1.
A model for the bed-to-wall heat transfer under low temperature condition in a circulating fluidized bed (CFB) was developed based upon a simplified cluster renewal concept. The age of clusters in contact with the wall at different locations along the height of the CFB was estimated as the weighted average age considering their formation and disintegration. One set of experimental data on heat transfer in a 4.5-metre high, 0.15-metre diameter CFB under low temperature condition (67–77°C) was chosen for comparison with prediction of local heat transfer coefficient. The experimental observation and prediction have shown a qualitative agreement.  相似文献   

2.
The axial and radial variation of the heat transfer coefficient in a circulating fluidized bed riser column, and the effect of operating parameters thereon, are investigated. The experimental set-up consists of a riser column of 102 mm×102 mm in bed cross-section, 5·25 m in height with a return leg of the same dimensions. The unit is fabricated with plexiglass columns of 0·6 m in length which are interchangeable with one another. Two axial heat transfer test sections of 102 mm×102 mm in cross-section, 500 mm in height, and made of mild steel, are employed for the axial heat transfer study and one horizontal tube section of 22·5 mm OD made of mild steel is employed for the radial heat transfer study. The primary air velocity is varied between 4·21 and 7·30 m s−1. Local sand of mean size (dp) 248 μm is used as the bed material. One empirical model with the help of dimensional analysis has been proposed to predict the heat transfer coefficient to a bare horizontal tube in a CFB riser column and the model results are validated with the experimental data; good agreement has been observed. © 1997 John Wiley & Sons, Ltd.  相似文献   

3.
An experimental investigation was carried out to study the effects of operating parameters on the local bed-to-wall heat transfer coefficient in a 4.5 m tall, 0.150 m diameter circulating fluidized bed with a bed temperature in the range of 65°C to 80°C, riser flow rate varying from 1400 litres/min to 2000 litres/min, bed inventory in the range of 15 kg to 25 kg of sand, and average sand sizes of 200 μm, 400 μm and 500 μm. A heat flux probe was attached to the riser wall at five different vertical locations for measuring the heat flux from the bed to the wall surface. From the present work, the heat transfer coefficient in the dilute phase was found to be in the range of 62 to 83 W/m2K, 51 to 74 W/m2K, and 50 to 59 W/m2 K for sand sizes of 200 μm, 400 μm and 500 μm, respectively. Relevant mathematical correlations were developed to predict local heat transfer coefficient based on the results of the practical work.  相似文献   

4.
In order to enhance heat transfer and mitigate contamination in the boiling processes, a new type of vapor-liquid-solid (3-phase) circulating fluidized bed boiling system has been designed, combining a circulating fluidized bed with boiling heat transfer. Experimental results show an enhancement of the boiling curve. Flow visualization studies concerning flow hydrodynamics within the riser column are also conducted whose results are presented and discussed.  相似文献   

5.
In order to enhance heat transfer and mitigate contamination in the boiling processes, a new type of vapor-liquid-solid (3-phase) circulating fluidized bed boiling system has been designed, combining a circulating fluidized bed with boiling heat transfer. Experimental results show an enhancement of the boiling curve. Flow visualization studies concerning flow hydrodynamics within the riser column are also conducted whose results are presented and discussed.  相似文献   

6.
In the discrete ordinates method (DOM), the normalized condition for the numerical quadrature of some complex scattering phase functions may not be satisfied. In this paper, a revised discrete ordinates method (RDOM) is developed to overcome this problem, in which a renormalizing factor is added into the numerical quadrature of in-scattering term. The RDOM is used to solve the radiative transfer problem in one-dimensional anisotropically scattering media with complex phase function. The radiative heat fluxes obtained by the RDOM are compared with those obtained by the conventional discrete ordinates method (CDOM) and Monte Carlo method. The results show the RDOM can overcome the false scattering resulted from the numerical quadrature of in-scattering term and improve largely the accuracy of solution of the radiative transfer equation by comparison with the CDOM.  相似文献   

7.
Knowledge of heat transfer coefficients is important in the design and operation of CFB boilers. It is the key to determining the area and the layout of the heat transfer surfaces in a CFB furnace. Local bulk density has a close relationship to the local heat transfer coefficient. Using a heat flux probe and bulk density sampling probe, the local bed to wall heat transfer coefficient in the furnace of a 75 t/h CFB boiler was measured. According to the experimental results and theoretical analysis of the facts that influence the heat transfer, the heat transfer coefficient calculation method for the CFB furnace was developed. The heat transfer surface configuration, heating condition, and the material density are considered in this method. The calculation method has been used in the design of CFB boilers with a capacity from 130 t/h to 420 t/h. © 2002 Wiley Periodicals, Inc. Heat Trans Asian Res, 31(7): 540–550, 2002; Published online in Wiley InterScience ( www.interscience.wiley.com ). DOI 10.1002/htj.10056  相似文献   

8.
INTRODUCTIONThemethodhowtodealwiththedomesticandindustrialwasteswithoutfurthercontaminationisoneofthemostimportantenvironmentalissues.Fluidizedbedcombustor(FBC)hasadvantagesofhighcombustionefficiency)lowpollution,convenienceinpreprocessingbeforefedin...  相似文献   

9.
An experimental investigation was conducted to study the effect of pin fins on heat transfer in circulating fluidized beds. Experiments were conducted in a 100 mm i.d., 5.15 m tall CFB unit, initially with no fins and then with 16-pin and 32-pin fins. Each pin was 6.35 mm in diameter and 15 mm long. It was observed that, although the heat transfer coefficient decreases with the use of fins, the total heat transfer increases owing to the increase in surface area which the fins provide. The results of heat transfer for unfinned surface were compared with those of other workers and found to be in good agreement.  相似文献   

10.
Heat transfer of a furnace in a large-scale circulating fluidized bed (CFB) boiler was studied based on the analysis of available heat transfer coefficient data from typical industrial CFB boilers and measured data from a 12 MWe, a 50 MWe and a 135 MWe CFB boiler. The heat transfer of heat exchanger surfaces in a furnace, in a steam/water cooled cyclone, in an external heat exchanger and in the backpass was also reviewed. Empirical correlation of heat transfer coefficient was suggested after calculating the two key parameters, solids suspension density and furnace temperature. The correlation approach agrees well with the data from the large-scale CFB boilers. __________ Translated from Journal of Power Engineering, 2006, 26(3): 305–310 (in Chinese) [译自: 动力工程]  相似文献   

11.
Heat transfer improvement in a water wall tube with fins was investigated in a circulating fluidized bed (CFB) boiler. Experiments were first conducted in a 6 MWth CFB boiler then a model was developed to analyse and interpolate the results. Temperatures at some discrete points within the wall cross‐section of the tube were measured by burying 0.8 mm thermocouples within a tube. Experimental data showed an increase in heat absorption up to 45 per cent. A good agreement between measured and predicted values was noted. The distribution of temperature in the metal wall and of heat flux around the outer wall of a tube with longitudinal and lateral fins was analysed by numerical solution of a two‐dimensional heat conduction equation. Effects of bed‐to‐wall heat transfer coefficient, water‐to‐tube inside heat transfer coefficient, bed temperature, water temperature and thermal conductivity of the tube material on the heat flux around the water tube are discussed. The present work also examines the influence of the length of the longitudinal fin and the water tube thickness. Heat flux was highest at the tip of the longitudinal fin. It dropped, but increased again near the root of the lateral fin. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

12.
Macroscopic (semi-empirical) models for fluid dynamics of circulating fluidized bed (CFB) units are presented, with emphasize on applications for conditions relevant to industrial units such as fluidized-bed combustors. In order to make a structured analysis of the models, the CFB unit is divided into 6 fluid dynamical zones, which have been shown to exhibit different fluid-dynamical behaviour (bottom bed, freeboard, exit zone, exit duct, cyclone and downcomer and particle seal). The paper summarizes the main basis and assumptions for each model together with major advantages and drawbacks. In addition, a practical example on how a selected set of these local models can be linked to an overall model of the fluid dynamics of the entire CFB loop is presented. It is shown that it is possible to reach good agreement between the overall model and experimental data from industrial units.  相似文献   

13.
An experimental investigation was made to study the effect of vertical probe height on heat transfer at the wall in circulating fluidized beds. Experiments were conducted in a 100 mm internal diameter, 5.15 m tall circulating fluidized bed. Four probes having 85, 127.5, 170 and 255 mm heights were tested. Heat transfer measurements covered a range of superficial velocity from 7.2 to 12.5 m/s and a range of suspension density from 25 to 68 kg/m3. The results were compared with those of other investigators. An empirical correlation incorporating the dimensionless probe height and the particle Nusselt number and Reynolds number has been suggested.  相似文献   

14.
In the present work, the fundamental mechanism between bed‐to‐membrane water‐walls in the riser column of a circulating fluidized bed (CFB) combustor is presented. The bed‐to‐membrane water‐wall heat transfer depends on the contributions of particle heat transfer, dispersed phase heat transfer and radiation heat transfer. The fundamental mechanism of particle heat transfer and the effect of fraction of wall exposed to clusters and gas gap thickness between cluster and wall on particle heat transfer coefficient and bed‐to‐wall heat transfer coefficient are investigated. The influence of operating parameters like cross‐sectional average volumetric solids concentration and bed temperature on particle and bed‐to‐wall heat transfer are also reported. The present work contributes some fundamental information on particle heat transfer mechanism, which is responsible for increasing the bed‐to‐wall heat transfer coefficient (apart from dispersed phase convection and radiation heat transfer). The details on particle heat transfer mechanism will enable to understand the basic heat transfer phenomena between bed‐to‐membrane water‐walls in circulating fluidized bed combustors in a detailed way, which in turn will aid for better design of CFB combustor units. The particle heat transfer mechanism is significantly influenced by the fraction of wall exposed to clusters and gas gap thickness between clusters and wall. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

15.
Heat transfer characteristics in a small-scale fluidized bed boiler (2MWth) were studied using lignite and corn cob as fuels. Depending on air velocity, the heat transfer rates from bed to water membrane wall and from hot flue gas to convective tube bank were in the ranges 75–55% and 25–45% of the total heat absorbed by the boiler, respectively. At designed capacity, the heat transfer flux based on bed cross sectional area and on water membrane wall area were about 0·45 and 0·15 MWm−2, respectively. Under the conditions studied, it was found that the overall heat transfer coefficient between bed and water membrane wall was 100–300 W m−2 K−1, whereas that between flue gas and convective tube bank was 10–30 Wm−2 K−1. The study of heat transfer to a horizontal tube immersed in the bed as well as placed in the freeboard region were also studied. The effective heat transfer coefficients were found to be 300–800 W m−2 K−1 for in-bed tube and 30–150 W m−2 K−1 for the freeboard region, depending on air velocity. Comparison of these data with those predicted by both modelling and correlation reported in the literature was also made. For the immersed tube, good agreement was observed for low air velocity, while at high air velocity the experiment produced results twice those estimated from modelling and correlation. For the freeboard region, the model gave a fair prediction.  相似文献   

16.
In this study, the forces affecting the motion of particle clusters near the wall of a CFB were theoretically analysed. The motion trajectory and the contact time of clusters were determined from the proposed model for two cases, steel ball having density of 6980 kg m?3 and sand having density of 2500 kg m?3. Computational results showed that the construction and operational parameters such as the bed equivalent diameter, the gas velocity and the bed temperature have great influence on the contact time of clusters. Based on analysis of the contact time of clusters, a theoretical model was developed for predicting the particle–gas convection heat transfer coefficient. The results were compared with experiments and were a quite agreement with the measured data in the open literature which suggests that the theoretical analysis conducted in this work can very well describe the convection heat transfer in a CFB. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

17.
Local instantaneous temperature signal and time‐averaged heat transfer coefficient were measured using a miniature heat transfer probe. The experiments were carried out in the bottom zone of a 5.8m high, 0.3m×0.5m rectangular cross‐section circulating fluidized bed. The results show that the heat transfer coefficient was higher near the walls, and became lower near the central region, and that the heat transfer coefficient decreases with increment of the air velocity due to the associated reduction of solids holdup in the bottom zone. In addition, the power spectrum density functions of the local instantaneous temperature signal can be characterized by the 1/f‐like distribution. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

18.
《能源学会志》2014,87(4):314-320
The purpose of this work is to investigate and develop a correlation for predicting the profile of heat flux on the crest of the membrane water wall tube along the height of circulating fluidized bed furnaces. The heat conduction equation for the tube was solved numerically under various operating conditions and furnace sizes. It was found that the temperature and heat flux profiles decreased rapidly in the region above the secondary air ports and then were found to be nearly constant. In addition, the heat flux increased as the Froude number increased or as the bed particle to the furnace diameter ratio decreased. The results were used to develop a correlation for predicting the heat flux profiles of the boilers having capacities from 12 MWth to 165 MWth in terms of dimensionless temperature, the Froude number, the diameter ratio and the height from the ports to the total height ratio.  相似文献   

19.
An imaginary plane method for calculation of radiative heat trensfer and its application in the freeboard of AFBC boiler is presented in this paper. The combustion reaction and particle concentration are taken into account in this method. With is method, one-dimensional freeboard model for radiative heat transfer has been made. Results from this model have been compared with the experimental results of a 130 t/h AFBC boiler. The distribution of flue gas temperature and heat flux at the waterwell are obtained. It is shown that this model has the advantage of good accuracy and requiring less computation time. The applicability of the predicted results in the AFBC boiler design and operation was also discussed.  相似文献   

20.
The characteristics of heat transfer from bubbling gas-fired fluidized bed to a horizontal staggered water-tube bundle located in the freeboard region is experimentally investigated. The purpose is to demonstrate the effect of bed temperature on the coefficients of heat transfer by the different modes to each of the four rows of the bundle, which experiences heat transfer by convection from flue gases, luminous radiation from bed material and non-luminous radiation from gases. The bed temperature itself is varied and controlled through the fuel–air mass ratio. Sixteen runs have been conducted with bed temperature ranging from 1114 to 1429 K, resulting in an overall heat transfer coefficient in the range 74·0–105·0 W m−2 K−1 for the first row and 58·0–65·0 W m−2 K−1 for the last. An overall convective heat transfer coefficient from gases, and possible carried over sand particles, to the bundle is formulated. © 1997 by John Wiley & Sons, Ltd.  相似文献   