共查询到18条相似文献,搜索用时 593 毫秒
1.
2.
电子能量损失符合谱仪的一维位置灵敏探测器的读出系统 总被引:1,自引:1,他引:0
介绍了用于电子能量损失符合谱仪的一维位置灵敏探测器的读出系统。一维位置灵敏探测器可以大大提高谱仪的探测效率。其读出系统包括电荷灵敏前置放大器、主放大器、位置信号采集板和接口电路。使用自己设计的信号源对系统进行了测试,取得了较好结果。 相似文献
3.
用于束流剖面探测的位置灵敏探测器 总被引:1,自引:2,他引:1
介绍了用于剩余气体束流剖面探测系统的位置灵敏探测器的原理和结构。测试了探测器的性能,得到了位置分辨、位置线性、探测效率及探测器本底。 相似文献
4.
5.
6.
7.
本文介绍了一台锯齿形极位置灵敏电离室,它是在普通电离室的基础上把阳极改变为锯齿形结构,从而实现对带电业子位置的测定,用^241Am源的α粒子对探测器的性能进行了测试,得到的能量分辨为2%,位置分辨好于2mm。 相似文献
8.
9.
由80cm大面积位置灵敏电离室与一维位置塑料闪烁体组成的探测器系统首次在中能重离子核反应实验中进行了测试。电离室可以测量较重的低能离子,有较好的粒子鉴别能力,能给出能量信息及两维位置信息。闪烁体能使该系统用于较高能量轻带电粒子的测量,它能给出能量及一维位置信息,与电离室配合可以进行元素鉴别。 相似文献
10.
11.
12.
ZHU Jie LIU Shi-Tao LEI Xiao-Wen YAN Tian-Xin XU Zi-Zong WANG Zhao-Min* 《核技术(英文版)》2005,16(4):238-243
1 Introduction In recent years a great effort has been made in developing compact gamma camera to improve nu-clear medical imaging. Conventional Anger gamma camera[1] uses a NaI(Tl) scintillator block and an array of photomultiplier tube. It has large size and poor spa-tial resolution, thus it is not suitable for small object image. Though the gamma camera using planar crystal coupled with position sensitive photomultiplier tube (PSPMT[2]) could greatly improve spatial resolu-tion,[3-5] pl… 相似文献
13.
本文对电荷除法型位置灵敏探测器的特征和结构进行了描述。并给出了初步的实验结果。 相似文献
14.
15.
《Fusion Engineering and Design》2014,89(9-10):2268-2271
The reliable monitoring of the position of an encapsulated activation sample is essential to ensure the diagnostic accuracy and the maintenance of the ITER neutron activation system (NAS). Conventional methods using optical or electrical detectors to determine the capsule position is difficult to be used in the ITER NAS because of limited space as well as extremely high electromagnetic and radiation environment. In this study, new methods using the flow rate change inside a transfer tube assembly and the propagation characteristics of sound wave are investigated for the reliable determination of the capsule position. Experimental results confirm that the abrupt reduction of flow rate in the transfer tube assembly provides information for the final position of the capsule with a high spatial resolution less than 1 mm. The variation of flow rate is also found to indicate the operational status of the pneumatic transfer system. In the case of capsule lost accident, a laboratory scale test has demonstrated that the exact position of the lost capsule can be determined by the sound wave method in which the time delay between an incident sound signal and a reflected one by the capsule is measured so as to provide the position of the capsule with a spatial resolution of 0.2 m. These two capsule position monitoring methods are expected to improve the accuracy, operational stability, and the ability to handle the accident in the ITER NAS. 相似文献
16.
In the 3rd generation synchrotron light source,beside the orbit,air disturbance and ground vibration also could affect the position stability of photon beam in synchrotrons radiation measurement.In the condition of implementation of orbit feedback system at SSRF,the measured position stability of photon beam in synchrotrons radiation measurement station was presented in this paper.And then the improvement methods of position stability of photon beam were discussed.Finally the measured result was shown when the designed feedback system is implemented to improve the position stability of photon beam. 相似文献
17.
秦山第二核电厂棒位系统使用PLC软件对控制棒位置进行实时监视,对异常现象进行及时判别,大大提高了控制棒位置故障诊断的及时性、准确性。实现了对棒位故障的判别、记录,实现了测量通道性能判定的自动化。对该软件的功能及其使用效果进行了介绍。 相似文献
18.
In pursuit of high-precision beam position measurements at micrometers or submicrometers for the Shanghai soft X-ray free-electron laser (SXFEL) facility which is under construction in the vicinity of the Shanghai Synchrotron Radiation Facility,a high Q cavity beam position monitor (CBPM) with a resonant frequency of 4.7 GHz is developed by the Shanghai Institute of Applied Physics,and the relevant BPM electronics with a dedicated RF front end,and a digital BPM,are completed.The cavity design,cold test,system architecture,and first beam test are performed at the Shanghai deep ultraviolet free-electron laser (Zhao et al.in Nucl Instrum Meth A 528(1-2):591-594,2004.doi:10.1016/j.nima.2004.04.108) facility.Results of the beam experiment show that the performance of the CBPM is consistent with basic expectations,and the beam position resolution can fulfill the requirements for the SXFEL project if the beam conditions are optimized. 相似文献