首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A thermal model is developed for heating and cooling of an agricultural greenhouse integrated with an aquifer coupled cavity flow heat exchanger system (ACCFHES). The ACCFHES works on the principal of utilizing deep aquifer water available at the ground surface through an irrigation tube well already installed in every agricultural field at constant year-round temperature of 24 °C. The analysis is based on the energy balance equations for different components of the greenhouse. Using the derived analytical expressions, a computer program is developed in C++ for computing the hourly greenhouse plant and room air temperature for various design and climatic parameters. Experimental validation of the developed model is carried out using the measured plant and room air temperature data of the greenhouse (in which capsicum is grown) for the winter and summer conditions of the year 2004–2005 at Chandigarh (31°N and 78°E), Punjab, India. It is observed that the predicted and measured values are in close agreement. Greenhouse room air and plant temperature is maintained 6–7 K and 5–6 K below ambient, respectively for an extreme summer day and 7–8 K and 5–6 K above ambient, respectively for an extreme winter night. Finally, parametric studies are conducted to observe the effect of various operating parameters such as mass of the plant, area of the plant, mass flow rate of the circulating air and area of the ACCFHES on the greenhouse room air and plant temperature.  相似文献   

2.
The sensitivity of electricity consumption to air temperature and air humidity are effective indicators in evaluating the impacts of countermeasures against urban heat islands. The impacts of these countermeasures vary in time and space and so sensitivities based on finer resolution data are needed. Using actual hourly electric power consumption data from the business districts of Tokyo, we calculated the sensitivity of electric power consumption using multiple regression analysis. The sensitivities appear from 07:00 to 23:00 local standard time (LST) during weekdays during both winter and summer, mainly from 09:00 to 17:00 LST. The sensitivities to air temperature during winter are approximately 0.7–1.1 (W/floor-m2)/°C on an average and those during summer are approximately 1.1–1.4 on an average; the sensitivities to air humidity are approximately 0.6–0.9 on an average. It was found that the sensitivities to air temperature are caused due to heating during winter and cooling during summer; further, the sensitivities to air humidity were caused by dehumidification not for conditioning the air humidity of the room but for the condensation around the air-conditioner's coils with cooling during summer.  相似文献   

3.
The main objective of the present study is to investigate the performance characteristics of an underground air tunnel (UAT) for greenhouse heating with a 47 m horizontal, 56 cm nominal diameter U-bend buried galvanized ground heat exchanger. This system was installed in the Solar Energy Institute, Ege University, Izmir, Turkey. Based upon the measurements made in the heating mode, the average heat extraction rate to the soil is found to be 3.77 kW, or 80.21 W/m of tunnel length, while the required tunnel length in meters per kW of heating capacity is obtained as 12.46. The entering air temperature to the tunnel ranges from 14.3 to 21.5 °C, with an average value of 15.5 °C. When the system operates, the greenhouse air is at a minimum day temperature of 13.1 °C with a relative humidity of 32%. The maximum heating coefficient of performance of the UAT system is about 6.42, while its minimum value is about 0.98 at the end of a cloudy and cold day and fluctuates between these values at other times. The daily average maximum COP values for the system are also obtained to be 6.42. The total average COP in the heating season is found to be 5.16.  相似文献   

4.
An experimental solar energy facility was designed to meet as much of the heating demand in a typical Spanish dwelling as possible. With a view to using the facility during the summer and preventing overheating-induced deterioration of the solar collectors in that season of the year, an absorption chiller was fitted to the system to produce solar-powered air conditioning. The facility operated in solar space heating mode in the winter of 2008–2009 and in cooling mode during the summer of 2008. The design was based on a new type of flat plate vacuum solar collectors that delivered higher efficiency than conventional panels. This type of collectors can reach temperatures of up to 110 °C in the summer and up to 70 °C on the coldest winter days. The solar facility comprised a 48-m2 (with a net area of 42 m2) solar collector field, a 25-kW plate heat exchanger, a 1500-l storage tank, a 4.5-kW (Rotartica) air-cooled absorption chiller and several fan coils. The facility was tested by using it to heat and cool an 80-m2 laboratory located in Madrid. As the average area of Spanish homes is 80 m2, the findings were generally applicable to national housing. The solar facility was observed to be able to meet 65.3% of the space heating demand. For air conditioning, the system covered 46% of the demand, but with high indoor temperatures. In other words, the collector field was found to be able to air condition only half of the home (40 m2). Lastly, the savings in CO2 emissions afforded by the use of this facility compared to conventional air conditioning were calculated, along with its amortisation period. These results have been extrapolated calculating the potential energy savings and emissions reduction for all the Spanish households.  相似文献   

5.
One of the first rehabilitated passive energy standard office buildings in Europe was extensively monitored over two years to analyse the cooling performance of a ground heat exchanger and mechanical night ventilation together with the summer comfort in the building. To increase the storage mass in the light weight top floor, phase change materials (PCM) were used in the ceiling and wall construction. The earth heat exchanger installed at a low depth of 1.2 m has an excellent electrical cooling coefficient of performance of 18, but with an average cooling power of about 1.5 kW does not contribute significantly to cooling load removal. Mechanical night ventilation with 2 air changes also delivered cold at a good coefficient of performance of 6 with 14 kW maximum power. However, the night air exchange was too low to completely discharge the ceilings, so that the PCM material was not effective in a warm period of several days. In the ground floor offices the heat removal through the floor to ground of 2–3 W m−2 K−1 was in the same order of magnitude than the charging heat flux of the ceilings. The number of hours above 26 °C was about 10% of all office hours. The energy performance of the building is excellent with a total primary energy consumption for heating and electricity of 107–115 kW h m−2 a−1, without computing equipment only 40–45 kW h m−2 a−1.  相似文献   

6.
An air-to-earth heat exchanger (ATEHE) consists of pipes buried in soil. We have evaluated the technical and economic performance of an ATEHE coupled to the system for heating or cooling of a building that uses 100% fresh air as heating or cooling medium during winter and summer. The soil is divided into elementary layers. The problem solved, is non stationary; however, steady state-energy equations are used for soil layers in each time step. It is found that the use of the ATEHE covers a portion of the daily building needs for space heating or cooling. The cost of the ATEHE energy is lower for summer than for winter.  相似文献   

7.
Solar or solar-assisted space heating systems are becoming more and more popular. The solar energy utilization efficiency is high when the collector is coupled with indoor radiant heating suppliers, since in principle, lower supply temperature means lower demand temperature and then the system heat loss is less. A new type radiant end system is put forward for even lower supply temperature compared to the conventional radiant floor heating systems. A three dimensional model was established to investigate its energy supply capacities. Simulation results show that 50 W per meter length tube can be achieved with the medium temperature of 30 °C for heating and 15 °C for cooling. The predicted results agree well with the actual data from a demonstration building. Furthermore, it is demonstrated that a supply temperature of 22 °C in winter and of 17 °C in summer already met the indoor requirements. The new end system has good prospects for effective use of local renewable resources.  相似文献   

8.
The long-term system simulation and economic analysis of solar-assisted cooling/heating system (SACH-2) was carried out in order to find an economical design. The solar heat driven ejector cooling system (ECS) is used to provide part of the cooling load to reduce the energy consumption of the air conditioner installed as the base-load cooler. A standard SACH-2 system for cooling load 3.5 kW (1 RT) and daily cooling time 10 h is used for case study. The cooling performance is assumed only in summer seasons from May to October. In winter season from November to April, only heat is supplied. Two installation locations (Taipei and Tainan) were examined.It was found from the cooling performance simulation that in order to save 50% energy of the air conditioner, the required solar collector area is 40 m2 in Taipei and 31 m2 in Tainan, for COPj = 0.2. If the solar collector area is designed as 20 m2, the solar ejector cooling system will supply about 17–26% cooling load in Taipei in summer season and about 21–27% cooling load in Tainan. Simulation for long-term performance including cooling in summer (May–October) and hot water supply in winter (November–April) was carried out to determine the monthly-average energy savings. The corresponding daily hot water supply (with 40 °C temperature rise of water) for 20 m2 solar collector area is 616–858 L/day in Tainan and 304–533 L/day in Taipei.The economic analysis shows that the payback time of SACH-2 decreases with increasing cooling capacity. The payback time is 4.8 years in Tainan and 6.2 years in Taipei when the cooling capacity >10 RT. If the ECS is treated as an additional device used as a protective equipment to avoid overheating of solar collectors and to convert the excess solar heat in summer into cooling to reduce the energy consumption of air conditioner, the payback time is less than 3 years for cooling capacity larger than 3 RT.  相似文献   

9.
A heating, ventilation and air-conditioning (HVAC) system with integrated aquifer thermal energy storage (ATES) was designed for a supermarket building in Mersin, a city near the Mediterranean coast in Turkey (36° 49′ N and 34° 36′ E). This is the first ATES application carried out in Turkey. The peak cooling and heating loads of the building are 195 and 74 kW, respectively. The general objective of the system is to use the groundwater from the aquifer to cool down the condenser of the HVAC system and at the same time storing this waste heat in the aquifer. Cooling with groundwater at around 18 °C instead of utilizing outside summer air at 30–35 °C decreases consumption of electrical energy significantly. In addition, stored heat can be recovered when it is needed in winter. The HVAC system with ATES started operation in August 2001 in cooling mode with an average coefficient of performance (COP) of 4.18, which is almost 60% higher than a conventional system.  相似文献   

10.
V.P. Sethi 《Solar Energy》2009,83(1):21-38
In this study, five most commonly used single span shapes of greenhouses viz. even-span, uneven-span, vinery, modified arch and quonset type have been selected for comparison. The length, width and height (at the center) are kept same for all the selected shapes. A mathematical model for computing transmitted total solar radiation (beam, diffused and ground reflected) at each hour, for each month and at any latitude for the selected geometry greenhouses (through each wall, inclined surfaces and roofs) is developed for both east-west and north-south orientation. Computed transmitted solar radiation is then introduced in a transient thermal model developed to compute hourly inside air temperature for each shape and orientation. Experimental validation of both the models is carried out for the measured total solar radiation and inside air temperature for an east-west orientation, even-span greenhouse (for a typical day in summer) at Ludhiana (31°N and 77°E) Punjab, India. During the experimentation, capsicum crop is grown inside the greenhouse. The predicted and measured values are in close agreement. Results show that uneven-span shape greenhouse receives the maximum and quonset shape receives the minimum solar radiation during each month of the year at all latitudes. East-west orientation is the best suited for year round greenhouse applications at all latitudes as this orientation receives greater total radiation in winter and less in summer except near the equator. Results also show that inside air temperature rise depends upon the shape of the greenhouse and this variation from uneven-span shape to quonset shape is 4.6 °C (maximum) and 3.5 °C (daily average) at 31°N latitude.  相似文献   

11.
In the present paper a quasi‐steady state mathematical model is developed to predict the outlet air temperature and monthly heating and cooling potentials of an earth–air heat exchanger. Monthly values of heating and cooling potentials are estimated by rigorous experimentation throughout the year for composite climate of New Delhi. The uncertainty values are calculated for each month; for December the value is 4.9%. It is observed that there is an 8.9 and a 5.9°C temperature rise and fall during winter and summer due to the earth–air heat exchanger buried at a depth of 1.5 m underground. The correlation coefficient, root mean square of percentage deviation, reduced chi‐square and mean bias error have been computed for each month. The values are 1, 3.0%, 0.8 and ?0.63 for December. Statistical analysis shows that there is fair agreement between theoretical results and experimental observations for each month. Monthly values of heating and cooling potentials have also been predicted for other climatic conditions in India namely Jodhpur, Chennai, Mumbai and Kolkata. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

12.
Currently the use of conventional screen net houses for off-season vegetable raising in north India composite climate is not so effective and has many constructional and operational limitations like poor structural design, higher constructional cost, no greenhouse effect in winter and higher plant temperatures in summer. Similarly, the use of polyethylene sheet covered greenhouses also has problems like much higher constructional and operational costs and higher inside air temperatures in summers. In this study, modified designs of 500 m2 (one kanal) and 250 m2 (half kanal) screen net house have been presented particularly suitable for composite climate (where both winters as well as summers are harsh) as a replacement for conventional net house and polyethylene sheet covered greenhouse design. To make these designs low cost and more effective, low tunnels (covered with low density polyethylene sheet) have been designed and used in winter over the plant rows to generate localized greenhouse effect for faster plant growth. By doing so, average daily air temperature under the tunnels was raised about 9–10 °C above the open field air temperature. In this way, huge cost of covering the net house or greenhouse during winter with costly polyethylene sheet could be saved. Similarly, in extreme summer when the ambient air temperature exceeded 40 °C (during the fruiting stage of the crop) a 50% shade net was used inside the modified net house at 2.5 m height (instead of using active cooling system) resulting in 4–6 °C drop in the plant temperature. Experimental evaluation of the modified net house was conducted during winter and summer months of year 2007–08 (December to June) by growing brinjal crop and compared with conventional net house, polyethylene sheet greenhouse and in open field condition. It was observed that due to the combined effect of low tunnels (in winter) and shade net (in summer), the micro-climatic parameters like air temperature, plant temperature, solar radiation and light intensity remained within desirable range during different stages of crop growth resulting in 37.6% and 11.5% increase in the yield of brinjal crop as compared to conventional net house and PE covered greenhouse yield, respectively, at 31°N latitude. Economic analysis of the modified net house was also conducted and compared with the conventional net house and PE covered greenhouse of the same area. It was observed that 500 m2 area modified net house (coupled with low tunnels and shade net) produces highest yield and has the highest net present worth (Rs 3,35,324) and the lowest payback period (5.2 years) as compared to the conventional net house (Rs 2,04,712 and 6.5 years) and PE covered greenhouse (Rs 1,52,614 and 10.5 years). On the other hand for 250 m2 modified net house, the net present worth and payback period was Rs 1,20,417 and 9.7 years as compared to Rs 65,497 and 11.5 years and Rs 10,616 and 17 years for conventional net house and PE covered greenhouse.  相似文献   

13.
赵定国 《上海节能》2020,(3):203-207
一种只在裸屋顶上铺放5cm厚种植基质的"轻型屋顶绿化技术",具有明显的夏降温、冬保温作用。内外表面温度绿化屋顶与裸屋顶相比作用明显:全年波动幅度小;一日间温度波动平缓,变化幅度极小;夏季不受高温影响,冬季不受低温影响的"夏降温、冬保温"效果明显;内外表面日均温度"夏低冬高",内表面春、夏、秋三季低6%~10%左右,冬季高20%以上;屋顶绿化可以减少房间空调用电量18%,室外温度越高,屋顶绿化的节电效果越大。  相似文献   

14.
V.P. Sethi  Sadhna Arora 《Solar Energy》2009,83(9):1472-1484
A conventional greenhouse solar dryer of 6 m2 × 4 m2 floor area (east-west orientation) was improved for faster drying using inclined north wall reflection (INWR) under natural as well as forced convection mode. To increase the solar radiation availability onto the product (to be dried) during extreme summer months, a temporary inclined wall covered with aluminized reflector sheet (of 50 μm thickness and reflectance 0.93) was raised inside the greenhouse just in front of the vertical transparent north wall. By doing so, product fully received the reflected beam radiation (which otherwise leaves through the north wall) in addition to the direct total solar radiation available on the horizontal surface during different hours of drying. The increment in total solar radiation input enhanced the drying rate of the product by increasing the inside air and crop temperature of the dryer. Inclination angle of the reflective north wall with vertical (β) was optimized for various selective widths of the tray W (1.5, 2, 2.5 and 3 m) and for different realistic heights of existing vertical north wall (h) at 25°N, 30°N and 35°N latitudes (hot climatic zones). Experimental performance of the improved dryer was tested during the month of May 2008 at Ludhiana (30.56°N) climatic conditions, India by drying bitter gourd (Momordica charantia Linn) slices. Results showed that by using INWR under natural convection mode of drying, greenhouse air and crop temperature increased by 1-6.7 °C and 1-4 °C, respectively, during different drying hours as compared to, when INWR was not used and saved 13.13% of the total drying time. By using INWR under forced convection mode of drying, greenhouse air and crop temperature increased by 1-4.5 °C and 1-3 °C, respectively, during different drying hours as compared to, when INWR was not used and saved 16.67% of the total drying time.  相似文献   

15.
A thermal model has been developed to investigate the potential of using the stored thermal energy of the ground for greenhouse heating with the help of an earth to air heat exchanger (EAHE) system integrated with the greenhouse located in the premises of IIT, Delhi, India. Experiments were conducted extensively during the winter period from November 2002 to March 2003, but the model developed was validated against the clear and sunny days. Parametric studies performed for EAHE coupled with the greenhouse illustrate the effects of buried pipe length, pipe diameter, mass flow rate of air, depth of ground and soil types on greenhouse air temperatures. Temperatures of greenhouse air with the experimental parameters of EAHE were found to be on an average 7–8°C more in the winter than the same greenhouse without EAHE. Greenhouse air temperatures increase in the winter with increasing pipe length, decreasing pipe diameter, decreasing mass flow rate of flowing air inside buried pipe and increasing depth of ground up to 4 m. Predicted and measured values of greenhouse air temperature, which were verified in terms of root mean square of percent deviation and correlation coefficient, exhibited fair agreement. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

16.
在冬冷夏热且夏季冷负荷远大于冬季热负荷的地区常采用带有冷却塔的复合式地源热泵系统,其控制策略存在极大的优化空间。文章提出了直接比较冷却塔和与土壤换热器相连的板式换热器的出口温度的控制方法,并通过人工神经网络预测板式换热器机组侧的出口水温来实现此控制方法。通过FLUENT软件建立复合式地源热泵系统动态数值模型,获取建立神经网络的数据,采用3层BP网络,建立了多个预测板式换热器机组侧出口温度的模型。研究结果表明,采用神经网络可以准确实现此预测,绝对误差不超过0.4℃。  相似文献   

17.
Using a micro X-ray beam, the structure of a water swollen Nafion® membrane, alone or in a membrane electrode assembly (MEA) designed for fuel cells, was studied upon cooling down to −70 °C. By scanning the membranes along their thicknesses, the water sorption–desorption process was investigated as a function of cooling/heating stages. From the scattering curves, it was deduced that the state of the water at a sub-zero temperature is glassy inside the membrane and ice crystals are observed only outside it. In the case of the MEA, this growth can be destructive since this formation is localised inside the active layers.  相似文献   

18.
This research target was to improve the thermal efficiency of a solar water heating system (SWHS) coupled with a built-in solar water pump. The designed system consists of 1.58-m2 flat plate solar collectors, an overhead tank placed at the top level, the larger water storage tank without a heat exchanger at the lower level, and a one-way valve for water circulation control. The discharge heads of 1 and 2 m were tested. The pump could operate at the collector temperature of about 70–90 °C and vapor gage pressure of 10–18 kPa. It was found that water circulation within the SWHS ranged between 15 and 65 l/d depending upon solar intensity and discharge head. Moreover, the max water temperature in the storage tank is around 59 °C. The max daily pump efficiency is about 0.0017%. The SWHS could have max daily thermal efficiency of about 21%. It is concluded that the thermal efficiency was successfully improved, except for the pump one. The new SWHS with 1 m discharge head or lower is suitable for residential use. It adds less weight to a building roof and saves electrical energy for a circulation pump. It has lower cost compared to a domestic SWHS.  相似文献   

19.
In office buildings, the use of passive cooling techniques combined with a reduced cooling load may result in a good thermal summer comfort and therefore save cooling energy consumption. This is shown in the low-energy office building ‘SD Worx’ in Kortrijk (Belgium), in which natural night ventilation and an earth-to-air heat exchanger are applied. In winter, the supply air is successively heated by the earth-to-air heat exchanger and the regenerative heat exchanger, which recovers the heat from the exhaust air. In summer, the earth-to-air heat exchanger cools the ventilation air by day. In addition, natural night ventilation cools down the exposed structure which has accumulated the heat of the previous day. In this article the overall thermal comfort in the office building is evaluated by means of measuring and simulation results. Measurements of summer 2002 are discussed and compared to simulations with a coupled thermal and ventilation simulation model TRNSYS-COMIS. The simulations are used to estimate the relative importance of the different techniques. The evaluation shows that passive cooling has an important impact on the thermal summer comfort in the building. Furthermore, natural night ventilation appears to be much more effective than an earth-to-air heat exchanger to improve comfort.  相似文献   

20.
Buildings represent nearly 40 percent of total energy use in the U.S. and about 50 percent of this energy is used for heating, ventilating, and cooling the space. Conventional heating and cooling systems are having a great impact on security of energy supply and greenhouse gas emissions. Unlike conventional approach, this paper investigates an innovative passive air conditioning system coupling earth-to-air heat exchangers (EAHEs) with solar collector enhanced solar chimneys. By simultaneously utilizing geothermal and solar energy, the system can achieve great energy savings within the building sector and reduce the peak electrical demand in the summer. Experiments were conducted in a test facility in summer to evaluate the performance of such a system. During the test period, the solar chimney drove up to 0.28 m3/s (1000 m3/h) outdoor air into the space. The EAHE provided a maximum 3308 W total cooling capacity during the day time. As a 100 percent outdoor air system, the coupled system maximum cooling capacity was 2582 W that almost covered the building design cooling load. The cooling capacities reached their peak during the day time when the solar radiation intensity was strong. The results show that the coupled system can maintain the indoor thermal environmental comfort conditions at a favorable range that complies with ASHRAE standard for thermal comfort. The findings in this research provide the foundation for design and application of the coupled system.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号