首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 218 毫秒
1.
Anterior corneal and internal component contributions to overall peripheral aberrations of five human eyes were determined, based on corneal topography and overall aberration measurements. Anterior corneal position and orientation (tilt) were referenced to the line of sight. Ray tracing was performed through the anterior cornea for 6-mm-diameter pupils at angles out to 40 degrees in both the temporal and the nasal visual fields. In general, both component and overall Zernike aberrations were greater for the nasal than for the temporal visual field. In general, the anterior corneal aberration components were considerably higher than the overall aberrations across the visual field and were balanced to a considerable degree by the internal ocular aberration components. The component and overall levels of Zernike third-order aberrations showed linear trends away from the fixation axis, and the component levels of Zernike fourth-order aberrations showed quadratic trends away from the fixation axis. The second-order, but not higher-order, aberration components were susceptible to the choice of image radius of curvature, while disregarding corneal position and orientation affected second- and higher-order aberration components.  相似文献   

2.
A Shack-Hartmann aberrometer was used to measure the monochromatic aberration structure along the primary line of sight of 200 cyclopleged, normal, healthy eyes from 100 individuals. Sphero-cylindrical refractive errors were corrected with ophthalmic spectacle lenses based on the results of a subjective refraction performed immediately prior to experimentation. Zernike expansions of the experimental wave-front aberration functions were used to determine aberration coefficients for a series of pupil diameters. The residual Zernike coefficients for defocus were not zero but varied systematically with pupil diameter and with the Zernike coefficient for spherical aberration in a way that maximizes visual acuity. We infer from these results that subjective best focus occurs when the area of the central, aberration-free region of the pupil is maximized. We found that the population averages of Zernike coefficients were nearly zero for all of the higher-order modes except spherical aberration. This result indicates that a hypothetical average eye representing the central tendency of the population is nearly free of aberrations, suggesting the possible influence of an emmetropization process or evolutionary pressure. However, for any individual eye the aberration coefficients were rarely zero for any Zernike mode. To first approximation, wave-front error fell exponentially with Zernike order and increased linearly with pupil area. On average, the total wave-front variance produced by higher-order aberrations was less than the wave-front variance of residual defocus and astigmatism. For example, the average amount of higher-order aberrations present for a 7.5-mm pupil was equivalent to the wave-front error produced by less than 1/4 diopter (D) of defocus. The largest pupil for which an eye may be considered diffraction-limited was 1.22 mm on average. Correlation of aberrations from the left and right eyes indicated the presence of significant bilateral symmetry. No evidence was found of a universal anatomical feature responsible for third-order optical aberrations. Using the Marechal criterion, we conclude that correction of the 12 largest principal components, or 14 largest Zernike modes, would be required to achieve diffraction-limited performance on average for a 6-mm pupil. Different methods of computing population averages provided upper and lower limits to the mean optical transfer function and mean point-spread function for our population of eyes.  相似文献   

3.
Monochromatic aberrations of human eyes in the horizontal visual field   总被引:1,自引:0,他引:1  
We measured the monochromatic aberrations of five subjects' right eyes both temporally and nasally out to 40 degrees from fixation. We used a Hartmann-Shack sensor with modifications to equipment and software to enable off-axis measurements. Results were standardized for 6-mm pupils. There was considerable variation among subjects in the pattern of aberrations. Aberrations were generally greater in the nasal visual field than in the temporal visual field; in the case of third-order aberrations, this was true for all subjects. The contribution of third-order Zernike aberrations to the root-mean-square aberration increased up to four times from the center to the edge of the field, but the contribution of fourth- to sixth-order Zernike aberrations varied little across the visual field. Results were similar to those of a previous investigation using laser ray tracing and were of the order of those predicted by Navarro's finite schematic eye.  相似文献   

4.
5.
We calculated the impact of higher-order aberrations on retinal image quality and the magnitude of the visual benefit expected from their correction in a large population of human eyes. Wave aberrations for both eyes of 109 normal subjects and 4 keratoconic patients were measured for 3-, 4-, and 5.7-mm pupils with a Shack-Hartmann sensor. Retinal image quality was estimated by means of the modulation transfer function (MTF) in white light. The visual benefit was calculated as the ratio of the MTF when the monochromatic higher-order aberrations are corrected to the MTF corresponding to the best correction of defocus and astigmatism. On average, the impact of the higher-order aberrations for a 5.7-mm pupil in normal eyes is similar to an equivalent defocus of approximately 0.3 D. The average visual benefit for normal eyes at 16 c/deg is approximately 2.5 for a 5.7-mm pupil and is negligible for small pupils (1.25 for a 3-mm pupil). The benefit varies greatly among eyes, with some normal eyes showing almost no benefit and others a benefit higher than 4 at 16 c/deg across a 5.7-mm pupil. The benefit for keratoconic eyes is much larger. The benefit at 16 c/deg is 12 and 3 for 5.7- and 3-mm pupils, respectively, averaged across four keratoconics. These theoretical benefits could be realized in normal viewing conditions but only under specific conditions.  相似文献   

6.
We calculated the impact of higher-order aberrations on retinal image quality and the magnitude of the visual benefit expected from their correction in a large population of human eyes. Wave aberrations for both eyes of 109 normal subjects and 4 keratoconic patients were measured for 3-, 4-, and 5.7-mm pupils with a Shack-Hartmann sensor. Retinal image quality was estimated by means of the modulation transfer function (MTF) in white light. The visual benefit was calculated as the ratio of the MTF when the monochromatic higher-order aberrations are corrected to the MTF corresponding to the best correction of defocus and astigmatism. On average, the impact of the higher-order aberrations for a 5.7-mm pupil in normal eyes is similar to an equivalent defocus of approximately 0.3 D. The average visual benefit for normal eyes at 16 c/deg is approximately 2.5 for a 5.7-mm pupil and is negligible for small pupils (1.25 for a 3-mm pupil). The benefit varies greatly among eyes, with some normal eyes showing almost no benefit and others a benefit higher than 4 at 16 c/deg across a 5.7-mm pupil. The benefit for keratoconic eyes is much larger. The benefit at 16 c/deg is 12 and 3 for 5.7- and 3-mm pupils, respectively, averaged across four keratoconics. These theoretical benefits could be realized in normal viewing conditions but only under specific conditions.  相似文献   

7.
Doble N  Miller DT  Yoon G  Williams DR 《Applied optics》2007,46(20):4501-4514
Numerous types of wavefront correctors have been employed in adaptive optics (AO) systems for correcting the ocular wavefront aberration. While all have improved image quality, none have yielded diffraction-limited imaging for large pupils (>/=6 mm), where the aberrations are most severe and the benefit of AO the greatest. To this end, we modeled the performance of discrete actuator, segmented piston-only, and segmented piston/tip/tilt wavefront correctors in conjunction with wavefront aberrations measured on normal human eyes in two large populations. The wavefront error was found to be as large as 53 microm, depending heavily on the pupil diameter (2-7.5 mm) and the particular refractive state. The required actuator number for diffraction-limited imaging was determined for three pupil sizes (4.5, 6, and 7.5 mm), three second-order aberration states, and four imaging wavelengths (0.4, 0.6, 0.8, and 1.0 microm). The number across the pupil varied from only a few actuators in the discrete case to greater than 100 for the piston-only corrector. The results presented will help guide the development of wavefront correctors for the next generation of ophthalmic instrumentation.  相似文献   

8.
We report root-mean-square (RMS) wavefront error (WFE) for individual aberrations and cumulative high-order (HO) RMS WFE for the normal human eye as a function of age by decade and pupil diameter in 1 mm steps from 3 to 7 mm and determine the relationship among HO RMS WFE, mean age for each decade of life, and luminance for physiologic pupil diameters. Subjects included 146 healthy individuals from 20 to 80 years of age. Ocular aberration was measured on the preferred eye of each subject (for a total of 146 eyes through dilated pupils; computed for 3, 4, 5, 6, and 7 mm pupils; and described with a tenth-radial-order normalized Zernike expansion. We found that HO RMS WFE increases faster with increasing pupil diameter for any given age and pupil diameter than it does with increasing age alone. A planar function accounts for 99% of the variance in the 3-D space defined by mean log HO RMS WFE, mean age for each decade of life, and pupil diameter. When physiologic pupil diameters are used to estimate HO RMS WFE as a function of luminance and age, at low luminance (9 cd/m2) HO RMS WFE decreases with increasing age. This normative data set details (1) the 3-D relationship between HO RMS WFE and age for fixed pupil diameters and (2) the 3-D relationship among HO RMS WFE, age, and luminance for physiologic pupil diameters.  相似文献   

9.
We have used the Hartmann-Shack technique previously to measure ocular aberrations along the horizontal meridian of the visual field. This requires considerable modifications from the technique for measuring the aberrations corresponding to the fovea. We now further develop the technique so that it can be used for any meridian of the visual field. Allowance is made for any auxiliary optics placed in front of the eye to compensate for the limited range of the Hartmann-Shack technique and for the case where aberrations are estimated at a wavelength other than the measuring wavelength. Zernike wave aberrations are converted to peripheral refractions. Examples are presented showing the developments, and we discuss change in wave aberrations when converting from a circular to an elliptical pupil.  相似文献   

10.
高级像差对人眼成像质量和视觉的影响   总被引:3,自引:0,他引:3  
定量地研究高级像差对人眼成像质量和视觉的影响对人眼像差矫正具有重要的实验和临床意义.利用Hartmann-Shack波前传感器人眼像差仪测量了正常人眼6mm瞳孔的波前像差,由波前像差计算出人眼光学系统的光学调制传递函数MTF和Strehl比率,并由MTF和视网膜空间像调制度AIM曲线计算出人眼视锐度和对比敏感度函数CSF.根据MTF和Strehl比率分析了高级像差对人眼成像质量的影响,根据视锐度和对比敏感度函数CSF分析了高级波像差对视觉的影响.研究表明Zernik前6级像差对人眼成像质量和视觉的影响是不可忽略的,更高级的像差对人眼成像质量和视觉的影响较小,甚至可以忽略.对Zemik前6级像差进行矫正,可以得到相当好的视觉.  相似文献   

11.
A procedure to calculate the wave aberration of the human cornea from its surface shape measured by videokeratography is presented. The wave aberration was calculated as the difference in optical path between the marginal rays and the chief ray refracted at the surface, for both on- and off-axis objects. The corneal shape elevation map was obtained from videokeratography and fitted to a Zernike polynomial expansion through a Gram-Schmidt orthogonalization. The wave aberration was obtained also as a Zernike polynomial representation. The accuracy of the procedure was analyzed. For calibrated reference surface elevations, a root-mean-square error (RMSE) of 1 to 2 microm for an aperture 4-6 mm in diameter was obtained, and the RMSE associated with the experimental errors and with the fitting method was 0.2 microm. The procedure permits estimation of the corneal wave aberration from videokeratoscopic data with an accuracy of 0.05-0.2 microm for a pupil 4-6 mm in diameter, rendering the method adequate for many applications.  相似文献   

12.
Orthonormal polynomials in wavefront analysis: error analysis   总被引:2,自引:0,他引:2  
Dai GM  Mahajan VN 《Applied optics》2008,47(19):3433-3445
Zernike circle polynomials are in widespread use for wavefront analysis because of their orthogonality over a circular pupil and their representation of balanced classical aberrations. However, they are not appropriate for noncircular pupils, such as annular, hexagonal, elliptical, rectangular, and square pupils, due to their lack of orthogonality over such pupils. We emphasize the use of orthonormal polynomials for such pupils, but we show how to obtain the Zernike coefficients correctly. We illustrate that the wavefront fitting with a set of orthonormal polynomials is identical to the fitting with a corresponding set of Zernike polynomials. This is a consequence of the fact that each orthonormal polynomial is a linear combination of the Zernike polynomials. However, since the Zernike polynomials do not represent balanced aberrations for a noncircular pupil, the Zernike coefficients lack the physical significance that the orthonormal coefficients provide. We also analyze the error that arises if Zernike polynomials are used for noncircular pupils by treating them as circular pupils and illustrate it with numerical examples.  相似文献   

13.
The interocular symmetry of the high-order corneal wavefront aberration (WA) in a population of myopic eyes was analyzed before and after photorefractive keratectomy (PRK). The preoperative and one-year postoperative corneal aberration data (from third to seventh Zernike orders) for 4- and 7-mm pupils from right and left eyes were averaged after correcting for the effects of enantiomorphism to test for mirror symmetry. Also, the mean corneal point-spread function (PSF) for right and left eyes was calculated. Preoperatively, a moderate and high degree of correlation in the high-order corneal WA between eyes was found for 4- and 7-mm pupils, respectively. Myopic PRK did not significantly change the interocular symmetry of corneal high-order aberrations. No discernible differences in the orientation PSF between eyes were observed one year after surgery in comparison with the preoperative state over the two analyzed pupils.  相似文献   

14.
Orthonormal polynomials in wavefront analysis: analytical solution   总被引:1,自引:0,他引:1  
Zernike circle polynomials are in widespread use for wavefront analysis because of their orthogonality over a circular pupil and their representation of balanced classical aberrations. In recent papers, we derived closed-form polynomials that are orthonormal over a hexagonal pupil, such as the hexagonal segments of a large mirror. We extend our work to elliptical, rectangular, and square pupils. Using the circle polynomials as the basis functions for their orthogonalization over such pupils, we derive closed-form polynomials that are orthonormal over them. These polynomials are unique in that they are not only orthogonal across such pupils, but also represent balanced classical aberrations, just as the Zernike circle polynomials are unique in these respects for circular pupils. The polynomials are given in terms of the circle polynomials as well as in polar and Cartesian coordinates. Relationships between the orthonormal coefficients and the corresponding Zernike coefficients for a given pupil are also obtained. The orthonormal polynomials for a one-dimensional slit pupil are obtained as a limiting case of a rectangular pupil.  相似文献   

15.
廖志远  邢廷文  刘志祥 《光电工程》2011,38(11):146-150
泽尼克圆多项式在圆形光瞳的正交性和能够代表经典像差而被广泛应用到波前分析中,用泽尼克圆多项式作为矩形光瞳基底函数,通过推导得到在矩形光瞳上正交的多项式.这个在矩形光瞳上正交的多项式不仅是唯一的,而且也能够表示经典像差,就像泽尼克圆多项式在表示圆形光瞳时具有这样的特性一样.矩形光瞳上正交多项式像泽尼克圆多项式一样即可以用...  相似文献   

16.
Zernike polynomials and their associated coefficients are commonly used to quantify the wavefront aberrations of the eye. When the aberrations of different eyes, pupil sizes, or corrections are compared or averaged, it is important that the Zernike coefficients have been calculated for the correct size, position, orientation, and shape of the pupil. We present the first complete theory to transform Zernike coefficients analytically with regard to concentric scaling, translation of pupil center, and rotation. The transformations are described both for circular and elliptical pupils. The algorithm has been implemented in MATLAB, for which the code is given in an appendix.  相似文献   

17.
Using theoretical estimates of the optical-transfer function and line-spread function as image-quality criteria, we predicted the influence of the Stiles-Crawford effect (SCE) on both optical performance of the eye and subjective measurements of transverse aberrations when pupils are decentered. The SCE was modeled as a pupil apodization. The SCE appears to improve image quality by providing compensation for aberrations induced by pupil decentration, but this improvement is usually small. When a criterion of the placement of the image is used as the centroid of the line-spread function, an average SCE reduces the influence of pupil decentration on subjective transverse chromatic aberrations (TCA's) for 5-mm-diameter pupils by 30%. This reduction is much less than that obtained by previous experimental studies of TCA, and possible reasons for this discrepancy are discussed. Decentering the SCE produces an appreciable shift in subjective TCA for 5-mm-diameter pupils of 1.4 arc min per 1-mm decentration (at wavelengths 433 and 622 nm).  相似文献   

18.
Zernike annular polynomials and atmospheric turbulence   总被引:1,自引:0,他引:1  
Imaging through atmospheric turbulence by systems with annular pupils is discussed using the Zernike annular polynomials. Fourier transforms of these polynomials are derived analytically to facilitate the calculation of variance and covariance of the aberration coefficients. Zernike annular shape functions are derived and used to calculate the Strehl ratio and the residual phase structure and mutual coherence functions when a certain number of modes are corrected using, say, a deformable mirror. Special cases of long- and short-exposure images are also considered. The results for systems with a circular pupil are obtained as a special case of the annular pupil.  相似文献   

19.
The Stiles-Crawford effect (SCE) of the first kind has often been considered to be important to spatial visual performance in that it ameliorates the influence of defocus and aberrations. We investigated the influence of SCE apodization on visual acuity as a function of defocus (out to +/-2 D) in four subjects. We used optical filters, conjugate with the eye's entrance pupil, that neutralized or doubled the existing SCE. With an illiterate-E task, the influence of the SCE was more noticeable for myopic defocus than for hypermetropic defocus, was generally more noticeable for high-contrast than for low-contrast letters, and increased with increase in pupil size. The greatest influence on visual acuity of neutralizing the SCE, across the subjects and range of conditions, was deterioration of 0.06 (4-mm pupil), 0.16 (6-mm pupil), and 0.29 log unit (7.6-mm pupil).  相似文献   

20.
Mahajan VN 《Applied optics》2012,51(18):4087-4091
In a recent paper, we considered the classical aberrations of an anamorphic optical imaging system with a rectangular pupil, representing the terms of a power series expansion of its aberration function. These aberrations are inherently separable in the Cartesian coordinates (x,y) of a point on the pupil. Accordingly, there is x-defocus and x-coma, y-defocus and y-coma, and so on. We showed that the aberration polynomials orthonormal over the pupil and representing balanced aberrations for such a system are represented by the products of two Legendre polynomials, one for each of the two Cartesian coordinates of the pupil point; for example, L(l)(x)L(m)(y), where l and m are positive integers (including zero) and L(l)(x), for example, represents an orthonormal Legendre polynomial of degree l in x. The compound two-dimensional (2D) Legendre polynomials, like the classical aberrations, are thus also inherently separable in the Cartesian coordinates of the pupil point. Moreover, for every orthonormal polynomial L(l)(x)L(m)(y), there is a corresponding orthonormal polynomial L(l)(y)L(m)(x) obtained by interchanging x and y. These polynomials are different from the corresponding orthogonal polynomials for a system with rotational symmetry but a rectangular pupil. In this paper, we show that the orthonormal aberration polynomials for an anamorphic system with a circular pupil, obtained by the Gram-Schmidt orthogonalization of the 2D Legendre polynomials, are not separable in the two coordinates. Moreover, for a given polynomial in x and y, there is no corresponding polynomial obtained by interchanging x and y. For example, there are polynomials representing x-defocus, balanced x-coma, and balanced x-spherical aberration, but no corresponding y-aberration polynomials. The missing y-aberration terms are contained in other polynomials. We emphasize that the Zernike circle polynomials, although orthogonal over a circular pupil, are not suitable for an anamorphic system as they do not represent balanced aberrations for such a system.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号