首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
For a mechanical antenna system with a perfect parabolic reflector surface of diameter D the antenna gain is proportional to (Dc)2, where λc denotes the received carrier wavelength. However, for a practical system an increase in Dc is also associated with a decrease in antenna efficiency due to the imperfect reflector surface. Since the antenna efficiency is a very sensitive function of the RMS surface deviation or effectively ofDc, the loss in efficiency can more than offset the increase in directivity. The loss in efficiency results owing to the dispersion of the signal in the focal plane, with the result that only a fraction of the available signal power is collected by the focal feed. A configuration wherein several feeds are placed in the focal plane of the antenna is considered so as to capture all the available power. However, the signal phase and amplitude at the outputs of the various feeds vary randomly with time owing to the time-varying deformation of the reflector surface induced, for example, by vibrational modes set up by gravitational or thermal fields or wind. Coherent signal combining techniques based on an adaptive least-squares algorithm are investigated for nearly optimally and adaptively combining the outputs of these feeds. The performances of the two proposed versions of the least-squares algorithm are evaluated by simulations. It is shown for the example considered that both the adaptive least-squares algorithms are capable of offsetting most of the loss in the antenna gain incurred owing to reflector surface deformations.  相似文献   

2.
Objective

Fluorine MR would benefit greatly from enhancements in signal-to-noise ratio (SNR). This study examines the sensitivity gain of 19F MR that can be practically achieved when moving from 9.4 to 21.1 T.

Materials and methods

We studied perfluoro-15-crown-5-ether (PFCE) at both field strengths (B0), as a pure compound, in the form of nanoparticles (NP) as employed to study inflammation in vivo, as well as in inflamed tissue. Brains, lymph nodes (LNs) and spleens were obtained from mice with experimental autoimmune encephalomyelitis (EAE) that had been administered PFCE NPs. All samples were measured at both B0 with 2D-RARE and 2D-FLASH using 19F volume radiofrequency resonators together. T1 and T2 of PFCE were measured at both B0 strengths.

Results

Compared to 9.4 T, an SNR gain of > 3 was observed for pure PFCE and > 2 for PFCE NPs at 21.1 T using 2D-FLASH. A dependency of 19F T1 and T2 relaxation on B0 was demonstrated. High spatially resolved 19F MRI of EAE brains and LNs at 21.1 T revealed signals not seen at 9.4 T.

Discussion

Enhanced SNR and T1 shortening indicate the potential benefit of in vivo 19F MR at higher B0 to study inflammatory processes with greater detail.

  相似文献   

3.
Abstract

PZT thin films with a uniform distribution of components were prepared by plasma enhanced chemical vapor deposition (PECVD) using Pb(C2H5)4, Z (O-i-C4H9)4, Ti(O-i-C3H7)4, and oxygen. The crystallization of films was occure after annealing in the temperature range between 450 and 550°C under O2 ambient for 1 hr. The significant change of Pb concentration in PECVD PZT thin films was not observed in the relation to annealing temperature and time. The dielectric constant PECVD PZT thin films increased with the Ti content, showed the maximum value in the vicinity of morphotropic phase boundary (MPB) composition of PZT material, and decreased with the Ti content. The leakage current density of PZT (65/35) thin film of 180 nm in thickness was 3·37 × 10?7 A/cm2 at the applied voltage of 3 V. Remanent polarization increased with increasing of Zr content in the film and coercive field was nearly independent of the composition. The typical values of electrical properties were εr = 570, Ec = 90 kV/cm, and Pr = 19 μC/cm2 in the PECVD PZT (54/46) thin film of 220 nm in thickness.  相似文献   

4.
Objective

To estimate pancreas graft relaxation times and concentrations of total fat, and the intracellular lipids of non-adipose pancreatic cells (NAPC) using proton (1H) magnetic resonance spectroscopy (MRS) during cold preservation.

Materials and methods

Grafts from 11 human donors were investigated. Each pancreas was perfused in situ with histidine-tryptophan-ketoglutarate (HTK) or with University of Wisconsin solution and placed into a transport container. Temperature of the grafts was maintained at 4 ± 2 °C during transport to our hospital and MR scanning. A 1.5 T clinical scanner was used for the measurements. Single-voxel PRESS spectra were acquired using transmit–receiver head coil.

Results

Relaxation times were measured for lipid (–CH2–)n (T1, 287 ± 60 ms; T2, 27 ± 4 ms), and tissue water (T1, 670 ± 69 ms; T2, 77 ± 17 ms). Average total fat, and intracellular lipids of NAPC concentrations were 79.2 ± 100.8 (range 2.4–304.4), and 2.9 ± 1.2 mmol/kg ww, respectively.

Conclusion

We have shown that 1H-MRS is a useful tool for the estimation of pancreas graft lipid concentrations. Total pancreatic fat and especially content of intracellular lipids of NAPC are valuable measures for inspection of graft quality prior to transplantation or islet of Langerhans isolation.

  相似文献   

5.
The signal-to-noise ratio achievable with the slotted-tube resonator (STR), a fundamental type of high radiofrequency coil for nuclear magnetic resonance (NMR) experiments, was formulated in an equation. This equation is based on formulae presented by Hoult and Richards [J Magn Reson 24, 71 (1976)] and Hoult and Lauterbur [J Magn Reson 34, 425 (1979)]. The equation assumes that the sample is positioned within the homogeneous region of magnetic fluxB 1 generated by the STR, and involves no unknown factors. The NMR sensitivity of an experiment with an STR can therefore be predicted, and the equation is applicable to any nuclear species, static field strength, and dimensions of the sample and STR.  相似文献   

6.
Objective

The aim of the study was to evaluate feasibility of diffusion-weighted whole-body imaging with background body signal suppression (DWIBS) method in diagnosing Hodgkin lymphoma in pediatric patients and to compare it with 18F-FDG PET/CT as a gold standard.

Materials and methods

Eleven patients (median age 14) with newly diagnosed Hodgkin lymphoma were examined with 18F-FDG PET/CT and MRI including whole-body DWIBS sequence (b = 0, 800 s/mm2), before the oncologic treatment. About 26 locations of lymphatic tissues were evaluated visually and quantitatively using ADCmean (DWIBS) and SUVmax (18F-FDG PET/CT), respectively.

Results

All affected lymph node regions (n = 134) diagnosed in 18F-FDG PET/CT were found with DWIBS, presenting decreased diffusion. Significant correlation was found between ADC and SUV values (R2 = − 0.37; p = 0.0001). Nevertheless, additional 33 regions were recognized only by DWIBS. They were significantly smaller than regions diagnosed by both methods.

Discussion

Agreement between DWIBS and 18F-FDG PET/CT for detection and staging of malignant lymphoma is high. DWIBS can be used for the evaluation of pediatric Hodgkin lymphoma.

  相似文献   

7.
Abstract

Using the composite resonator with additional thick AlN film with the FWHM of rocking curve of 2.53° under investigation, the bulk acoustic wave attenuation constant and sound velocity along c-axis were directly measured. The method of High Overtone Bulk acoustic wave Resonator (HBAR) spectroscopy based on frequency, measurements of the positions of the resonator peculiarities of phase and amplitude of electromagnetic wave reflection coefficient from composite resonator structure was applied. The method provides attenuation and velocity measurement in a wide frequency band, using the same sample. For the measurements, standard and modified HBAR spectroscopy based on the analysis of only parallel resonance properties of composite resonator structures were used.  相似文献   

8.
Resonant frequency temperature coefficient is dependent on material properties, resonator dimensions and vibration mode. It could be effectively tuned by the resonator dimensions or by the domain structure in ferroelectric crystals. Optimum dimensions for the zero temperature coefficient resonator are calculated for ring radial vibration mode as a function of resonator dimensions (r 2/r 1 = 3.8 for hard PZT ceramics, APC841 type). There are similar results of the temperature coefficient calculations for PZT ceramics and crystal resonators. The temperature coefficient is generally smaller for higher overtones of resonant mode.  相似文献   

9.
Objective

To investigate the effect of inter-operator variability in arterial input function (AIF) definition on kinetic parameter estimates (KPEs) from dynamic contrast-enhanced (DCE) MRI in patients with high-grade gliomas.

Methods

The study included 118 DCE series from 23 patients. AIFs were measured by three domain experts (DEs), and a population AIF (pop-AIF) was constructed from the measured AIFs. The DE-AIFs, pop-AIF and AUC-normalized DE-AIFs were used for pharmacokinetic analysis with the extended Tofts model. AIF-dependence of KPEs was assessed by intraclass correlation coefficient (ICC) analysis, and the impact on relative longitudinal change in Ktrans was assessed by Fleiss’ kappa (κ).

Results

There was a moderate to substantial agreement (ICC 0.51–0.76) between KPEs when using DE-AIFs, while AUC-normalized AIFs yielded ICC 0.77–0.95 for Ktrans, kep and ve and ICC 0.70 for vp. Inclusion of the pop-AIF did not reduce agreement. Agreement in relative longitudinal change in Ktrans was moderate (κ = 0.591) using DE-AIFs, while AUC-normalized AIFs gave substantial (κ = 0.809) agreement.

Discussion

AUC-normalized AIFs can reduce the variation in kinetic parameter results originating from operator input. The pop-AIF presented in this work may be applied in absence of a satisfactory measurement.

  相似文献   

10.
Objective

To implement magnetic resonance fingerprinting (MRF) on a permanent magnet 50 mT low-field system deployable as a future point-of-care (POC) unit and explore the quality of the parameter maps.

Materials and methods

3D MRF was implemented on a custom-built Halbach array using a slab-selective spoiled steady-state free precession sequence with 3D Cartesian readout. Undersampled scans were acquired with different MRF flip angle patterns and reconstructed using matrix completion and matched to the simulated dictionary, taking excitation profile and coil ringing into account. MRF relaxation times were compared to that of inversion recovery (IR) and multi-echo spin echo (MESE) experiments in phantom and in vivo. Furthermore, B0 inhomogeneities were encoded in the MRF sequence using an alternating TE pattern, and the estimated map was used to correct for image distortions in the MRF images using a model-based reconstruction.

Results

Phantom relaxation times measured with an optimized MRF sequence for low field were in better agreement with reference techniques than for a standard MRF sequence. In vivo muscle relaxation times measured with MRF were longer than those obtained with an IR sequence (T1: 182 ± 21.5 vs 168 ± 9.89 ms) and with an MESE sequence (T2: 69.8 ± 19.7 vs 46.1 ± 9.65 ms). In vivo lipid MRF relaxation times were also longer compared with IR (T1: 165 ± 15.1 ms vs 127 ± 8.28 ms) and with MESE (T2: 160 ± 15.0 ms vs 124 ± 4.27 ms). Integrated ΔB0 estimation and correction resulted in parameter maps with reduced distortions.

Discussion

It is possible to measure volumetric relaxation times with MRF at 2.5 × 2.5 × 3.0 mm3 resolution in a 13 min scan time on a 50 mT permanent magnet system. The measured MRF relaxation times are longer compared to those measured with reference techniques, especially for T2. This discrepancy can potentially be addressed by hardware, reconstruction and sequence design, but long-term reproducibility needs to be further improved.

  相似文献   

11.
Xin Liu  Xinmei Liu 《组合铁电体》2019,197(1):121-132
Abstract

A series of SnO2 nanocrystallines decorated g-C3N4 architectures were synthesized using a facile solvothermal method. The structural, morphological, and optical properties of the as-prepared nanocomposites were characterized in detail, indicating that SnO2 nanocrystallines with diameter ~ 4?nm were well-dispersed on the surface of g-C3N4. The photocatalytic activity of the composites was investigated by degrading rhodamine B (RhB) under visible light irradiation. The CNS2 heterostructure exhibits enhanced photocatalytic activity than bare SnO2 and g-C3N4. Kinetic study revealed a promising degradation rate constant of 0.0593?min?1 for the CNS2, which is 118 and 7 times higher than that of pure SnO2 and g-C3N4, respectively. What’s more, the CNS2 still retained the photocatalytic activity after three cycle measurements. The enhanced photocatalytic performances of the nanocomposite may be due to its large surface area (116.2 m2/g), appropriate ratio of SnO2/g-C3N4 and the compact structure of the junction between the SnO2 nanocrystallines and the g-C3N4, which inhibits the recombination of photogenerated electrons and holes.  相似文献   

12.
Abstract

RuO2/PbZr0.52Ti0.48O3 multilayers have been prepared by pulsed laser deposition and characterised by Grazing Incident Angle Bragg Diffraction and scanning electron microscopy. The results are correlated with the different deposition conditions and post-growth thermal annealing. The structure of the paraelectric pyrochlore phase (Pb2(Zr,Ti)2O6) and its stability relative to the ferroelectric perovskite is discussed.  相似文献   

13.
Abstract

The europium doped Sr2SiO4 phosphors were prepared by the combustion synthesis technique. The prepared samples of europium doped Sr2SiO4 phosphors were characterized by the X-Ray Diffraction (XRD), Ultraviolet Visible spectroscopy (UV), Fourier Transform Infrared Spectroscopy (FT-IR), Field Emission Scanning Electron Microscopy (FE-SEM), Energy Dispersive Spectra (EDS) and Photoluminescence Technique (PL). The orthorhombic crystal structure of the prepared sample was confirmed by using XRD. The formation of fiber like nano structured nature was confirmed by the images captured using the FE-SEM technique. The band gap energies were calculated using the UV-Visible spectra of the samples and these band gap energies were observed as 4.5826?eV for Sr2SiO4 and 4.1748?eV for Eu (5?m%) doped Sr2SiO4. The two different PL emission peaks were observed for two different excitation wavelengths. One peak was observed at the 590?nm under 393?nm excitation and another peak was observed at the 615?nm under 408?nm excitation. The CIE color coordinates of the Eu3+ doped Sr2SiO4 phosphors are x?≈?0.6615, y?≈?0.3382 (red color) observed for 408?nm excitation and x?≈?0.5636, y?≈?0.4356 (orange) observed for 393?nm excitation calculated using the color calculator program radiant imaging.  相似文献   

14.
探讨了带中继谐振器的磁耦合谐振式无线电能传输MCR-WPT(magnetic coupling resonant-wireless power transfer)系统的传输效率优化问题。通过构建和分析带中继线圈的等效电路模型,引入功率传输性能参数|Sij|2推导出当中继线圈和接收线圈位置固定时,发射线圈和带中继谐振器之间的最佳耦合系数的闭合形式解,进而确定发射线圈和带中继谐振器之间的最优距离,实现总系统传输效率最大化。通过线圈设计及相关实验,验证了分析结果与实验结果的一致性。研究结果表明,MCR-WPT系统可方便配置最佳耦合系数以实现电能传输效率最大化,为带中继谐振器的WPT系统效率优化提供重要参考。  相似文献   

15.
Objective

To determine whether a multi-feed, loop-dipole combined approach can be used to improve performance of rectangular dielectric resonator antenna (DRA) arrays human brain for MRI at 7 T.

Materials and methods

Electromagnetic field simulations in a spherical phantom and human voxel model “Duke” were conducted for different rectangular DRA geometries and dielectric constants εr. Three types of RF feed were investigated: loop-only, dipole-only and loop-dipole. Additionally, multi-channel array configurations up to 24-channels were simulated.

Results

The loop-only coupling scheme provided the highest B1+ and SAR efficiency, while the loop-dipole showed the highest SNR in the center of a spherical phantom for both single- and multi-channel configurations. For Duke, 16-channel arrays outperformed an 8-channel bow-tie array with greater B1+ efficiency (1.48- to 1.54-fold), SAR efficiency (1.03- to 1.23-fold) and SNR (1.63- to 1.78). The multi-feed, loop-dipole combined approach enabled the number of channels increase to 24 with 3 channels per block.

Discussion

This work provides novel insights into the rectangular DRA design for high field MRI and shows that the loop-only feed should be used instead of the dipole-only in transmit mode to achieve the highest B1+ and SAR efficiency, while the loop-dipole should be the best suited in receive mode to obtain the highest SNR in spherical samples of similar size and electrical properties as the human head.

  相似文献   

16.
Abstract

Highly c-axis oriented single phase Na0.5K0.5NbO3 (NKN) thin films have been deposited onto polycrystalline Pt80lr20 substrates and SiO2/Si(001) wafers using pulsed laser ablation of stoichiometric ceramic target. Strong self-assembling of NKN films along the [001] direction has been observed. Properties of NKN/Pt thin film structures have been successfully tailored by oxygen pressure control from the ferroelectric state, characterized by the remnant polarization of 12 uC/cm2, dielectric constant ? ~ 520 and tan δ ~ 0.024 @ 100 kHz, to superparaelectric state with tan δ as low as 0.003 and ? = 210 with very small 1.7% dispersion in the frequency domain 0.4–100 kHz and less than 10% variation in the temperature range 77–415 K. NKN films grown onto SiO2/Si(001) substrates show quadrupled super-lattice structure along c-axis, loss tan δ less than 0.01, and ? ~ 110 @ 1 MHz. C-V measurements for Au/NKN (270nm)/SiO2/Si MFIS-diode structure yield memory window of 3.26 V at the programmable voltage of 8 V.  相似文献   

17.
Objective

19F MRI requires biocompatible and non-toxic soluble contrast agents with high fluorine content and with suitable 19F relaxation times. Probes based on a DOTP chelate with 12 magnetically equivalent fluorine atoms (DOTP-tfe) and a lanthanide(III) ion shortening the relaxation times were prepared and tested.

Methods

Complexes of DOTP-tfe with trivalent paramagnetic Ce, Dy, Ho, Tm, and Yb ions were synthetized and characterized. 19F relaxation times were determined and compared to those of the La complex and of the empty ligand. In vitro and in vivo 19F MRI was performed at 4.7 T.

Results

19F relaxation times strongly depended on the chelated lanthanide(III) ion. T1 ranged from 6.5 to 287 ms, T2 from 3.9 to 124.4 ms, and T2* from 1.1 to 3.1 ms. All complexes in combination with optimized sequences provided sufficient signal in vitro under conditions mimicking experiments in vivo (concentrations 1.25 mM, 15-min scanning time). As a proof of concept, two contrast agents were injected into the rat muscle; 19F MRI in vivo confirmed the in vivo applicability of the probe.

Conclusion

DOTP-based 19F probes showed suitable properties for in vitro and in vivo visualization and biological applications. The lanthanide(III) ions enabled us to shorten the relaxation times and to trim the probes according to the actual needs. Similar to the clinically approved Gd3+ chelates, this customized probe design ensures consistent biochemical properties and similar safety profiles.

  相似文献   

18.
ABSTRACT

BaZr0.2Ti0.8O3 films were prepared using inorganic zirconate and the crystalline microstructure, surface morphology and ferroelectric properties of BZT films were investigated. It is found that the crystal structure of the films belongs to tetragonal phase and is close to cubic phase. The obvious polarization versus electric voltage (P-V) hysteresis loop and butterfly-shaped ?-V curves were observed in BaZr0.2Ti0.8O3 films. The remanent polarization (2P r) and the coercive field (2E C) of BaZr0.2Ti0.8O3 films obtained from the hysteresis loop are 0.1669 μC/cm2 and 21.53 kV/cm, respectively. The dielectric constant and tunability of the BaZr0.2Ti0.8O3 films are 113 and 10.2%, respectively.  相似文献   

19.
Abstract

We reported herein the temperature-dependent dielectric properties of K0.8M0.4Ti1.6O4 (M?=?Ni, Zn) lepidocrocite titanate ceramics at the frequency f of 103, 104 and 105 Hz. This titanate is an example of layered alkali titanium oxides possessing two-dimensional (2D) sheets of edge-shared TiO6 octahedra, in contrast to other widely studied materials with mostly corner-shared TiO6 motifs. The giant dielectric constants ε′ ~104 and the dielectric losses tan δ ~ 0.5–2 were obtained upon heating from RT to 250?°C. These values in our water-free ceramics are comparable to those previously reported in lepidocrocite titanate and related structures containing up to 15%wt water. The results were explained considering (i) Maxwell-Wagner polarization of interlayer species, and (ii) the possible formation of internal barrier layer capacitors (IBLCs) via the oxidized surfaces.  相似文献   

20.
Objective

Oxygen-loaded nanobubbles have shown potential for reducing tumour hypoxia and improving treatment outcomes, however, it remains difficult to noninvasively measure the changes in partial pressure of oxygen (PO2) in vivo. The linear relationship between PO2 and longitudinal relaxation rate (R1) has been used to noninvasively infer PO2 in vitreous and cerebrospinal fluid, and therefore, this experiment aimed to investigate whether R1 is a suitable measurement to study oxygen delivery from such oxygen carriers.

Methods

T1 mapping was used to measure R1 in phantoms containing nanobubbles with varied PO2 to measure the relaxivity of oxygen (r1Ox) in the phantoms at 7 and 3 T. These measurements were used to estimate the limit of detection (LOD) in two experimental settings: preclinical 7 T and clinical 3 T MRI.

Results

The r1Ox in the nanobubble solution was 0.00057 and 0.000235 s−1/mmHg, corresponding to a LOD of 111 and 103 mmHg with 95% confidence at 7 and 3 T, respectively.

Conclusion

This suggests that T1 mapping could provide a noninvasive method of measuring a > 100 mmHg oxygen delivery from therapeutic nanobubbles.

  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号