首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Two in situ plane-strain deformation experiments on norcamphor and natural ice using synchronous recording of crystal c-axis orientations have been performed with an automated fabric analyser and a newly developed sample press and deformation stage. Without interrupting the deformation experiment, c-axis orientations are determined for each pixel in a 5 × 5 mm sample area at a spatial resolution of 5 μm/pixel. In the case of norcamphor, changes in microstructures and associated crystallographic information, at a strain rate of ~2 × 10(-5) s(-1), were recorded for the first time during a complete in situ deformation-cycle experiment that consisted of an annealing, deformation and post-deformation annealing path. In the case of natural ice, slower external strain rates (~1 × 10(-6) s(-1)) enabled the investigation of small changes in the polycrystal aggregate's crystallography and microstructure for small amounts of strain. The technical setup and first results from the experiments are presented.  相似文献   

2.
A unique high-load, high-temperature uniaxial press was developed to measure the rheology of silicate melts and magmatic suspensions at temperature up to 1050 degrees C. This new apparatus is designed to operate at constant stresses (up to 300 kN) or constant strain rates (approximately 10(-7) to 10(0) s(-1)) and further allows us to carry on experiments on samples with high viscosities (approximately 10(8) to 10(12) Pa s). The rheological instrument represents an advance in that it accommodates homogeneously heated samples (+/-2 degrees C) of voluminous sizes (up to 790 cm(3)) which permit the insertion of thermocouples to monitor temperature distribution evolutions during measurements. At last this setup allows for accurate measurements of viscosity of natural multiphase materials at strain rates and temperatures common to natural systems. The apparatus aspires to precisely (1) describe the onset of non-Newtonian behavior and its evolution with increasing strain rate until the point of rupture in the brittle regime, (2) constrain the effect of crystals and bubbles on the viscosity, and (3) record heating dissipated through viscous deformation. Here, we present a series of measurements on NIST standard material SRM 717a to calibrate the instrument. We couple the viscosity determined via Gent's equation with certified viscosity data of the standard material to calibrate this state-of-the-art apparatus. This work shows that we can resolve the viscosity of voluminous melt sample within 0.06 logarithmic unit and furthermore present the detection of minor viscous dissipation for a high-temperature, high strain rate experiment.  相似文献   

3.
Steel specimens of type 1023 and heat treated 4130 steel of hardnesses, between 257 and 450 HV10, were compressed at strain rates between 3 × 103 and 3 × 104 s−1 using a modified Hopkinson bar. Both steels showed viscous type flow behaviour with a linear increase in flow stress with strain rate. For the 1023 steel there were two linear regions, one from 3 to 12 × 103 s−1 with a macroscopic viscosity of 4·7 kPa s and two from 14 to 27 × 103 s−1 with a viscosity of 0·7 kPa s. These results indicate some change in the controlling mechanism. For the 4130 steel the macroscopic viscosity decreased linearly with increasing hardness from 7·4 kPa s at 257 HV 10 to 2·2 kPa s at 450 HV 10. This was probably due to a decrease in the density of mobile dislocations with increased tempering temperatures. At lower hardness values (257 and 300 HV 10) and higher strain rates, a levelling off of the flow stress occurred but the data were too scattered to give a definite trend. The heat generated due to deformation of the 1023 steel was sufficient to produce steady state flow at strains above about 0·3. In the 4130 steel the thermo-mechanical properties were such that linear work softening was observed at a rate inversely proportional to the square root of the strain rate and independent of the hardness. This suggests that the work softening was a function of properties of the common ferrite matrix. The strain at which the work softening commenced decreased with increasing hardness, because of the more rapid heat generation at higher flow stresses. At higher hardness and higher strain rates 4130 steel failed by shear. Shear failure occurred at lower strain rates with increasing hardness and, for a given hardness, at lower strains with increasing strain rate. This behaviour was consistent with Recht's analysis of catastrophic shear failure.  相似文献   

4.
在不同温度环境下,利用MTS材料试验机,在中等应变速率(1/s)下,对玻璃布-环氧层板的动态力学性能进行了实验研究,获得了杨氏模量、拉伸强度和泊松比等力学参数;对该层板材料在不同温度、不同应变速率下的应力应变曲线和破坏过程进行了分析讨论。根据实验数据,拟合了玻璃布-环氧层板材料的本构关系  相似文献   

5.
In this paper, we demonstrate that the shift between similar features in two electron backscatter diffraction (EBSD) patterns can be measured using cross-correlation based methods to +/- 0.05 pixels. For a scintillator screen positioned to capture the usual large solid angle employed in EBSD orientation mapping this shift corresponds to only approximately 8.5 x 10(-5)rad at the pattern centre. For wide-angled EBSD patterns, the variation in the entire strain and rotation tensor can be determined from single patterns. Repeated measurements of small rotations applied to a single-crystal sample, determined using the shifts at four widely separated parts of the EBSD patterns, showed a standard deviation of 1.3 x 10(-4) averaged over components of the displacement gradient tensor. Variations in strains and rotations were measured across the interface in a cross-sectioned Si1-x Gex epilayer on a Si substrate. Expansion of the epilayer close to the section surface is accommodated by tensile strains and lattice curvature that extend a considerable distance into the substrate. Smaller and more localised shear strains are observed close to the substrate-layer interface. EBSD provides an impressive and unique combination of high strain sensitivity, high spatial resolution and ease of use.  相似文献   

6.
An optoelectronic target-type volumetric air flow-rate transducer for bidirectional measurements is presented. The sensor is composed of a T-shaped target and two nominally identical LED-photodiode couples which are operated in differential mode. The sensitive surfaces of the photodiodes are differentially shadowed by the deflection of the target, which in turn depends on the gas flow-rate. The principle of operation is described in mathematical terms and the design parameters have been optimized in order to obtain the highest sensitivity along with minimal pressure drop and reduced dimensions. The sensor is placed in a 20 mm diameter hose and was tested with air flow-rate in the typical temperature range of mechanical ventilation between 20 and 40 °C. The theoretical model was validated through experiments carried out in the volumetric flow range from -7.0 to +7.0 l min(-1). The nonlinear behavior allows sensitivities equal to 0.6 V l(-1) min for flow rates ranging from -2.0 to +2.0 l min(-1), equal to 2.0 V l(-1) min for flow rates ranging from -3.0 to -2.0 l min(-1) and from +2.0 to +3.0 l min(-1), up to 5.7 V l(-1) min at higher flow rates ranging from -7.0 to -3.0 l min(-1) and from +3.0 to +7.0 l min(-1). The linear range extends from 3.0 to 7.0 l min(-1) with constant sensitivity equal to 5.7 V l(-1) min. The sensor is able to detect a flow-rate equal to 1.0 l min(-1) with a sensitivity of about 400 mV l(-1) min. The differential nature of the output minimizes the influence of the LEDs' power supply variations and allows to obtain a repeatability in the order of 3% of full scale output. The small pressure drop produced by the sensor placed in-line the fluid stream, of about 2.4 Pa at 7 l min(-1), corresponds to a negligible fluid dynamic resistance lower than 0.34 Pa l(-1) min.  相似文献   

7.
采用INSTRON准静态压缩实验机和分离式霍普金森压杆装置对铸造固溶态AM80镁合金不同应变速率下的压缩变形行为进行了研究,应变速率分别为0.0001s-1、800s-1、1050s-1、1600s-1、1850s-1和2100s-1。结果表明:当应变速率ε˙≤1850s-1时,实验用AM80镁合金的流变应力随应变速率的增大而增大,表现出明显的正应变速率敏感性;当应变速率增至2100s-1时,由于局部温升效应,合金产生了明显的动态软化,导致流变应力反而略有减小。采用Johnson-Cook材料模型对实验用AM80镁合金在不同应变速率下的变形行为进行描述,并取材料应变速率强化参数为应变速率的函数。对比结果表明,所建立的本构方程与实验结果基本吻合。此外,由于力学本构忽略了由形变引起的温升软化,基于ABAQUS的仿真结果在较低应变速率(800s-1)和高应变速率(1850s-1)的中低应变下与实验结果吻合得较好;而在高应变速率(1850s-1)的较高应变条件下,仿真结果与实验结果差异较大。  相似文献   

8.
Bone tissue functions in varied mechanical systems of the body under static and dynamic conditions. Therefore, it is essential to understand the mechanical responses of bone at varied loading rates, especially those at fast loading rates. This study has investigated the effect of loading rate on the compressive mechanical properties of bovine cortical bone. Bone specimens of 3.85 mm in diameter and 7.7 mm in length were compressed longitudinally with the loading rates of 2 to 2000 mm/s (corresponding strain rates of 0.26 to 260 s(-1)). As a result, bovine cortical bone showed high linear elasticity when the loading rate was slow, and exhibited three definite regions of linear elasticity, plastic deformation, and densification at faster loading rates. The elastic modulus showed no dependency on the loading rate. Compressive strength, strain at fracture, and toughness increased as the loading rate increased under the condition that the loading rates were slower than each critical loading rate of 1000, 100, and 1500 mm/s, respectively. However, all showed no significant changes when the loading rates were faster than the corresponding critical loading rates. In conclusion, as the loading rate increased, changes in the compressive mechanical parameters were different depending on the parameter and the loading rate range. Compressive mechanical behaviour of bovine cortical bone showed a brittle nature under high strain rates (strain rates > 13 s(-1)). These findings should be reflected in the biomimetic simulation of biomaterials for bone tissue repair and engineering.  相似文献   

9.
A method is described for measuring the mechanical properties of polymers in compression at strain rates in the range approximately 300–500 s−1. A gravity-driven pendulum is used to load a specimen on the end of an instrumented Hopkinson output bar and the results are processed by a microcomputer. Stress-strain curves up to high strains are presented for polycarbonate, polyethersulphone and high density polyethylene over a range of temperatures. The value of yield stress, for all three polymers, was found to vary linearly with log (strain rate) at strain rates up to 500 s−1.  相似文献   

10.
We report an experimental method to study the anelastic properties of materials at high pressure and high temperature. The multianvil high pressure deformation device, used to apply a cyclic loading force onto the sample, can reach 15 GPa and 2000 K. A synchrotron x-ray radiation source provides time resolved images of the sample and reference material. The images yield stress and strain as a function of time; stresses are derived from the reference material, and strains from the sample. This method has been tested by applying a sinusoidal stress at megahertz to hertz frequency on a San Carlos olivine specimen at 5 GPa and up to 2000 K. Strain as small as 10(-5) can be resolved. We have obtained experimental results which exhibit resolvable attenuation factor (Q(-1)) and shear modulus (M) at deep Earth conditions. These results are in quantitative agreement with previously reported lower pressure data and suggest that temperature and grain size have dominating effect on these properties.  相似文献   

11.
高应变率下Cu-P/M摩擦材料正向和反向应变率效应   总被引:1,自引:1,他引:0  
研究了冲击载荷下铜基粉末冶金(Cu P/M)摩擦材料不同的应变率效应。试验在分离式Hopkinson压杆 (SHPB)上完成。应变率范围为:102/s~103/s。通过试验得到了该材料的动态应力应变曲线,发现该材料在应变率 1000/s以下,表现为应变率强化效应;在应变率1000/s以上,表现为应变率弱化效应。也就是说,应变率1000/s是 该材料的临界应变率。为了与静态时的情况比较,在MTS试验机上又做了10-4/s~10-3/s应变率范围内的准静态 实验。比较动静态试验结果,发现动态时的屈服极限大于静态的;而屈服后的应变硬化率是静态大于动态的。通过 对样品进行微观组织分析,发现在压制烧结时有硬质颗粒破碎。在冲击载荷下材料内部的损伤演化形成大范围的 多源裂纹及孔洞分布群导致裂纹迅速扩展,同时伴随硬质颗粒破碎。  相似文献   

12.
High strain rate mechanical testing on fully hardened AISI D2 tool steel (at 62 HRc) was performed utilizing the Compressive Split Hopkinson Bar technique (CSHB) incorporating a punching shear strain state. The high strain rate conditions were comparable to those encountered in machining processes, with shear strain rates on the order of 5 × 104 s-1 and shear strains in excess of unity (100% mm/mm). The tests were performed at various initial temperatures ranging from 296-873 K to investigate the flow stress behavior of the hardened tool steel as a function of temperature. The high strain rate experimental shear stress-strain data was used to fit the flow stress by; i) an empirically based constitutive law in the form proposed by Johnson and Cook; as well as, (ii) a physically based constitutive law proposed by Zerilli and Armstrong which accounts for strain, strain rate, and temperature dependence of flow stress. The data incorporated the adiabatic temperature rise in the shear zone and was used in the constitutive law modeling. The deformed microstructure was investigated using optical and scanning electron microscopy to determine the extent of the shear localization zone and the final fracture mode.  相似文献   

13.
This study examines magnesium alloy AZ31B circular tubing subject to uniaxial compressive loading and compares their performance to steel (ASTM A106 Grade B) and aluminium alloy AA6061T6 circular tubing at both low and high strain rates. Quasi-static tests were undertaken using a hydraulic testing machine for a range of tube lengths and thicknesses for tubes with an outside diameter of approximately 48 mm. To examine the effects of higher strain rate, a drop test rig was used. It was found that magnesium alloy AZ31B outperforms both the steel and aluminium alloys in terms of energy absorption for equivalent mass when subject to uniaxial compressive loads for the thicker sections. This is further enhanced by alloy AZ31B’s strain rate sensitivity, as there is a dramatic increase in the energy absorption at higher strain rates. However, the AZ31B tubes usually fail by fracturing, which generally involves a shear fracture mode, unlike the aluminium and steel tubes, which generally retained their structural integrity to a higher degree. The greatest energy absorption was obtained when the AZ31B failed via fine sharding. This failure mode appeared to be related to the presence of micro-cracks on the surface of the section obtained by overheating during extrusion. At higher strain rates, much greater plasticity and compaction are present in the fracture modes for the thicker AZ31B tubing. Some of the fracture modes have been discussed and the failure/fracture modes are compared with a typical aluminium alloy tube failure mode classification chart.  相似文献   

14.
We have developed a unique device, a dynamic diamond anvil cell (dDAC), which repetitively applies a time-dependent load/pressure profile to a sample. This capability allows studies of the kinetics of phase transitions and metastable phases at compression (strain) rates of up to 500 GPa/s (approximately 0.16 s(-1) for a metal). Our approach adapts electromechanical piezoelectric actuators to a conventional diamond anvil cell design, which enables precise specification and control of a time-dependent applied load/pressure. Existing DAC instrumentation and experimental techniques are easily adapted to the dDAC to measure the properties of a sample under the varying load/pressure conditions. This capability addresses the sparsely studied regime of dynamic phenomena between static research (diamond anvil cells and large volume presses) and dynamic shock-driven experiments (gas guns, explosive, and laser shock). We present an overview of a variety of experimental measurements that can be made with this device.  相似文献   

15.
A system for dispensing and continuously measuring the flow of solid particles into a hot high-pressure gas flow for times up to 1 h is described. A differential pressure across an orifice is used to force the particle flow. A strain gauge load cell is used to continuously sense the weight of the container from which the particles are being dispensed. Calibration results are included for flows of 100-microm-diam glass spheres through several orifices at rates from 1 to 15 g/s.  相似文献   

16.
Silicone elastomers are commonly used in the manufacture of single-piece joint replacement implants for the finger joints. However, the survivorship of these implants can be poor, with failure typically occurring from fracture of the stems. The aim of this paper was to investigate the crack growth of medical-grade silicone using pure shear tests. Two medical-grade silicones (C6-180 and Med82-5010-80) were tested. Each sample had a 20 mm crack introduced and was subjected to a sinusoidally varying tensile strain, with a minimum of 0 per cent and a maximum in the range 10 to 77 per cent. Testing was undertaken at a frequency of 10 Hz. At various times during testing, the testing machine was stopped, the number of cycles completed was noted, and the crack length measured. Graphs of crack length against number of cycles were plotted, as well as the crack growth rate against tearing energy. The results show that Med82-5010-80 is more crack resistant than C6-180. Graphs of crack growth rate against tearing energy can be used to predict the failure of these medical-grade elastomers.  相似文献   

17.
A requirement of many surface science studies is the capability to alter a sample temperature in a controlled mode. Sample preparation procedures such as heating or cooling ramps, high temperature spikes, fast annealing, or simply maintaining a sample at a very high, or very low, temperature are common. To address these issues, we describe the design and the construction of a multipurpose sample holder. Key points of this design are operation in an extended temperature range from liquid nitrogen (LN(2)) temperature to approximately 1300 K, temperature control during heating and cooling, low thermal inertia with rates up to 50 K s(-1) (heating) and -20 K s(-1) (cooling), and small heated volume to minimize background problems in thermal desorption spectroscopy (TDS) spectra. With this design the sample can be flash heated from LN(2) temperature to 1300 K and cooled down again in less than 100 s. This sample holder was mounted and tested in a multitechnique apparatus and adds a large number of sample preparation procedures as well as TDS to the list of already available surface analysis techniques.  相似文献   

18.
A new modelling approach, using a combination of shell and solid elements, has been adopted to develop a realistic three-dimensional finite element (FE) model of the human scapula. Shell elements were used to represent a part of the compact bone layer (i.e. the outer cortical layer) and the very thin and rather flat part of the scapula--infraspinous fossa and supraspinous fossa respectively. Solid elements were used to model the remaining part of the compact bone and the trabecular bone. The FE model results in proper element shapes without distortion. The geometry, material properties and thickness were taken from quantitative computed tomography (CT) data. A thorough experimental set-up for strain gauge measurement on a fresh bone serves as a reference to assess the accuracy of FE predictions. A fresh cadaveric scapula with 18 strain gauges fixed at various locations and orientations was loaded in a mechanical testing machine and supported at three locations by linkage mechanisms interconnected by ball joints. This new experimental set-up was developed to impose bending and deflection of the scapula in all directions unambiguously, in response to applied loads at various locations. The measured strains (experimental) were compared to numerical (FE) strains, corresponding to several load cases, to validate the proposed FE modelling approach. Linear regression analysis was used to assess the accuracy of the results. The percentage error in the regression slope varies between 9 and 23 per cent. It appears, as a whole, that the two variables (measured and calculated strains) strongly depend on each other with a confidence level of more than 95 per cent. Considering the complicated testing procedure on a fresh sample of scapula, the high correlation coefficients (0.89-0.97), the low standard errors (29-105 micro epsilon) and percentage errors in the regression slope, as compared to other studies, strongly suggest that the strains calculated by the FE model can be used as a valid predictor of the actual measured strain. The model is therefore an alternative to a rigorous three-dimensional model based on solid elements only, which might often be too expensive in terms of computing time.  相似文献   

19.
The deleterious consequences of climate change are well documented. Future climate treaties might mandate greenhouse gas (GHG) emissions measurement from signatories in order to verify compliance. The acquisition of atmospheric chemistry would benefit from low cost, small size/weight/power of microsystems. In this paper, we investigated several key materials science aspects of a phase-change microvalve (PCμV) technology with low power/size/weight/cost for ubiquitous GHG sampling. The novel design, based on phase-change material low-melting-point eutectic metal alloys (indium-bismuth, InBi and tin-lead, SnPb), could be actuated at temperatures as low as 72 °C. Valve manufacturing was based on standard thick and thin-film processes and solder technologies that are commonly used in industry, enabling low-cost, high-volume fabrication. Aging studies showed that it was feasible to batch fabricate the PCμVs and store them for future use, especially in the case of SnPb alloys. Hermetic sealing of the valve prototypes was demonstrated through helium leak testing, and Mil spec leak rates less than 1 × 10(-9) atm cm(3)/s were achieved. This confirms that the sample capture and analysis interval can be greatly expanded, easing the logistical burdens of ubiquitous GHG monitoring. Highly conservative and hypothetical CO(2) bias due to valve actuation at altitude in 1 cm(3) microsamplers would be significantly below 1.0 and 2.2 ppmv for heat-treated InBi and SnPb solders, respectively. The CO(2) bias from the PCμV scales well, as a doubling of sampler volume halved the bias. We estimated the shelf life of the SnPb PCμVs to be at least 2.8 years. These efforts will enable the development of low cost, low dead volume, small size/weight microsystems for monitoring GHGs and volatile organic compounds.  相似文献   

20.
A lot of research has been focused on the necking process during the plastic deformation of sheet metals, but the localized necking is rarely distinguished form diffused necking by experiments, due to the limit of measurement equipment and method. Quenching and Partitioning (Q&P) steel is a 3rd generation advanced high strength steel (AHSS). Its good combination of high strength and ductility ensures potential application in automobile industry. Uniaxial tensile tests of QP980 steel sheet at five strain rates are performed to investigate the necking process and the effect of strain rate on necking behavior of Q&P steel. Digital image correlation (DIC) method is applied during tensile tests, and evolutions of major strain, minor strain and normal strain distributions along gauge section of the tensile specimens are obtained. The diffused and localized necking strains are determined according to SWIFT necking theory and HILL necking theory respectively. The test results indicate that with the increasing of strain rate in the investigated range, the diffused necking strain decreases from 0.152 to 0.120 and localized necking strain decreases from 0.245 to 0.137. Meanwhile, the difference of the two strains decreases form 0.096 to 0.017. Thus it can be concluded that strain rate has an influence on both necking strains during the deformation of QP980 steel sheet. Diffused and localized necking strains are determined by uniaxial tensile tests with the aid of DIC technique and the effect of strain rate on necking strains is evaluated.  相似文献   