1.
XLPE绝缘电老化中局放特性试验研究   总被引:3,自引:9,他引:3  
利用TE571局放检测仪和超宽频带局放(PD)检测系统研究了XLPE电缆绝缘试样加速电老化过程中判断试样老化状态的局放统计参量和单次放电波形特性。结果表明,电老化过程中单次放电时域波形的上升沿变陡,从老化前50 ns降低为老化50 h的8 ns;脉冲幅值从老化前的2 mV增加到老化50 h的17 mV;放电频谱中特征峰的位置随着老化程度的加剧向高频方向移动,从老化前<15 MHz增加到老化50 h的<50 MHz和125~200MHz。该研究为放电单次波形检测技术评估XLPE电力电缆绝缘状态的基础研究。  相似文献   

2.
在大型电机运行过程中 ,由于电、热、机械和环境应力的联合作用 ,其绝缘性能会逐渐下降。在实验室中通过多因子加速老化实验模拟了电机线棒在实际运行中的老化。对不同老化程度的线棒 ,使用超宽频带局部放电检测技术测试了试样的局部放电 ,并分析了放电信号在时域和频域随老化时间的变化情况。实验结果表明 ,随着试样线棒绝缘的不断劣化 ,放电脉冲时域波形的高频振荡不断加剧 ,脉冲宽度不断减小 ;同时 ,频域中的高频分量越来越丰富 ,谱峰逐渐增多 ,并且在高频段出现特征峰分布  相似文献   

3.
研究变压器油纸绝缘局部放电(PD)的发展过程对于特高压换流变压器的运行维护十分重要。为此,对典型油纸复合绝缘缺陷模型在直流电压长期(100 h)作用下的局部放电信号进行了统计分析;根据其统计特征图谱,将直流局部放电发展过程划分为4个阶段。此外,还采用无感电阻测量直流局部放电单个脉冲波形;并对直流电压长期作用下的油浸绝缘纸板表面形貌变化进行了观测。试验结果表明,直流电压下的局部放电脉冲的上升沿在10~100 ns范围内,首脉冲持续时间约500 ns,其余振荡脉冲脉宽在600~900 ns范围内;估算得出单次直流放电脉冲能量在0.01~0.1 J范围内。此外,研究发现绝缘纸板的表面会在针电极电蚀作用下产生"凹坑",这为实现基于多信息融合的直流局部放电发展趋势预测奠定了基础。  相似文献   

4.
为了探索脉冲电应力作用下高压绝缘栅双极型晶体管(IGBT)器件绝缘材料的局部放电特性,建立高频高压脉冲作用下的局部放电测量平台,系统研究了电压幅值、脉冲重复频率、上升沿时间和脉宽对聚酰亚胺薄膜局部放电特性的影响规律。结果表明:随着电压幅值从3 kV增加至11 kV,脉冲上升沿处的局部放电信号幅值逐渐增大,而放电时延逐渐减小;随着脉冲重复频率从50 Hz增大至100 kHz,上升沿的放电时延逐渐增大但局部放电信号幅值几乎不变;随着上升沿时间从136 ns增大至300 ns,放电时延逐渐增大且更加分散,局部放电信号幅值逐渐减小且更加紧密;与脉宽为1μs的情况相比,脉宽为500 ns时局部放电信号幅值更大且放电时延更小。该结果可为高压大功率电力电子装置中固态开关的绝缘老化和状态监测提供重要科学依据。  相似文献   

5.
为研究不同老化状态下油纸绝缘沿面放电的发展特性,分析老化程度对放电特性的影响,进而提出表征老化程度和放电危险度的特征量。通过加速热老化制备了4种不同老化程度的油纸绝缘试品,在阶升电压下获得了其局部放电发展过程中的谱图和脉冲序列特性。研究发现,沿面放电脉冲多以脉冲簇群形式出现且有脉冲幅值逐渐增大,脉冲波形上升沿、下降沿快于空气中放电的情形;油纸绝缘老化程度对沿面放电的起始电压和击穿电压影响不大,但对放电量的威布尔尺度参数α值和平均放电功率P影响显著;连续放电时间差Δt对放电发展阶段和绝缘老化程度反应灵敏,可用于放电危险度评估指标。  相似文献   

6.
局部放电测量广泛应用于各种电力设备的绝缘状况诊断中,对于XLPE电缆,局部放电可以检测到各种绝缘缺陷,例如电缆加工、运行以及安装过程中的人为缺陷,以及绝缘层中的气隙和电树枝老化。然而,当局部放电脉冲在电缆中传播时,由于衰减的原因,脉冲波形发生了变化。因此,对于电缆局部放电测量,了解局部放电脉冲在电缆中传播时的变化规律是非常关键的,因此本文针对电缆局部放电脉冲传播时,脉冲波形的变化进行了深入分析,并且讨论的了不同耦合带宽对信号检测的影响,得出:当电缆发生局部放电时,脉冲信号幅值随着传播距离的增加迅速衰减,但脉冲视在放电量衰减幅度相对较小;同时,宽带耦合具有较高的灵敏度,但是其电荷校准曲线误差较大,并且会导致信噪比降低,缺陷检出度下降;窄带耦合虽然能够获得较为准确地电荷校准曲线,却会导致脉冲波形发生叠加,影响故障点定位;所以,在实际应用中,需要根据实际需求,确定检测带宽。  相似文献   

7.
针对XLPE电缆中存在水树缺陷引起局部放电导致电缆绝缘迅速劣化的问题,提出了一种通过注入修复液修复电缆水树缺陷抑制电缆局部放电的方法,从XLPE电缆试样局部放电特征及缺陷表面微观形貌结构两方面研究修复液对XLPE电缆局部放电的影响。采用水针电极法加速XLPE电缆绝缘水树老化,并对生成水树缺陷的电缆试样进行注入式修复,测试分析修复前后电缆试样的局部放电特征,并对修复后电缆试样缺陷处的表面形貌特征进行分析。此外,建立XLPE电缆水树缺陷的有限元模型,结合水树缺陷处电场仿真进一步阐述修复液对XLPE电缆局部放电的影响机理。结果表明:修复后XLPE电缆局部放电的放电幅值和放电次数均大幅减小,表明修复液可以抑制电缆局部放电的发展,减缓XLPE电缆绝缘的劣化。  相似文献   

8.
高频连续脉冲作用下电机绝缘局部放电信号的提取   总被引:9,自引:2,他引:9  
局部放电是引起PWM变频电机绝缘在高频连续脉冲条件下发生老化的重要因素之一,严重时将导致电机绝缘的击穿.由于高频连续脉冲的上升时间为ns级且幅值为kV级,既加剧了电机绝缘的老化程度,也对局部放电检测系统提出了高要求.为了有效提取局部放电信号,本文提出一种新型的脉冲电流传感器(ICS).基于该传感器建立了一套局部放电测试系统,以牵引电机电磁线绞线对为试样进行局部放电测试.测量结果表明该测试系统能有效提取平顶区域的局部放电信号,对研究脉冲电压作用下的局部放电对绝缘老化的影响具有重要价值.  相似文献   

9.
高频变压器运行过程中油纸绝缘承受严酷的电热应力,绝缘系统容易过早失效.为了研究高频脉冲电压对油纸绝缘局部放电特性的影响,搭建了高频脉冲电压下的局部放电试验平台,开展局部放电试验,研究油纸绝缘在高频脉冲电压下的局部放电特性,并与工频电压下的局部放电特性进行对比.结果表明:高频脉冲电压下局部放电主要发生在电压的上升沿和下降沿,高频脉冲电压下的局部放电幅值远高于工频下的局部放电幅值,在10 kHz附近存在频致拐点,且高频脉冲下油纸试样出现直击现象;究其原因是高频产生较高的电压上升率,改变了缺陷区域的局部场强和高频电热耦合效应,从而导致了局部放电强度的变化.  相似文献   

10.
局部放电是引起PWM变频电机绝缘在高频连续脉冲条件下发生老化的重要因素之一,严重时将导致电机绝缘的击穿。由于高频连续脉冲的上升时间为ns级且幅值为k V级,故既加剧了电机绝缘的老化程度,也对局部放电检测系统提出了高要求。为了有效提取局部放电信号,提出了一种基于声电传感器构成的超声检测系统,用于高频局部放电的研究。  相似文献   

11.
高压交联聚乙烯电缆局部放电脉冲的时频特性识别方法   总被引:1,自引:1,他引:0  
高压电力电缆局部放电(PD)测量中,进行绝缘诊断和状态评估的一个重要方面是局部放电信号(PDs)的识别和放电源分离。传统的基于局部放电幅值大小检测的相位统计分析,不足以实现有效的诊断、风险评估和基于状态的维护。为此,从理论上研究了频率(即等效带宽∫eq)一时间(即等效时间长度teq)分离技术,通过∫eq-teq。平面的簇脉冲来识别局部放电脉冲,并求解出局部放电脉冲信号在∫eq-teq。平面形成紧凑的簇所需要的相似属性参数。Xi。PE绝缘样片缺陷实验将气隙放电、沿面放电和电晕放电不同类型脉冲映射到∫eq-teq。平面;XI。PE电缆缺陷实验将不同位置的相同缺陷放电脉冲映射到∫eq-teq平面。结果表明,不同类型的缺陷产生的PD脉冲信号能有效形成自己的簇,电缆不同位置的缺陷产生的PD信号也能形成不同的簇。可见,∫eq-teq识别技术可为高压XI。PE电缆的缺陷类型及放电源分离提供判断依据。  相似文献   

12.
This paper presents the results of laboratory investigations of partial discharge (PD) in field aged XLPE underground power cables. PD measurements were made on sixty-one cable samples over a three year period. When PD was detected, the magnitude was measured and a site location was determined. PD site locations were predicted using time delay estimations between PD pulses arriving at opposite ends of the test cable. Fourteen of the samples tested had detectable levels of PD. Some of these PD sites extinguished during the measurement period and were returned to rated voltage aging. When samples had continuously active PD sites, they were either dissected or returned to the aging test. Four sites of this type were found allowing two for dissection and two for aging. Seven of the samples failed after PD measurements. All seven failed near the predicted PD location. During the PD testing, no test cables contained PD which initiated at or below operating voltage. When PD detection equipment was monitoring cables which failed, the failures occurred from 2 to 80 minutes after the presence of PD pulses was detected  相似文献   

13.
高压交联聚乙烯电缆高频损耗对局放脉冲识别的影响   总被引:1,自引:1,他引:0  
等效带宽W-等效时间长度T分离技术一般通过W-T的2维笛卡尔坐标系的簇脉冲来识别局部放电(partial discharge,PD)脉冲。局部放电信号沿交联聚乙烯(cross Linked polyethylene,XLPE)电缆传播的高频损耗影响W-T簇分类。为此,提出1个近似传播分析模型,避开传播参数测量法对于长电缆的局限性和分析解方法难以测量半导电层复合介电常数的问题,将其用于分析局放脉冲的W和T与传播距离的关系;同时计算了高斯型PD脉冲的W和T,以及W、T与传播距离的数学关系模型;最后采用近似传播分析模型和数学关系模型针对实际电缆进行了仿真与测量。结果表明高频损耗对W分离影响较小,而对T分离在远距离时影响较大。可见,W-T簇分类对离测量点500m内的PD信号具有良好效果,而对远距离的PD信号主要依靠W来分离。  相似文献   

14.
XLPE电缆中局部放电脉冲传播特性的实验研究   总被引:7,自引:0,他引:7  
对模拟局部放电的窄脉冲和陡前沿脉冲沿电缆的传播特性进行了实验研究。在两段不同长度的电缆首端分别注入窄脉冲和陡前沿脉冲 ,同时记录首末端波形 ;分析了不同频率下脉冲在电缆中的传播和衰减情况 ,并提出了电缆局放检测用传感器频率的选择原则。  相似文献   

15.
为去除XLPE电缆局部放电现场检测中的随机脉冲干扰,采用等效时频法提取脉冲特征,对特征进行自适应模糊聚类,以相位集中度为指标区分局放与随机干扰.对现场数据分析处理的结果表明,该方法能够有效去除信号中的随机脉冲干扰,为评估XLPE电缆的绝缘状态提供了较好的理论和实践依据.  相似文献   

16.
EL (electroluminescence) in XLPE (crosslinked polyethylene) subjected to impulses of various amplitudes, shapes and repetition rates has been investigated. Defects that could occur in the polymeric insulation of underground HV cables were simulated by embedding semicon protrusions in XLPE to create highly divergent electric fields. Time resolved measurement of the EL pulses emitted during positive, negative or alternating polarity impulses has shown that the EL pulses are grouped into two distinct time periods between which there is no EL activity. The EL emission probability increased with fall time of the impulse voltage but was independent of the impulse rise time. A study of electroluminescence characteristics from unaged and aged XLPE, subjected to a pair of positive and negative impulses, indicated that the charge trapped in the polymeric insulation during aging plays an important role during impulse application and could affect insulation failure  相似文献   

17.
抗强电磁干扰的高电压同步控制系统   总被引:1,自引:1,他引:0  
为了在强电磁干扰环境中控制"双脉冲"实验的放电时序,研制了一台高电压同步控制系统。在采用多种常规的抗电磁干扰方法(如电磁屏蔽、光电隔离、独立电源和接地等)的基础上,该系统的核心抗干扰技术是选用高反向偏置的可控硅作为高电压脉冲变压器原边放电的控制开关。该系统由1个低电压多路时延发生器和5个独立的高电压脉冲发生器组成,它们分别放置在各自的电磁屏蔽机箱内,采用电池或电源隔离变压器供电,独立接地,时延发生器和高电压脉冲发生器之间采用光纤连接和光耦隔离。该系统可以输出5路25 kV的触发电压脉冲,各路之间时间间隔为0~1 s,最小调节时间步长为10 ns。该控制系统被成功地用于"双脉冲"放电实验中,实验证明它具有很好的抗电磁干扰能力。  相似文献   

18.
笔者介绍了直流下局部放电脉冲波形测量系统的组建以及测量电阻的校验。利用该试验系统对模拟换流变压器油纸绝缘的5种典型缺陷模型进行了局放脉冲波形测量。试验结果表明:直流下油纸绝缘中缺陷放电稳定,脉冲波形无振荡分量和过冲,且不随电压变化而发生畸变。在对典型脉冲波形进行预处理的前提下,使用形状参数法、自相关函数法、AR模型参数法以及Renvi信息量进行了波形特征参数提取。所得结果为深入研究直流下油纸绝缘中局部放电机理、局放在线监测系统的频率特性以及放电类型的波形识别提供了实验依据。  相似文献   

19.
XLPE电缆局放脉冲频谱分析及传感器选频   总被引:2,自引:1,他引:2  
为选择好局放测量传感器的频带,用指数衰减函数、梯形函数、高斯函数和三角函数数学描述了交联聚乙烯(XLPE)电缆中的局放脉冲并定量分析了局放脉冲的上限频率,其结果和实测局放脉冲经快速付里叶变换后的频谱基本吻合。用最小二乘法拟合信号各频率分量在XLPE电缆中的三特性并给出最优表达式后,把输出信号和输入信号比值在0.7~1范围内作为局放能量的集中区域,在此区域内得到检测不同长度XLPE电缆局放所需传感器的频带要求。对于5m长的电缆接头,传感器上限频率需>168.9MHz,较长电缆局放测量则需数十MHz。  相似文献   