首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The exhaust gas of heavy duty diesel engines can provide an important heat source that may be used in a number of ways to provide additional power and improve overall engine efficiency. The sizing of a heat exchanger that can manage the heat load and still be of reasonable size and weight without excessive pressure drop is of significant importance especially for truck applications. This is the subject of the present work. To approach the problem, a total of five different configurations are investigated and a comparison of conventional and state of the art heat transfer enhancement technologies is included. Two groups of configurations are examined: (a) a classical shell and tube heat exchanger using staggered cross-flow tube bundles with smooth circular tubes, finned tubes and tubes with dimpled surfaces and (b) a cross-flow plate heat exchanger, initially with finned surfaces on the exhaust gas side and then with 10 ppi and 40 ppi metal foam material substituting for the fins. Calculations were performed, using established heat exchanger design methodologies and recently published data from the literature to size the aforementioned configurations. The solutions provided reduce the overall heat exchanger size, with the plate and fin type consisting of plain fins presenting the minimum pressure drop (up to 98% reduction compared to the other configurations), and the 40 ppi metal foam being the most compact in terms of size and weight. Durability of the solutions is another issue which will be examined in a future investigation. However, coupling of the exhaust heat exchanger after a particulate trap appears to be the most promising solution to avoid clogging from soot accumulation.  相似文献   

2.
This paper presents a finite-difference based numerical simulation of steady, laminar heat transfer in circular tubes fitted with four identical longitudinal fins having tapered lateral profiles. The lateral view of the tip of each fin is a circular arc. The tube is exposed to constant heat flux. The temperature dependence of thermal conductivity and viscosity has been taken into account. The flow is assumed to be locally fully developed but thermally undeveloped. The momentum equation for the fluid and energy equations for the fluid and the tube wall with/without fins are solved iteratively and simultaneously. At each axial location, bulk velocity, bulk temperature of the fluid and Effectiveness which is an indicator of the enhancement of heat transfer due to addition of fins are calculated. A parametric study of effectiveness vs. axial distance for various combinations of fin materials and coolants reveals interesting results. The velocity profiles, friction factors and comparisons with respect to constant property solutions have also been discussed.  相似文献   

3.
The heat transfer behavior of phase change material fluid (PCM) under laminar flow conditions in circular tubes and internally longitudinal finned tubes was studied. An effective specific heat technique was used to model the phase change process. Heat transfer results for a smooth circular tube with PCM fluid were obtained under hydrodynamically and thermally fully developed conditions. Results for the finned tube were obtained using the H2 and T boundary conditions. It was determined that the Nusselt number was strongly dependent on the Stefan number, fin thermal conductivity value, and height of the fins.  相似文献   

4.
This investigation stems from the area of augmentation of heat transfer by generating streamwise longitudinal vortices. The vortex generators are arranged in a common-flow-up configuration. Existing air-cooled condensers in geothermal power plants use fin-tube heat exchangers with circular tubes. The heat exchangers are huge, and often the cost of the condensers is more than one-third of the plant cost. The size of the condensers can be reduced through enhancement of heat transfer from fin surfaces. The enhancement strategy involves introduction of strong swirling motion in the flow field. The swirl can be generated by the longitudinal vortices. In this study, the longitudinal vortices are created by delta winglet-type vortex generators, which are mounted behind the tubes. An element of a heat exchanger has been considered for detailed study of the flow structure and heat transfer analysis. Biswas and colleagues have obtained significant enhancement of heat transfer by deploying the winglet pair behind each tube. In this study, a novel technique (Torii and colleagues [2]) has been utilized for the enhancement. The winglets are placed with a heretofore unused orientation for the purpose of augmentation of heat transfer. This orientation is called the common-flow-up configuration. The proposed method causes significant separation delay, reduces form drag, and removes the zone of poor heat transfer from the near wake of the tubes. The analyses of flow and heat transfer in the proposed configuration have been accomplished through a numerical solution of complete Navier-Stokes and energy equations.  相似文献   

5.
A finite volume numerical scheme is utilized to predict fluid flow and heat transfer characteristics in inline tube banks. The effect of equipping the tubes with longitudinal fins on the pressure drop and heat transfer is studied. The governing equations for fluid flow and heat transfer are numerically solved, with the assumption of periodic, fully developed flow. The numerical methodology utilizes the stepped boundary technique to approximate the tube surface. The tubes are maintained at a constant temperature, and the calculations are carried out for laminar flow and for a large range of Reynolds and Prandtl numbers. The results for the unfinned tube case are compared with previously published experimental data. The numerical results agree well with the experimental measurements. Representative results for the case of the finned tubes indicate, surprisingly, a decrease in the heat transfer rate, and small changes in the pressure drop, as a result of finning. The decrease in the heat transfer rate probably occurs because the fins are placed in the stagnation regions at the front and rear of the tubes, and thus do not increase the heat transfer.  相似文献   

6.
An experimental energy storage system has been designed using a horizontal concentric tube heat exchanger incorporating a medium temperature phase change material (PCM) Erythritol, with a melting point of 117.7 °C. Three experimental configurations, a control system with no heat transfer enhancement and systems augmented with circular and longitudinal fins have been studied. The results presented compare the system heat transfer characteristics using isotherm plots and temperature-time curves. The system with longitudinal fins gave the best performance with increased thermal response during charging and reduced subcooling in the melt during discharging. The experimentally measured data for the control, circular finned and longitudinal finned systems have been shown to vindicate the assumption of axissymmetry (direction parallel to the heat transfer fluid flow) using temperature gradients in the axial, radial and angular directions in the double pipe PCM system.  相似文献   

7.
The enhancement of heat transfer in a thermal storage system consisting of a cylindrical vertical tube with internal longitudinal fin arrangement is discussed in this paper. This configuration that forms a V-shaped enclosure for the phase change material (PCM) gives maximum benefit to the fin arrangement. A theoretical model that also accounts for the circumferential heat flow through the tube wall is developed using enthalpy formulation and is employed in conjunction with the fully implicit finite difference method to solve the solidification in the convectively cooled vertical tube. A generalised enthalpy-temperature (H-T) relationship, developed by Date, is suitable for constant phase change temperature and this is modified in the present work to accommodate materials having either constant or a range of phase change temperatures. The numerical model is validated with experimental data. The instantaneous surface heat flux and the solidified fraction for different number of fins and tube radii, that are of interest for the design of latent heat thermal storage system consisting of an array of vertical cylindrical tubes containing PCM inside it, are also discussed in this article.  相似文献   

8.
Numerical study of laminar free convection about a single pin fin attached to a horizontal base plate has been reported in this article. Fluid at the far field moves horizontally towards the fin and then rises almost vertically along the fin and finally leaves through the top. With the increase in fin diameter heat transfer increases while the heat flux at fin base decreases establishing the advantage of large number of small diameter fins over fewer fins of bigger diameter. Correlation has been developed to predict the base heat flux for a given fin diameter to length ratio and Grashof number. This may be used to estimate the upper limit of free convection heat transfer from any horizontal heat sink with an array of circular pin elements.  相似文献   

9.
In this technical note, the problem concerning the quantification of heat transfer rates from an array of longitudinal radiating fins of rectangular profile in a tube/fin ensemble to a nonzero temperature sink is investigated. Radiating fins constitute essential elements in the thermal control of spacecrafts and satellites. We consider quasi one-dimensional heat conduction in the longitudinal radiating fins and neglect radiative exchange between the fins and the tubes carrying a hot fluid. It is demonstrated that the governing nonlinear differential equation of second order with constant coefficients and nonhomogeneous can be solved in exact, analytical implicit form. The pertinent temperature distributions eventually provide the magnitudes of heat transfer rates and fin efficiencies influenced by the radiation–conduction parameter and the sink temperature.  相似文献   

10.
Air-side heat transfer and friction characteristics of nine kinds of fin-and-tube heat exchangers, with a large number of tube rows (6, 9, and 12, respectively) and large diameter of tubes (18 mm), are experimentally investigated. The test samples consist of three types of fin configurations: plain fin, slit fin, and fin with delta-wing longitudinal vortex generators. The working fluid in the tube is steam. Results show that when the number of tube is larger than 6, the heat transfer and friction performance for three kinds of fins is independent of the number of tube rows, and slit fin provides higher heat transfer and pressure drop than the other two fins. The heat transfer and friction factor correlations for all the heat exchangers were acquired with Reynolds numbers ranging from 4000 to 10000. The air-side performance of heat exchangers with plain fin, slit fin, and longitudinal vortex-generator fin were evaluated under three sets of criteria, and the results showed that the heat exchanger with slit fin has better performance than that with vortex-generator fin, especially at high Reynolds numbers.  相似文献   

11.
Pressure drop and heat transfer characteristics of air in three annular tubes with different internal longitudinal fins were investigated experimentally at uniform wall heat flux. The tested tubes have a double‐pipe structure with the inner blocked tube as an insertion. Three different kinds of fins, plain rectangle fin, plain rectangle fin with periodical ridges and wave‐like fin, were located peripherally in the annulus. The friction factor and Nusselt number can be corrected by a power‐law correction in the Reynolds number range tested. It was found that the tube with periodical ridges on the plain fin or with wave‐like fin could augment heat transfer; however, the pressure drop was increased simultaneously. In order to evaluate the comprehensive heat transfer characteristics of the tested tubes, two criteria for evaluating the comprehensive thermal performance of tested tubes were adopted. They are: 1) evaluating the comprehensive heat transfer performance under three conditions: identical mass flow, identical pumping power, and identical pressure drop; 2) the second law of thermodynamics, i.e., the entropy generation. According to the two different evaluating methods, it was found that the tube with wave‐like fins provided the most excellent comprehensive heat transfer performance among the three tubes, especially when it was used under higher Reynolds number conditions. © 2007 Wiley Periodicals, Inc. Heat Trans Asian Res, 37(1): 29–40, 2008; Published online in Wiley InterScience ( www.interscience.wiley.com ). DOI 10.1002/htj.20186  相似文献   

12.
The heat transfer and fluid flow characteristics of a new type of fin with built-in interrupted delta winglets is studied in this paper by three-dimensional numerical simulation. In order to ensure reliability of numerical model, plate fin with common-flow-up delta winglets is firstly simulated. The comparison of numerical and experimental results shows a maximum deviation of 11.4% within the entire range of Reynolds number. The computational results show that heat transfer capacity and overall performance increase by 35–60% and 19–64%, respectively. The flow field visualization shows that the interrupted delta winglets can produce longitudinal vortices at the rear of delta winglets and reduce the wake zone behind the tube, so the proposed fin can enhance heat transfer accompanied by low pressure loss. The field synergy theory and entransy dissipation extremum principle are employed on analyzing the mechanism of heat transfer enhancement. The results indicate that enhancement heat transfer mechanism of interrupted delta winglets can be explained as the result of the decrease of synergy angle and reduction of the entransy dissipation.  相似文献   

13.
The heat transfer enhancement performance of a phase change buried tubes thermal storage system is influenced by major parameters such as arrangement of heat transfer tubes, fin structure and fin geometry size. We developed a three-dimensional numerical model with two different arrangements and five different enhanced heat transfer structures respectively. For the sake of analysis the effects of arrangement of heat transfer tubes, fin structure and fin geometry size. In addition, we applied the enthalpy-transforming model to obtain the liquid fraction and location of the solid-liquid interface at different time in the phase change process. The numerical results show that the melting time of the thermal storage system model with a triangle arrangement is about 6.1% longer than that of the model with a square arrangement. Besides, the melting time of the model with 55 mm tube pitch is about 16.7% shorter than that of tube pitch with 60 mm. Moreover, the buried tube thermal storage system models with circle fins have the shortest melting time, which is 18 seconds. Melting time of the model with circle fins is about 40% shorter than that of the model with smooth tube. In addition, the melting time of the model with 3 mm fin thickness is 10 seconds, which is the shortest. The model with thicker fins means the shorter time of melting process. Moreover, the melting time of the model with 10.5 mm fin spacing is about 23.5% shorter than that of the model with 12.5 mm fin spacing, which is 13 seconds. In conclusion, the main factor of the melting time is the heat transfer area. It provides a guidance for the design and reconstruction of the type of heat storage structure.  相似文献   

14.
A peripheral finned-tube, cross-flow heat exchanger (evaporator) is briefly introduced that allows for uninterrupted and effective air flow in the presence of condensate or frost. The peripheral fins are connected to tubes with radial fins and the surface areas of both radial and peripheral fins allow for surface-convection heat transfer. The peripheral fins have a staggered arrangement to allow for alternate air flow paths in the presence of a blockage. Optimized fin structure is sought using one-dimensional fin models. The peripheral fins allow for significant surface-convection by using the stagnation–flow regions as well as the boundary–layer break ups. The CFD results show that the peripheral fins mitigate the pressure drop penalty due to blockages and in this regard present an advantage over the conventional fins. CFD results show that fin pitch can be optimized. The anisotropy of the peripheral fin structure may also allow for easy drainage of the condensate along the tubes when tubes are along gravity.  相似文献   

15.
An enhancement technique is developed for natural convection heat transfer from a vertical heated plate with inclined fins, attached on the vertical heated plate to isolate a hot air flow from a cold air flow. Experiments are performed in air for inclination angles of the inclined fins in the range of 30° to 90° as measured from a horizontal plane, with a height of 25 to 50 mm, and a fin pitch of 20 to 60 mm. The convective heat transfer rate for the vertical heated plate with inclined fins at an inclination angle of 60° is found to be 19% higher than that for a vertical heated plate with vertical fins. A dimensionless equation on the natural convection heat transfer of a vertical heated plate with inclined fins is presented. © 2007 Wiley Periodicals, Inc. Heat Trans Asian Res, 36(6): 334–344, 2007; Published online in Wiley InterScience ( www.interscience.wiley.com ). DOI 10.1002/htj.20168  相似文献   

16.
Heat transfer improvement in a water wall tube with fins was investigated in a circulating fluidized bed (CFB) boiler. Experiments were first conducted in a 6 MWth CFB boiler then a model was developed to analyse and interpolate the results. Temperatures at some discrete points within the wall cross‐section of the tube were measured by burying 0.8 mm thermocouples within a tube. Experimental data showed an increase in heat absorption up to 45 per cent. A good agreement between measured and predicted values was noted. The distribution of temperature in the metal wall and of heat flux around the outer wall of a tube with longitudinal and lateral fins was analysed by numerical solution of a two‐dimensional heat conduction equation. Effects of bed‐to‐wall heat transfer coefficient, water‐to‐tube inside heat transfer coefficient, bed temperature, water temperature and thermal conductivity of the tube material on the heat flux around the water tube are discussed. The present work also examines the influence of the length of the longitudinal fin and the water tube thickness. Heat flux was highest at the tip of the longitudinal fin. It dropped, but increased again near the root of the lateral fin. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

17.
New experimental data are reported for condensation of R-113 at near atmospheric pressure and low velocity on five three-dimensional pin-fin tubes. The only geometric parameters varied were circumferential spacing and thickness, since these have been shown to have a strong effect on condensate retention on pin-fin tubes. Heat transfer enhancement was found to be strongly dependent on the active-area enhancement, i.e., on the parts of the tube and pin surface not covered by condensate retained by surface tension. For all the tubes, vapor-side heat transfer enhancements were found to be approximately 2.5 times the corresponding active-area enhancements, and this finding was in line with earlier data for R-113. An increase in the vapor-side heat transfer enhancement is noticed with the decreasing values of pin spacing. The best performing pin-fin tube gave a heat transfer enhancement about 14% higher than the “equivalent” two-dimensional integral-fin tube (i.e., with the same fin root diameter, longitudinal fin spacing, and thickness and fin height).  相似文献   

18.
The maximization of volumetric heat transfer density from radially finned tubes in cross-flow is investigated in this study based on the constructal design method. A row of radially finned tubes is placed in cross-air flow. The tubes and the radial fins are heated at uniform temperatures and cooled by the air cross-flow. The cross-air flow is generated by a finite pressure difference. Two dimensionless pressure differences (Bejan number) are considered (Be = 103 and Be = 105). The objective function, the degrees of freedom, and the constraints in the constructal design method should be identified. The objective function is the maximization of the heat transfer density from the finned tubes. The degrees of freedom are; the fin tip-to-fin tip spacing, the number of fins, the tube diameter, the fin thickness, and the angle between the fins. The constraints are the length and height of the space occupied by the finned tubes. The pressure-driven flow and energy equations (steady, two-dimensional, and incompressible) are solved by means of the finite volume method. The ranges of the dimensionless fin tip-to-fin tip spacing are (0.2 ≤ S ≤ 1 for Be = 103 and 0.05≤ S ≤ 0.3 for Be = 105). The number of fins is changed as (N = 2, 4, 6, 8, 10, and 12). The dimensionless tube diameter is changed as (D = 0.25, 0.5, and 0.75). The dimensionless fin thickness is changed as (T = 0.001, 0.01, and 0.05). The results showed that for both (Be = 103) and (Be = 105), the highest value of the maximum volumetric heat transfer density is for (N = 2) and decreases as the number of fins increases. In addition, the minimum values of the maximum volumetric heat transfer density occur when the vertical fins exist at (N = 4, 8, and 12).  相似文献   

19.
Conjugate numerical solution of laminar free convection about a horizontal cylinder with external longitudinal fins of finite thickness has been carried out. Fins alone contribute very small to the total heat transfer but they greatly influence the heat transfer from the uncovered area of the cylinder. Among the various fin parameters, thickness has the greatest influence on heat transfer. The rate of heat transfer is above that for the free cylinder only when the attached fins are very thin. For thin fins, there exist a fin length, which maximizes the rate of heat transfer. The optimum number and dimensionless length of the fins were obtained as 6 and 0.2 respectively when fin thickness is 0.01, the thinnest among those investigated in this study.  相似文献   

20.
Experiments were conducted in a cold model circulating fluidized bed having riser cross-sectional area of 100 mm × 100 mm, height of 4.8 m, bed temperature of 75 °C and superficial velocity of 8 m s?1. Local sand having average diameter of 231 μm was used as bed material. The experiments were conducted for three tube configurations: membrane tube, membrane tube with a longitudinal fin at the tube crest and membrane tube with two longitudinal fins at 45° on both sides of the tube crest. The results show that membrane tubes with one and two longitudinal fins have higher heat transfer than membrane tubes and the heat is mainly transferred in the combination portion of tube and membrane fins. In addition, the membrane tube has the highest heat transfer coefficient.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号