NASA Rotor 37 at near stall and stalled conditions aimed at improving understanding of changes in 3D tip leakage flow structures with rotating stall inception.Steady and unsteady 3D Navier-Stokes analyses were conducted to investigate flow structures in the same rotor.For steady analysis,the predicted results agree well with the experimental data for the estimation of compressor rotor global performance.For unsteady flow analysis, the unsteady flow nature caused by the breakdown of the tip leakage vortex in blade tip region in the transonic compressor rotor at near stall condition has been captured with a single blade passage.On the other hand, the time-accurate unsteady computations of multi-blade passage at near stall condition indicate that the unsteady breakdown of the tip leakage vortex triggered the short length-scale-spike type rotating stall inception at blade tip region.It was the forward spillage of the tip leakage flow at blade leading edge resulting in the spike stall inception. As the mass flow ratio is decreased,the rotating stall cell was further developed in the blade passage.  相似文献   

13.
Numerical investigations of the Darmstadt transonic single stage compressor (DTC), in the Rotor1-Stator1 configuration, aimed at advancing the understanding of the effect of different rotor tip gaps and transition modelling on the blade surfaces are presented. Steady three dimensional Reynolds Averaged Navier Stokes (RANS) simulations were performed to obtain the flow fields for the different configurations at different operating conditions using the RANS-Solver TRACE. The stage geometry and the multi-block structured grid were generated by G3DMESH and a grid sensitivity analysis was conducted. For the clearance gap region, a fully gridded special H-grid was chosen. Comparisons were made between the flow characteristic at design speed, representative for a transonic flow regime, and at 65% speed, representative for a subsonic flow regime. The computations were used to analyse the flow phenomena through the tip clearance region for the different configurations and their impact on the performance of the compressor stage.  相似文献   

14.
IntroductionFundamental stUdies of losses in tUrbomachinery in-dicate that, besides giving rise to losses of work, leakageflows contribute to the overall creation of entropy andkinetic encrgy losses. Some entropy is created in thelabyrinth seals and in passages between the fixed androtating pats of turbomachinery. CFD computations inlabyrinth seal geometries enable the evaluation of theentropy ereation PrOCesses there. CFD-based analysis canm1nindze the mass fiow rates of the tip leakage a…  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号