首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Due to the complexity of proteome samples, only a portion of peptides and thus proteins can be identified in a single LC-MS/MS analysis in current shotgun proteomics methodologies. It has been shown that replicate runs can be used to improve the comprehensiveness of the proteome analysis; however, high-intensity peptides tend to be analyzed repeatedly in different runs, thus reducing the chance of identifying low-intensity peptides. In contrast to commonly used online ESI-MS, offline MALDI decouples the separation from MS acquisition, thus allowing in-depth selection for specific precursor ions. Accordingly, we extended a strategy for offline LC-MALDI MS/MS analysis using a precursor ion exclusion list consisting of all identified peptides in preceding runs. The exclusion list eliminated redundant MS/MS acquisitions in subsequent runs, thus reducing MALDI sample depletion and allowing identification of a larger number of peptide identifications in the cumulative dataset. In the analysis of the digest of an Escherichia coli lysate, the exclusion list strategy resulted in a 25% increase in the number of unique peptide identifications in the second run, in contrast to simply pooling MS/MS data from two replicate runs. To reduce the increased LC analysis time for repeat runs, a four-column multiplexed LC system was developed to carry out separation simultaneously. The multiplexed LC-MALDI MS provides a high-throughput platform to utilize the exclusion list strategy in proteome analysis.  相似文献   

2.
We have developed an information-dependent, iterative MS/MS acquisition (IMMA) tool for improving MS/MS efficiency, increasing proteome coverage, and shortening analysis time for high-throughput proteomics applications based on the LC-MALDI MS/MS platform. The underlying principle of IMMA is to limit MS/MS analyses to a subset of molecular ions that are likely to identify a maximum number of proteins. IMMA reduces redundancy of MS/MS analyses by excluding from the precursor ion peak lists proteotypic peptides derived from the already identified proteins and uses a retention time prediction algorithm to limit the degree of false exclusions. It also increases the utilization rate of MS/MS spectra by removing "low value" unidentifiable targets like nonpeptides and peptides carrying large loads of modifications, which are flagged by their "nonpeptide" excess-to-nominal mass ratios. For some samples, IMMA increases the number of identified proteins by ~20-40% when compared to the data dependent methods. IMMA terminates an MS/MS run at the operator-defined point when "costs" (e.g., time of analysis) start to overrun "benefits" (e.g., number of identified proteins), without prior knowledge of sample contents and complexity. To facilitate analysis of closely related samples, IMMA's inclusion list functionality is currently under development.  相似文献   

3.
Proteomics analysis based-on reversed-phase liquid chromatography (RPLC) is widely practiced; however, variations providing cutting-edge RPLC performance have generally not been adopted even though their benefits are well established. Here, we describe an automated format 20 kpsi RPLC system for proteomics and metabolomics that includes on-line coupling of micro-solid phase extraction for sample loading and allows electrospray ionization emitters to be readily replaced. The system uses 50 microm i.d. x 40-200 cm fused-silica capillaries packed with 1.4-3-microm porous C18-bonded silica particles to obtain chromatographic peak capacities of 1000-1500 for complex peptide and metabolite mixtures. This separation quality provided high-confidence identifications of >12 000 different tryptic peptides from >2000 distinct Shewanella oneidensis proteins (approximately 40% of the proteins predicted for the S. oneidensis proteome) in a single 12-h ion trap tandem mass spectrometry (MS/MS) analysis. The protein identification reproducibility approached 90% between replicate experiments. The average protein MS/MS identification rate exceeded 10 proteins/min, and 1207 proteins were identified in 120 min through assignment of 5944 different peptides. The proteomic analysis dynamic range of the 20 kpsi RPLC-ion trap MS/MS was approximately 10(6) based on analyses of a human blood plasma sample, for which 835 distinct proteins were identified with high confidence in a single 12-h run. A single run of the 20 kpsi RPLC-accurate mass MS detected >5000 different compounds from a metabolomics sample.  相似文献   

4.
We investigated and compared three approaches for shotgun protein identification by combining MS and MS/MS information using LTQ-Orbitrap high mass accuracy data. In the first approach, we employed a unique mass identifier method where MS peaks matched to peptides predicted from proteins identified from an MS/MS database search are first subtracted before using the MS peaks as unique mass identifiers for protein identification. In the second method, we used an accurate mass and time tag method by building a potential mass and retention time database from previous MudPIT analyses. For the third method, we used a peptide mass fingerprinting-like approach in combination with a randomized database for protein identification. We show that we can improve protein identification sensitivity for low-abundance proteins by combining MS and MS/MS information. Furthermore, "one-hit wonders" from MS/MS database searching can be further substantiated by MS information and the approach improves the identification of low-abundance proteins. The advantages and disadvantages for the three approaches are then discussed.  相似文献   

5.
Garza S  Moini M 《Analytical chemistry》2006,78(20):7309-7316
Identification of proteins, in a complex protein mixture, using one-dimensional high-performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) analysis of its digest, usually suffers from low sequence coverage. There are several reasons for the low coverage including undersampling, wide concentration dynamic range of the proteins in a complex protein mixture, and wide range of electrospray ionization efficiency of peptides under each mobile-phase composition. To address this low sequence coverage, we introduce a novel technique, (CE-MS/MS)n, which utilizes the most significant advantages of CE-MS/MS, including economy of sample size, fast analysis time, and high separation efficiency, to increase the sequence coverage of a complex protein mixture. Based on these characteristics, (CE-MS/MS)n can be performed in which multiple CE-MS/MS subanalyses (injections followed by analyses) are analyzed and experimental variables are manipulated during each CE-MS/MS subanalysis in order to maximize sequence coverage. (CE-MS/MS)n is a practical technique since each CE-MS/MS subanalysis consumes <10 nL, and each CE-MS/MS subanalysis takes approximately 10 min; therefore, several subanalyses can be performed in approximately 1 h consuming only nanoliters of the sample. Two techniques have been introduced to address the undersampling: (1) (CE-MS/MS)n using dynamic exclusion. In this technique, several CE-MS/MS analyses (injection followed by separation) were performed in one run using the dynamic exclusion capability of the mass spectrometer until all peptide peaks were analyzed by MS/MS. (2) Gas-phase fractionation. In this technique, (CE-MS/MS)n is performed by scanning a narrow mass range (every approximately 100 m/z) during each CE-MS/MS subanalysis without using dynamic exclusion. Under this condition, in each subanalysis, the number of peptides available for MS/MS analysis is significantly reduced, and peptides with the same nominal masses are analyzed, thereby increasing sequence coverage. Additionally, to address the lack of detection of low-level peptides in a mixture containing a wide concentration dynamic range, the concentration of the sample was systematically increased in each subanalysis (while utilizing dynamic exclusion) so that low-intensity peptides would rise above the mass spectrometer threshold and, consequently, undergo MS/MS analysis. Moreover, to alter the ionization efficiency of peptides with low electrospray ionization efficiency, and to change the migration behavior of comigrating peptides under a specific liquid composition, the CE background electrolyte was modified in several subanalyses to further improve sequence coverage. The combination of the above-mentioned techniques was applied to the analysis of the tryptic digests of three well-characterized protein mixtures: a six-protein mixture with average MW of approximately 26,000 (standard I), a six-protein mixture with an average MW approximately 49,000 (standard II), and a more complex protein mixture containing 55 proteins (E. coli ribosomal proteins). In approximately 1 h, when the MS/MS of the peptides were manually checked, all peptides that produced peaks under electrospray ionization in the scanned range of the analysis (500-2000 m/z) and within the practical fragmentation capability of the MS (peptides with MW <3500) were identified for standard I by consuming only 200 fmol of each protein. When searched against a Swissprot database, the average sequence coverage for the standard I, II, and E. coli's ribosomal proteins were 57, 34, and 15%, respectively.  相似文献   

6.
This study describes a methodology for performing relative quantitation in large-scale proteomic sample comparisons using an LC-MALDI mass spectrometry analytical platform without the use of isotope tagging reagents. The method utilizes replicate analyses of a sample to create a profile of constituent components that are aligned based on LC elution time and mass. Once components from individual runs have been grouped as common "features", the Student's t test is used to determine which components are systematically different between samples. In this study, five HPLC runs of human plasma were compared to five HPLC runs of human serum. About 3889 components were detected in all 10 runs. Of these, 1831 corresponded to approximately 100 known serum proteins, based on MS/MS analysis of one run each from serum and plasma. As expected, fibrinogen alpha, beta, and gamma chains accounted for many of the most significant differences. Therefore, using MALDI, samples containing thousands of peptides can be compared in a minimal amount of time. Moreover, the results of the comparison can be used to guide further MS/MS mode sample interrogation in a result dependent manner.  相似文献   

7.
Nonenzymatic glycation of tissue proteins has important implications in the development of complications of diabetes mellitus. Herein we report improved methods for the enrichment and analysis of glycated peptides using boronate affinity chromatography and electron-transfer dissociation mass spectrometry, respectively. The enrichment of glycated peptides was improved by replacing an off-line desalting step with an online wash of column-bound glycated peptides using 50 mM ammonium acetate, followed by elution with 100 mM acetic acid. The analysis of glycated peptides by MS/MS was improved by considering only higher charged (> or = 3) precursor ions during data-dependent acquisition, which increased the number of glycated peptide identifications. Similarly, the use of supplemental collisional activation after electron transfer (ETcaD) resulted in more glycated peptide identifications when the MS survey scan was acquired with enhanced resolution. Acquiring ETD-MS/MS data at a normal MS survey scan rate, in conjunction with the rejection of both 1+ and 2+ precursor ions, increased the number of identified glycated peptides relative to ETcaD or the enhanced MS survey scan rate. Finally, an evaluation of trypsin, Arg-C, and Lys-C showed that tryptic digestion of glycated proteins was comparable to digestion with Lys-C and that both were better than Arg-C in terms of the number of glycated peptides and corresponding glycated proteins identified by LC-MS/MS.  相似文献   

8.
Divinyl sulfone reacts at pH 8-9 with the alpha-amino groups of N-terminal residues, proline, the epsilon-amino groups of lysine, and the histidine side chains of peptides. This reaction leads to great enhancement of the abundance of the normally weak or missing "a(1)" fragment ion in MS/MS analysis defining the N-terminal residue of a peptide in a digest. This provides "one-step Edman-like" information that, together with a fairly accurately determined mass, often enables one to correctly identify a protein or family of proteins. The applicability of this procedure in proteomics was demonstrated with several peptides and tryptic digests of protein mixtures by LC-MS/MS experiments using a QTOF and MALDI-PSD analyses. Advantages of this approach are its simple chemistry, retention of charge multiplicity, and possibly, shortening of database search time. Used with other MS/MS data, it provides higher confidence in the scores and identification of a protein found in peptide mass fingerprinting. Moreover, this approach has an advantage in "de novo" sequencing due to its ability to decipher the first amino acid of a peptide whose information is normally unavailable in MS/MS spectra.  相似文献   

9.
Nonenzymatic protein glycation is caused by a Schiff's base reaction between the aldehyde groups of reducing sugars and the primary amines of proteins. A reversed-phase liquid chromatography method followed by a neutral loss scan mass spectrometric method was developed for the screening of glycation in proteins. The neutral loss scan was based on a unique sugar moiety neutral loss (-162 Da) that we observed in the fragmentation spectra of glycated peptides on Q-Tof type mass spectrometers. The collision energy was optimized for this neutral loss using a glycated synthetic peptide, and 20 eV was found to be the optimum collision energy. The neutral loss scan experiment was composed of two segments. In the first segment, the glycated peptides were identified based on the signature neutral loss of 162 Da when the collision energy was elevated to 20 eV. In the second segment, the glycated peptides were selected as the parent ions and fragmented at higher collision energy to break the peptide bonds. The fragmentation spectra of the selected glycated peptides revealed both the amino acid sequences and the sites of glycation. This neutral loss scan method was used to study the glycation in human serum albumin (HSA). The glycation sites in HSA were identified based on the retention time shift of glycated peptides, the mass accuracy from the MS scan, the signature neutral loss, and MS/MS information. Using this method, we were able to identify that 31 lysine residues were partially glycated from the glycated HSA sample, which has a total of 59 lysine residues.  相似文献   

10.
This study demonstrates the ability to perform sensitive proteome analysis on the limited protein quantities available through tissue microdissection. Capillary isoelectric focusing combined with nano-reversed-phase liquid chromatography in an automated and integrated platform not only provides systematic resolution of complex peptide mixtures based on their differences in isoelectric point and hydrophobicity but also eliminates peptide loss and analyte dilution. In comparison with strong cation exchange chromatography, the significant advantages of electrokinetic focusing-based separations include high resolving power, high concentration and narrow analyte bands, and effective usage of electrospray ionization-tandem MS toward peptide identifications. Through the use of capillary isoelectric focusing-based multidimensional peptide separations, a total of 6866 fully tryptic peptides were detected, leading to the identification of 1820 distinct proteins. Each distinct protein was identified by at least one distinct peptide sequence. These high mass accuracy and high-confidence identifications were generated from three proteome runs of a single glioblastoma multiforme tissue sample, each run consuming only 10 microg of total protein, an amount corresponding to 20,000 selectively isolated cells. Instead of performing multiple runs of multidimensional separations, the overall peak capacity can be greatly enhanced for mining deeper into tissue proteomics by increasing the number of CIEF fractions without an accompanying increase in sample consumption.  相似文献   

11.
To facilitate structural analysis of proteins and protein-protein interactions, we developed Pro-CrossLink, a suite of software tools consisting of three programs (Figure 1), DetectShift, IdentifyXLink, and AssignXLink. DetectShift was developed to detect ions of cross-linked peptide pairs in a mixture of 18O-labeled peptides obtained from protein proteolytic digests. The selected candidate ions of cross-linked peptide pairs subsequently undergo tandem mass spectrometric (MS/MS) analysis for sequence determination. Based on the masses of candidate ions as well as y- and b-type ions in the tandem mass spectra, IdentifyXLink assigns the candidate ions to cross-linked peptide pairs. For an identified cross-linked peptide pair, AssignXLink generates an extensive fragment ion list, including a-, b-, c-type, x-, y-, z-type, internal, and immonium ions with associated common losses of H2O, NH3, CO, and CO2, and facilitates a precise location of the cross-linked residues. Pro-CrossLink is automated, highly configurable by the user, and applicable to many studies that map low-resolution protein structures and molecular interfaces in protein complexes.  相似文献   

12.
Chen SH  Hsu JL  Lin FS 《Analytical chemistry》2008,80(13):5251-5259
Fluorescence-based tagging in proteomics is useful in tracking and quantifying target proteins during sample preparation or chromatographic processes. In this study, we report a novel cysteinyl tagging method using a popular fluorophore, fluorescein derivative. Such visible dyes were shown to have multiple unique characteristics, including a unique reporter ion containing the dye moiety caused by collision-induced dissociation (CID) and high affinity toward multicarboxylate functional groups, which could be useful for enhanced selectivity in MS-based proteomics. We used sulfhydryl-reactive 5-iodoacetamidofluorescein to target cysteinyl residues on the intact protein of ovalbumin and bovine serum albumin as well as proteins in MCF-7 cells. After trypsin digestion, the digests were analyzed by nanoLC-ESI-Q-TOF or MALDI-TOF. The resulting MS spectra of tryptic fragments were similar to those of unlabeled or iodoacetamide-derivatized proteins, and the MS/MS fragmentation of all fluorescein-tagged peptides was readily interpretable with intact label. Thus, fluorescein-derivatized proteins can be identified by automatic mass mapping or peptide sequencing with high confidence. It is notable that, in MS/MS mode, a strong reporter ion (m/z 422) containing the fluorescein moiety was readily detected and was believed to derive from the immonium fragment of fluorescein-labeled cysteine residues, f C (m/z 463), under CID conditions. Using a precursor scan of the reporter ion, a cysteinyl protein, ovomucoid, was identified to be present in the ovalbumin sample as an impurity. The fluorescein derivatives were further shown to have high affinities toward metal-chelating materials that have iminodiacetic acid functional groups either with or without the presence of bound metal ions. When coupling with stable isotope dimethyl labeling, fluorescein-tagged peptides could be selectively enriched, identified, and quantified. In view of its popularity, visible tracking, and unique characteristics for developing selective methods, fluorescein tagging holds great promises for targeting proteomics.  相似文献   

13.
Fast mapping of disulfide bonds in proteins containing multiple cysteine residues is often required in order to assess the integrity of the tertiary structure of proteins prone to degradation and misfolding or to detect distinct intermediate states generated in the course of oxidative folding. A new method of rapid detection and identification of disulfide-linked peptides in complex proteolytic mixtures utilizes the tendency of collision-activated peptide ions to lose preferentially side chains of select amino acids in the negative ion mode. Cleavages of cysteine side chains result in efficient dissociation of disulfide bonds and produce characteristic signatures in the fragment ion mass spectra. While cleavages of other side chains result in insignificant loss of mass and full retention of the peptide ion charge, dissociation of external disulfide bonds results in physical separation of two peptides and, therefore, significant changes of both mass and charge of fragment ions relative to the precursor ion. This feature allows the fragment ions generated by dissociation of external disulfide bonds to be easily detected and identified even if multiple precursor ions are activated simultaneously. Such broadband selection of precursor ions for consecutive activation is achieved by lowering the dc/rf amplitude ratio in the first quadrupole filter of a hybrid quadrupole time-of-flight mass spectrometer. The feasibility of the new method is demonstrated by partial mapping of disulfide bridges within a 37-kDa protein containing 16 cysteine residues and complete disulfide mapping within a lysozyme (14.5 kDa) containing 8 cysteine residues. In addition to detecting peptide pairs connected by a single external disulfide, the new method is also shown to be capable of identifying peptides containing both external and internal disulfide bonds. The two major factors determining the efficiency of disulfide mapping using the new methodology are the effectiveness of proteolysis and the ability of the resulting proteolytic fragments to form multiply charged negative ions.  相似文献   

14.
A novel ion trap time-of-flight hybrid mass spectrometer (qIT-TOF MS) has been applied for peptide sequencing in proteolytic digests generated from spore mixtures of Bacilli. The method of on-probe solubilization and in situ proteolytic digestion of small, acid-soluble spore proteins has been recently developed in our laboratory, and microorganism identification in less than 20 min was accomplished. In this study, tryptic peptides were generated in situ from complex spore mixtures of B. subtilis 168, B. globigii, B. thuringiensis subs. Kurstaki, and B. cereus T, respectively. MALDI analysis of bacterial peptides generated was performed with an average mass resolving power of 6200 and a mass accuracy of up to 10 ppm using a trap-TOF tandem configuration. Precursor ions of interest were usually selected and stored in the quadrupole ion trap with their complete isotope distribution by choosing a window of +/- 2 Da. Sequence-specific information on isolated protonated peptides was gained via tandem MS experiments with an average mass resolving power of 4450 for product ion analysis, and protein and bacterial sources were identified by database searching.  相似文献   

15.
The use of artificial neural networks (ANNs) is described for predicting the reversed-phase liquid chromatography retention times of peptides enzymatically digested from proteome-wide proteins. To enable the accurate comparison of the numerous LC/MS data sets, a genetic algorithm was developed to normalize the peptide retention data into a range (from 0 to 1), improving the peptide elution time reproducibility to approximately 1%. The network developed in this study was based on amino acid residue composition and consists of 20 input nodes, 2 hidden nodes, and 1 output node. A data set of approximately 7000 confidently identified peptides from the microorganism Deinococcus radiodurans was used for the training of the ANN. The ANN was then used to predict the elution times for another set of 5200 peptides tentatively identified by MS/MS from a different microorganism (Shewanella oneidensis). The model was found to predict the elution times of peptides with up to 54 amino acid residues (the longest peptide identified after tryptic digestion of S. oneidensis) with an average accuracy of approximately 3%. This predictive capability was then used to distinguish with high confidence isobar peptides otherwise indistinguishable by accurate mass measurements as well as to uncover peptide misidentifications. Thus, integration of ANN peptide elution time prediction in the proteomic research will increase both the number of protein identifications and their confidence.  相似文献   

16.
We describe the practical implementation of a new RP (pH 10 - pH 2) 2D HPLC-ESI/MS scheme for large-scale bottom-up analysis in proteomics. When compared to the common SCX-RP approach, it provides a higher separation efficiency in the first dimension and increases the number of identified peptides/proteins. We also employed the methodology of our sequence-specific retention calculator (SSRCalc) and developed peptide retention prediction algorithms for both LC dimensions. A diverse set of approximately 10,000 tryptic peptides from the soluble protein fraction of whole NK-type cells gave retention time versus hydrophobicity correlations, with R (2) values of 0.95 for pH 10 and 0.945 for pH 2 (formic acid) separation modes. The superior separation efficiency and the ability to use retention prediction to filter out false-positive MS/MS identifications gives promise that this approach will be a method of choice for large-scale proteomics analyses in the future. Finally, the "semi-orthogonal" separation selectivity permits the concatenation of fractions in the first dimension of separation before the final LC-ESI MS step, effectively cutting the analysis time in half, while resulting in a minimal reduction in protein identification.  相似文献   

17.
Top-down proteomics for rapid identification of intact microorganisms   总被引:2,自引:0,他引:2  
We apply MALDI-TOF/TOF mass spectrometry for the rapid and high-confidence identification of intact Bacillus spore species. In this method, fragment ion spectra of whole (undigested) protein biomarkers are obtained without the need for biomarker prefractionation, digestion, separation, and cleanup. Laser-induced dissociation (unimolecular decay) of higher mass (>5 kDa) precursor ions in the first TOF analyzer is followed by reacceleration and subsequent high-resolution mass analysis of the resulting sequence-specific fragments in a reflectron TOF analyzer. In-house-developed software compares an experimental MS/MS spectrum with in silico-generated tandem mass spectra from all protein sequences, contained in a proteome database, with masses within a preset range around the precursor ion mass. A p-value, the probability that the observed matches between experimental and in silico-generated fragments occur by chance, is computed and used to rank the database proteins to identify the most plausible precursor protein. By inference, the source microorganism is then identified on the basis of the identification of individual, unique protein biomarker(s). As an example, intact Bacillus atrophaeus and Bacillus cereus spores, either pure or in mixtures, were unambiguously identified by this method after fragmenting and identifying individual small, acid-soluble spore proteins that are specific for each species. Factors such as experimental mass accuracy and number of detected fragment ions, precursor ion charge state, and sequence-specific fragmentation have been evaluated with the objective of extending the approach to other microorganisms. MALDI-TOF/TOF-MS in a lab setting is an efficient tool for in situ confirmation/verification of initial microorganism identification.  相似文献   

18.
A new algorithm, sequence-specific retention calculator, was developed to predict retention time of tryptic peptides during RP HPLC fractionation on C18, 300-A pore size columns. Correlations of up to approximately 0.98 R2 value were obtained for a test library of approximately 2000 peptides and approximately 0.95-0.97 for a variety of real samples. The algorithm was applied in conjunction with an exclusion protocol based on mass (15 ppm tolerance) and retention time (2-min tolerance for 0.66% acetonitrile/min gradient), MART criteria to significantly reduce the instrument time required for complete MS/MS analysis of a digest separated by RP HPLC. This was confirmed by reanalyzing the set of HPLC-MALDI MS/MS data with no loss in protein identifications, despite the number of virtually executed MS/MS analyses being decreased by 57%.  相似文献   

19.
Tyrosine-O-sulfated peptides were studied by nanoESI Q-TOF mass spectrometry and were found to exhibit an abundant loss of SO3 in positive ion mode under the usually nonfragmenting conditions of survey spectrum acquisition. A new strategy for the detection of tyrosine-O-sulfated peptides in total protein digests was designed based on exhaustive product ion scanning at the collision offset conditions typical for the recording of survey spectra (minimum collision offset). From these data, Q-TOF neutral loss scans for loss of 80/z and Q-TOF precursor ions scans were extracted. The specificity of this approach for analysis of tyrosine-O-sulfation was tested using a tryptic digest of bovine serum albumin spiked with sulfated hirudin (1:1 and 1000:1 molar ratio of BSA to sulfated hirudin, respectively) and using an in-solution digest of the recombinant extracellular domain of thyroid stimulating hormone receptor (ECD-TSHr). For both examples, the combination of in silico neutral loss scans for 80/z and subsequent in silico precursor ion scans resulted in a specific identification of sulfated peptides. In the analysis of recombinant ECD-TSHr, a doubly sulfated peptide could be identified in this way. Surprisingly, approximately 1/4 of the product ion spectra acquired from the tryptic digest of ECD-TSHr at minimum collision offset exhibited sequence-specific ions suitable for peptide identification. Complementary ion pairs were frequently observed, which either were b2/y(max-2) pairs or were induced by cleavage N-terminal to proline. MS/MS analysis at minimum collision offset followed by extraction of neutral loss and precursor ion scans is ideally suited for highly sensitive detection of analyte ions which exhibit facile gas-phase decomposition reactions.  相似文献   

20.
Amino acid sequence variations resulting from single-nucleotide polymorphisms (SNPs) were identified using a novel mass spectrometric method. This method obtains 99+% protein sequence coverage for human hemoglobin in a single LC-microspray tandem mass spectrometry (microLC-MS/MS) experiment. Tandem mass spectrometry data was analyzed using a modified version of the computer program SEQUEST to identify the sequence variations. Conditions of sample preparation, chromatographic separation, and data collection were optimized to correctly identify amino acid changes in six variants of human hemoglobin (Hb C, Hb E, Hb D-Los Angeles, Hb G-Philadelphia, Hb Hope, and Hb S). Hemoglobin proteins were isolated and purified, dehemed, (S)-carboxyami-domethylated, and then subjected to a combination proteolytic digestion to obtain a complex peptide mixture with multiple overlaps in sequence. Reversed-phase chromatographic separation of peptides was achieved on-line with MS utilizing a robust fritless microelectrospray interface. Tandem mass spectrometry was performed on an ion trap mass spectrometer using automated data-dependent MS/MS procedures. Tandem mass spectra were collected from the five most abundant ions in each scan using dynamic and isotopic exclusion to minimize redundancy. The spectra were analyzed by a version of the SEQUEST algorithm modified to identify amino acid substations resulting from SNPs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号