共查询到20条相似文献,搜索用时 31 毫秒
1.
2.
基于灰色马尔柯夫预测的测量仪器校准间隔动态优化 总被引:2,自引:0,他引:2
根据测量仪器校准参数数据特点,建立了仪器校准参数动态发展趋势的时间序列组合模型。将灰色预测与马尔柯夫预测方法优化互补,用灰色预测模型预测参数总体发展趋势,在此基础上采用马尔柯夫模型预测参数在总体趋势下的随机波动性变化,得到校准参数发展趋势预测模型的解。给出基于校准参数趋势预测的校准间隔动态优化方法,并通过实验数据对预测模型进行了验证。结果表明,此模型既能预测校准参数总体趋势,又适合于波动性较大的随机序列变化;校准间隔的优化改善了计量管理中不足计量和过剩计量的缺陷。 相似文献
3.
4.
Solid laboratory calibration of a nonimaging spectroradiometer 总被引:1,自引:0,他引:1
Field-based nonimaging spectroradiometers are often used in vicarious calibration experiments for airborne or spaceborne imaging spectrometers. The calibration uncertainties associated with these ground measurements contribute substantially to the overall modeling error in radiance- or reflectance-based vicarious calibration experiments. Because of limitations in the radiometric stability of compact field spectroradiometers, vicarious calibration experiments are based primarily on reflectance measurements rather than on radiance measurements. To characterize the overall uncertainty of radiance-based approaches and assess the sources of uncertainty, we carried out a full laboratory calibration. This laboratory calibration of a nonimaging spectroradiometer is based on a measurement plan targeted at achieving a =10% uncertainty calibration. The individual calibration steps include characterization of the signal-to-noise ratio, the noise equivalent signal, the dark current, the wavelength calibration, the spectral sampling interval, the nonlinearity, directional and positional effects, the spectral scattering, the field of view, the polarization, the size-of-source effects, and the temperature dependence of a particular instrument. The traceability of the radiance calibration is established to a secondary National Institute of Standards and Technology calibration standard by use of a 95% confidence interval and results in an uncertainty of less than ?7.1% for all spectroradiometer bands. 相似文献
5.
校准规范是实施校准的基础。编写专用测试设备校准规范是一项非常重要的工作,它是计量保证的基本要求。本文论述了编写组的组成、编写工作程序、校准项目及校准方法、测量标准设备的选择以及校准时间间隔。 相似文献
6.
7.
8.
9.
We report on a calibration procedure that enhances the precision of an interferometer based frequency stabilization by several orders of magnitude. For this purpose, the frequency deviations of the stabilization are measured precisely by means of a frequency comb. This allows us to implement several calibration steps that compensate different systematic errors. The resulting frequency deviation is shown to be less than 5.7?MHz (rms 1.6?MHz) in the whole wavelength interval 750-795?nm. Wide tuning of a stabilized laser at this exceptional precision is demonstrated. 相似文献
10.
《IEEE sensors journal》2006,6(4):974-981
Calibration is the process of identifying and correcting the most likely error in sensor measurements. The basis for the authors' calibration procedure is to construct a statistical error model that captures the characteristics of the measurement errors. Such an error model can be constructed either offline or online and is derived using the nonparametric kernel-density-estimation techniques. Models constructed using various forms of the kernel smoothing functions are compared using statistical evaluation methods. Based on the selected error model, they propose four alternatives to make the transition from the error model to the calibration model, which is represented by piecewise polynomials. In addition, statistical validation and evaluation methods such as resubstitution, is used in order to establish the interval of confidence for both the error model and the calibration model. Traces of the acoustic signal-based distance measurements recorded by infield deployed sensors are used as their demonstrative example. Finally, they discuss the broad range of applications of the error models and provide an example on how adopting statistical error model as the optimization objective impacts the accuracy of the location discovery problem in wireless sensor networks. 相似文献
11.
Bobbio A. Tavella P. Montefusco A. Costamagna S. 《IEEE transactions on instrumentation and measurement》1997,46(4):747-751
The paper discusses a class of stochastic models for evaluating the optimal calibration interval in measuring instruments. The model is based on the assumption that the calibration status of a measuring instrument can be monitored by means of one observable parameter. The observable parameter is undergoing a stochastic drift process. The paper introduces and compares stochastic drift models of different nature, and estimates the first passage time of the monitored parameter on a preset limit. The calibration interval is determined as a suitable percentile of the distribution function of the first passage time. A preliminary validation of the model, based on a sample of experimental data collected on a class of instruments, is finally reported 相似文献
12.
Carullo A. Corbellini S. Grassini S. 《IEEE transactions on instrumentation and measurement》2007,56(4):1212-1218
The increasing diffusion of pollutant measuring units, which are installed over wide areas, along with the short calibration interval of several sensors for pollutant quantities, requires new calibration infrastructures to be developed. This paper describes an attempt to develop an innovative calibration system which is based on traveling standards and which does not require units to be removed from the measuring site during the calibration process. The calibration system is based on a traveling standard, which is composed of one or more cylinders that contain gas mixtures, a cell with standard sensors, and a control unit with networking capabilities, which allows the traveling standard to be remotely exercised. A prototype of the proposed system is described and the preliminary results reported. 相似文献
13.
Evaluation of Errors in Calibration Procedures for Measurements of Reflection Coefficient 总被引:1,自引:0,他引:1
《IEEE transactions on instrumentation and measurement》1978,27(4):354-358
Procedures for the calibration of computer-controlled network analyzers in reflection measurements are studied. The major aim of this paper is to develop an error analysis in order to define a quality factor, for evaluating the performances of a calibration procedure. This is done by using the invariance property of the cross ratio, which easily lets one obtain analytical expressions for the residual errors As an application of this technique, a comparison between two actual calibration procedures has been made using an automatic network analyzer. The experimental results favorably compare with the ones obtained on theoretical basis. 相似文献
14.
Estimating the endpoint of a distribution function is of interest in product analysis and predicting the maximum lifetime
of an item. In this paper, we propose an empirical likelihood method to construct a confidence interval for the endpoint.
A simulation study shows the proposed confidence interval has better coverage accuracy than the normal approximation method,
and bootstrap calibration improves the accuracy. 相似文献
15.
主要介绍了利用新研制的通用仪器综合校准系统 ,在实现频率计类仪器“时间间隔”参数自动校准时 ,对相关仪器连接、校准方法以及软件设计等问题 ,提出了一种间接测量单线时间间隔的方法。 相似文献
16.
17.
18.
Application of an ANFIS Algorithm to Sensor Data Processing 总被引:1,自引:0,他引:1
Depari A. Flammini A. Marioli D. Taroni A. 《IEEE transactions on instrumentation and measurement》2007,56(1):75-79
Some sensors require frequent recalibrations; therefore, calibration cost must be limited. In this paper, a new calibration technique is presented. It is a two-phase method which is based on adaptive neuro-fuzzy networks, and it shows superior performances with respect to traditional algorithms, requiring fewer calibration points and less computational power in the recalibration phase. Feasibility has been demonstrated with a pyroelectric biaxial positioning system, reaching performance to the limit of the adopted test bench, on the order of 20 mum with respect to a whole sensible area of 7 mm times 7 mm 相似文献
19.
20.
为了减小现场环境与校准环境的差异对真空漏孔校准的影响,通过理论研究,设计了现场真空漏孔校准装置,可实现对真空漏孔的现场校准。考虑到现场真空漏孔校准装置需便于携带及搬运,装置的设计采用了分体式结构。现场真空漏孔校准装置由抽气系统、校准室系统、真空漏孔连接系统、流量输出系统、充气系统、定容室与压力测量系统及烘烤系统等7个部分组成,复合了定容法及固定流导法两种校准方法,预计真空漏孔校准范围为5×10-10~5×10-5 Pa?m3/s,合成标准不确定度为10%。 相似文献