首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
Structural health monitoring system has been implemented on high‐rise buildings to provide real‐time measurement of structural responses for evaluating their serviceability, safety, and sustainability. However, because of the complex structural configuration of a high‐rise building and the limited number of sensors installed in the building, the complete evaluation of structural performance of the building in terms of the information directly recorded by a structural health monitoring system is almost impossible. This is particularly true when seismic‐induced ground motion is unknown. This paper thus proposes an integrated method that enables the optimal placement of multi‐type sensors on a high‐rise building on one hand and the reconstruction of structural responses and excitations using the information from the optimally located sensors on the other hand. The structural responses measured from multi‐type sensors are fused to estimate the full state of the building in the modal coordinates using Kalman filters, from which the structural responses at unmeasured locations and the seismic‐induced ground motion can be reconstructed. The optimal multi‐type sensor placement is simultaneously achieved by minimizing the overall estimation errors of structural responses at the locations of interest to a desired target level. A numerical study using a simplified finite element model of a high‐rise building is performed to illustrate the effectiveness and accuracy of the proposed method. The numerical results show that by using 3 types of sensors (inclinometers, Global Positioning System, and accelerometers), the proposed method offers an effective way to design a multi‐type sensor system, and the multi‐type sensors at their optimal locations can produce sufficient information on the response and excitation reconstruction.  相似文献   

2.
High‐hardness viscoelastic rubber dampers are used to upgrade both the habitability environment and the structural safety in high‐rise buildings subjected to wind disturbances. While most of usual viscoelastic dampers have limitation on temperature and frequency dependencies, etc., the proposed high‐hardness viscoelastic rubber dampers possess many unprecedented properties. High hardness, large stiffness, small temperature and frequency dependencies are examples of such properties. Mechanical modelling of the proposed high‐hardness viscoelastic rubber dampers is introduced first, and the wind‐induced response of high‐rise buildings with and without the proposed high‐hardness viscoelastic rubber dampers is computed under dynamic horizontal loads derived from wind tunnel tests. It is shown that high‐rise buildings with the proposed high‐hardness viscoelastic rubber dampers exhibit extremely smaller wind‐induced responses (both along‐wind and cross‐wind responses) than those without such dampers. In particular, a remarkable reduction of acceleration has been achieved owing to sufficient hysteresis even in the small strain range. It is concluded that the proposed high‐hardness viscoelastic rubber dampers can upgrade the habitability environment of building structures dramatically. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

3.
In super high‐rise buildings with varying story heights, the wind‐induced inter‐story drifts might violate the specified limit. However, these effects have seldom been concerned in wind‐induced response analysis. The theory and application of equivalent static wind load (ESWL) for wind‐induced inter‐story drifts of super high‐rise buildings were studied in this paper. A spectral decomposition method suitable for multi‐point excitation problems was firstly proposed. The formula of ESWL targeting for largest inter‐story drift was derived. For more reasonable structural design, the ESWL for multiple targets including displacement atop of building and inter‐story drifts at all story levels is put forward, in which the dominant modal inertial forces are adopted as the based load vectors. The presented methods were finally verified by its application for the wind‐induced response analysis for a tallest super tall building in Guangzhou. The researched results showed that the proposed spectral decomposition method not only has the same precision as the complete quadratic combination method but also possesses higher computation efficiency. The ESWL for multiple targets produces the same static responses for all the specified wind‐induced response, so it is much more rational for wind‐resistant structural design. Meanwhile, it is more reasonable to select the wind‐induced responses in the same direction simultaneously as the targeted values for obtaining the required ESWLs; however, the ESWL targeting for the wind‐induced responses in all degrees of freedom would generate more queer and unrealistic ESWLs distribution. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

4.
An analysis and estimation method of multibalance synchronous test is established to study the wind effect of a complex super high‐rise building with weak connection. First, the frequency domain method is applied to deduce the calculation process of the wind effect of the multitower structure on the basis of the high frequency force balance (HFFB) technique. Then, the synchronous force test of HFFB is conducted on a twin‐tower super high‐rise building connected by a bridge. The wind‐induced response and loads and the interference effect between the two towers are analyzed based on the wind tunnel test data. The displacement correlation between the towers and the relative displacement of the multitower structure are investigated. Results show that the maximum and minimum relative displacements in the along‐bridge direction are 0.26 m in the along‐wind direction and ?0.26 m in the crosswind direction, respectively. The channeling effect formed by the surrounding buildings is the main cause of the maximum cross‐bridge displacement. The influence of the correlation between the two towers can be ignored for the along‐bridge relative displacement. The results of the HFFB and high‐frequency pressure integral test agree with each other, thereby indicating the reliability and effectiveness of the proposed method.  相似文献   

5.
Ping An Finance Center with a height of 600 m and 118 storeys, located in Shenzhen, is currently the second tallest building in China. This paper presents a comprehensive study of wind effects on the supertall building through wind tunnel testing and field measurement. The wind‐induced loads and pressures on the skyscraper were measured by high‐frequency force balance technique and synchronous multipressure sensing system, respectively. In the wind tunnel study, a whole range of characteristic properties, including mean and r.m.s force coefficients, power spectral densities, coherences, correlations, and phase‐plane trajectories, wind‐induced displacement, and acceleration responses were presented and discussed. In addition, a field measurement study of the dynamic responses of Ping An Finance Center was conducted during a tropical cyclone, which aimed to verify the design assumptions and further the understanding of the dynamic properties and performance of the 600‐m‐high supertall building, including natural frequencies, damping ratios, and wind‐induced structural responses. Then, the serviceability of the skyscraper is assessed on the basis of the experimental results and field measurements. The outcomes of this combined model test and field measurement study are expected to be useful for the wind‐resistant design of future supertall buildings.  相似文献   

6.
This study presents a convolutional neural network (CNN)‐based response estimation model for structural health monitoring (SHM) of tall buildings subject to wind loads. In this model, the wind‐induced responses are estimated by CNN trained with previously measured sensor signals; this enables the SHM system to operate stably even when a sensor fault or data loss occurs. In the presented model, top‐level wind‐induced displacement in the time and frequency domains, and wind data in the frequency domain are configured into the input map of the CNN to reflect the resisting capacity of a tall building, the change in the dynamic characteristics of the building due to wind loads, and the relationship between wind load and the building. To evaluate stress, which is used as a safety indicator for structural members in the building, the maximum and minimum strains of columns are set as the output layer of the CNN. The CNN is trained using measured wind and wind response data to predict the column strains during a future wind load. The presented model is validated using data from a wind tunnel test of a building model. The performance of the presented model is verified through strain estimation with data that were not used in the CNN training. To assess the validity of the presented input map configuration, the estimation performance is compared with a CNN that considered only the time domain responses as input. Furthermore, the effects of the variations in the configuration of the CNN on the wind response estimation performance are examined.  相似文献   

7.
High‐frequency force balance test is a major technical means to evaluate the wind effect of super high‐rise buildings. Most super high‐rise buildings have the characteristic that the first two‐order modal frequencies are close, and thus, considerable modal coupling effects (MCEs) may occur under wind load. For a balance model system (BMS), MCEs increase the difficulty of correcting aerodynamic distortion signals. For the wind‐induced vibration analysis of a structural system (PSS), the calculation results of the wind‐induced response and the equivalent static wind load (ESWL) may be significantly affected without considering MCE. Based on the above‐mentioned signal distortion of BMS and the modal coupling problem of PSS, this study proposes a wind‐induced vibration calculation method for the two coupled systems (BMS and PSS). The method uses the second‐order blind identification technique based on complex modal theory and the Bayesian spectral density method considering full aerodynamic characteristics to achieve effective correction of the distortion signal in BMS. In addition, it deduces the calculation method of the wind‐induced response and ESWL considering the three‐dimensional coupled vibration of a super high‐rise building. The wind effect calculation results of a 528‐m super high‐rise building confirm the necessity and effectiveness of the proposed method.  相似文献   

8.
Steel‐framed modular buildings afford certain advantages, such as rapid and high‐quality construction. However, although steel‐framed modules have been adopted in several countries, most of them are limited to low‐to‐medium‐rise structures; modular high‐rise buildings are rare. This study proposes a feasible structural design solution for high‐rise buildings using a steel‐framed modular system. A 31‐story student hostel building in Hong Kong is redesigned as a steel‐framed modular building and used as a case study. The finite element models of the building are formulated, and the structural behaviors under wind and earthquake load scenarios are compared. Moreover, the structural design process used for the 31‐story building is applied to design a hypothetical 40‐story modular building to further examine the proposed design solution. The numerical analysis results indicate that the roof lateral displacements and interstory drift ratios of the redesigned modular building are within the allowable limits of design codes; moreover, the modular connections behave elastically under the most adverse loading scenarios. Accordingly, the proposed solution can be used to design steel‐framed modular buildings of up to 40 stories, while complying with relevant wind and seismic codes.  相似文献   

9.
The synchronous multipoint scanning system technique in wind tunnel tests and random vibration theory method were used to analyze the wind‐induced torsion vibration of some irregularly shaped super high‐rise buildings in downtowns. The torsion vibration modes and the spectra of torsion wind load were studied, and the proportions of mean wind torsion, inertia torsion and the mass eccentricity torsion caused by horizontal inertia forces are discussed. The following conclusions can be drawn. First, the third and fourth modes have torsion vibration shapes, and their frequencies are in the high‐energy area of the spectra of the torsion wind load; the third and fourth modes are included in the resonant component of the spectra of the top torsion angle of the building, and the third mode is dominant. Second, the torsion stiffness is weak in the high stories of the building, so the inertia torsion is dominant, whereas the torsion stiffness is strong in the low stories; the mean wind torsion is dominant. The proportion of the mass eccentricity torsion moment caused by horizontal inertia forces is small. Finally, the wind‐induced torsion moment at a 90° wind angle is the largest, whereas the torsion eccentricity is 46% of the radius of gyration and is much greater than the mass eccentricity; thus, the wind‐induced torsion should be considered. The wind‐induced torsion vibration of the building is sensitive to wind directions. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

10.
This paper describes some results obtained from full‐scale measurements of wind effects on a super‐tall building, Di‐Wang Tower, located in Shenzhen, China. This tall building has 79‐storeys with a height of approximately 324 m. Field measurements including wind speed, wind direction and wind‐induced acceleration responses have been made. The amplitude‐dependent characteristics of damping are obtained by using the random decrement technique from the detailed analysis of the field acceleration measurements. The main objective of this paper is to present detailed investigations into the effects of nonlinear damping on the dynamic responses of the tall building subjected to various types of applied loads based on the measured amplitude‐dependent damping characteristics. The predicted dynamic responses of the building obtained by using the measured damping characteristics were compared with those computed by using constant damping parameters assumed by the structural designers. It is concluded from the investigations that knowledge of actual damping characteristics are very important in the accurate prediction of the dynamic responses of a tall building when the major harmonic components of the applied loads overlap with the lowest natural frequencies of the building. The design damping level for tall building structures currently used by structural engineering practitioners appears to be high and not conservative. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

11.
This article presents a Kalman‐filter‐based estimation algorithm for identification of wind loads on a super‐tall building using limited structural responses. In practice, acceleration responses are most convenient to be measured among wind‐induced dynamic responses of structures. The proposed inverse method allows estimating the unknown wind loads and structural responses of a super‐tall building using limited acceleration measurements. Taipei 101 Tower is a super‐tall building with 101 stories and a height of 508 m. Field measurements and numerical simulations of the wind effects on Taipei 101 Tower are conducted. The wind loads acting on the super‐tall building are estimated based on the wind‐induced responses determined from the numerical simulations and the refined finite‐element model of the structure, which are in good agreement with the exact results. The stability performance of the proposed algorithm is evaluated. The influence of noise levels in the measurements and covariance matrix of noise on the identification accuracy are investigated and discussed based on the L‐curve method. Finally, the wind loads and structural responses are reconstructed based on the field‐measured accelerations during Typhoon Matsa. The accuracy of the identified results is verified by comparing the reconstructed acceleration responses with the field measurements. The results of this study show that the proposed inverse approach can provide accurate predictions of the wind loads and wind‐induced responses of super‐tall buildings based on limited measured responses.  相似文献   

12.
An equivalent discrete model is developed for time domain dynamic analysis of uniform high‐rise shear wall‐frame buildings with fixed base and carrying any number of tuned mass dampers (TMDs). The equivalent model consists of a flexural cantilever beam and a shear cantilever beam connected in parallel by a finite number of axially rigid members that allow the consideration of intermediate modes of lateral deformation. The proposed model was validated by a building whose lateral resisting system consists of a combination of shear walls and braced frames. The results showed the effectiveness of TMDs to reduce the peak displacements, interstory drift ratio, and accelerations when the building is subjected to a seismic load. The root mean square accelerations due to along‐wind loads also decrease if TMDs are attached to the building.  相似文献   

13.
Tuned mass dampers (TMDs) are employed to control the wind‐induced responses of tall buildings. In the meantime, TMD may have an impact on the correlation of wind‐induced responses and combination coefficients of equivalent static wind loads (ESWLs). First, the mass matrix and stiffness matrix were extracted in this paper in accordance with the structural analysis model of two high‐rise buildings, and on that basis, the wind‐induced vibration responses analysis model with and without TMD was established. Second, the synchronous multipoint wind tunnel test to measure the pressure was performed for two high‐rise buildings, and the time history of wind‐induced vibration responses with and without TMD was studied. Finally, the impact of TMD on the correlation of wind‐induced responses and combination coefficients of ESWLs was discussed. The results of two examples suggest that after the installation of TMD, the increase of ρxy was 2.1% to 35.0% and ρyz was 2.8% to 45.6% at all wind directions for Building 1, and the increase of ρxy was 3.9% to 17.1% and ρyz was 6.8% to 38.3% for Building 2. The combination coefficients of ESWLs of two buildings were 3% to 6% larger than that of the original structure. The conclusion of this paper can be referenced by the wind resistant design of high‐rise buildings with TMD.  相似文献   

14.
When a large super high‐rise building taller than the surrounding tall buildings is built in a dense urban area, the aerodynamic interference effects of the surrounding buildings on the proposed building attract much attention, while the interference effects of the taller high‐rise building on the nearby existing buildings are often ignored. Based on a series of wind tunnel tests, the interference effects of a proposed taller high‐rise building, an adjacent equal‐height partner building, and relatively short background buildings on the target building's local wind pressures are analysed in this paper. Two‐dimensional numerical simulation are carried out to further understand the interference mechanism in some cases. The test results show that the influence of a nearby proposed taller high‐rise building may lead to wind‐induced damage on the interfered shorter buildings' envelopes. The envelope structures of other surrounding buildings facing the side of the proposed building need to be given more attention.  相似文献   

15.
Across‐wind aerodynamic damping ratios are determined from the wind‐induced acceleration responses of 10 aeroelastic models of square super high‐rise buildings in an urban flow condition (exposure category C in the Chinese code) using the random decrement technique. Moreover, the influences of amplitude‐dependent structural damping ratio on the estimation of aerodynamic damping ratio are discussed. The validity of estimated damping is examined through a comparison with previous research achievements. On the basis of the estimated results, the characteristics of the across‐wind aerodynamic damping ratios of modified square high‐rise buildings are studied. The effects of aerodynamically modified cross‐sections, such as chamfered, slotted and tapered cross‐section, on the across‐wind aerodynamic damping ratio are investigated. The results indicate that modifications of cross‐sections are not always effective in suppressing the aeroelastic effects of super high‐rise buildings. Low corner‐cut ratios (chamfer ratios from 5% to 20% and slot ratios from 5% to 10%) and low taper ratio (1%) significantly decrease the magnitudes of absolute aerodynamic damping ratios. However, large modifications of cross‐sections (slot ratio of 20% and taper ratios from 3% to 5%) increase wind‐induced responses by changing the aerodynamic damping ratios. According to the database, empirical aerodynamic damping function parameters are fitted for high‐rise buildings with aerodynamically modified square cross‐sections. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

16.
Herein, by a case study on a 5‐MW wind turbine system developed by Nanjing University of Aeronautics and Astronautics, the wind field simulation and wind‐induced vibration characteristics of wind turbine tower‐blade coupled systems is analyzed. First, the blade‐nacelle‐tower‐basis integrated finite element model with centrifugal forces induced by rotational blades is established. Then, based on a harmony superposition method and the modified blade element‐momentum theory, the fluctuating wind field of tower‐blade coupled systems is simulated, which considers wind shear effect, tower shadow effect, rotational effect, blade‐tower dynamic and model interaction effects. Finally, the wind‐induced dynamic responses and wind vibration coefficients of the wind turbine tower‐blade coupled structure are discussed through the ‘consistent coupled method’ previously proposed by us. The results indicate that the wind‐induced responses of a large wind turbine tower‐blade coupled structure present complicated modal responses and multimode coupling effect. Additionally, the rotational effect would amplify aerodynamic loads on blades with high frequency, wind‐induced dynamic responses and wind vibration coefficients of wind turbine tower. The centrifugal force effect could also amplify natural vibration frequency of the tower‐blade coupled system and reduce the wind‐induced dynamic responses and wind vibration coefficients of wind turbine tower. The research could contribute to wind‐resistant design of structure for a large‐scale wind turbine tower‐blade system. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

17.
This paper presents an integrated procedure for wind‐induced response analysis and design optimization for rectangular steel tall buildings based on the random vibration theory and automatic least cost design optimization technique using Micro‐Genetic Algorithm (GA). The developed approach can predict wind‐induced drift and acceleration responses for serviceability design of a tall building; the technique can also provide an optimal resizing design of the building under wind loads to achieve cost‐efficient design. The empirical formulas of wind force spectra obtained from simultaneous measurements of surface pressures on various rectangular tall building models in wind tunnel tests are verified testified using a published example. Upon the known wind force spectra, the equivalent static wind loads for every storey, such as along‐wind, across‐wind and torsional loads, are then determined and applied for structural analysis including estimation of wind‐induced responses. An improved form of GAs, a Micro‐GA, is adopted to minimize the structural cost/weight of steel buildings subject to top acceleration and lateral drifts constraints with respect to the discrete design variables of steel section sizes. The application and effectiveness of the developed integrated wind‐induced response analysis and design optimization procedure is illustrated through a 30‐storey rectangular steel building example. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

18.
19.
This paper describes the results obtained from the full‐scale measurements of wind effects on a 70‐storey tall building in Hong Kong. The objective of the experiment is to measure wind action on and wind‐induced response of the tall building. Simultaneous and continuous data of wind speeds, wind directions and acceleration responses have been recorded at the top of the tall building since 1995. The field data presented in this paper were measured during the passage of four typhoons—Typhoon Kent (1995), Typhoon Ryan (1995), Typhoon Sibyl (1995) and Typhoon Sally (1996). The characteristics of the typhoon wind and the structural responses of the building are investigated. The serviceability of this tall building under typhoon conditions is discussed on the basis of the field measurements. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

20.
For investigation of the wind load characteristics on high‐rise buildings with opening, a series of rigid rectangular high‐rise building models with opening were tested by synchronous multi‐pressure sensing system (SMPSS) in a boundary wind tunnel. Influence parameters including different opening heights, opening rates, opening patterns, and terrain categories are studied in detail. Based on the test results, the local wind force coefficients, base moment coefficients, and power spectral densities were discussed. The results indicated that the opening could affect the wind loads acting on high‐rise buildings to different extent. The distinct reduction of wind loads on high‐rise buildings was found at along‐wind direction, which could be evaluated by a proposed simplified expression accordingly. This study aims to provide useful information for the wind‐resistant design of high‐rise buildings with opening.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号