首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 1 毫秒
1.
A simple and versatile low-flow interface has been developed for interfacing capillary electrophoresis (CE) with electrospray ionization (ESI) mass spectrometry. This low-flow interface showed better sensitivity than a conventional sheath liquid interface, primarily attributed to a low dilution factor and a reduction in the sprayer orifice size. The interface was also found to be more tolerant to the presence of nonvolatile salts. Because of tolerance to the surfactant SDS, this interface can be used to couple micellar electrokinetic chromatography (MEKC) with ESI-MS. The performance of the interface in an MEKC-MS application, as demonstrated in the analysis of triazines, was significantly better than that obtained with a conventional sheath liquid interface. Moreover, this interface can be easily used for large-volume sample-stacking (LVSS) applications. Using a series of phenols as a test case, an approximate 500-fold enrichment was achieved by LVSS in conjunction with the low-flow CE/MS interface described.  相似文献   

2.
A novel, rugged capillary electrophoresis-electrospray ionization (CE-ESI) interface where the separation column, an electrical porous junction, and the spray tip are integrated on a single piece of a fused-silica capillary is described. ESI is accomplished by applying an electrical potential through an easily prepared porous junction across a 3-4-mm length of fused silica. A stable electrospray is produced at nanoflow rates generated in the capillary by electrophoretic and electroosmotic forces. The interface is particularly well suited for the detection of low-femtomole levels of proteins and peptides. The ruggedness of this interface was evident by the continuous operation of the same column for over a 2-week period with no detectable deterioration in separation or electrospray performance. The new interface was used for the LC-ESI-MS separation and analysis of peptides and proteins. Injection of 25 fmol of [Glu1]-fibrinopeptide B using the new device produced a CE-ESI-MS electropherogram with a signal-to-noise ratio of over 100 for this peptide.  相似文献   

3.
A method for the determination of underivatized amino acids based on capillary electrophoresis coupled to electrospray ionization mass spectrometry (CE-ESI-MS) is described. To analyze free amino acids simultaneously a low acidic pH condition was used to confer positive charge on whole amino acids. The choice of the electrolyte and its concentration influenced resolution and peak shape of the amino acids, and 1 M formic acid was selected as the optimal electrolyte. Meanwhile, the sheath liquid composition had a significant effect on sensitivity and the highest sensitivity was obtained when 5 mM ammonium acetate in 50% (v/v) methanol-water was used. Protonated amino acids were roughly separated by CE and selectively detected by a quadrupole mass spectrometer with a sheath flow electrospray ionization interface. Under the optimized conditions, 19 free amino acids normally found in proteins and several physiological amino acids were well determined in less than 17 min. The detection limits for basic amino acids were between 0.3 and 1.1 mumol/L and for acidic and low molecular weight amino acids were less than 6.0 mumol/L with pressure injection of 50 mbar for 3 s (3 nL) at a signal-to-noise ratio of 3. This method is simple, rapid, and selective compared with conventional techniques and could be readily applied to the analysis of free amino acids in soy sauce.  相似文献   

4.
A tapered capillary tip containing a beveled edge was developed for use in sheathless capillary electrophoresis/electrospray mass spectrometry (CE/ESI-MS). The optimal flow rate of a 75-microm-i.d., 90-microm-o.d. beveled tapered capillary tip was similar to a conventional flat tapered tip with a 25-microm orifice. Using a mixture of coptisine, berberine, and palmatine chloride, the sheathless CE/ ESI-MS sensitivity of a beveled 75 microm tapered tip capillary was found to be similar to a 25 microm flat tip. Although both tips offer similar CE/ESI-MS sensitivity, the beveled tapered capillary tip is more rugged and durable than a conventional 25-microm tapered capillary because of the larger outside diameter and inside diameter. To make electrical contact, the capillary tip was smeared with paint marker followed by the application of a carbon coating using a graphite pencil. Using this refined carbon-coating procedure, the capillary tip can be operated with aprotic solvents.  相似文献   

5.
We describe a method, based on pressure-assisted capillary electrophoresis coupled to electrospray ionization mass spectrometry (PACE/ESI-MS), that allows the simultaneous and quantitative analysis of multivalent anions, such as citrate isomers, nucleotides, nicotinamide-adenine dinucleotides, and flavin adenine dinucleotide, and coenzyme A (CoA) compounds. Key to the analysis was using a noncharged polymer, poly(dimethylsiloxane), coated to the inner surface of the capillary to prevent anionic species from adsorbing onto the capillary wall. It was also necessary to drive a constant liquid flow toward the MS by applying air pressure to the inlet capillary during electrophoresis to maintain a conductive liquid junction between the capillary and the electrospray needle. Although theoretical plates were inferior to those obtained by CE/ESI-MS using a cationic polymer-coated capillary, the PACE/ESI-MS method improved reproducibility and sensitivity of these anions. Eighteen anions were separated by PACE and selectively detected by a quadrupole mass spectrometer with a sheath-flow electrospray ionization interface. The relative standard deviations (n = 6) of the method were better than 0.6% for migration times and between 1.4% and 6.2% for peak areas. The detection limits for these species were between 0.4 and 3.7 micromol/L with pressure injection of 50 mbar for 30 s (30 nL), that is, mass detection limits calculated in the range from 12 to 110 fmol at a signal-to-noise ratio of 3. The utility of the method was demonstrated by analysis of citrate isomers, nucleotides, dinucleotides, and CoA compounds extracted from Bacillus subtilis cells.  相似文献   

6.
Wu YT  Chen YC 《Analytical chemistry》2005,77(7):2071-2077
It has always been assumed that electrical contact at the capillary outlet is a necessary requirement when coupling capillary electrophoresis (CE) with electrospray ionization mass spectrometry (ESI-MS). In this study, we used a pulled bare-capillary tip as the ESI emitter, but neither was it coated with any electrically conductive materials nor was a high external voltage applied on its outlet. In this paper, we demonstrate that this straightforward approach may be used to generate multiply charged ions of proteins and peptides through electrospray ionization. Our results indicate that peptides and proteins, including bradykinin, cytochrome c, myoglobin, and tryptic digest products that elute from a pulled bare-capillary tip can be detected directly by ESI-MS using the tapered bare-capillary interface. Thus, we have demonstrated that CE and ESI-MS may be combined successfully without the need to modify the outlet of the capillary tip with an electrically contacting material.  相似文献   

7.
A capillary electrophoresis/electrospray ionization mass spectrometry (CE/ESI-MS) interface, based on an electric circuit across a microdialysis membrane surrounding a short capillary segment closely connected to the separation capillary terminus, is demonstrated to be sensitive, efficient, and rugged. A microspray type ionization emitter produces a stable electrospray at the low flow rates provided by CE and thus avoids both the need for a makeup liquid flow provided by liquid junction or sheath flow interfaces and the subsequent dilution and reduction in sensitivity. Reproducibility studies and comparisons with CE/UV and the CE/sheath flow interface with ESI-MS are presented. Additionally, postrun acidification via the microdialysis junction interface is demonstrated and shown to be capable of denaturing the holomyoglobin protein noncovalent complex while maintaining separation efficiency.  相似文献   

8.
A capillary electrophoresis mass spectrometry (CE-MS) interface utilizing a flow-through microvial is used to ensure the electric continuity and supply the catholyte and mobilizer solutions during the capillary isoelectric focusing (cIEF) and mobilization process. The flow-through microvial provides a stable chemical environment and helps to improve the ionization efficiency without significantly diluting the analyte. The CE-MS interface facilitates the transfer of the mobilized cIEF effluent to the site of electrospray ionization, and the gaseous ions can be detected directly by a mass spectrometer. It also allows for complete focusing and mobilization processes to be performed automatically in programmed sequences with commercial CE systems. Two different strategies, using either a part of the capillary or the flow-through microvial of the CE-MS interface as the catholyte reservoir for bare fused silica capillaries or neutral coated capillaries, respectively, were developed for automated cIEF-electrospray ionization (ESI)-MS. Reasonable separation efficiency was achieved using proper concentration of carrier ampholytes and suitable strategies of electroosmotic/electrophoretic mobilization.  相似文献   

9.
A microfabricated device has been developed in which electrospray ionization is performed directly from the corner of a rectangular glass microchip. The device allows highly efficient electrokinetically driven separations to be coupled directly to a mass spectrometer (MS) without the use of external pressure sources or the insertion of capillary spray tips. An electrokinetic-based hydraulic pump is integrated on the chip that directs eluting materials to the monolithically integrated spray tip. A positively charged surface coating, PolyE-323, is used to prevent surface interactions with peptides and proteins and to reverse the electroosmotic flow in the separation channel. The device has been used to perform microchip CE-MS analysis of peptides and proteins with efficiencies over 200,000 theoretical plates (1,000,000 plates/m). The sensitivity and stability of the microfabricated ESI source were found to be comparable to that of commercial pulled fused-silica capillary nanospray sources.  相似文献   

10.
A simple procedure was developed for preparing a carbon-coated fused-silica capillary for use in sheathless capillary electrophoresis/electrospray mass spectrometry (CE/ESI-MS). The tapered capillary tip was smeared with a marker pen before coating with carbon using a soft pencil. The layer from the ink of the marker pen was critical to the preparation of the carbon-coated capillary. The fabrication of a carbon-coated fused-silica capillary tip requires less than 1 min. The stability of this carbon-coated fused-silica capillary is examined, and its utility in on-line sheathless CE/ESI-MS is demonstrated with the separation of berberine, coptisine, and palmatine chlorides. Although the carbon-coated fused-silica capillary tip is not as rugged as a gold-coated capillary, it is durable enough for sheathless CE/ESI-MS applications. Moreover, it is easy to refurbish the column once the performance of the tip is degraded.  相似文献   

11.
A colloidal graphite-coated emitter is introduced for sheathless capillary electrophoresis/nanoelectrospray ionization time-of-flight mass spectrometry (CE/ESI-TOFMS). The conductive coating can be produced by brushing the capillary tip to construct a fine layer of 2-propanol-based colloidal graphite. The fabrication involves a single step and requires less than 2 min. Full cure properties develop in approximately 2 h at room temperature and then the tip is ready for use. The coated capillary tip is applied as a sheathless electrospray emitter. The emitter has proven to bear stable electrospray and excellent performance for 50 microm i.d. x 360 microm o.d. and 20 microm i.d. x 360 microm o.d. capillaries within the flow rate of 80-500 nL/min; continuous electrospray can last for over 200 h in positive mode. Baseline separation and structure elucidation of two clinically interesting basic drugs, risperidone and 9-hydroxyrisperidone, are achieved by coupling pressure-assisted CE to ESI-TOFMS using the described sheathless electrospray emitter with a bare fused-silica capillary at pH 6.7. It is found that the signal intensity of m/z in sheathless CE/ESI-TOFMS at pH 6.7 is approximately 50 times higher than that at pH 9.0 for the two analytes, although the electroosmotic flow (EOF) at pH 9.0 provides sufficient flow rate (approximately 150 nL/min) to maintain electrospray.  相似文献   

12.
G Xue  H M Pang  E S Yeung 《Analytical chemistry》1999,71(14):2642-2649
Although liquid chromatography and gas chromatography are the main workhorses in the analytical laboratory, samples can only be analyzed consecutively in an instrument. In this study, capillary zone electrophoresis and micellar electrokinetic chromatography separations are performed in a 96-capillary array system with laser-induced fluorescence detection. Migration times of four kinds of fluoresceins and six polyaromatic hydrocarbons (PAHs) are normalized to one of the capillaries using two internal standards. The relative standard deviations after normalization are 0.6-1.4% for the fluoresceins and 0.1-1.5% for the PAHs. Quantitative calibration of the separations based on peak areas is also performed, again with substantial improvement over the raw data. This opens up the possibility of performing massively parallel separations for high-throughput chemical analysis for process monitoring, combinatorial synthesis, and clinical diagnosis.  相似文献   

13.
Capillary electrophoresis/electrospray ionization-mass spectrometry (CE/ESI-MS) was applied to the analysis of underivatized amino acids and the separation of their D/L-enantiomers. Under full-scan mode, all standard protein amino acids were separated and detected at low-femtomole levels using a 130-cm-long, 20-microm-i.d., 150-microm-o.d. underivatized fused-silica capillary with 1 M formic acid as the background electrolyte. The CE/ESI-MS technique was also applied to the separation of L-arginine from L-canavanine (a close analogue of arginine where the terminal methylene linked to the guanidine group of arginine is replaced by an oxygen atom) in a complex mixture containing all standard protein amino acids. The utility of CE/ESI-MS in the analysis of real-world samples was demonstrated by the identification of two metabolic diseases (PKU and tyrosinemia) through blood analysis with minimal sample preparation. In addition, the on-line separation of 11 underivatized L-amino acids from their D-enantiomers was achieved by using a 30 mM solution of (+)-(18-crown-6)-2,3,11,12-tetracarboxylic acid as the background electrolyte.  相似文献   

14.
15.
Application of C18 monolithic silica capillary columns in HPLC coupled to ion trap mass spectrometry detection was studied for probing the metabolome of the model plant Arabidopsis thaliana. It could be shown that the use of a long capillary column is an easy and effective approach to reduce ionization suppression by enhanced chromatographic resolution. Several hundred peaks could be detected using a 90-cm capillary column for LC separation and a noise reduction and automatic peak alignment software, which outperformed manual inspection or commercially available mass spectral deconvolution software.  相似文献   

16.
A method for simultaneous determination of anionic metabolites based on capillary electrophoresis (CE) coupled to electrospray ionization mass spectrometry is described. To prevent current drop by the system, electroosmotic flow (EOF) reversal by using a cationic polymer-coated capillary was indispensable. A mixture containing 32 standards including carboxylic acids, phosphorylated carboxylic acids, phosphorylated saccharides, nucleotides, and nicotinamide and flavin adenine coenzymes of glycolysis and the tricarboxylic acid cycle pathways were separated by CE and selectively detected by a quadrupole mass spectrometer with a sheath-flow electrospray ionization interface. Key to the analysis was EOF reversal using a cationic polymer-coated capillary and an electrolyte system consisting of 50 mM ammonium acetate, pH 9.0. The relative standard deviations of the method were better than 0.4% for migration times and between 0.9% and 5.4% for peak areas. The concentration detection limits for these metabolites were between 0.3 and 6.7 micromol/L with pressure injection of 50 mbar for 30 s (30 nL); i.e., mass detection limits ranged from 9 to 200 fmol, at a signal-to-noise ratio of 3. This method was applied to the comprehensive analysis of metabolic intermediates extracted from Bacillus subtilis, and 27 anionic metabolites could be directly detected and quantified.  相似文献   

17.
Desorption electrospray ionization (DESI) was demonstrated as a means to couple thin-layer chromatography (TLC) with mass spectrometry. The experimental setup and its optimization are described. Development lanes were scanned by moving the TLC plate under computer control while directing the stationary DESI emitter charged droplet plume at the TLC plate surface. Mass spectral data were recorded in either selected reaction monitoring mode or in full scan ion trap mode using a hybrid triple quadrupole linear ion trap mass spectrometer. Fundamentals and practical applications of the technique were demonstrated in positive ion mode using selected reaction monitoring detection of rhodamine dyes separated on hydrophobic reversed-phase C8 plates and reversed-phase C2 plates, in negative ion full scan mode using a selection of FD&C dyes separated on a wettable reversed-phase C18 plate, and in positive ion full scan mode using a mixture of aspirin, acetaminophen, and caffeine from an over-the-counter pain medication separated on a normal-phase silica gel plate.  相似文献   

18.
An interface in elastomeric poly(dimethylsiloxane) (PDMS) for on-line orthogonal coupling of packed capillary liquid chromatography (LC) (i.d. = 0.2 mm) with capillary electrophoresis (CE) in combination with sheathless electrospray ionization (ESI) time-of-flight mass spectrometric (TOFMS) detection is presented. The new interface has a two-level design, which in combination with a continuous CE electrolyte flow through the interface provides integrity of the LC effluent and the CE separation until an injection is desired. The transparent and flexible PDMS material was found to have a number of advantages when combined with fused silica column technology, including ease to follow the process and ease to exchange columns. By combining conventional microscale systems of LC, CE, and ESI-MS, respectively, the time scales of the individual dimensions were harmonized for optimal peak capacity per unit time. The performance of the LC-CE-TOFMS system was evaluated using peptides as model substances. A S/N of about 330 was achieved for leucine-enkephaline from a 0.5 microL LC injection of 25 microg/mL peptide standard.  相似文献   

19.
Electron paramagnetic resonance (EPR) spectrometry and mass spectrometry (MS) have been coupled together on-line with liquid chromatography (LC)/UV detection. These combined techniques have been applied to the determination of spin-trapped radical adducts, including phenyl, 2-, 3-, and 4-chlorophenyl, and 2-bromophenyl radicals trapped with alpha-(1-oxo-4-pyridyl)-N-tert-butylnitrone (4-POBN), and phenyl radicals trapped with 2-methyl-2-nitrosopropane (MNP), alpha-phenyl-N-tert-butylnitrone (PBN), and 5,5-dimethyl-1-pyrroline N-oxide (DMPO). Oxidized and reduced forms of the radical adducts were also detected by the on-line LC/EPR/MS system.  相似文献   

20.
The interaction of proteins with polysaccharides represents a major and challenging topic in glycobiology, since such complexes mediate fundamental biological mechanisms. A new strategy based on the hyphenation of frontal analysis capillary electrophoresis (FACE) with electrospray ionization mass spectrometry (ESIMS) is reported for the characterization of protein/carbohydrate complexes. While most of the previously reported CE-MS experiments were performed using capillary electrophoresis in zone format, we report for the first time CE-MS experiments in which CE was performed in frontal analysis (FACE-MS). We showed that the frontal mode offered a better sensitivity than zone mode and was well suited for the CE-MS coupling. This FACE-MS coupling was applied to the analysis of the complex between antithrombin and the sulfated pentasaccharide reproducing the antithrombin-binding sequence in heparin. The mixture of coincubated antithrombin and heparin pentasaccharide was continuously injected into the capillary, and the electrophoretic separation of the free and bound forms of the protein was achieved. The intact noncovalent complex antithrombin/heparin pentasaccharide was detected on-line by ESIMS in positive ionization mode and in nondenaturing sheath liquid conditions. The complex stoichiometry was determined from the mass measurement of the complex. In addition, the characterization of the sulfated pentasaccharide ligand dissociated from the complex was performed in negative ionization mode using a denaturing sheath liquid, allowing the determination of its molecular mass and sulfation features. This FACE-ESIMS strategy opens the way to ligand fishing experiments performed on heterogeneous carbohydrate mixtures and subsequent characterization of specifically bound carbohydrates.  相似文献   