首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
针对土壤耦合热泵地下U型换热埋管,建立了管内流体以及换热器周围土壤热渗耦合物理数学模型。所建模型考虑了U型管的实际形状,土壤考虑为饱和多孔介质,管内湍流流动采用R ea lizab le k-ε模型。采用F luen t软件对模型进行模拟计算,得到了管内流体以及周围土壤温度分布。分析了土壤中水的渗流对传热过程的影响,并对考虑渗流作用时不同土壤物性对单根U型垂直埋管换热器周围土壤温度场进行了模拟计算与分析。  相似文献   

2.
Being environmental friendly and with the potential of energy-efficiency, ground-source heat pump (GSHP) systems are widely used. However, in southern China, there exists large difference between cooling load in summer and heating load in winter. Thus the increase of soil temperature gradually year-by-year will decrease the COP of the GSHP system. In this paper, the configuration of a vertical dual-function geothermal heat exchanger (GHE) used in an integrated soil cold storage and ground-source heat pump (ISCS&GSHP) system, which charged cold energy to the soil at night and produced chilled water at daytime in summer, and supplied hot water for heating in winter, is presented. This is then followed by reporting the development of the mathematical model for the GHE considering the impact of the coupled heat conduction and groundwater advection on the heat transfer between the GHE and its surrounding soil. The GHE model developed was then integrated with a water-source heat pump and a building energy simulation program together for a whole ISCS&GSHP system. Then the operation performance of the ISCS&GSHP system used for a demonstration building is studied. These simulation results indicated the system transferred 71.505% of the original power consumption at daytime to that at nighttime for the demonstration building. And the net energy exchange in the soil after one-year operation was only 2.28% of the total cold energy charged. Thus we can see the feasibility of the ISCS&GSHP system technically.  相似文献   

3.
In the design of a ground-source heat pump (GSHP) system, the heat transfer from the fluid to the ground is influenced by the thermal borehole resistance between the fluid and the borehole surface and also by the interference resistance between the two (or four) pipes inside the borehole. Several authors have proposed empirical and theoretical relations to evaluate these resistances as well as methods to evaluate them experimentally. The paper compares the different approaches and proposes good practice to evaluate the resistances. The impact of the different approaches on the design of heat exchanger is also examined. Two-dimensional and fully three-dimensional numerical simulations are used to evaluate the different methods. A new method is also proposed to evaluate the borehole resistances from in situ tests.  相似文献   

4.
Taking the fluid temperature distribution along the borehole depth into account, a new quasi-three-dimensional model for vertical ground heat exchangers has been established, which provides a better understanding of the heat transfer processes in the geothermal heat exchangers. On this basis the efficiency of the borehole has been defined and its analytical expression derived. Comparison with the previous two-dimensional model shows that the quasi-three-dimensional model is more rational and more accurate to depict the practical feature of the conduction of geothermal heat exchanger, and the efficiency notion can be easily used to determine the inlet and outlet temperature of the circulating fluid inside the heat exchanger.  相似文献   

5.
A transient heat transfer model has been development for a thermal response test (TRT) on a vertical borehole with a U-tube. Vertical borehole heat exchangers are frequently coupled to ground source heat pumps, which heat and cool buildings. The model provides an analytical solution for the vertical temperature profiles of the circulating fluid through the U-tube, and the temperature distribution in the ground. The model is verified with data sets from a laboratory sandbox and field TRTs, as well as a previously reported numerical solution. Unlike previous analytical models, the vertical profiles for the circulating fluid are generated by the model without any assumption of their functional form.  相似文献   

6.
This paper presents the development and application of a three-dimensional (3D) numerical simulation model for U-tube borehole heat exchangers (BHEs). The proposed model includes the thermal capacities of the borehole components, viz., the fluid inside the tubes, as well as the grouting material, making it possible to consider the transient effects of heat and mass transports inside the borehole. In this approach, the use of simplified thermal resistance and capacity models (TRCMs) provides accurate results while substantially reducing the number of nodes and the computation time compared with fully discretized computations such as finite element (FE) models. The model is compared with a fully discretized FE model which serves as a reference. Furthermore, the model is used to evaluate thermal response test (TRT) data by the parameter estimation technique. Comparison of the model results with the results of an analytical model based on the line-source theory further establishes the advantage of the developed 3D transient model, as the test duration can be shortened and results are more accurate.  相似文献   

7.
Buildings represent nearly 40 percent of total energy use in the U.S. and about 50 percent of this energy is used for heating, ventilating, and cooling the space. Conventional heating and cooling systems are having a great impact on security of energy supply and greenhouse gas emissions. Unlike conventional approach, this paper investigates an innovative passive air conditioning system coupling earth-to-air heat exchangers (EAHEs) with solar collector enhanced solar chimneys. By simultaneously utilizing geothermal and solar energy, the system can achieve great energy savings within the building sector and reduce the peak electrical demand in the summer. Experiments were conducted in a test facility in summer to evaluate the performance of such a system. During the test period, the solar chimney drove up to 0.28 m3/s (1000 m3/h) outdoor air into the space. The EAHE provided a maximum 3308 W total cooling capacity during the day time. As a 100 percent outdoor air system, the coupled system maximum cooling capacity was 2582 W that almost covered the building design cooling load. The cooling capacities reached their peak during the day time when the solar radiation intensity was strong. The results show that the coupled system can maintain the indoor thermal environmental comfort conditions at a favorable range that complies with ASHRAE standard for thermal comfort. The findings in this research provide the foundation for design and application of the coupled system.  相似文献   

8.
9.
文中对垂直U型埋管土壤源地热换热器的传热性能进行了分析,并优化设计计算了不同负荷下地热换热器的长度.首先根据土壤源地热换热器的传热性能分析,在满足工程实践的基础上,选择了IGSHPA模型简化下的传热分析方法计算传热热阻;然后利用一维导热和线热源模型,得到流体至管道内壁的对流换热热阻,塑料管壁的导热热阻,钻孔内部的导热热...  相似文献   

10.
对空气横掠片距不相等的叉排椭圆翅片管散热器的传热及阻力性能进行了试验研究,得到试件在一系列工况下的传热与管外流动阻力数据,并对试验数据进行分析计算,从总传热系数K中分离出管外空气侧的对流换热系数h,给出有工程应用价值的管外换热准则关系式及管外阻力准则关系式。认为椭圆管管外的平均换热效果优于圆管。在相同的流通截面积下椭圆管传热周边较长,换热面积相应增加,因此结构上允许布置得更紧凑。  相似文献   

11.
利用低气压环境模拟装置对开缝翅片管换热器在不同气压下的换热性能进行实验研究.研究结果表明:随着气压不断降低,换热器周围空气密度逐渐降低,换热器空气侧换热系数以及显热换热量逐渐降低,而空气含湿量随着气压降低逐渐升高,导致潜热换热量逐渐增加;当气压降至0.058 MPa以下时,换热器空气侧潜热换热量占主要部分,当气压为0.04 MPa时,换热器换热能力与常压下相比下降了36.63%.  相似文献   

12.
An analytical solution of the transient temperature response in a semi‐infinite medium with a line source of finite length has been derived, which is a more appropriate model for boreholes in geothermal heat exchangers, especially for their long‐duration operation. The steady‐state temperature distribution has also been obtained as a limit of this solution. An erratic approach to this problem that appears in some handbooks and textbooks is indicated. Two representative steady‐state borehole wall temperatures, the middle point temperature and the integral mean temperature, are defined. Differences between them are compared, and concise expressions for both are presented for engineering applications. On this basis the influence of the annual imbalance between heating and cooling loads of the geothermal heat exchangers is discussed regarding their long‐term performance. © 2002 Wiley Periodicals, Inc. Heat Trans Asian Res, 31(7): 558–567, 2002; Published online in Wiley InterScience ( www.interscience.wiley.com ). DOI 10.1002/htj.10057  相似文献   

13.
Available analytical models for the thermal analysis of ground source heat pumps (GSHPs) either neglect groundwater flow or axial effects. In the present study a new analytical approach which considers both effects is developed. Comparison with existing analytical solutions based on the finite and infinite line source theory is carried out. This study shows that in general the heat transfer at the borehole heat exchanger (BHE) is affected by groundwater flow and axial effects. The latter is even more important for long simulation times and short borehole lengths. At the borehole wall the influence of the axial effect is restricted to Peclet numbers lower than 10, assuming the BHE length as characteristic length. Moreover, the influence of groundwater flow is negligible for Peclet numbers lower than 1.2. As a result for Peclet numbers between 1.2 and 10 the combined effect of groundwater flow and axial effects has to be accounted for when evaluating the temperature response of a BHE at the borehole wall and thus the use of the moving finite line source model is required.  相似文献   

14.
竖直双U型埋管地热换热器支管间热短路分析   总被引:1,自引:0,他引:1  
采用地热换热器准三维传热模型和数值计算的方法,对竖直双U型埋管地热换热器支管间的热短路进行了分析,讨论了管间距和回灌材料的导热系数对热短路的影响,并提出了减少热短路的措施。  相似文献   

15.
Christopher J. Wood  Hao Liu  Saffa B. Riffat   《Energy》2010,35(12):4932-4940
Novel methods are sought to provide greater efficiency of the installation of ground heat exchangers for GSHPs (ground source heat pumps) in domestic buildings. An economically viable option is to utilise concrete foundation piles as ground heat exchangers. The objective of this study is to investigate the operation of utilising a piled foundation structure as a ground heat exchanger. A test plot of 72 m2 (ground floor area) was produced with 21 × 10 m deep concrete piles, with a single U tube pipe in each. Ground heat was extracted by a heat pump with the heat loading being varied in line with the date and the average air temperature. Over the 2007/2008 heating season this study had investigated the temperature changes in the foundation piles and the surrounding ground in addition to the heat pump operational performance. The temperature changes observed in the region of the test plot were compared with variations naturally experienced in the ground due to the seasonal climatic influence. The SPF (seasonal performance factor) of the heat pump was 3.62 and the ground temperature at a distance of 5 m from the test plot was seen to be undisturbed by the heat extraction and followed the predicted seasonal variation.  相似文献   

16.
The ground can be used as an energy source, an energy sink, or for energy storage and for this reason ground characteristics should be available. Therefore the purpose of this paper is to present the recorded ground temperatures at eight representative sites of Cyprus, in relation to depth, time of year, geology and altitude and discuss the efficiency of Ground Coupled Heat Pumps. The ground temperature was recorded for a period of one year, from October 2009 to October 2010. According to the results obtained, in several locations in Cyprus the surface zone reaches a depth of 0.5 m. The shallow zone penetrates to 7-8 m and there after the deep zone follows in which the temperature remains constant throughout the year with a range between 18 and 23 °C. For the eight boreholes, additional geothermal data were also recorded like the type of ground and thermal conductivities of the various geologic layers. The data collected clearly indicate that there is a potential for the efficient use of Ground Coupled Heat Pumps (GCHPs) in Cyprus leading to significant savings in heating and cooling energy consumption.  相似文献   

17.
氟塑料换热器以其耐腐蚀、耐磨损等优点而备受关注,但氟塑料热导率较低,换热能力差,限制了其广泛应用。石墨烯-PFA复合材料兼具石墨烯优异的导热性和可熔性聚四氟乙烯(PFA)良好的耐酸碱腐蚀性,是新一代的换热器材料。搭建了余热回收测试实验台,对石墨烯-PFA复合材料换热器和金属换热器的传热性能进行对比。研究了不同烟气流速、不同进口烟气温度以及不同石墨烯配比对复合材料传热性能的影响。结果表明:对于金属换热器和复合材料换热器,当烟气流速从2.0增加到4.0 m/s时,传热系数分别增加到原来的1.19和1.34倍;随着进口烟温的升高,两种材质的传热系数分别降低了15.6%和14.7%;随着石墨烯含量增加,复合材料的导热系数以及传热系数均增加。  相似文献   

18.
螺旋套管换热器传热特性研究   总被引:2,自引:0,他引:2  
根据螺旋套管换热器的结构特点及传热特性,建立了水一水蒸气的流动与传热的三维几何模型.利用Fluem时不同工况下的螺旋套管进行了数值模拟,得出了湍流状态下螺旋套管内流体的温度场、速度场和压力场;利用搭建的螺旋套管换热器试验台,得出多种工况下的传热系数,为螺旋套管换热器的设计计算提供了依据.同时将试验结果和数值模拟结果进行...  相似文献   

19.
This paper describes the influence of heat flow from high‐temperature refrigerant to low‐temperature refrigerant through fins by thermal conduction. To estimate that influence, we applied a thermal network method that can consider refrigerant quality distribution in the heat exchanger. At the same time, for verifying the estimation, an experiment was performed with a two‐row, two‐pass heat exchanger. Prediction shows that the heat transfer capacity of a condenser is reduced by 3% for a simple two‐row, two‐pass heat exchanger by heat conduction in fins. Comparison of experimental results and predicted results proves that the prediction error was within 1% for condenser capacity. © 2008 Wiley Periodicals, Inc. Heat Trans Asian Res, 37(2): 101–114, 2008; Published online in Wiley InterScience ( www.interscience.wiley.com ). DOI 10.1002/htj.20184  相似文献   

20.
Experiments were carried out to study the heat transfer characteristics of a single-row aluminum fin-and-tube crossflow heat exchanger with an emphasis in the regime of low flow rate of the in-tube fluid. The Chilton-Colburn analogy, in conjunction with the least-squares power-law technique, was used to correlate experimental data. Both air- and water-side heat transfer correlations were developed in the form of the Nusselt numbers as a function of Reynolds and Prandtl numbers. The experimental observations are quantitatively compared to the predictions of correlations available in the published literature. Different transfer mechanisms were found to be operative in the ranges of water-side Reynolds numbers based on the hydraulic diameter. In a range of Reynolds number from 1,200 to 6,000, the water-side thermal resistance accounts for less than ten percent of the overall thermal resistance. The dominant thermal resistance is always on the air-side. On the other hand, the thermal resistance of water-side is nearly equal to that of air-side in a Reynolds number range from 500 to 1,200.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏