首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Both experimental and simulated studies of microdischarge (MD) are carried out in a dielectric barrier discharge with a pin-to-pin gap of 3.5 mm, ignited by a sinusoidal voltage with a peak voltage of 10 kV and a driving frequency of 5 kHz. Statistical results have shown that the probability of the single current pulse in the positive half-period (HP) reaches 73.6% under these conditions. Experimental results show that great luminous intensity is concentrated on the dielectric surface and the tip of the metal electrode. A 1D plasma fluid model is implemented by coupling the species continuity equations, electron energy density equations, Poisson equation, and Helmholtz equations to analyze the MD dynamics on the microscale. The simulated results are in good qualitative agreement with the experimental results. The simulated results show that the MD dynamics can be divided into three phases: the Townsend phase, the streamer propagation phase, and the discharge decay phase. During the streamer propagation phase, the electric field and electron density increase with the streamer propagation from the anode to the cathode, and their maximal values reach 625.48 Td and 2.31 × 1019 m−3, as well as 790.13 Td and 3.58 × 1019 m−3 in the positive and negative HP, respectively. Furthermore, a transient glow-like discharge is detected around the anode during the same period of streamer propagation. The formation of transient glow-like discharge is attributed to electrons drifting back to the anode, which is driven by the residual voltage in the air gap.  相似文献   

2.
In this work, a portable floating-electrode dielectric barrier discharge(FE-DBD) device is designed with a rechargeable battery as the power supply. The characteristics of the FE-DBD with a metal electrode and human hand are studied and compared. The human contact safety is verified by calculating the current through the human body based on the equivalent circuit model. Escherichia coli inactivation experiments confirm the efficacy of the FE-DBD device in the envisaged applications.  相似文献   

3.
A comparative study of radio-frequency atmospheric pressure glow discharge(rf APGD)generated in helium with and without dielectric electrodes to investigate the effect of electrodes insulation on electrical features of APGD is presented. In the α mode, both the rf APGDs remain volumetric, stable and uniform. In the γ mode, the APGD without dielectric electrodes shrinks into a constricted plasma column whereas APGD with dielectric electrodes remains stable and retains the same volume without plasma constriction even at higher densities of discharge current. A comparison of electrical features of both rf APGDs in normal and abnormal glow discharge regimes is presented. In both APGDs with and without dielectric electrodes,impedance measurements have been performed and compared with equivalent circuit models.The measured impedance data is found to be in good agreement with simulated data.  相似文献   

4.
A portable skincare plasma-device with a rechargeable battery is presented here. The device comprises two pads made of thin polyimide film as the dielectric layer, namely, the dielectric barrier discharge pad(DBD-pad) for skin-touch and a capacitive ground-pad(G-pad) for hand holding. High AC voltage of approximately 1 kV with frequency of 40 kHz is induced in the DBD-pad that contacts the skin, which serves as the floating electrode, while low voltage is induced on the G-pad. Considering the requirement for impedance matching between the DBDpad capacitance and the inverter along with the need for low skin current less than approximately 5 mA for electrical safety, the electrode area of the DBD-pad is minimized to be smaller than that of the G-pad.  相似文献   

5.
Atmospheric pressure helium/water dielectric barrier discharge(DBD) plasma is used to investigate the generation of reactive species in a gas–liquid interface and in a liquid. The emission intensity of the reactive species is measured by optical emission spectroscopy(OES)with different discharge powers at the gas–liquid interface. Spectrophotometry is used to analyze the reactive species induced by the plasma in the liquid. The concentration of OH radicals reaches 2.2 μm after 3 min of discharge treatment. In addition, the concentration of primary longlived reactive species such as H_2O_2, NO_3~- and O_3 are measured based on plasma treatment time.After 5 min of discharge treatment, the concentration of H_2O_2, NO_3~-, and O_3 increased from 0 mg?·?L~(-1) to 96 mg?·?L~(-1), 19.5 mg?·?L~(-1), and 3.5 mg?·?L~(-1), respectively. The water treated by plasma still contained a considerable concentration of reactive species after 6 h of storage. The results will contribute to optimizing the DBD plasma system for biological decontamination.  相似文献   

6.
A coaxial dielectric barrier discharge(DBD) reactor with double layer dielectric barriers has been developed for exhaust gas treatment and excited either by AC power or nanosecond(ns)pulse to generate atmospheric pressure plasma. The comparative study on the discharge characteristics of the discharge uniformity, power deposition, energy efficiency, and operation temperature between AC and ns pulsed coaxial DBD is carried out in terms of optical and electrical characteristics and operation temperature for optimizing the coaxial DBD reactor performance. The voltages across the air gap and dielectric layer and the conduction and displacement currents are extracted from the applied voltages and measured currents of AC and ns pulsed coaxial DBDs for the calculation of the power depositions and energy efficiencies through an equivalent electrical model. The discharge uniformity and operating temperature of the coaxial DBD reactor are monitored and analyzed by optical images and infrared camera. A heat conduction model is used to calculate the temperature of the internal quartz tube. It is found that the ns pulsed coaxial DBD has a much higher instantaneous power deposition in plasma, a lower total power consumption, and a higher energy efficiency compared with that excited by AC power and is more homogeneous and stable. The temperature of the outside wall of the AC and ns pulse excited coaxial DBD reaches 158 ℃ and 64.3 ℃ after 900 s operation, respectively.The experimental results on the comparison of the discharge characteristics of coaxial DBDs excited by different powers are significant for understanding of the mechanism of DBDs,reducing energy loss, and optimizing the performance of coaxial DBD in industrial applications.  相似文献   

7.
We demonstrate a method to generate tunable triangular and honeycomb plasma structures via dielectric barrier discharge with uniquely designed mesh-liquid electrodes. A rapid reconfiguration between the triangular lattice and honeycomb lattice has been realized. Novel structures comprised of triangular plasma elements have been observed and a robust angular reorientation of the triangular plasma elements withis suggested. An active control on the geometrical shape, size and angular orientation of the plasma elements has been achieved. Moreover, the formation mechanism of different plasma structures is studied by spatial-temporal resolved measurements using a high-speed camera. The photonic band diagrams of the plasma structures are calculated by use of finite element method and two large omnidirectional band gaps have been obtained for honeycomb lattices, demonstrating that such plasma structures can be potentially used as plasma photonic crystals to manipulate the propagation of microwaves. The results may offer new strategies for engineering the band gaps and provide enlightenments on designing new types of 2D and possibly 3D metamaterials in other fields.  相似文献   

8.
In this work, an Ar plasma jet generated by an AC-microsecond-pulse-driven dielectric barrier discharge reactor, which had two ring-shaped electrodes isolated from the ambient atmosphere by transformer oil, was investigated. By special design of the oil insulation, a chemically active Ar plasma jet along with a safe and stable plasma process as well as low emission of CO and NOx were successfully achieved. The results indicated that applied voltage and frequency were basic factors influencing the jet temperature, discharge power, and jet length, which increased significantly with the two operating parameters. Meanwhile, gas velocity affected the jet temperature in a reverse direction. In comparison with a He plasma jet, the Ar plasma jet had relatively low jet temperature under the same level of the input parameters, being preferable for bio-applications. The Ar plasma jet has been tested to interact with human skin within 5 min without the perception of burnt skin and electrical shock.  相似文献   

9.
In this paper, a two-dimensional axisymmetric fluid model was established to investigate the influence of nitrogen impurity content on the discharge pattern and the relevant discharge characteristics in an atmosphere pressure helium dielectric barrier discharge (DBD). The results indicated that when the nitrogen content was increased from 1 to 100 ppm, the discharge pattern evolved from a concentric-ring pattern into a uniform pattern, and then returned to the concentricring pattern. In this process, the discharge mode at the current peak moment transformed from glow mode into Townsend mode, and then returned to glow mode. Further analyses revealed that with the increase of impurity level, the rate of Penning ionization at the pre-ionization stage increased at first and decreased afterwards, resulting in a similar evolution pattern of seed electron level. This evolution trend was believed to be resulted from the competition between the N2 partial pressure and the consumption rate of metastable species. Moreover, the discharge uniformity was found positively correlated with the spatial uniformity of seed electron density as well as the seed electron level. The reason for this correlation was explained by the reduction of radial electric field strength and the promotion of seed electron uniformity as pre-ionization level increases. The results obtained in this work may help better understand the pattern formation mechanism of atmospheric helium DBD under the variation of N2 impurity level, thereby providing a possible means of regulating the discharge performance in practical application scenarios.  相似文献   

10.
Recently, packed-bed discharge plasma technologies have been widely studied for treatment of volatile organic compounds (VOCs), due to the good performance in improving the degradation and mineralization of VOCs. In this paper, a coaxial cylindrical dielectric barrier discharge reactor packed with porous material of micron-sized pores was used for degradation of benzene, and the discharge characteristics and ozone generation characteristics were studied. When the discharge length was 12 cm and the filling length was 5 cm, the packed particles in the discharge area significantly increased the number of micro-discharges, and the current amplitude and density increased with the pore size of packed particles, but the discharge power and ozone concentration showed a trend of first increasing and then decreasing. The discharge power and ozone production reached the maximum when the size of pore former was 75 μm, correspondingly, the degradation efficiency of benzene was the highest.  相似文献   

11.
In this study, we computationally examined the dynamics of dielectric barrier discharge in hydrogen sulfide. The simulations were performed with a 1d3v particle-in-cell/Monte Carlo collision model in which a parallel-plate electrode geometry with dielectrics was used. Particle recombination process is represented in the model. The discharge mode was found to be initially Townsend discharge developing from the cathode to the anode, and at the peak of the current, a more stable glow discharge develops from the anode to the cathode. A higher applied voltage results in sufficient secondary electrons to trigger a second current peak, and then the current amplitude increases. As the frequency is increased, it leads to the advance of the phase and an increase in the amplitude of the current peak. A higher dielectric permittivity also makes the discharge occur earlier and more violently in the gap.  相似文献   

12.
In this work, a single Al2O3 particle packed dielectric barrier discharge (DBD) reactor with adjustable discharge gap is built, and the influences of the particle shape (ball and column) and the residual gap between the top electrode and particle on the electrical and optical characteristics of plasma are studied. Our research confirms that streamer discharge and surface discharge are the two main discharge patterns in the single-particle packed DBD reactor. The strong electric field distortion at the top of the ball or column caused by the dielectric polarization effect is an important reason for the formation of streamer discharge. The length of streamer discharge is proportional to the size of the residual gap, but the number of discharge times of a single voltage cycle shows an opposite trend. Compared to the column, a smooth spherical surface is more conducive to the formation of large and uniform surface discharges. The surface discharge area and the discharge intensity reach a maximum when the gap is equal to the diameter of the ball. All in all, the results of this study will provide important theoretical support for the establishment of the synergistic characteristics of discharge and catalysis in plasma catalysis.  相似文献   

13.
To compensate for the shortcomings of the thermal and catalytic regeneration of the diesel particulate filter(DPF),a self-designed packed-bed dielectric barrier discharge(DBD)reactor for DPF regeneration was developed.The DBD reactor with the main active substance of nonthermal plasma(NTP)as the target parameter was optimized by adjusting the feed gas,packing particles(material or size),and cooling water temperature.Moreover,a set of optimal working parameters(gas source,O2;packing particles,1.2-1.4 mm ZrO2;and cooling water temperature,20℃)was selected to evaluate the effect of different O3 concentrations on DPF regeneration.The research results showed that selecting packing particles with high dielectric constant and large particles,as well as reducing the cooling water temperature,with oxygen as the feed gas,contributed to an increase in O3 concentration.During DPF regeneration,the following changes were observed:the power of the NTP reactor decreased to lower than 100 W,the O3 concentration increased from 15 g m-3 to 45 g m-3,the CO and CO2 volume fractions of the particulate matter decomposition products increased,and the peak regeneration temperature increased to 173.4℃.The peak temperature arrival time was 60 min earlier,indicating that the regeneration rate of DPF increased with the increase in O3 concentration.However,the O3 utilization rate(the amount of carbon deposit removed per unit volume O3)initially increased and then decreased;when the O3 concentration was set to 25 g m-3,the highest O3 utilization rate was reached.The packed-bed DBD technology contributed to the increase in the concentration of NTP active substances and the regeneration efficiency of DPF.It provides a theoretical and experimental basis for high-efficiency regeneration of DPF at low temperatures(<200℃).  相似文献   

14.
The dielectric barrier discharge(DBD) in air at atmospheric pressure is not suitable for industrial applications due to its randomly distributed discharge filaments. In this paper, the influence of the electric field distribution on the uniformity of DBD is theoretically analyzed and experimentally verified. It is found that a certain degree of uneven electric field distributions can control the development of electron avalanches and regulate their transition to streamers in the gap. The discharge phenomena and electrical characteristics prove that an enhanced Townsend discharge can be formed in atmospheric-pressure air with a curved-plate electrode. The spectral analysis further confirms that the gas temperature of the plasma produced by the curved-plate electrode is close to room temperature, which is beneficial for industrial applications. This paper presents the relationship between the electron avalanche transition and the formation of a uniform DBD, which can provide some references for the development and applications of the DBD in the future.  相似文献   

15.
Energy efficiency limits the application of atmospheric pressure dielectric barrier discharge(DBD),such as air purification,water treatment and material surface modification.This article focuses on the electrical and optical effects of the DBD under three square wave pulses polarities-positive,negative and bipolar.The result shows that under the same voltage with the quartz glass medium,the discharge efficiency of bipolar polarity pulse is the highest due to the influence of deposited charge.With the increase of air gap distance from 0.5 to 1.5 mm,average power consumed by the discharge air gap and discharge efficiency decrease obviously under alumina,and increase,and then decrease under quartz glass and polymethyl methacrylate(PMMA).Through spectrum diagnosis,in the quartz glass medium,the vibration temperature is the highest under negative polarity pulse excitation.Under bipolar pulse,the vibration temperature does not change significantly with the change of air gap distance.For the three dielectric materials of quartz glass,alumina and PMMA,the molecular vibration temperature is the highest under the quartz glass medium with the same voltage.When the gap spacing,pulse polarity or dielectric material are changed,the rotational temperature does not change significantly.  相似文献   

16.
The influences of frequency on nitrogen fixation of dielectric barrier discharge in air were studied by electrical diagnostics, gas detection and infrared detection methods. The system power, nitrogen oxide concentration, voltage–current waveform, dielectric surface temperature distribution and filamentous discharge pictures were measured, and then the energy yield was calculated; paper studied their changing tendencies in the presence of frequency. Results show that frequency has strong influences on nitrogen fixation. When the parameters of reaction chamber and amplitude of applied voltage is fixed, with the increasing of frequency, the system power increases; in 5-10 kHz, nitrogen oxide gas concentration up to 1113.7 mg m~(-3), and 7 k Hz is the optimal nitrogen fixation frequency whose energy yield is 20.5 mg(m~3 W)~(-1).  相似文献   

17.
The effects of nitrogen on ozone synthesis are studied in a coaxial cylinder generator with dielectric barrier discharge (DBD) and pack-bed dielectric barrier discharge (PB-DBD). A series of 10 h discharge experiments are conducted adopting a bare stainless electrode and bare copper electrode. Results show that the material of the electrode can affect the ozone synthesis. It is inferred that the ozone zero phenomenon (OZP) may be induced from ozone decomposing by metallic oxide catalysis. Packing dielectric particles can reduce the OZP. Adding a certain amount of nitrogen into the oxygen feed gas can further eliminate the OZP, and increase the ozone concentration significantly, but decreases the maximum energy efficiency of ozone generators. Initial analysis indicates that the optimal proportion of nitrogen addition is inversely related to the average reduced electric field strength in the discharge region.  相似文献   

18.
Ozone production utilizing surface dielectric barrier discharge (SDBD) was experimental studied for different flow patterns considering the influences of transversal flow, lateral flow and different lateral flow positions. Results show that the flow patterns have a remarkable impact on the ozone yield by affecting the uniformity and turbulence of gas flow. Meanwhile, distributing the O2 flow rate according to the intensity of the plasma reaction would also increase the generation efficiency of SDBD for ozone production. By improving the uniformity and introducing the lateral flow to the transversal flow, the highest ozone yield was obtained in flow pattern ‘F’. In this case, the ozone yield increased by 28.4% to 131 gkWh −1 from 102.8 gkWh−1 in flow pattern ‘A’.  相似文献   

19.
A combined method of granular activated carbon (GAC) adsorption and bipolar pulse dielectric barrier discharge (DBD) plasma regeneration was employed to degrade phenol in water. After being saturated with phenol, the GAC was filled into the DBD reactor driven by bipolar pulse power for regeneration under various operating parameters. The results showed that different peak voltages, air flow rates, and GAC content can affect phenol decomposition and its major degradation intermediates, such as catechol, hydroquinone, and benzoquinone. The higher voltage and air support were conducive to the removal of phenol, and the proper water moisture of the GAC was 20%. The amount of H2O2 on the GAC was quantitatively determined, and its laws of production were similar to phenol elimination. Under the optimized conditions, the elimination of phenol on the GAC was confirmed by Fourier transform infrared spectroscopy,and the total removal of organic carbons achieved 50.4%. Also, a possible degradation mechanism was proposed based on the HPLC analysis. Meanwhile, the regeneration efficiency of the GAC was improved with the discharge treatment time, which attained 88.5% after 100 min of DBD processing.  相似文献   

20.
In this paper,the influence of voltage rising time on a pulsed-dc helium-air plasma at atmospheric pressure is numerically simulated.Simulation results show that as the voltage rising time increases from 10 ns to 30 ns,there is a decrease in the discharge current,namely 0.052 A when the voltage rising time is 10 ns and 0.038 A when the voltage rising time is 30 ns.Additionally,a shorter voltage rising time results in a faster breakdown,a more rapidly rising current waveform,and a higher breakdown voltage.Furthermore,the basic paraneters of the streamer discharge also increase with voltage rise rate,which is ascribed to the fact that more energetic electrons are produced in a shorter voltage rising time.Therefore,a pulsed-dc voltage with a short rising time is desirable for efficient production of nonequilibrium atmospheric pressure plasma discharge.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号