首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
BACKGROUND: Intracoronary stenting reduces the rate of restenosis after angioplasty in patients with new coronary lesions. We conducted a prospective, randomized, multicenter study to determine whether intracoronary stenting, as compared with standard balloon angioplasty, reduces the recurrence of luminal narrowing in restenotic lesions. METHODS: A total of 383 patients who had undergone at least one balloon angioplasty and who had clinical and angiographic evidence of restenosis after the procedure were randomly assigned to undergo standard balloon angioplasty (192 patients) or intracoronary stenting with a Palmaz-Schatz stent (191 patients). The primary end point was angiographic evidence of restenosis (defined as stenosis of more than 50 percent of the luminal diameter) at six months. The secondary end points were death, Q-wave myocardial infarction, bypass surgery, and revascularization of the target vessel. RESULTS: The rate of restenosis was significantly higher in the angioplasty group than in the stent group (32 percent as compared with 18 percent, P= 0.03). Revascularization of the target vessel at six months was required in 27 percent of the angioplasty group but in only 10 percent of the stent group (P=0.001). This difference resulted from a smaller mean (+/-SD) minimal luminal diameter in the angioplasty group (1.85+/-0.56 mm) than in the stent group (2.04+/-0.66 mm), with a mean difference of 0.19 mm (P=0.01) at follow-up. Subacute thrombosis occurred in 0.6 percent of the angioplasty group and in 3.9 percent of the stent group. The rate of event-free survival at 250 days was 72 percent in the angioplasty group and 84 percent in the stent group (P=0.04). CONCLUSIONS: Elective coronary stenting was effective in the treatment of restenosis after balloon angioplasty. Stenting resulted in a lower rate of recurrent stenosis despite a higher incidence of subacute thrombosis.  相似文献   

2.
The authors studied retrospectively a series of 39 patients with a documented second restenosis after coronary angioplasty between January 1987 and November 1992, 33 of whom (31 men, 2 women) underwent a third procedure. The artery dilated was the left anterior descending (n = 17 including 9 proximal stenoses), the right coronary (n = 10), the left circumflex or its branches (n = 5) and the left main stem (n = 1). The lesions were confirmed to one vessel in 25 cases (75%) and affected two vessels in 8 cases (25%). The third angioplasty procedure was performed on a single artery in all cases. The average left ventricular ejection fraction was 60% (43%-75%). The diameter of the dilated artery was over 3.25 mm in 24% of cases (8/33). The primary success rate was 100% without any complications. The average period between the first and second angioplasties was 16 +/- 10 weeks, and between the second and third angioplasties 19 +/- 12 weeks. Angioplastic controls of the 3rd angioplasty were performed in 25 cases (75%). A third restenosis (n = 7) was treated by surgical bypass (n = 1), repeat angioplasty (n = 4), endocoronary stenting (n = 1) or medically (n = 1), with a global follow-up of 22 months (2-56 months), 2 patients underwent coronary bypass grafting, 2 have residual angina (contralateral lesion which could not be dilated), 1 had an infarct in the territory of an undilated artery, and 28 (85%) were asymptomatic. The restenosis rate after the third angioplasty procedure was 28% (7/25).(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

3.
BACKGROUND: Restenosis has been perceived as the tail end of a normal distribution of the response of the vessel to the intervention. However, recent studies have described a bimodal distribution for de novo lesions after percutaneous transluminal coronary angioplasty. This finding suggests that some lesions may be more susceptible for restenosis. Whether this holds true for a wider spectrum of lesions undergoing stent placement is not yet known. The present study analyzes the frequency distribution of angiographic indexes of restenosis 6 months after coronary stent implantation. METHODS AND RESULTS: Quantitative angiographic evaluation was performed in 1084 lesions of 1084 patients before, immediately after, and 6 months after successful Palmaz-Schatz stent placement; this represented 80.4% of patients eligible for follow-up angiography. Principal end points of the analysis were angiographic indexes of restenosis at 6 months. Twenty-two lesions that became totally occluded at follow-up were excluded from most parts of the analysis. Diameter stenosis, minimal luminal diameter (MLD), and lumen loss at 6 months did not follow a normal pattern; the bimodal pattern was demonstrated through deconvolution that yielded two separate normal components delineating two lesion populations, which developed distinctively different degrees of lumen renarrowing. The first and larger subgroup of lesions, which was less prone to restenosis, was centered around a mean value of 27% for diameter stenosis and 2.19 mm for MLD, whereas the second subgroup, with a greater tendency for restenosis, was situated around a mean value of 68% for diameter stenosis and 0.76 mm for MLD. The intersection point between the two theoretical normal distribution components was 53.5% for diameter stenosis and 1.09 mm for MLD at follow-up. CONCLUSIONS: Frequency-distribution curves of angiographic indexes of restenosis after coronary stent placement have a bimodal pattern, suggesting the existence of two distinct populations with different propensity to restenosis. These findings may encourage future efforts for the timely identification of the subset with a higher risk as the target of specific antirestenotic strategies.  相似文献   

4.
Management of in-stent restenosis has become a significant challenge in interventional cardiology. The results of balloon angioplasty have been disappointing due to the high recurrence of restenosis at follow-up. Debulking of the restenotic tissue within the stents using directional coronary atherectomy (DCA) may offer a therapeutic advantage. We report the immediate clinical and angiographic outcomes and long-term clinical follow-up results of 45 patients (46 lesions), mean age 63+/-12 years, 73% men, with a mean reference diameter of 2.9+/-0.6 mm, treated with DCA for symptomatic Palmaz-Schatz in-stent restenosis. DCA was performed successfully in all 46 lesions and resulted in a postprocedural minimal luminal diameter of 2.7+/-0.7 mm and a residual diameter stenosis of 17+/-10%. There were no in-hospital deaths, Q-wave myocardial infarctions, or emergency coronary artery bypass surgeries. Four patients (9%) suffered a non-Q-wave myocardial infarction. Target lesion revascularization was 28.3% at a mean follow-up of 10+/-4.6 months. Kaplan-Meier event-free survival (freedom from death, myocardial infarction, and repeat target lesion revascularization) was 71.2% and 64.7% at 6 and 12 months after DCA, respectively. Thus, DCA is safe and efficacious for the treatment of Palmaz-Schatz in-stent restenosis. It results in a large postprocedural minimal luminal diameter and a low rate of both target lesion revascularization and combined major clinical events at follow-up.  相似文献   

5.
OBJECTIVES: The purpose of this study was to evaluate the effects of thermal balloon percutaneous transluminal coronary angioplasty using radiofrequency energy in the treatment of patients with failed coronary angioplasty and complex lesions. In addition, we evaluated restenosis after radiofrequency thermal balloon applications. BACKGROUND: The efficacy of coronary angioplasty is limited by the relatively low success rate in complex lesions and the high frequency of restenosis. Few reports have studied the combined effects of pressure and laser thermal energy. This study describes a new device for coronary angioplasty using radiofrequency thermal energy. METHODS: Thirty-two patients with failed conventional coronary angioplasty or complex lesions were treated with radiofrequency thermal balloon coronary angioplasty. Radiofrequency energy was delivered up to 11 times in exposures ranging from 30 to 60 s in duration. This combined effect allowed the vascular wall to be heated to temperatures ranging from 60 to 70 degrees C. Follow-up coronary angiography was performed, on average, 6 months after the procedure. RESULTS: Successful radiofrequency coronary angioplasty was achieved in 28 (82%) of 34 lesions. There was one abrupt coronary artery occlusion (3%) and no death, perforation or dissection. Angiographic restenosis occurred in 14 (56%) of 25 lesions. CONCLUSIONS: In patients with failed coronary angioplasty and difficult complex lesions, radiofrequency coronary angioplasty could potentially improve angioplasty success rates and may have important implications for bailout cases with abrupt occlusion. However, restenosis remains a significant problem.  相似文献   

6.
With the increasing clinical application of new devices for percutaneous coronary revascularization, maximization of the acute angiographic result has become widely recognized as a key factor in maintained clinical and angiographic success. What is unclear, however, is whether the specific mode of action of different devices might exert an additional independent effect on late luminal renarrowing. The purpose of this study was to investigate such a difference in the degree of provocation of luminal renarrowing (or 'restenosis propensity') by different devices, among 3660 patients, who had 4342 lesions successfully treated by balloon angioplasty (n = 3797), directional coronary atherectomy (n = 200), Palmaz-Schatz stent implantation (n = 229) or excimer laser coronary angioplasty (n = 116) and who also underwent quantitative angiographic analysis pre- and post-intervention and at 6-month follow-up. To allow valid comparisons between the groups, because of significant differences in coronary vessel size (balloon angioplasty = 2.62 +/- 0.55 mm, directional coronary atherectomy = 3.28 +/- 0.62 mm, excimer laser coronary angioplasty = 2.51 +/- 0.47 mm, Palmaz-Schatz = 3.01 +/- 0.44 mm; P < 0.0001), the comparative measurements of interest selected were the 'relative loss' in luminal diameter (RLoss = loss/vessel size) to denote the restenosis process, and the 'relative lumen at follow-up' (RLfup = minimal luminal diameter at follow up/vessel size) to represent the angiographic outcome. For consistency, lesion severity pre-intervention was represented by the 'relative lumen pre' (RLpre = minimal luminal diameter pre/vessel size) and the luminal increase at intervention was measured as 'relative gain' (relative gain = gain/ vessel size). Differences in restenosis propensity between devices was evaluated by univariate and multivariate analysis. Multivariate models were constructed to determine relative loss and relative lumen at follow-up, taking account of relative lumen pre-intervention, lesion location, relative gain, vessel size and the device used. In addition, model-estimated relative loss and relative lumen at follow-up at given relative lumen pre-intervention relative gain and vessel size, were compared among the four groups. Significant differences were detected among the groups both with respect to these estimates, as well as in the degree of influence of progressively increasing relative gain, on the extent of renarrowing (relative loss) and angiographic outcome (relative lumen at follow-up), particularly at higher levels of luminal increase (relative gain). Specifically, lesions treated by balloon angioplasty or Palmaz-Schatz stent implantation (the predominantly 'dilating' interventions) were associated with more favourable angiographic profiles than directional atherectomy or excimer laser (the mainly 'debulking' interventions). Significant effects of lesion severity and location, as well as the well known influence of luminal increase on both luminal renarrowing and late angiographic outcome were also noted. These findings indicate that propensity to restenosis after apparently successful intervention is influenced not only by the degree of luminal enlargement achieved at intervention, but by the device used to achieve it. In view of the clinical implications of such findings, further evaluation in larger randomized patient populations is warranted.  相似文献   

7.
Conventional balloon angioplasty treatment of aorto-ostial stenoses in native coronary arteries and saphenous vein grafts is associated with a low primary success rate, a high complication rate and a high incidence of restenosis. The short-term outcome of Palmaz-Schatz stent implantation in aorto-ostial lesions was compared with that of balloon angioplasty. Thirteen patients underwent stent implantation for 13 de novo lesions (four in the left main coronary trunk, two in the right coronary artery, seven in the vein graft) between January 1994 and December 1995. Fourteen patients underwent balloon angioplasty for 14 de novo lesions (five in the left main coronary trunk, four in the right coronary artery, five in the vein graft between January 1986 and April 1992. Both groups had similar clinical characteristics. Initial success was obtained in all patients in the stent group, compared with 71% of the balloon angioplasty group. Insufficient dilation was the main cause for such failure in the balloon angioplasty group. Baseline reference diameters were similar (3.40 +/- 0.65 mm in the stent group vs 3.36 +/- 0.42 mm in the balloon angioplasty group) and there was no difference in baseline minimal luminal diameter (1.41 +/- 0.74 vs 1.08 +/- 0.56 mm). Minimal luminal diameter was significantly greater in the stent group than in the balloon angioplasty group at both post-procedure and follow-up examinations (post: 3.36 +/- 0.58 vs 2.69 +/- 0.45 mm, p < 0.01; follow-up: 2.33 +/- 0.96 vs 1.52 +/- 0.68 mm, p < 0.05). There was no subacute occlusion in either group. The overall angiographic restenosis rate (> 50% stenosis) was lower in the stent group (17%) than in the balloon angioplasty group: the restenosis rates of native lesions were 0% in the stent group and 40% in the balloon angioplasty group; those of saphenous vein graft lesions were 33% in the stent group and 50% in the balloon angioplasty group. Although the number of patients was limited, these results suggest that Palmaz-Schatz stent implantation may be a safe and effective strategy for treating aorto-ostial lesions in both native coronary arteries and saphenous vein grafts.  相似文献   

8.
OBJECTIVES: The purpose of this prospective study was to evaluate the immediate results and the 6-month angiographic recurrent restenosis rate after balloon angioplasty for in-stent restenosis. BACKGROUND: Despite excellent immediate and mid-term results, 20% to 30% of patients with coronary stent implantation will present an angiographic restenosis and may require additional treatment. The optimal treatment for in-stent restenosis is still unclear. METHODS: Quantitative coronary angiography (QCA) analyses were performed before and after stent implantation, before and after balloon angioplasty for in-stent restenosis and on a 6-month systematic coronary angiogram to assess the recurrent angiographic restenosis rate. RESULTS: Balloon angioplasty was performed in 52 patients presenting in-stent restenosis. In-stent restenosis was either diffuse (> or =10 mm) inside the stent (71%) or focal (29%). Mean stent length was 16+/-7 mm. Balloon diameter of 2.98+/-0.37 mm and maximal inflation pressure of 10+/-3 atm were used for balloon angioplasty. Angiographic success rate was 100% without any complication. Acute gain was lower after balloon angioplasty for in-stent restenosis than after stent implantation: 1.19+/-0.60 mm vs. 1.75+/-0.68 mm (p=0.0002). At 6-month follow-up, 60% of patients were asymptomatic and no patient died. Eighteen patients (35%) had repeat target vessel revascularization. Angiographic restenosis rate was 54%. Recurrent restenosis rate was higher when in-stent restenosis was diffuse: 63% vs. 31% when focal, p=0.046. CONCLUSIONS: Although balloon angioplasty for in-stent restenosis can be safely and successfully performed, it leads to less immediate stenosis improvement than at time of stent implantation and carries a high recurrent angiographic restenosis rate at 6 months, in particular in diffuse in-stent restenosis lesions.  相似文献   

9.
BACKGROUND: Experimental studies suggest that mural thrombus may be involved in postangioplasty restenosis. The aim of our study was to examine the role of angiographically identifiable thrombus in the clinical situation. METHODS AND RESULTS: The study population comprised 2950 patients (3583 lesions). The presence of angiographically identifiable thrombus either before or after the procedure was defined as the presence of a generalized haziness or filling defect within the arterial lumen. Restenosis was assessed by both a categorical (> 50% diameter stenosis at follow-up) and a continuous approach (absolute and relative losses). The study population included 160 lesions with and 3423 lesions without angiographically identifiable thrombus. The categorical restenosis rate was significantly higher in lesions containing angiographically identifiable thrombus: 43.1% versus 34.4%, P < .01; relative risk, 1,449; CI, 1.051 to 1.997. The absolute and relative losses were also higher in lesions containing angiographically identifiable thrombus (absolute loss, 0.43 +/- 0.66 versus 0.32 +/- 0.52; relative loss, 0.16 +/- 0.26 versus 0.13 +/- 0.21; both P < .05). The higher restenosis in these lesions was due primarily to an increased incidence of occlusion at follow-up angiography in this group: 13.8% versus 5.7%, P < .001. When lesions that went on to occlude by the time of follow-up angiography were excluded from the analysis, the restenosis rate between the two groups was similar by both the categorical (34.1% versus 30.4%, P=NS; relative risk, 1.183; CI, 0.824 to 1.696) and continuous (absolute loss, 0.23 +/- 0.46 versus 0.24 +/- 0.42, P=NS; relative loss, 0.09 +/- 0.17 versus 0.09 +/- 0.16, P=NS) approaches. CONCLUSIONS: Our results indicate that the presence of angiographically identifiable thrombus at the time of the angioplasty is associated with higher restenosis. The mechanism by which this occurs is through vessel occlusion at follow-up angiography. Measures aimed at improving outcome in this group of patients should be focused in this direction.  相似文献   

10.
It is unclear whether new devices such as directional coronary atherectomy (DCA) or Palmaz-Schatz stent implantation improve long-term outcomes compared with conventional balloon angioplasty in patients with stable angina and de novo coronary artery lesions of type A or type B except for complete occlusive lesions investigated by the American College of Cardiology/American Heart Association task force on percutaneous transluminal coronary angioplasty. A total of 146 patients with stable angina and simple lesions were assigned to either conventional balloon angioplasty (62 patients), DCA (50 patients), or Palmaz-Schatz implantation (34 patients). The acute results and late outcomes were assessed by coronary angiography. The results of the three procedures were similar with respect to procedural success and complications. Patients who underwent stenting or DCA had a larger immediate increase in the diameter of the lumen and a larger luminal diameter immediately after the procedure than those who underwent balloon angioplasty. At six months follow-up, the patients treated by stenting continued to have a larger luminal diameter and a lower rate of restenosis than those treated with balloon angioplasty (2.30 +/- 0.66 vs 1.85 +/- 0.83 mm, p < 0.005; 5.9% vs 29%, p < 0.05) and DCA (2.30 +/- 0.66 vs 1.90 +/- 0.96 mm, p < 0.05; 5.9% vs 24%, NS). The patients treated with balloon angioplasty had a smaller late loss than those treated with DCA or Palmaz-Schatz stent. The patients treated with DCA had a larger loss index than those treated with balloon angioplasty or Palmaz-Schatz stent. Stenting was a significant factor in decreasing the rate of restenosis by logistic regression analysis, compared with balloon angioplasty. The angiographic outcomes were better in patients who received a stent than in those who received other treatments. This study suggests that even lesions stable for treatment by balloon angioplasty and DCA can also be treated with Palmaz-Schatz stents.  相似文献   

11.
BACKGROUND: Experimental studies suggest that the antiproliferative effect of heparin after arterial injury is maximized by pretreatment. No previous studies of restenosis have used a pretreatment strategy. We designed this study to determine whether treatment with nadroparin, a low-molecular-weight heparin, started 3 days before the procedure and continued for 3 months, affected angiographic restenosis or clinical outcome after coronary angioplasty. METHODS AND RESULTS: In a prospective multicenter, double-blind, randomized trial, elective coronary angioplasty was performed on 354 patients who were treated with daily subcutaneous nadroparin (0.6 mL of 10,250 anti-Xa IU/mL) or placebo injections started 3 days before angioplasty and continued for 3 months. Angiography was performed just before and immediately after angioplasty and at follow-up. The primary study end point was angiographic restenosis, assessed by quantitative coronary angiography 3 months after balloon angioplasty. Clinical follow-up was continued up to 6 months. Clinical and procedural variables and the occurrence of periprocedural complications did not differ between groups. At angiographic follow-up, the mean minimal lumen diameter and the mean residual stenosis in the nadroparin group (1.37+/-0.66 mm, 51.9+/-21.0%) did not differ from the corresponding values in the control group (1.48+/-0.59 mm, 48.8+/-18.9%). Combined major cardiac-related clinical events (death, myocardial infarction, target lesion revascularization) did not differ between groups (30.3% versus 29.6%). CONCLUSIONS: Pretreatment with the low-molecular-weight heparin nadroparin continued for 3 months after balloon angioplasty had no beneficial effect on angiographic restenosis or on adverse clinical outcomes.  相似文献   

12.
Coronary angioplasty is used to treat coronary disease in many patients. Indications for angioplasty have expanded since it was first performed, mainly as a result of improvement in equipment and techniques. One problem with coronary angioplasty is the phenomenon of renarrowing of the treated coronary lesion, a process called restenosis. The events that constitute restenosis appear to be a universal response to the arterial wall injury of angioplasty. They are currently characterized as follows: platelet adhesion and aggregation on the damaged endothelium and within deep splits into the tunica media; release of platelet-derived growth factors; inflammation of the mechanically injured medial zone; transformation of smooth muscle cells of the tunica media after their activation by several of the growth-promoting substances; migration and proliferation of transformed smooth muscle cells, with secretion of copious amounts of extracellular matrix material; and, finally, termination of the growth process with regrowth of endothelium over the injured area. A decade of research work has helped identify clinical correlates of restenosis after coronary angioplasty procedures. This work is hindered by lack of a uniform angiographic definition of restenosis. In addition, much of the information has come from small studies, with incomplete follow-up and retrospective orientation. Nevertheless, some data are available. Patient-related correlates include male gender, unstable angina, diabetes, and continued smoking after angioplasty. Lesion-related correlates include multilesional and multivessel procedures, higher postangioplasty residual stenosis, proximal vessel location, location in the left anterior descending artery, location in a vein graft, long lesions, and total occlusions. The only consistent procedure-related correlate has been incorrect sizing of the angioplasty balloon to the treated artery. For the purposes of individual patient care, clinical correlates are not helpful. No group of variables has been found to be associated with complete freedom from restenosis, and no group is completely predictive of restenosis. All patients undergoing angioplasty procedures require some follow-up through subsequent months and years. Symptom status and the results of noninvasive studies have been investigated for purposes of follow-up. Symptoms are virtually useless by themselves for predicting restenosis or its absence. When symptom status is combined with exercise thallium 201 scintigraphy performed 4 to 6 months after an angioplasty procedure, the two factors are less than ideal but have a negative predictive value of more than 90%. This means that more than 90% of patients who have neither symptoms nor evidence of ischemia by thallium 201 scintigraphy will not have angiographic restenosis.(ABSTRACT TRUNCATED AT 400 WORDS)  相似文献   

13.
We examined the relation between diabetes mellitus and outcomes in patients undergoing percutaneous coronary revascularization in the Coronary Angioplasty Versus Excisional Atherectomy Trial (CAVEAT-I), a randomized trial comparing treatment with either percutaneous transluminal coronary angioplasty or directional atherectomy for de novo lesions in native coronary arteries. Acute success and complication rates, 6-month angiographic restenosis rates, and 1-year clinical outcomes were compared between diabetic and nondiabetic patients undergoing each procedure. Acute success rates between diabetic (n = 191) and nondiabetic (n = 821) patients were similar for both revascularization techniques. Except for the need for dialysis, complication rates were also similar. Six months after atherectomy, diabetic patients had significantly more angiographic restenosis than nondiabetics (59.7% vs 47.4%) and significantly smaller minimum luminal diameters (1.20 vs 1.40 mm). Diabetics undergoing atherectomy required more frequent bypass surgery (12.8% vs 8.5%) and more repeat percutaneous revascularizations (36.5% vs 28.1%) than nondiabetics undergoing atherectomy. Restenosis rates, minimum luminal diameters and repeat revascularizations between diabetics and nondiabetics undergoing angioplasty were similar. The higher restenosis and repeat revascularization rates and the smaller minimum luminal diameter at follow-up in diabetic patients suggest that atherectomy may provide only modest benefit for these patients. The increased restenosis rate in diabetics undergoing atherectomy (but not angioplasty) requires further evaluation.  相似文献   

14.
OBJECTIVES: This study sought to evaluate preintervention and postintervention intravascular ultrasound studies for potential predictors of angiographic restenosis and to use ultrasound predictors of restenosis to enhance our understanding of the pathophysiology of the restenosis disease process. BACKGROUND: Restenosis remains the major limitation of percutaneous transcatheter coronary revascularization. Although its mechanisms remain incompletely understood, numerous studies have identified some of the clinical, anatomic and procedural risk factors for restenosis. Intravascular ultrasound imaging of target lesions before and after catheter-based treatment consistently demonstrates more target lesion calcium, more extensive reference segment atherosclerosis, smaller final lumen dimensions, significant residual plaque burden and a greater degree of tissue trauma than is evident by angiography. METHODS: Intravascular ultrasound studies were performed in 360 nonstented native coronary artery lesions (final diameter stenosis 18 +/- 11%) in 351 patients for whom follow-up angiographic data were available 6.4 +/- 3.6 months later. Hospital charts were reviewed, and qualitative and quantitative coronary angiographic and intravascular ultrasound analyses were performed by independent core laboratories. Four dependent angiographic end points were tested: restenosis as a binary definition (> or = 50% diameter stenosis at follow-up) was the primary end point; follow-up diameter stenosis, late lumen loss and follow-up minimal lumen diameter were the secondary end points. RESULTS: Reference vessel size, the preintervention quantitative coronary angiographic assessment of lesion severity and the postintervention intravascular ultrasound cross-sectional measurements predicted the late angiographic results. In particular, the intravascular ultrasound postintervention cross-sectional narrowing (plaque plus media cross-sectional area divided by external elastic membrane cross-sectional area) predicted the primary end point (restenosis) and two of the three secondary end points (follow-up diameter stenosis and late lumen loss) and was therefore the most consistent predictor of restenosis. CONCLUSIONS: Intravascular ultrasound variables are more powerful and consistent predictors of angiographic restenosis than currently accepted clinical or angiographic risk factors.  相似文献   

15.
OBJECTIVES: We investigated the relation between insulin and coronary atherosclerosis and restenosis of the coronary arteries, by performing elective percutaneous transluminal coronary angioplasty (PTCA). BACKGROUND: Insulin is known to promote atherosclerosis of the arteries and has been implicated in the development of restenosis after PTCA. METHODS: Of 210 angina patients who underwent PTCA, newly detected lesions in 35 consecutive nondiabetic subjects without previous intervention on the same main coronary arteries were analyzed after a 75-g oral glucose tolerance test (OGTT) and follow-up coronary angiography. Atherosclerotic lesions were evaluated by pattern, severity and extent. Restenosis was defined as loss of gain, the percentage of loss of the initial gain in the coronary diameter achieved by PTCA > or = 50%. RESULTS: Patients with restenosis had a significantly higher extent index (a marker of atherosclerosis), insulin area, ratio of insulin area to glucose area, insulinogenic index and minimal lumen diameter after PTCA than those without restenosis (p=0.001, 0.011, 0.002, 0.016 and 0.041, respectively). Simple regression analysis revealed that only the ratio of insulin area to glucose area (a relative marker of enhanced insulin secretion) significantly correlated with the extent index (p=0.035). Extent index, insulin area, the ratio of insulin area to glucose area and insulinogenic index significantly correlated with loss of gain (p=0.001, 0.010, 0.002 and 0.032, respectively). Stepwise multiple regression analyses revealed that extent index and the ratio of insulin area to glucose area significantly correlated with loss of gain. CONCLUSIONS: Enhanced secretion of insulin during the OGTT might be useful as a predictor of coronary atherosclerosis and of restenosis after elective PTCA in nondiabetic patients with effort angina.  相似文献   

16.
Restenosis after successful coronary angioplasty (PTCA) occurs in 25-35% of all procedures. To date, most pharmacologic strategies have failed to reduce the restenosis rate significantly. However, recent studies have suggested a potential benefit of dietary supplementation with omega-3 fatty acids (fish oil) on restenosis following PTCA. The benefit of omega-3 polyunsaturated fatty acids on the incidence of coronary artery restenosis following elective PTCA was assessed in 212 consecutive patients (41 female, 171 male). Following a successful angioplasty, 204 patients received a dietary supplementation with either nine capsules containing fish oil (3.15 g omega-3 fatty acids) or nine placebo capsules containing olive oil. Treatment was started immediately after PTCA and maintained over 4 mon. Compliance was assessed by analysis of lipid fatty acids prior to angioplasty and at 4 mon follow-up. The angiographically determined incidence of restenosis (stenosis diameter > 50%) was 31.2% per lesion in patients receiving fish oil and 33.7% in patients receiving olive oil. Gross progression of coronary artery disease in vessels not subjected to angioplasty was 17% and 16%, respectively. In conclusion, low dose fish oil supplementation begun on the day of a successful coronary angioplasty failed to demonstrate any effect on coronary artery restenosis.  相似文献   

17.
Therapies that inhibit intimal hyperplasia do not prevent restenosis after coronary artery balloon angioplasty, suggesting that additional mechanisms may be responsible for restenosis in humans. Using an intravascular ultrasound (Hewlett-Packard Sonos Intravascular Imaging System). 3.5F, 30-MHz (Boston Scientific) monorail imaging catheter, we studied 17 patients with clinical and angiographic restenosis at an average (mean +/- SD) of 7 +/- 6 months after balloon angioplasty (13 men age, 71 +/- 10 years; 12 left anterior descending coronary arteries, 4 right coronary arteries, and 1 left circumflex coronary artery) The lumen area (L.A), vessel wall area (VWA), and total cross-sectional area (CSA) within the external elastic lamina were measured at the restenosis site and at proximal and distal reference sites, which were defined as adjacent segments with the least amount of plaque. Consistent with coronary angiography findings, decreased LA at the restenotic site was detected in all 17 patients. The unique finding was that total CSA at the restenotic site was significantly decreased compared with both proximal and distal reference sites (10.1 +/- 2.4 versus 14.8 +/- 3.2 mm2 and 10.1 +/- 2.4 versus 13.8 +/- 3.1 mm2, respectively, P < .001), whereas VWA (intima plus media) was slightly increased at the angioplasty site compared with both proximal and distal reference sites (8.0 +/- 2.3 versus 7.6 +/- 2.3 mm2 and 8.0 +/- 2.3 versus 6.7 +/- 2.3 mm2, respectively, P = NS). Eighty-three percent of the loss in LA at the restenotic site was due to constriction of the total CSA, while the increase in VWA at the restenotic site accounted for only a 17% loss in LA. We then compared these results with the morphology of coronary artery segments in 14 patients without restenosis. These coronary artery segments had been previously treated with balloon angioplasty (7 +/- 5 months). Unlike that in restenotic lesions, the total CSA within the external elastic lamina at the sites of previous angioplasty was similar to that in distal and proximal reference sites (P = NS). Significant and consistent reduction in arterial CSA, with a minor increase in VWA, characterizes human coronary lesions that cause angiographic restenosis. These data suggest that in humans, "recoil" and/or vascular contraction with healing in response to balloon injury is a major contributor to restenosis after balloon angioplasty.  相似文献   

18.
We evaluated the long-term angiographic outcome of balloon angioplasty by comparing original and follow-up target coronary narrowing. Rather than using restenosis to determine outcome, as in most angioplasty studies, we took an unusual approach and analyzed outcome in terms that are commonly used in progression and regression studies after medical interventions. Quantitative angiographic measurements were undertaken in 315 narrowings with an initial diameter stenosis <90% before and after angioplasty and at follow-up. Angiographic deterioration (>10% increase in follow-up diameter stenosis) was identified in 44 (14%) narrowings. Angiographic deterioration was not influenced by age, sex, risk factors, lipid profile, or the indication for angioplasty. Deterioration was also not predicted by the severity, length, or the location of the narrowing. The deteriorating narrowings had a higher recoil after dilatation compared with narrowings with angiographic improvement (21% +/- 31% vs 12% +/- 17%, p = 0.006); the residual stenosis after angioplasty was therefore higher. The late loss was also significantly increased compared with narrowings with angiographic improvement (65% +/- 26% vs 8% +/- 24%, p < 0.001). We conclude that the incidence of angiographic deterioration of coronary disease as a result of restenosis is uncommon but not negligible. Interventional cardiologists should resist the temptation to dilate mild, silent coronary narrowings because the procedure might have an unfavorable angiographic (and probably clinical) effect.  相似文献   

19.
BACKGROUND: At the initial stages of percutaneous transluminal coronary angioplasty (PTCA), several studies reported on the feasibility of coronary artery incision and dilatation leading to the extension of the PTCA technique. HYPOTHESIS: This study was designed to determine the immediate and chronic results of cutting balloon (CB) angioplasty. METHODS: This procedure was performed on 127 lesions in 110 patients (male 83%, age 61.8 +/- 9.3 years). RESULTS: The overall procedural success rates for the CB were 93.7% (119 lesions) and 92.7% (102 patients), while solitary CB without pre- and/or postdilatation was 76.4% (91 lesions). There was one major in-hospital complication (Q-wave myocardial infarction, 0.9%), but there were no deaths or emergency coronary artery bypass graftings. Significant angiographic dissections (> or = grade C) occurred in four patients, and coronary perforation occurred in one. The successfully treated CB group (95 lesions) was matched with the successful conventional angioplasty group (PTCA group) for chronic result assessment in regard to reference vessel size and lesion characteristics. In the CB group, postprocedural minimal luminal diameters were significantly larger and the percentage of stenosis at the stenotic site was significantly lower compared with the PTCA group. Restenosis occurred in 22 lesions (23.1%). This showed a significantly lower restenosis rate compared with the PTCA group (42.1%). In addition, the restenosis rate of the CB without inclusion of the pre- and/or postdilatation-treated lesions was 19.7%. CONCLUSIONS: (1) Cutting balloon angioplasty procedures can be performed with high success rates with few major inhospital events. (2) The restenosis rate in the CB group was significantly lower compared with the PTCA group.  相似文献   

20.
BACKGROUND: Several investigators report a sex bias in the treatment of coronary artery disease. This study attempts to define sex differences in the outcome of percutaneous transluminal coronary angioplasty (PTCA) and to determine risk factors contributing to these results. RESULTS: Data were collected from 1082 patients (887 men and 195 women). In women, the risk of abrupt vessel closure (8.1% versus 2.5%, odds ratio 3.46) and of myocardial infarction (6.2% versus 1.2%, odds ratio 5.58) following PTCA for stable angina pectoris was significantly increased. History of myocardial infarction and PTCA of a vessel of less than 3.0 mm diameter predicted abrupt vessel closure in women. Age and cardiovascular risk factors were not predictors. The incidence of restenosis did not differ significantly (angiographic restenosis in women 36.1% versus 40.8% in men, P=0.34). CONCLUSIONS: A significantly increased risk of acute complications could only be documented in women undergoing PTCA for stable angina pectoris and not in acute coronary syndrome. Long-term outcome was similar between the two sexes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号