首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this study, condensation heat transfer tests were conducted in flat aluminum multi-channel tubes using R-410A, and the results are compared with those of R-22. The flat tubes have two internal geometries; one with smooth inner surface and the other with micro-fins. Data are presented for the following range of variables; vapor quality (0.1–0.9), mass flux (200–600 kg/m2s) and heat flux (5–15 kW/m2). Results show that the effect of surface tension drainage on the fin surface is more pronounced for R-22 than R-410A. The smaller Weber number of R-22 may be responsible. For the smooth tube, the heat transfer coefficient of R-410A is slightly larger than that of R-22. For the micro-fin tube, however, the trend is reversed. Possible reasoning is provided considering physical properties of the refrigerants. For the smooth tube, Webb's correlation predicts the data reasonably well. For the micro-fin tube, the Yang and Webb model was modified to correlate the present data. The modified model adequately predicts the data.  相似文献   

2.
Hydrocarbons are considered as alternative fluids for refrigeration, air-conditioning and heat pump applications. Pure butane, propane or their mixtures can be adopted, but due to their flammable properties, the systems have to be designed in such a way that the refrigerant charge is minimized. Therefore, compact heat exchangers and enhanced geometries are adopted in such systems. In this paper, the current state of the art for two-phase heat transfer calculations for pure hydrocarbons and their mixtures is reviewed and analysed. Recommendations are proposed for estimating evaporation and condensation heat transfer in various geometries including enhanced tubes as well as compact heat exchangers.  相似文献   

3.
This paper reports on the experimental research conducted to study the condensation of ammonia on smooth and integral-fin (32 fpi) titanium tubes of 19.05 mm outer diameter. Experiments were carried out at saturation temperatures of 30, 35, 40 and 45 °C and wall subcoolings from 1 to 8 °C. The results show that the condensation coefficients on the smooth tubes are well predicted by the Nusselt theory with an average error of +0.66% and within a deviation between −6.6% and +8.3%. The enhancement factors provided by the integral-fin tubes range from 0.77 to 1.22. The low enhancement factors are due to the high condensate retention between fins, which brings about flooded fractions of the tube perimeter from 62.9% to 73.2%, and the low thermal conductivity of titanium. The Briggs and Rose [1994. Effect of fin efficiency on a model for condensation heat transfer on a horizontal, integral-fin tube. Int. J. Heat Mass Transfer 37, 457–463.] model, which accounts for the conduction in the fins, predicts the experimental data with a mean overestimation of 20%. The analysis of the partial thermal resistances in the overall heat transfer process points out the convenience of enhancing the outside ammonia condensation when high water velocities are considered inside the tubes.  相似文献   

4.
In this study, external condensation heat transfer coefficients (HTCs) are measured for nonazeotropic refrigerant mixtures (NARMs) of HFC32/HFC134a and HFC134a/HCFC123 on a low fin and Turbo-C tubes. All measurements are taken at the vapor temperature of 39 °C with the wall subcooling of 3–8 °C. Test results showed that condensation HTCs of NARMs on enhanced tubes were severely degraded from the ideal values showing up to 96% decrease. HTCs of the mixtures on Turbo-C tube were degraded more than those on low fin tube such that HTCs of the mixtures at the same composition were similar regardless of the tube. The mixture with larger gliding temperature differences (GTDs), HFC134a/HCFC123, showed a larger heat transfer reduction from the ideal values than the mixture with smaller GTDs, HFC32/HFC134a. Heat transfer enhancement ratios of the enhanced tubes with NARMs were almost 2 times lower than those with pure refrigerants and they decreased more as the GTDs of the mixtures increased.  相似文献   

5.
An experimental investigation of condensation heat transfer in 9.52 mm O.D. horizontal copper tubes was conducted using R22 and R410A. The test rig had a straight, horizontal test section with an active length of 0.92 m and was cooled by the heat transfer fluid (cold water) circulated in a surrounding annulus. Constant heat flux of 11.0 kW/m2 was maintained throughout the experiment and refrigerant quality varied from 0.9 to 0.1. The condensation test results at 45 °C were reported for 40–80 kg/h mass flow rate. The local and average condensation coefficients for seven microfin tubes were presented compared to those for a smooth tube. The average condensation coefficients of R22 and R410A for the microfin tubes were 1.7–3.19 and 1.7–2.94 times larger than those in smooth tube, respectively.  相似文献   

6.
Horizontal smooth and microfinned copper tubes with an approximate diameter of 9 mm were successively flattened in order to determine changes in flow field characteristics as a round tube is altered into a flattened tube profile. Refrigerants R134a and R410A were investigated over a mass flux range from 75 to 400 kg m−2 s−1 and a quality range from approximately 10–80%. For a given refrigerant mass flow rate, the results show that a significant reduction in refrigerant charge is possible. Pressure drop results show increases of pressure drop at a given mass flux and quality as a tube profile is flattened. Heat transfer results indicate enhancement of the condensation heat transfer coefficient as a tube is flattened. Flattened tubes with an 18° helix angle displayed the highest heat transfer coefficients. Smooth tubes and axial microfin tubes displayed similar levels of heat transfer enhancement. Heat transfer enhancement is dependent on the mass flux, quality and tube profile.  相似文献   

7.
This study presents a prediction model for the condensation heat transfer characteristics of binary zeotropic refrigerant mixtures inside horizontal smooth tubes. In this model, both the vapor-side and liquid-side mass transfers are considered, and the high flux mass transfer correction factor is used to evaluate mass transfer coefficients. The model was applied to the binary zeotropic refrigerant mixture R134a/R123, which has a large temperature glide. Calculation results showed that the heat transfer degradation of R134a/R123 due to gradients in the mass fraction and temperature is considerable, and depends on the mass fraction of the more volatile component and the vapor mass quality of the refrigerant mixture. By comparison with experimental data, incorporating the present finite mass transfer model for the liquid film side into the calculation algorithm was shown to reasonably well predict the condensation heat transfer coefficients of binary refrigerant mixtures with the mean deviation of about 10.3%. In the present calculations, however, it was also found that the high flux mass transfer correction factor had only a slight effect on the condensation heat transfer.  相似文献   

8.
This paper presents a critical review of correlations to compute heat transfer coefficients and pressure drop, for refrigerants condensing inside commercially available tubes with enhanced surfaces of various types, and a theoretical analysis of the condensation phenomenon. Predictions from some of the above equations are compared with experimental data. In addition, information is presented about the influence of small amounts of compressor oil on the condensation of refrigerants in enhanced tubes.  相似文献   

9.
The objectives of this paper are to develop experimental correlations of heat transfer for enhanced tubes used in a falling film condenser, and to provide a guideline for optimum design of the falling film condenser with a high condensing temperature of 59.8 °C. Tests are performed for four different enhanced tubes; a low-fin and three Turbo-C tubes. The working fluid is HFC134a, and the system pressure is 16.0 bar. The results show that the heat transfer enhancement of low-fin tube, Turbo-C (1), Turbo-C (2) and Turbo-C (3) ranges 2.8–3.4 times, 3.5–3.8 times, 3.8–4.0 times and 3.6–3.9 times, respectively, compared with the theoretical Nusselt correlation. It was found that the condensation heat transfer coefficient decreased with increasing the falling film Reynolds number and the wall subcooling temperature. It was also found that the enhanced tubes became more effective in the high wall subcooling temperature region than in the low wall subcooling temperature region. This study developed an experimental correlation of the falling film condensation with an error band of ±5%.  相似文献   

10.
Condensation heat transfer, both inside and outside horizontal tubes, plays a key role in refrigeration, air conditioning and heat pump applications. In the recent years the science of condensation heat transfer has been severely challenged by the adoption of substitute working fluids and new enhanced surfaces for heat exchangers. Well-known and widely established semiempirical correlations to predict heat transfer during condensation may show to be quite inaccurate in some new applications, and consequently a renewed effort is now being dedicated to the characterisation of flow conditions and associated predictive procedures for heat transfer and pressure drop of condensing vapours, even in the form of zeotropic mixtures. This paper critically reviews the most recent results appeared in the open literature and pertinent to thermal design of condensers for the air conditioning and refrigeration industry; both in-tube and bundle condensation are considered, related to the use of plain and enhanced surfaces.  相似文献   

11.
This paper presents a few salient features of an investigation carried out to study the heat transfer augmentation during condensation of water and R-134a vapor on horizontal integral-fin tubes. The experimental investigation was performed on two different experimental set-ups for water and R-134a. The test-sections were manufactured by machining fins over plain copper tubes of 24.4 ± 0.6 mm outside diameter. The performance of two types of finned tubes viz. circular integral-fin tubes (CIFTs) and spine integral-fin tubes (SIFTs) was studied for the condensation of water and R-134a. These tubes were positioned one by one inside the test-condenser to perform the experiments. All together the experiments were conducted for the condensation on 10 different test-section tubes. With the help of the experimental results, authors have developed an empirical equation. This equation predicts the condensing heat transfer coefficient from their own experimental data for the condensation over CIFTs and SIFTs within a range of ± 15% and experimental data of other thirteen investigators in a range of ± 35% for condensation of water and different refrigerants.  相似文献   

12.
Heat transfer coefficient and pressure drop were measured for condensation and evaporation of R410A and HCFC22 inside internally grooved tubes. The experiments were performed for a conventional spiral groove tube of 8.01 mm o.d. and 7.30 mm mean i.d., and a herring-born groove tube of 8.00 mm o.d. and 7.24 mm mean i.d. To measure the local heat transfer coefficients and pressure drop, the test section was subdivided into four small sections having 2 m working length. The ranges of refrigerant mass flow density was from 200 to 340 kg/(m2 s) for both condensation and evaporation of R410A and HCFC22, and the vapour pressure was 2.41 MPa for condensation and 1.09 MPa for the evaporation of R410A. The obtained heat transfer data for R410A and HCFC22 indicate that the values of the local heat transfer coefficients of the herring-bone grooved tube are about twice as large as those of spiral one for condensation and are slightly larger than those of spiral one for the evaporation. The measured local pressure drop in both condensation and evaporation is well correlated with the empirical equation proposed by the authors.  相似文献   

13.
This paper presents a study of flow regimes, pressure drops, and heat transfer coefficients during refrigerant condensation inside a smooth, an 18° helical micro-fin, and a herringbone tubes. Experimental work was conducted for condensing refrigerants R-22, R-407C, and R-134a at an average saturation temperature of 40 °C with mass fluxes ranging from 400 to 800 kg m−2 s−1, and with vapour qualities ranging from 0.85 to 0.95 at condenser inlet and from 0.05 to 0.15 at condenser outlet. These test conditions represent annular and intermittent (slug and plug) flow conditions. Results showed that transition from annular flow to intermittent flow, on average for the three refrigerants, occurred at a vapour quality of 0.49 for the smooth tube, 0.29 for the helical micro-fin tube, and 0.26 for the herringbone tube. These transition vapour qualities were also reflected in the pressure gradients, with the herringbone tube having the highest pressure gradient. The pressure gradients encountered in the herringbone tube were about 79% higher than that of the smooth tube and about 27% higher than that of the helical micro-fin tube. A widely used pressure drop correlation for condensation in helical micro-fin tubes was modified for the case of the herringbone tube. The modified correlation predicted the data within a 1% error with an absolute deviation of 7%. Heat transfer enhancement factors for the herringbone tube against the smooth tube were on average 70% higher while against the helical micro-fin tube it was 40% higher. A correlation for predicting heat transfer coefficients inside a helical micro-fin tube was modified for the herringbone tube. On average the correlation predicted the data to within 4% with an average standard deviation of 8%.  相似文献   

14.
Heat transfer coefficients were measured for the condensation of R410A and R22 inside internally grooved horizontal tubes. The experiment was performed for five different kinds of internally grooved tubes of about 8.00 mm o.d. the shapes of which were conventional helical grooved and herring-bone grooved ones. To measure the local heat transfer coefficients, the test section was subdivided into 10 small sections having 1 m working length. The ranges tested are as follows: the refrigerant mass velocity was from 130 to 400 kg/(m2/s) for R410A and R22, and the vapour pressure was 2.4l MPa for R410A and 1.53 MPa for R22. The obtained heat transfer data of R410A and R22 indicate that the values of the local heat transfer coefficients of the herring-bone grooved tube are about twice as large as those of helical one. All measured local heat transfer coefficients of condensation were compared with the predicted values from previous correlations proposed by other researchers, and were well correlated with the empirical equation using the frictional coefficients for each tube proposed by the author.  相似文献   

15.
This study discusses the effects of the heat exchanger type, refrigerant, inner tube configuration, and fin geometry on evaporator performance by adopting updated correlations of EVSIM, a numerical analysis model based on the tube-by-tube method developed by Domanski. The heat exchanger types considered are the cross-counter flow type and cross-parallel flow type. The refrigerants considered for the numerical test as a working fluid are R-134a, R-410A and R-22. For inner tube configuration, enhanced tube and smooth tube cases are considered. For the air side evaporation performance, heat exchangers using plate fins, wavy fins and slit fins are analyzed. Results show that the heat transfer rate of the cross-counter flow type heat exchanger is 3% higher than that of the cross-parallel flow type with R-22. The total heat transfer rate of the evaporator using R-410A is higher than those using R-22 and R-134a, while the total pressure drop of R-410A is lower than those of R-22 and R-134a. The heat transfer rate of the evaporator using enhanced tubes is two times higher than that using smooth tubes, but the pressure drop of the enhanced tube is 45–50% higher than that of the smooth tubes. The evaporation performance of slit fins is superior to that of plate fins by 54%.  相似文献   

16.
An experimental investigation was conducted to measure the local heat transfer coefficient for each row in a trapezoidal finned horizontal tube bundle during condensation of both pure fluid (HFC 134a) and several compositions of the non-azeotropic binary mixture HFC 23/HFC 134a. The test section is a 13×3 (rows × columns) tube bundle and the heat transfer coefficient is measured using the modified Wilson plot method. The inlet vapour temperature is fixed at 40 °C and the water flow rate in each active row ranges from 170 to 600 l/h. The test series cover five different finned tubes all commercially available, K11 (11 fins/inch), K19 (19 fins/inch), K26 (26 fins/inch), K32 (32 fins/inch), K40 (40 fins/inch) and their performances were compared. The experimental results were checked against available models predicting the heat transfer coefficient during condensation of pure fluids on banks of finned tubes. Modelling of heat exchange during condensation of binary mixtures on bundles of finned tubes based on the curve condensation model is presented.  相似文献   

17.
Effects of fin height and helix angle on condensation inside a herringbone microfin tube have been experimentally investigated with five types of herringbone microfin tubes. Heat transfer coefficients are about 2–4 times higher than that of the helical microfin tube under high mass velocity conditions. In the low mass velocity, they are equal to that of the helical microfin tube. The heat transfer enhancement increases with fin height up to 0.18 mm; higher fin heights show enhancement values similar to the 0.18 mm results. Pressure drop increases with the fin height. Larger helix angle yields higher heat transfer and higher pressure drop. For the lowest fin and/or smallest helix angle, the pressure drop is comparable with that of the helical microfin tube, while the heat transfer enhancement is higher. The enhancement mechanism is discussed from flow pattern observations. Effect of mass transfer resistance for R410A is estimated and negligible effects have been proved.  相似文献   

18.
Two-phase heat transfer coefficient characteristics of R404A condensing under forced flow conditions inside smooth, microfin and cross-hatched horizontal tubes are experimentally investigated. Experimental parameters include a lubricating polyol ester oil concentration varied from 0 to 4%. The test runs were done at average inlet saturated condensing temperatures of 40 °C. The inlet vapor was kept at saturation (quality=1.0). The mass fluxes were between 200 and 600 kg/m2 s, and the heat fluxes were selected to obtain a quality of 0.0 at the outlet of the test section, varying from 5 to 45 kW/m2. The heat transfer enhancement factor varied between 1.8 and 2.4 for both microfin and cross-hatched tubes. The larger values applied for larger mass fluxes for the cross-hatched tube and smaller mass fluxes for the microfin tube. Enhancement factors increased as oil concentration increased up to oil concentrations of 2%. For higher oil concentrations the enhancement decreased especially at high mass fluxes, the cross-hatched tube being less sensitive to oil contamination. Pressure drop in the test section increased by approximately 25% as the oil concentration increased from 0 to 4%. The results from the experiments are compared with those calculated from correlations reported in the literature. Moreover, modified correlations for the condensation heat transfer coefficient are proposed for practical applications.  相似文献   

19.
The condensation of pure HFC134a and different zeotropic mixtures with pure HFC134a and HFC23 on the outside of a bundle of smooth tubes was studied. The local heat transfer coefficient for each row was experimentally determined using a test section composed by a 13×3 staggered bundle of smooth copper tubes, measuring cooling water temperature in the inlet and the outlet of each tube, and measuring the vapour temperature along the bundle. All data were taken at the inlet vapour temperature of 40°C with a wall subcooling ranging from 4 to 26 K. The heat flux was varied from 5 to 30 kW/m2 and the cooling water flow rate from 120 to 300 l/h for each tube. The visualisation of the HFC134a condensate flow by means of transparent glass tubes reveals specific flow patterns and explains the difference between the measured values of the heat transfer coefficient and the calculated values from Nusselt's theory. On the other hand, the experimental heat transfer data with the binary mixtures HFC23-HFC134a show the important effects of temperature glide and the strong decrease of the heat transfer coefficient in comparison with the pure HFC134a data. The measured values with the different zeotropic mixtures were compared with the data calculated with the classical condensation model based on the equilibrium model. An improvement of this model is proposed.  相似文献   

20.
Because of the ozone layer depletion and global warming, new alternative refrigerants are being developed. In this study, evaporation heat transfer characteristic and pressure drop of carbon dioxide flowing upward in vertical smooth and micro-fin tubes were investigated by experiment with regard to evaporating temperature, mass flux and heat flux. The vertical smooth and micro-fin tubes with outer diameter (OD) of 5 mm and length of 1.44 m were selected as a test section to measure the evaporative heat transfer coefficient. The tests were conducted at mass fluxes from 212 to 530 kg/(m2 s), saturation temperatures from −5 to 20 °C and heat fluxes from 15 to 45 kW/m2, where the test section was heated by a direct heating method. The differences of heat transfer characteristics between the smooth and the micro-fin tubes were analyzed with respect to enhancement factor (EF) and penalty factor (PF). Average evaporation heat transfer coefficients for the micro-fin tube were approximately 111–207% higher than those for the smooth tube at the same test conditions, and PF was increased from 106 to 123%.  相似文献   